• 제목/요약/키워드: mixture flow rate

검색결과 463건 처리시간 0.03초

A rheo-optical investigation of shear-induced morphological changes in biopolymeric blends

  • Puyvelde, P.Van;Antonov, Y.A.;Moldenaers, P.
    • Korea-Australia Rheology Journal
    • /
    • 제14권3호
    • /
    • pp.115-119
    • /
    • 2002
  • In this paper, a rheo-optical methodology based on small angle light scattering and polarimetry is applied to investigate in-situ and on a time resolved basis the flow-induced structures in aqueous biopolymeric blends. Water-dextran-gelatin is chosen as an example. It is verified to what extent the laws and scaling relations, originally developed for synthetic polymer blends, are valid for the morphology development in this aqueous biopolymeric mixture. It was observed that under low shear rate conditions, the biopolymeric emulsion can be regarded as a conventional emulsion. However, at high shear rates flow induced homogenization occurs.

아르곤 가스를 효율적으로 사용하기 위한 GMA 용접 토치 구조 Part 1 : AMAG와 DMAG 토치가 아르곤 조성에 미치는 영향 (GMA Torch Configuration for Efficient Use of Argon Gas Part 1 : Effects of AMAG and DMAG Torches on Argon Composition)

  • 최상균;문명철;유중돈
    • Journal of Welding and Joining
    • /
    • 제17권6호
    • /
    • pp.38-45
    • /
    • 1999
  • Shielding gas has significant effects on arc stability, metal transfer and weld quality in the gas metal arc welding (GMAW) process. The double gas-shielded MAG(DMAG) and auxiliary gas-shielded MAG (AMAG) torches are investigated for their capability to provide argon-rich gas mixture using small amount of argon gas through the inner and auxiliary nozzles, respectively. Argon composition with the DMAG torch is calculated numerically, and compared with the measured data using the gas chromatogrphy. Gas flow pattern of the DMAG torch is calculated to change from the laminar to turbulent flow when total gas flow rate becomes larger than 4.5 liter/min at room temperature. While argon-rich shielding gas was obtained using both the AMAG and DMAG torches, the AMAG torch provides higher argon composition than the DMAG torch, which demonstrates that argon gas can be utilized more efficiently with the AMAG torch.

  • PDF

가연성 유해가스 처리를 위한 연소기 개발 (Development of Combustor for Combustible Hazardous Gas)

  • 전영남;채종성;김미환
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.479-485
    • /
    • 1996
  • Volatile organic compounds are air pollutants exhausting from industrial process, evaporation of solvent, and so on. Most of VOCs are the combustible gas of low calorific value as it is diluted by air. The systems burning such a hazardous gas need to increase enthalpy in order to increase flame stability. In this study an incinerator with reciprocating flow in the honeycomb ceramic has been used for the experiment of VOCs control. By the reciprocating flow system, the enthalpy of combustion gas is effectively regenerated into the enthalpy increases of the combustible gas through the honeycomb ceramic, which provides a heat storage. The position of the reaction zone is strongly dependent on the parameters of mixture velocity and time frequency. Flame front is changed to the point where burning velocity is coincided with burning velocity in the honeycomb ceramic. In this system it is important that flame front should be located symmetrically at the center of honeycomb ceramic for the purpose of increasing the reaction rate at one point. Peak temperature becomes higher with decreasing time frequency, at which the flow direction is regularly reversed.

  • PDF

침지형 MBR 공정의 공기 세정 최적화를 통한 효율적 막 오염 제어 (Optimization of air scouring for an effective control of membrane fouling in submerged MBR)

