• Title/Summary/Keyword: mock test

Search Result 461, Processing Time 0.024 seconds

A Study of Mock Objects Generator for Applying XPwith Special Attention to C (C환경에서의 XP적용을 위한 모크객체생성기에 관한 연구)

  • Jung Young Mok;Park Jae Won;Lee Nam Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.1 s.33
    • /
    • pp.15-26
    • /
    • 2005
  • As one of the lightweight software development methodology, the XP (Extreme Programming) is the practical means to improve the productivity and qualify of software through the pursuit of 4 values - communication, simplicity, feedback, and courage. It appears, however, the TDD (Test Driven Development). one of the practices of in. has a problem. which is the unavailability of the test driven development in case of the prolonged period of testing or the failure of securing the independency of the test cases. This results in the emphasis on the importance of the Mock Objects recently. The Mock Objects, the one imitating the faulty real code, has the fundamentals of simplicity allowing even manual script but. due to the inefficiency of manual script of the Mock Objects in a real life, it is implemented the Mock Objects Generator such as Mockotjects, EasyMock in Java. It Is found difficult, however to apply the Mock Objects in C language due to its object -oriented Premise as well as the absence of mock objects generators for C language. Therefore, in this Paper it is presented the CMock, a Mock Objects generator fer C language which allows the easy creation of the Mock Objects, and the study is performed to verify the efficiency accordingly.

  • PDF

A Comparison Evaluation on the Indoor Temperature and Humidity Control Effect of Hwang-To Brick and Traditional Window as Exterior envelops in Mock-up Room (Mock-up 실험을 통한 황토벽과 전통창호의 실내 온습도 조절효과에 대한 비교평가)

  • Song, Min-Jeong;Shin, Hoon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.131-137
    • /
    • 2010
  • This study aims to know temperature and humidity handling ability of Hwang-To brick and traditional paper window's in mock-up room test. To achieve these goals, mock-up room test was carried out. The results are as follows. 1) There are no significant differences among specimen in temperature handling capacity. 2) Traditional paper windows are very sensitive when compared with glass window in humidity control. 3) Traditional paper windows have a big handling capacity in humidity control when vapors letting out in mock-up room. 4) Hwang-To brick case is more stable than other cases in relative humidity variances because it has more potential to contain humidity.

Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior (ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구)

  • Kim, Young-Ho;Lee, Yong-Soo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.

The Mock-Up Test for Applying Rebar Modularization to the Wall of Nuclear Power Plant (원전 벽체구조물의 철근모듈화 적용을 위한 Mock-Up 실험연구)

  • Lee, Byung-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.7-8
    • /
    • 2016
  • We are developing the technology for applying the Rebar Modularization Method to the Nuclear Power Plant Structures. To achieve this, we had developed the elementary technology for applying this method to Nuclear Power Plant Structures efficiently and performed the Mock-Up Test by using the developed elementary technology. By analysing this test result, we deduced the problems and found solutions to solve them.

  • PDF

Effect of Using Coal Gasification Slag as Fine Aggregate on Field Applicability of the Concrete through Mock-up Test (Mock up test를 통한 석탄가스화 발전슬래그를 잔골재로 사용한 콘크리트의 현장적용 가능성 분석)

  • Han, Jun Hui;Lee, Young Jun;Hyun, Seung Yong;Han, Min Cheol;Yoon, Ki Won;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.21-22
    • /
    • 2018
  • In this study, the characteristics of the Mock-up test were reviewed to analyze the applicability of the coal gasification slag (CGS) from the integrated gasification combination Cycle (IGCC) to the concrete fine aggregate. The analysis shows that CGS and crushed sand mix is the best combination of CGS combined with about 50 % of CGS based on the effects of promoting liquidity and strength. This is expected to be a positive factor in securing the strength and flexibility of concrete given the optimal mix of CGS, and may also contribute to the improvement of quality.

  • PDF

A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board (기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구)

  • Kim, Hea-Jeong;Song, Kyoo-Dong;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

Half-Mask Interface Prototype Design using Korean Face Anthropometric Data (한국인 안면부 인체 데이터를 이용한 마스크 계면 프로토타입 설계)

  • Song, Young-Woong;Yang, Won-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.87-92
    • /
    • 2010
  • The mask-face interface design should consider the face shape to improve the half mask respirator's fit ratio. This study tried to design the mask-face interface using recent Korean face data. By using the data of 1536 men's 3D face scanning (Size Korea data), head clay mock-up was made and mask-face interface line was extracted from this head mock-up. Using this interface line, the half-mask prototype was made. According to the quantitative fitting test, the proposed mask was found to be well fitted (average fit-ratio > 100). The proposed method had two advantages. 1) The method could use massive head-related anthropometric data like Size Korea data. 2) The qualitative fit test (observation) could be conducted very quickly by fitting the prototype to the head mock-up. However, this method also had several limitations. 1) The head clay mock-up could be different according to the mock-up maker. 2) The average values of the head-related anthropometric data were used to make the head mock-up. Small and large size head mock-ups should be made and tested.

Building Test Codes for Unit Test Automation of Java Programs (단위 테스트 자동화를 위한 자바 프로그램 테스트 코드 구축)

  • Yoon, Hoijin
    • Journal of Software Engineering Society
    • /
    • v.23 no.4
    • /
    • pp.141-149
    • /
    • 2010
  • Agile development is mentioned a lot by developers these days. XP or Scrum is one of the popular development processes, and it says that unit test automation would drive an agile development successful. The success of unit test automation depends on how well to compare an execution result to its own expected result. that is why this paper focuses on the comparison part. This paper introduces how to build test codes for unit testing, and then concludes with mentioning two considerations of unit testing automation. First, test codes for void-typed methods need Mock Framework to monitor their behavior. Second, the comparison of execution results and expected results is hard to implement in case of testing void-typed methods. We check every sentences of a test path to decide if the testing is fail or pass.

  • PDF

Study on Substitution Effect caused by Application of BIM Simulation System to Mock-up Site (시공단계 현장 Mock-up의 BIM 기반 시뮬레이션 기법 적용에 의한 기대효과 분석 연구)

  • Jang, Se-Jun;Yun, Seok-Heon;Paek, Joon-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.147-151
    • /
    • 2008
  • Construction project is completed through several stages and problems of each stage affect directly not only now but also next. Defect of 2D drawings influence in construction phase, and it make many loss on project. Nowadays we practically use real Mock-up test in construction sites to solve the problems. But it also has many problems which are waste much money and time. Therefore, this study tries to analyze effect that is occurred by appling BIM Mock-up simulation instead of real Mock-up execution. These analysis is conducted by comparing two construction building site. These have same shape but one is made for BIM Mock-up, and another is real Mock-up. Comparison points of view are cost, time and operator's satisfaction. It is expect that BIM Mock-up is more effective at low cost and on shorter time. But our analysis show that each are conducted different part of function. So new Mock-up type is required. Hybrid Mock-up is combine real mock-up with BIM simulation and it can minimize risk of project.

  • PDF