• Title/Summary/Keyword: mm long

Search Result 2,158, Processing Time 0.027 seconds

Detection of Gnathostoma spinigerum Advanced 3rd-Stage Larvae in the Chinese Edible Frog, Hoplobatrachus rugulosus, from Local Markets in Phnom Penh, Cambodia

  • Sohn, Woon-Mok;Jung, Bong-Kwang;Hong, Sooji;Ryoo, Seungwan;Lee, Keon Hoon;Khieu, Virak;Chai, Jong-Yil
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.5
    • /
    • pp.519-522
    • /
    • 2021
  • The Chinese edible frogs, Hoplobatrachus rugulosus (n=20), and the striped snakehead fish, Channa striata (n=34), were purchased from local markets in 3 administrative regions of Cambodia (Phnom Penh, Pursat, and Takeo Provinces) from May 2017 to April 2019, and their infection status with Gnathostoma sp. larvae was investigated. The frogs and fish were transported to the laboratory with ice and examined using the artificial digestion method. Advanced 3rd-stage larvae (AdL3) of Gnathostoma spinigerum, 24 in total number (1-6 larvae/frog), were detected from 6 (60.0%) out of 10 frogs purchased from Phnom Penh. No gnathostome larvae were detected in 10 frogs purchased from Takeo Province and 34 snakeheads from Phnom Penh, Pursat, and Takeo Provinces. AdL3 isolated from the frogs were 2.55-3.90 mm long and 0.31-0.36 mm wide. They had a characteristic head bulb (0.081×0.191 mm in average size) with 4 rows of hooklets, a muscular long esophagus (0.950-1.230 mm long), and 2 pairs of cervical sacs (0.530-0.890 mm long). The average number of hooklets in the 1st, 2nd, 3rd, and 4th rows was 41, 45, 48, and 51, respectively. These features were consistent with G. spinigerum AdL3. By the present study, it has been first confirmed that the Chinese edible frog, H. rugulosus, from Phnom Penh serves as a second intermediate host for G. spinigerum, although their intensity of infection was not so high compared to other previously reported localities.

Research on the Decrease of Dud Ammunition Rate of 40mm Grenade(K200) Fuze through Quality Improvement (40mm 저속유탄(K200) 신관 품질개선을 통한 불발율 감소에 관한 연구)

  • Ju, Jin-Chun;Kim, Yong-Hwa;Ahn, Nam-Su;Kim, Sang-Min;Ha, Su-Ra
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.700-707
    • /
    • 2016
  • Recently, ammunition malfunctions of the 40mm grenade were reported during live fire training. When 72 40mm grenades were fired by the army, 11 duds were encountered. The dud ammunition rate was approximately 15%. Because ammunition is used a long time after its manufacture, it is necessary to ensure its performance after long-term storage. In this study, we attempted to decrease the dud ammunition rate of 40mm grenade (K200) fuzes through quality improvement. First, it was determined by the detonator performance test that abnormal explosions occurred due to the degradation of the detonator as a result of its aging characteristics. Second, we improved the fuze quality of the 40mm grenade. Third, we tested its shelf life to estimate its life expectancy. The shelf life of the 40mm grenade fuze obtained using the Arrhenius equation was 6.5 years for the existing grenade fuze and 45.5 years for the improved grenade fuze. This showed that the shelf life of the improved grenade was increased approximately 7 times. Therefore, the improved 40mm grenade fuze contributes to the quality improvement of the 40mm grenade by decreasing the dud ammunition rate during long term storage.

A within-subject comparison of short implants in the posterior region: retrospective study of up to 10 years

  • Segalla, Douglas Blum;Villarinho, Eduardo Aydos;Correia, Andre Ricardo Maia;Vigo, Alvaro;Shinkai, Rosemary Sadami Arai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.172-179
    • /
    • 2021
  • Purpose. This intra-patient retrospective study of up to 10 years evaluated the clinical success and risk factors of 6- and 8-mm long implants and their respective prostheses. Materials and Methods. The sample consisted of patients treated at a Military Polyclinic dental service, who received both 6- and 8-mm long tissue level implants in the posterior region of the same arch. Data were collected from the dental charts, clinical and radiographic exams, self-report of sleep bruxism, measurement of maximum occlusal force, and clinical crown-to-implant (C/I) ratio. Data were analyzed by descriptive and inferential statistics with univariate and hierarchical multivariate models, at the 0.05 significance level. Results. The 30 patients (27 women) had 85 implants and 83 prostheses. Two implants were lost before prosthesis installation (implant survival: 97.6%). Ten events of prosthetic complication (screw tightening loss) occurred in five patients (success rate: 87.9%) in a single moment. Only the variable C/I ratio had a significant effect for repairable prosthesis complication (P<.05). Conclusion. The results suggest that 6- and 8-mm long implants have similar long-term clinical success for implants and prostheses.

