• 제목/요약/키워드: mm long

검색결과 2,158건 처리시간 0.036초

Installation and operation of automatic nonpoint pollutant source measurement system for cost-effective monitoring

  • Jeon, Jechan;Choi, Hyeseon;Shin, Dongseok;Kim, Lee-hyung
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.99-104
    • /
    • 2019
  • In Korea, nonpoint pollutants have a significant effect on rivers' water quality, and they are discharged in very different ways depending on rainfall events. Therefore, preparing an optimal countermeasure against nonpoint pollutants requires much monitoring. The present study was conducted to help prepare a method for installing an automatic nonpoint pollutant measurement system for the cost-effective monitoring of the effect of nonpoint pollutants on rivers. In the present study, monitoring was performed at six sites of a river passing through an urban area with a basin area of $454.3km^2$. The results showed that monitoring could be performed for a relatively long time interval in the upstream and downstream regions, which are mainly comprised of forests, regardless of the rainfall amount. On the contrary, in the urban region, the monitoring had to be performed at a relatively short time interval each time when the rainfall intensity changed. This was because the flow rate was significantly dependent on the rainfall's intensity. The appropriate sites for installing an automatic measurement system were found to be a site before entering the urban region, a site after passing through the urban region, and the end of a river where the effects of nonpoint pollutant sources can be well-decided. The analysis also showed that the monitoring time should be longer for the rainfall events of a higher rainfall class and for the sites closer to the river end. This is because the rainfall runoff has a longer effect on the river. However, the effect of nonpoint pollutant sources was not significantly different between the upstream and the downstream in the cases of rainfall events over 100 mm.

Description of Diplotriaena manipoli (Nematoda: Diplotriaenoidea) Detected in the Body Cavity of Garrulus glandarius brandtii from Republic of Korea

  • Hong, Eui-Ju;Ryu, Si-Yun;Chae, Joon-Seok;Kim, Hyeon-Cheol;Park, Jinho;Cho, Jeong-Gon;Choi, Kyoung-Seong;Yu, Do-Hyeon;Park, Bae-Keun
    • 한국임상수의학회지
    • /
    • 제36권3호
    • /
    • pp.133-138
    • /
    • 2019
  • The present study was performed to identify the nematodes recovered from the Eurasian jay, Garrulus glandarius brandtii, from Daejeon Metropolitan City, the Republic of Korea. Total five nematode worms were detected in the body cavities of two out of the twenty birds necropsied, and they were identified using morphological features, light and scanning electron microscope (SEM), and molecular (18S rRNA analysis) methods. The nematodes were all female Diplotriaena manipoli and had numerous eggs at different developmental stages in the uterus. The nematodes were long and slender measuring about 123-145 mm. The eight submedian cephalic papillae were arranged into four large, outer papillae and four small, inner-circle papillae. A pair of amphidal pores were located at the lateral portion of the mouth. The manubrium apex of trident was rounded and three branches of trident were bluntly rounded at the posterior ends. Using 18S rRNA partial sequence arrangements, DNA analysis of nematode worms was also carried out, and they were identified to be close to the Serratospiculum tendo based on a phylogenic tree analysis. To our knowledge, this is the first report on the molecular characterization and SEM study of D. manipoli.

Structural monitoring and analyses on the stability and health of a damaged railway tunnel

  • Zhao, Yiding;Yang, Junsheng;Zhang, Yongxing;Yi, Zhou
    • Advances in concrete construction
    • /
    • 제11권5호
    • /
    • pp.375-386
    • /
    • 2021
  • In this paper, a study of stability and health of a newly-built railway tunnel is presented. The field test was implemented to monitor the secondary lining due to the significant cracking behaviors influenced the stability and health of the tunnel structure. Surface strain gauges were installed for monitoring the status of crack openings, and the monitoring outputs demonstrated that the cracks were still in the developing stage. Additionally, adjacent tunnel and poor condition of surrounding rock were identified as the causes of the lining cracking by systematically characterizing the crack spatial distribution, tunnel site and surrounding rock conditions. Reconstruction of partial lining and reconstruction of the whole secondary lining were designed as the maintenance projects for different cracking regions based on the construction feasibility. For assessing the health conditions of the reinforced lining, embedded strain gauges were set up to continuously measure the strain and the internal force of the reconstructed structures. For the partially reconstructed lining, the outputs show the maximum tensile elongation is 0.018 mm during 227 days, which means the structure has no obvious deformation after maintenance. The one-year monitoring of full-section was implemented in the other two completely reconstructed cross-sections by embedded strain gauge. The outputs show the reconstructed secondary lining has undertaken the pressure of surrounding rock with the time passing. According to the calculated compressive and tensile safety factors, the completely reconstructed lining has been in reliable and safe condition during the past year after reinforcement. It can conclude that the aforementioned maintenance projects can effectively ensure the stability and health of this tunnel.