  • 김준영;백병도;장인성
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.645-652
    • /
    • 2016
  • A membrane module including grid was designed and introduced to MBR (membrane bio-reactor) for the purpose of better control of membrane fouling. It could be anticipated that the grid enhances the shear force of fluid-air mixture into the membrane surface by even-distributing the fluid-air to the membrane module. As MLSS concentration, packing density which is expressed in the ratio of the housing and the cross-sectional area of membrane fibers ($A_m/A_t$) and air-flow rate were changed, membrane foulings were checked by monitoring fouling resistances. The total fouling resistance ($R_c+R_f$) without grid installation (i.e., control) was $2.13{\times}10^{12}m^{-1}$, whereas it was reduced to $1.69{\times}10^{12}m^{-1}$ after the grid was installed. Regardless of the grid installation, the $R_c+R_f$ increased as the packing density increased from 0.09 to 0.28, however, the increment of resistance for the grid installation was less than that of the control. Increase in the air flow rate did not always guarantee the reduction of fouling resistance, indicating that the higher air flow rate can partially de-flocculate the activated sludge flocs, which led to severer membrane fouling. Consequently, installation of grids inside the housing have brought a beneficial effect on membrane fouling and optimum air flow rate is important to keep the membrane lowering fouling.

VS/VD스위치의 ABR 서비스 향상을 위한 흐름 제어 알고리즘 (Flow Control Algorithm for ABR Service in VS/VD Switch)

  • 정광일;온종렬;전병실
    • 한국음향학회지
    • /
    • 제18권6호
    • /
    • pp.65-70
    • /
    • 1999
  • ATM망에는 QoS 요구에 따라 CBR, rt-VBR, nrt-VBR, UBR, ABR과 같은 여러 트래픽이 존재하는데, 특히 ABR 트래픽 관리에 대해서 많은 연구가 진행되고 있다. ABR은 CBR/VBR이 쓰고 남은 여분의 대역폭을 사용하는데, 그 대역폭을 효율적으로 사용하고자 많은 흐름 제어 방식이 제안되고 있다. ATM Forum의 트래픽 관리 WG(Working Group)에서는 ABR 서비스의 흐름 제어 관리를 위하여 rate-based와 credit-based, 그리고 이 두가지 방식을 혼합한 방식이 있는데, 이 중 rate-based 방식이 유동적이며 저가격·고용량의 스위치를 구현할 수 있다는 장점을 가지고 있어 표준으로 채택되어 사용되고 있다. 본 논문에서는 rate-based 방식에서 EFCI, ER과 VS/VD(Virtual Source/Virtual Destination)등을 이용한 스위치에 대해서 알아보고, VS/VD 방식에서 쓰던 큐 임계값 방식 대신 스위치 입력단에 입력 대역폭 임계값을 이용한 흐름제어 방식을 제안하고 기존의 EPRCA 알고리즘을 응용하여 효율적으로 ABR 트래픽을 관리할 수 있는 새로운 알고리즘을 제안한다.

  • PDF

부분적 예혼합화염제어에 의한 연소 라디칼 및 NOx 배출물 특성 (Combustion Radicals and NOx Emissions Characteristics by Control of Partially Premixed Flames)

  • 김태권;장준영
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.561-569
    • /
    • 2002
  • This paper presents an investigation on $C_2$, CH, OH radicals and NOx emissions in partially premixed flames with acoustic excitation. The radicals are visualized by the digital image technique with optical filters and ICCD camera while NOx emissions are determined by a chemiluminescent detection(NOx analyser). The measurements are made in flames with an overall equivalence ratio (${\phi}_o$) 0.5 and a center tube equivalence ratio(${\phi}_c$) varing from 1.1 to 5.0 for a constant fuel flow rate. In the case of excitation, the visual shape of the flame is changed from laminar to turbulent-like flames. Images of $C_2$, CH, and OH radicals resemble those of the flame appearances as the excitation phase is varied, and the radicals generated at the upstream are convected toward the downstream. It is inferred that the flame characteristics is affected by the flow characteristics of air-fuel mixture. In the case of acoustic excitation, OH radicals are much increased relative to unexcitation. From the radicals and flame visualization under acoustic excitation, the reduction of flame length affects the shorter residence time of center tube mixture, and significantly influences the NOx reduction.