Comparison of Size Criteria in Mediastinal Lymph Node Involvement of Adenocarcinoma of Lungs (폐 선암의 종격동 림프절 전이에 있어서 림프절 크기 기준의 비교)

  • Gu, Ki-Seon;Kuk, Hiang;Koh, Hyeck-Jae;Yang, Sei-Hun;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.542-547
    • /
    • 1999
  • Background: Decision in mediastinal lymph node involvement of lung cancer by CT scan is very important and valuable for the treatment planning and prognosis prediction. In general, long diameter of mediastinal lymph node more than 15mm is used as criterion of lung cancer involvement. Adenocarci-noma has a tendency of early distant metastasis and micrometastasis, so adenocarcinoma may involve lymph node earlier and cannot be detected before lymph nodes are enlarged enough. The authors tried to determine the difference between two size criteria(15mm, 10mm) in adenocarcinoma for the detection of cancer involvement. Methods: Numbers of sample are 60 cases(male 46, female 14, median age: 61.5 years). According to pathology, squamous cancer 41, large cell cancer 2, adenocarcinoma 17. According to TNM stage, I 23, III 24, IIIA 13. Results : Mean long diameter of lymph node involvement is 16.0($\pm8.0$) mm in non-adenocarcinoma group, and that of adenocarcinoma group is 12.0($\pm3.2$) mm(p<0.05). If long diameter of lymph node larger than 15mm as involvement criterion is applied, sensitivity, specificity, positive predictive index, negative predictive index, accuracy of nonadenocarcinoma group are 54%, 100%, 100%, 83%, 86%, and those of adenocarcinoma group are 43%, 90%, 75%, 69%, 71%. If long diameter of lymph node larger than 10mm as involvement criterion is applied, sensitivity, specificity, positive predictive index. negative predictive index. accuracy of nonadenocarcinoma group are 65%, 77%, 61%, 92%, 79%, and those of adenocarcinoma group are 100%, 80%, 78%, 100%, 88%. Conclusion: Long diameter of lymph node larger than 10mm is more valuable criterion as lymph node involvement in adenocarcinoma of lungs.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL ($Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구)

  • Kim Woo-Young;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

The Echocardiographic Assessment and Clinical Application of Cardiac Disease in Korea Jin-do Dog II. Comparison of Aortic Root Internal Dimension with Right Pulmonary Artery Internal Dimension (진돗개에서 심장초음파 측정치의 평가와 임상적 응용 II. 대동맥기부내경과 우페동맥내경의 비교)

  • 박인철;강병규;손창호
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.187-193
    • /
    • 2000
  • Fifteen adult Korea Jin-do dogs were studied by echocardiography to obtain the basic data of the imaging planes and normal references ranges to the aorta and pulmonary artery internal dimension. Measurements of aortic root internal dimension(AOID) and right pulmonary artery internal dimension (RPAID) were made at modified pulmonary arteries level short-axis view and left ventricular outflow tract long-axis view. The aortic root internal dimension and right pulmonary artery internal dimension at modified pulmonary arteries level short-axis view were 18.7$\pm$1.3mm (mean$\pm$SD) and 10.1$\pm$0.8mm, respectively. And RPAID/AOID was 0.5$\pm$0.1mm. The aortic root internal dimension and right pulmonary artery internal dimension at left ventricular outflow tract long-axis view were 19.3$\pm$1.6 mm and 10.7$\pm$1.3mm, respectively. And RPAID/AOID was 0.5$\pm$0.1mm. These results indicate that modified pulmonary arteries level short-axis view is useful planes to examine the aortic root and pulmonary arteries, and aortic root internal dimension is significantly higher(40~50%)than the right pulmonary artery internal dimension. Therefore measurements of aortic root internal and right pulmonary artery internal dimension can be used for monitoring dilation of pulmonary artery.