A Wide Dynamic Range NUC Algorithm for IRCS Systems

  • Cai, Li-Hua;He, Feng-Yun;Chang, Song-Tao;Li, Zhou
    • Journal of the Korean Physical Society
    • /
    • 제73권12호
    • /
    • pp.1821-1826
    • /
    • 2018
  • Uniformity is a key feature of state-of-the-art infrared focal planed array (IRFPA) and infrared imaging system. Unlike traditional infrared telescope facility, a ground-based infrared radiant characteristics measurement system with an IRFPA not only provides a series of high signal-to-noise ratio (SNR) infrared image but also ensures the validity of radiant measurement data. Normally, a long integration time tends to produce a high SNR infrared image for infrared radiant characteristics radiometry system. In view of the variability of and uncertainty in the measured target's energy, the operation of switching the integration time and attenuators usually guarantees the guality of the infrared radiation measurement data obtainted during the infrared radiant characteristics radiometry process. Non-uniformity correction (NUC) coefficients in a given integration time are often applied to a specified integration time. If the integration time is switched, the SNR for the infrared imaging will degenerate rapidly. Considering the effect of the SNR for the infrared image and the infrared radiant characteristics radiometry above, we propose a-wide-dynamic-range NUC algorithm. In addition, this essasy derives and establishes the mathematical modal of the algorithm in detail. Then, we conduct verification experiments by using a ground-based MWIR(Mid-wave Infared) radiant characteristics radiometry system with an Ø400 mm aperture. The experimental results obtained using the proposed algorithm and the traditional algorithm for different integration time are compared. The statistical data shows that the average non-uniformity for the proposed algorithm decreased from 0.77% to 0.21% at 2.5 ms and from 1.33% to 0.26% at 5.5 ms. The testing results demonstrate that the usage of suggested algorithm can improve infrared imaging quality and radiation measurement accuracy.

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권2호
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.

폴리우레탄 코팅장갑내의 DMF 함량 및 피부노출에 대한 평가 (Concentrations of N,N-dimethylformamide in Polyurethane Gloves and Risk Assessment for Dermal Exposures)

  • 박해동;노지원
    • 한국산업보건학회지
    • /
    • 제32권2호
    • /
    • pp.102-110
    • /
    • 2022
  • Objectives: The purpose of this study is to analyze the content of N,N-dimethylformamide(DMF) in polyurethane coated gloves(PU-gloves) and to assess the dermal exposure generated by wearing them. Methods: We analyzed the concentrations of DMF in 12 gloves by EN16778 standard. The samples cut into pieces of about 10 by 10 mm and extracted with methanol in flask in an ultrasonic bath at 70℃. An aliquot of the extract is analyzed with GC-MS. The dose of dermal exposure was calculated by ECETOC TRA consumer 3.1 and compared with derived no effect level(DNEL) for systemic effects due to long term exposure by workers. The extracted amount of DMF by saline solution was compared with that by EN16778 standard. Results: The mean concentration of DMF in PU-gloves was 1,377 mg/kg(range 13~3,948 mg/kg). The concentration of DMF showed significantly differences by packing type, manufacturer, and price(p<0.05). The dose of dermal exposure was 0.0007~0.572 mg/kg body weight/day when the DMF content was 10~4,000 mg/kg. The DMF extracted by saline solution was around 11% for 8 hours. Conclusions: The risk of dermal exposure due to the residual DMF in the PU-gloves was not signifiant. But, the limit of 1,000 mg/kg in PU-gloves can be recommended for international standard and trading systems.

Technical Evaluation of Engineering Model of Ultra-Small Transmitter Mounted on Sweetpotato Hornworm

  • Nakajima, Isao;Muraki, Yoshiya;Mitsuhashi, Kokuryo;Juzoji, Hiroshi;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • 제9권2호
    • /
    • pp.145-154
    • /
    • 2022
  • The authors are making a prototype flexible board of a radio-frequency transmitter for measuring an electromyogram (EMG) of a flying moth and plan to apply for an experimental station license from the Ministry of Internal Affairs and Communications of Japan in the summer of 2022. The goal is to create a continuous low-dose exposure standard that incorporates scientific and physiological functional assessments to replace the current standard based on lethal dose 50. This paper describes the technical evaluation of the hardware. The signal of a bipolar EMG electrode is amplified by an operational amplifier. This potential is added to a voltage-controlled crystal oscillator (27 MHz, bandwidth: 4 kHz), frequency-converted, and transmitted from an antenna about 10 cm long (diameter: 0.03 mm). The power source is a 1.55-V wristwatch battery that has a total weight of about 0.3 g (one dry battery and analog circuit) and an expected operating time of 20 minutes. The output power is -7 dBm and the effective isotropic radiated power is -40 dBm. The signal is received by a dual-whip antenna (2.15 dBi) at a distance of about 100 m from the moth. The link margin of the communication circuit is above 30 dB within 100 m. The concepts of this hardware and the measurement data are presented in this paper. This will be the first biological data transmission from a moth with an official license. In future, this telemetry system will improve the detection of physiological abnormalities of moths.