Growth and Properties of CrNx/TiNy/Al Based on N2 Gas Flow Rate for Solar Thermal Applications

  • Ju, Sang-Jun;Jang, Gun-Eik;Jang, Yeo-Won;Kim, Hyun-Hoo;Lee, Cheon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권3호
    • /
    • pp.146-149
    • /
    • 2016
  • The CrN/TiN/Al thin films for solar selective absorber were prepared by dc reactive magnetron sputtering with multi targets. The binary nitride CrN layer deposited with change in N2 gas flow rates. The gas mixture of Ar and N2 was an important parameter during sputtering deposition because the metal volume fraction (MVF) was controlled by the N2 gas flow rate. In this study, the crystallinity and surface properties of the CrN/TiN/Al thin films were estimated by X-ray diffraction (XRD), atomic force microscopy (AFM) and field emission scanning electron microscopy (FESEM). The composition and depth profile of thin films were investigated using Auger electron spectroscopy (AES). The absorptance and reflectance with wavelength spectrum were recorded by UV-Vis-NIR spectrophotometry at a range of 300~1,100 nm.

Corrosion Behavior of Stainless Steel 316 for Carbon Anode Oxide Reduction Application

  • Jeon, Min Ku;Kim, Sung-Wook;Choi, Eun-Young
    • 방사성폐기물학회지
    • /
    • 제18권2호
    • /
    • pp.169-177
    • /
    • 2020
  • Here, the stability of stainless steel 316 (SS-316) was investigated to identify its applicability in the oxide reduction process, as a component in related equipment, to produce a complicated gas mixture composed of O2 and Cl2 under an argon (Ar) atmosphere. The effects of the mixed gas composition were investigated at flow rates of 30 mL/min O2, 20 mL/min O2 + 10 mL/min Cl2, 10 mL/min O2 + 20 mL/min Cl2, and 30 mL/min Cl2, each at 600℃, during a constant argon flow rate of 170 mL/min. It was found that the corrosion of SS-316 by the chlorine gas was suppressed by the presence of oxygen, while the reaction proceeded linearly with the reaction time regardless of gas composition. Surface observation results revealed an uneven surface with circular pits in the samples that were fed mixed gases. Thermodynamic calculations proposed the combination of Fe and Ni chlorination reactions as an explanation for this pit formation phenomenon. An exponential increase in the corrosion rate was observed with an increase in the reaction temperature in a range of 300 ~ 600℃ under a flow of 30 mL/min Cl2 + 170 mL/min Ar.

R32를 포함한 R22 대체 혼합냉매의 모세관 유동 특성 (Flow Characteristics of Refrigerant Mixtures with R32 in a Capillary Tube)

  • 장세동;노승탁
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.177-186
    • /
    • 1996
  • The characteristics of the flow of pure HFC refrigerants(R32, R125, and R134a) and their mixtures through capillary tubes were investigated experimentally. Two capillary tubes with 1.2mm and 1.6mm inner diameter and 1.5m length were adopted as test sections. Mass flow rates and temperatures and pressures were measured for several condensing temperatures and degrees of subcooling at capillary tube inlet. The effects of the condensing temperature, inner diameter of capillary tube, and subcooling on the mass flow rate of refrigerants were discussed, and the mass flow rates of HFC refrigerants were compared with that of R22. The pressure and temperature distributions along the capillary tube compared with that of R22. The pressure and temperature distributions along the capillary tube show that there is a metastable equilibrium state in the flow through the tube. Underpressure for vaporization increases as refrigerant mass flux increases and inlet subcooling decreases. Empirical correlation was suggested to predict underpressure for vaporization of the HFC refrigerants.

  • PDF

Performance Evaluation of Double-Tube Condenser using Smooth and Micro-Fin Tubes for Natural Mixture Refrigerant (Propane/Butane)

  • Lee, Sang-Mu;Lee, Joo-Dong;Koyama, Shigeru;Park, Byung-Duck
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권1호
    • /
    • pp.25-33
    • /
    • 2007
  • The investigation has been made into the prediction of heat exchange performance of a counter flow type double-tube condenser for natural refrigerant mixtures composed of Propane/n-Butane or Propane/i-Butane in a smooth tube and micro-fin tube. Under various heat transfer conditions, mass flux, pressure drop and heat transfer coefficient of the mixed refrigerants were calculated using a prediction method, when the length of condensing tube, total heat transfer rate, mass flux and outlet temperature of coolant were maintained constant. Also, the predicted results were compared with those of HCFC22. The results showed that the mixed refrigerants of Propane/n-Butane or Propane/i-Butane could be substituted for HCFC22, while the pressure drop and overall heat transfer coefficient of the refrigerants were evaluated together.