  • PDF

Microspore Development According to the Floral Budsize in Astragalus membranaceus Bunge

  • Kim, Young-Guk;Son, Seok-Yong;Park, Chung-Heon;Seong, Nak-Sul;Lee, Bong-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.45 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Astragalus membranaceus has flowers that are similar to that of the legume family, but shows poor bearing when self-pollination is induced. Thus, this study was carried out observing the ripening procedure of pistils and stamens and development stages of pollen in the context of the birth and growth of the flower. As to the bearing of the flower of A. membranaceus, few pod setting and 13% pod setting were observed when self-pollination is induced by paper-bag covering or artificial pollination treated respectively. The result indicates that A. membranaceus is a cross-pollination plant. A pistil grew faster than a stamen until just before blooming. The flower size was about 17.0mm$\times$4.0mm. Pistils and stamens had the same length after flowering. Pollen mother cells passed through meiosis and mitosis when its length reached around 3.5mm, thus creating the tetrade when 4 mm long. Pollen attained full growth when the bud was about 10mm long. An anther was found to tend to dehisce when the length of a bud reached around 12.0mm. As to the shape of pollen, about 70 % were normal. 1% and 30 % were small or empty pollen respectively. The result indicates that pollen of A. membranaceus attains full growth just before anther dehiscence which occurs before blooming while pistils grow faster than stamens until before flowering.

  • PDF

Preparation of Microcolumns Made of Glass-Lined Stainless Steel Tubing or Other Materials and Their Chromatographic Application (내벽이 유리로 코팅된 스테인레스 스틸 관 및 기타 재질을 이용한 마이크로 컬럼의 제작과 그의 크로마토그래피 응용에 관한 연구 (Ⅱ))

  • An, Hyun Joo;Cheong, Won Jo
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.11
    • /
    • pp.863-868
    • /
    • 1995
  • We have prepared microcolumns made of stainless steel tubing, glass-lined stainless steel tubing, and silica-lined stainless steel tubing and examined their performances comparatively. The length of columns was fixed as 30 cm, and the I.D.'s, either 1 mm or 0.5 mm. Octadecyl bonded silica paticles $(5\mu)$ were used as the stationary phases. p-Nitroaniline, N,N-dimethyl-o-nitro-p-toluidine,and ethylbenzene were used as the test solutes. The glass-lined or silica-lined stainless steel columns showed better performances than the plain stainless steel column did. The number of theoretical plates over 10,000 were obtained even for the 0.5 mm I.D. (30 cm long) column as long as the glass-lined stainless steel tubing was used.

  • PDF

Study on the Performance Evaluation of CS-H Wall composed of Steel Fiber (강섬유를 이용한 CS-H 벽체의 성능 평가에 관한 연구)

  • YU, Nam-Jae;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.89-96
    • /
    • 2017
  • In this study, CS-H walls with large stiffness were constructed using geosythetics for use in excavation at a depth of 30 m or more in Korea, and in order to construct the CS-H wall suitable for the site conditions, the formulation was examined according to the change in the mixing ratio of the geosythetics and the slump value (slump flow) and as a result, in the target slump 180 mm and the slump flow 500 mm, the formulation was confirmed to meet the mechanical properties such as the initial bending strength, the long-term behavior, and the elastic modulus as well as the economic efficiency. However, in the slump flow 600 mm, the result indicated that the formulation was inappropriate in the mechanical properties such as the initial bending strength, the long-term behavior, and the elastic modulus.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MINIMUM CONTACT FRACTION OF BONE-IMPLANT INTERFACE (골조직과 임플랜트 계면의 최소접촉분율에 관한 삼차원 유한요소분석적 연구)

  • Jang, Kyoung-Soo;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.627-646
    • /
    • 1997
  • In order to find the degree of osseointegration at bone-implant interface of clinically successful implants, models including the 3.75mm wide, 10mm long screw type $Br{\aa}nemark$ implant as a standard and cylinder, 15mm long, 5.0mm wide, two splinted implants, and implants installed in various cancellous bone density were designed. Also, the amount of load and material of prostheses were changed. The stress and minimum contact fraction were analyzed on each model using three-dimensional finite element method(I-DEAS and ABAQUS version 5.5). The results of this study were as follows. 1. 10mm long, 3.75mm diameter-screw type implant had $36.5{\sim}43.7%$ of minimum contact fraction. 2. Cylinder type implant showed inferior stress distribution and higher minimum contact fraction than screw type. 3. As implant length was increased, minimum contact fraction was increased a little, however, maximum principal stress was decreased. 4. Implants with a large diameter had lower stress value with slightly higher minimum contact fraction than standard screw type. 5. Two splinted implants showed no change of minimum contact fraction. 6. The higher bone density, the lower stress value. 7. The material of occlusal surface had no effect on the stress of the bone-implant interface.

  • PDF