Design and heat transfer optimization of a 1 kW free-piston stirling engine for space reactor power system

  • Dai, Zhiwen;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2184-2194
    • /
    • 2021
  • The Free-Piston Stirling engine (FPSE) is of interest for many research in aerospace due to its advantages of long operating life, higher efficiency, and zero maintenance. In this study, a 1-kW FPSE was proposed by analyzing the requirements of Space Reactor Power Systems (SRPS), of which performance was evaluated by developing a code through the Simple Analysis Method. The results of SAM showed that the critical parameters of FPSE could satisfy the designed requirements. The heater of the FPSE was designed with the copper rectangular fins to enhance heat transfer, and the parametric study of the heater was performed with Computational Fluid Dynamics (CFD) software STAR-CCM+. The Performance Evaluation Criteria (PEC) was used to evaluate the heat transfer enhancement of the fins in the heater. The numerical results of the CFD program showed that pressure drop and Nusselt number ratio had a linear growth with the height of fins, and PEC number decreased as the height of fins increased, and the optimum height of the fin was set as 4 mm according to the minimum heat exchange surface area. This paper can provide theoretical supports for the design and numerical analysis of an FPSE for SRPSs.

A Review on Multidecadal Coastal Changes at Funafuti, Tuvalu from 1897 to 2015

  • Ahmed, Harun-Al-Rashid;Chan-Su, Yang
    • 대한원격탐사학회지
    • /
    • 제39권1호
    • /
    • pp.23-45
    • /
    • 2023
  • Tuvalu is a small reef islands country in the Pacific Ocean. Its coastal regions are very much dynamic due to the profound effects of tropical cyclones and sea level rise (SLR). However, research works on coastline dynamics of Tuvalu mainly cover its capital, Funafuti. Therefore, this review summarizes the extent of long-term coastal changes in different islets of Funafuti and on overall Tuvalu. In Funafuti, highly accreting areas are Te Afualiku, Fuafatu, Motugie, and Amatuku, and highly eroding areas are Fuagea and Tefala with the fully disappeared islet of Vasafua after 2005. However, in spite of different causes and supposition of scientists on disappearing these lands the accretion is more dominant than erosion which resulted in 7.3% net increase of land areas of Tuvalu over 117 years till 2015. Severe tropical cyclones mainly caused accretion of land areas by forming coral rubble rampart formation and further reworks and erosion to small sandy islands whereas frequent low-energy cyclones mainly caused erosion. Though, till now severe erosion of coastal areas are not evident by global SLR, islets of Funafuti experienced remarkable shoreline increase as formation of 30-40 m wide rubble rampart formation along 19 km in 1971 by tropical cyclone Bebe and net increase of area of 3.45 ha by tropical cyclone Pam in 2015. In spite of such overall accretion of coastal areas several scientists suspect drowning of its areas in future because of high SLR (~5.1±0.7 mm/year) at Funafuti which supposedly will not work as a breakwater anymore. Thus, protection measures should be taken to prevent coastline erosion as well as land reclamation activities should be done following the global examples.

한국의 희귀 나비가오리[Gymnura japonica (나비가오리과, 연골어강)]의 분류학적 재검토 (Taxonomic Review of a Rare Butterfly Ray Gymnura japonica (Gymnuridae, Chondrichthyes), in Korea)

  • 김진구;유정화;장서하;한경호;김병엽
    • 한국수산과학회지
    • /
    • 제55권1호
    • /
    • pp.30-36
    • /
    • 2022
  • We collected a total of four butterfly ray specimens (Gymnura japonica, 213.4-695.0 mm in total length) in Korea from 2016 to 2021 and investigated their morphological and molecular characteristics in order to clarify their taxonomic status. These features are summarized as follows. Disc lozenge-shaped, 1.8-2.0 times broader than long. Tail very short, post-cloaca length 23.9-28.2% in disc width. Snout short, no rostral cartilage. Clasper short, no hook. Dorsal surface uniform yellow or brownish grey, with or without rounded light yellow spots. An analysis of 434 base-pair sequences of mitochondrial DNA cytochrome c oxidase subunit I showed that all four specimens corresponded to G. japonica from Japan (Kimura-2-parameter distance = 0-0.2%), suggesting that the color patterns found may be due to intraspecific color variation. G. japonica resembles Gymnura poecilura but differs in that it has a shorter tail length to disc width (23.9-28.2% in G. japonica vs. 40.1-48.3% in G. poecilura). This study revealed that G. japonica occurred in areas affected by the Tsushima Warm Current, tentatively suggesting that G. japonica may be an indicator species for monitoring marine ecosystem changes due to climate change.