• Title/Summary/Keyword: mobile phase

Search Result 1,241, Processing Time 0.024 seconds

Cyclosophoraose as a Novel Chiral Stationary Phase for Enantioseparation

  • JUNG, YUN-JUNG;LEE, SANG-HOO;PAIK, SEUNG-R.;JUNG, SEUN-HO
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.6
    • /
    • pp.1338-1342
    • /
    • 2004
  • Cyclosophoraoses (Cys), cyclic ${\beta}-(1{\rightarrow}2)-D-glucans$ produced by Rhizobium meliloti 2011, were used as a novel chiral stationary phase for the enantiomeric separation. A novel Cys stationary phase, chemically immobilized onto porous silica via aminopropyltrimethoxysilane as a molecular linker, showed good separation for each racemate of bupivacain (separation factor, $\alpha$=1.3), propranolol ($\alpha$=1.3), and fenoprofen ($\alpha$=2.9), respectively, under the mobile phase of water: methanol (80:20, v/v) at a constant flow rate of 0.9 ml/min at pH7.

Error Rate Performance Variation by the Reception Phase Error in a Frequency-Selective Rayleigh Fading Channel Environment (주파수 선택성 레일리 페이딩 채널환경에서 수신 오차위상에 의한 오율 특성 변화)

  • 김용로;금홍식;류흥균
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.9
    • /
    • pp.6-13
    • /
    • 1993
  • In is well-known that system performance in the high speed digital radio communication system is usually deteriorted due to the frequency selective fading distortion. In this paper, bit error rate(BER) performance by the reception phase error in cellular mobile communication systems is derived and analyzed. The system is modeled as a frequency selective fast Rayleigh fading channel corrupted by additive white gaussian noise(AWGN) and co-channel interference(CCI). Our numerical results show that for the 24KBaud(48Kb/s) $\pi$/4-DQPSK operated at carrier frequency 800 MHz and C/I<20 dB, the BER will be dominated by CCI if the vehicular speed is below 100 Km/h. The results show that performance, when reception phase error is below $\pi$/12, is deterioreted less than 3 dB, and that performance, when reception phase error is above $\pi$/12, is degraded over 3 dB.

  • PDF

Determination of Fluorescent Whitening Agents in Paper Materials by Ion-Pair Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Jeong Soo;Kim, Do Hwan;Kim, Keon
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.3971-3976
    • /
    • 2012
  • A simple method was developed for the analysis of seven stilbene-type fluorescent whitening agents (FWAs) in paper materials by ion-pair reversed-phase high-performance liquid chromatography with fluorescence detection. These stilbene-type FWAs included two disulfonate, two tetrasulfonate, and three hexasulfonate compounds. After optimization of chromatographic conditions, the FWAs were satisfactorily separated using a reversed-phase column (RP-18) with the following isocratic mobile phase: methanol-water (60:40) containing 17.5 mM TBABr and 10 mM citrate buffer (pH = 7.0). The calibration plot was linear in the range from 5 to 500 ng/mL for two disulfo-FWAs and from 1 to 500 ng/mL for the other five FWAs. Precision levels of the calibration curve as indicated by RSD of response factors were 1.2 and 8.1%. Limits of quantitation (LOQ) ranged from 1.2 to 11 ng/mL.

A Study on the Surface Characteristics of Dual Phase Steel by Electron Backscatter Diffraction (EBSD) Technique

  • Jeong, Bong-Yong;Ryou, Min;Lee, Chongmu;Kim, Myung Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.20-23
    • /
    • 2014
  • Dual phase steels have a microstructure comprising of a polygonal ferrite matrix together with dispersed islands of martensite. There are clear differences between the image quality (IQ) map of the dual phase and the corresponding ferritic/pearlitic structures, both in the as-heat treated and cold rolled conditions. Electron backscatter diffraction (EBSD) techniques were used to study the evolution substructure of steel due to plastic deformation. The martensite-ferrite and ferrite-pearlite interfaces were observed. The interface can be a source of mobile dislocations which the bands seem to originate from the martensite islands. In particular, the use of image quality is highlighted.

A Design of Simple and Precision Direction Finder with a Combination of an Amplitude Measurement and Phase Measurement

  • Lim Joong-Soo
    • International Journal of Contents
    • /
    • v.1 no.2
    • /
    • pp.35-38
    • /
    • 2005
  • This paper describes a design of simple and precision direction finder that can be adapted to shipboard or mobile vehicles used for Electronic support measure, ELINT and radio signal monitoring systems. The direction finding technology has improved with monolithic integrated circuit, linear array antennas, and interferometer. Interferometer uses the phase-comparison principle and has a good direction finding accuracy but it has an ambiguity problem. We suggest a simple ambiguity solver using phase-comparison technology with amplitude-comparison principle. The direction finding device that has been designed by the suggested method has 0.7 degree RMS error in azimuth angle and 0.6 degree RMS error in elevation angle in 0.5 - 2.0 GHz.

  • PDF

A Study on Multi-level Attack Detection Technique based on Profile Table (프로파일 기반 다단계 공격 탐지 기법에 관한 연구)

  • Yang, Hwan Seok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.4
    • /
    • pp.89-96
    • /
    • 2014
  • MANET has been applied to a wide variety of areas because it has advantages which can build a network quickly in a difficult situation to build a network. However, it is become a victim of malicious nodes because of characteristics such as mobility of nodes consisting MANET, limited resources, and the wireless network. Therefore, it is required to lightweight attack detection technique which can accurately detect attack without causing a large burden to the mobile node. In this paper, we propose a multistage attack detection techniques that attack detection takes place in routing phase and data transfer phase in order to increase the accuracy of attack detection. The proposed attack detection technique is composed of four modules at each stage in order to perform accurate attack detection. Flooding attack and packet discard or modify attacks is detected in the routing phase, and whether the attack by modification of data is detected in the data transfer phase. We assume that nodes have a public key and a private key in pairs in this paper.

Solid-Phase Extraction of Caffeine and Catechin Compounds from Green Tea by Caffeine Molecular Imprinted Polymer

  • Jin, Yinzhe;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.276-280
    • /
    • 2007
  • In this work, caffeine and some catechin compounds + C, EC, EGC, and EGCG were extracted from green tea by using molecular imprinted polymers (MIP) as sorbent materials in a solid-phase extraction (SPE) process known as MISPE (molecular imprinted solid-phase extraction). For synthesis of MIP, caffeine was employed as the template, MAA as the monomer, EGDMA as the crosslinker, and AIBN as the initiator. A solution of caffeine (0.2 mg/mL in methanol) was utilized in the solid extraction cartridges following loading, washing, and elution procedures with acetonitrile, methanol, and methanol-acetic acid (90/10, %v/v) as the solvents, respectively. This solid-phase extraction protocol was applied for the extraction of caffeine and some catechin compounds from green tea. A comparison was made between the results obtained with the MIP cartridges and a traditional C18 reversed-phase cartridge. It was thereupon found that the recovery of caffeine by the MIPbased sorbent used in this work was almost two and four times greater than that by a commercially available C18 material. A quantitative analysis was conducted by high performance liquid chromatography (HPLC) using a C18 column (5 μm, 250 × 4.6 mm) with methanol/water (40/60, %v/v) as the mobile phase at a flow rate of 0.5 mL/min.

A Efficient Calculation for log and exponent with A Dual Phase Instruction Architecture (효율적인 로그와 지수 연산을 위한 듀얼 페이즈 명령어 구조)

  • Kim, Jun-Seo;Lee, Kwang-Yeob;Kwak, Jae-Chang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.320-323
    • /
    • 2010
  • This paper proposes efficient log and exponent calculation methods using a dual phase instruction set without additional ALU unit for a mobile enviroment. Using the Dual Phase Instruction set, it extracts exponent and mantissa from expression of floating point and calculates 24bit single precision floating point of log approximation using the Taylor series expansion algorithm. And with dual phase instruction set, it reduces instruction excution cycles. The proposed Dual Phase architecture reduces the performance degradation and maintain smaller size.

  • PDF

A Study on the Elution Mechanism of Ni(II)-Isonitrosoethylacetoacetate Imine Chelates by Reversed Phase High Performance Liquid Chromatography (역상 액체 크로마토그래피에 의한 Ni(II)-Isonitrosoethylacetoacetate Imine 유도체 킬레이트의 용리 메카니즘에 관한 연구)

  • Kim In-Whan;Choi Gang-Yeol;Lee Man-Ho;Kang Chang-Hee;Lee, Won
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.697-708
    • /
    • 1992
  • Liquid Chromatographic behavior of Ni(II) in Isonitrosoethylacetoacetate Imine(IEAA-NR), Ni(IEAA-NH)(IEAA-NR)(R = H, CH_3, C-2H_5, n-C_4H_9, C_6H_5-CH_2) chelates were investigated by reversed-phase HPLC on Micropak MCH-5 column using methanol/water as mobile phase. The optimum conditions for the separation of Ni(IEAA-NH)(IEAA-NR) chelates were examined with respect to the effect of the flow rate, sample solvent, mobile phase strength and column temperature. It was fo$und that metal chelates were properly eluted in an acceptable range of capacity factor value(0{\le}logk'{\le}1). The dependence of the logarithm of capacity factor (k') on the volume fraction of water in the binary mobile phase as well as on the liquid-liquid extraction distribution ratio (Dc) in methanol-water/n-alkane extraction system showed the good linearties, and the dependence of the logarithm of capacity factor (k') on the column temperature and on the enthalpy exhibited the good linearties, and the compensation temperature ({\beta}) from the slope was 773.47{\circ}K. It was suggested that the retention of metal chelates was largely affected by the hydrophobic effect.

  • PDF

Separation of Egg White Using HPLC with Change of Mobile Phase and Temperature (HPLC에서 이동상 변화와 온도에 따른 난백의 분리)

  • Do, Jin-Sun;Song, Shin-Young;Cho, Ki-Jung;Kim, In-Ho
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.829-834
    • /
    • 2011
  • Lysozyme in egg white functions as bacteriolysis agent and ovalbumin plays a role as antigen in immune system. Egg white analysis methods usually include electrophoresis, gel permeation chromatography and reversed-phase HPLC(RP-HPLC). Among them, RP-HPLC was selected for rapid analysis and C18 column(Agilent, USA) was used as HPLC column. Optimum conditions were searched by changing mobile phase and temperature. Capacity factor and resolution were calculated and compared for various elution conditions. In the isocratic elution, mobile phase volume ratio was changed from 30/70/0.1 to 60/40/0.1(Acetonitrile(ACN)/Distilled water(DW)/Trifluoroacetic acid(TFA)). ACN composition was increased by 10% and temperature was set as $20^{\circ}C$. In the gradient elution, ACN/DW ratio was changed from 10/90 to 60/40 during 20 minute and temperature was varied as 20, 30 and $40^{\circ}C$. In the isocratic elution, three peaks were separated at 50/50/0.1. Lysozyme and ovalbumin were confirmed as first and third peak in three peaks respectively. In the gradient elution, four peaks were separated at $30^{\circ}C$. Lysozyme and ovalbumin were confirmed as first peak and third peak in four peaks respectively.