• Title/Summary/Keyword: mixed-mode chromatography

Search Result 18, Processing Time 0.026 seconds

Optimization of solid-phase extraction for the liquid chromatography-tandem mass spectrometry analysis of basic drugs in equine urine (액체크로마토그래피-텐덤질량분석법을 위한 경주마 소변 중 염기성 약물의 고체상 추출법 최적화)

  • Shin, Hyun Du;Yang, Ji Suk;Jung, Mihye;Kim, Hyung-Seung;Youm, Jeong-Rok;Hu, Man Bae;Kim, Sung Jean;Han, Sang Beom
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.412-423
    • /
    • 2008
  • A procedure based on solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry has been developed for the simultaneous analysis of 55 basic drugs in equine urine. The test scope covers diversified classes of drugs including some ${\beta}$-blockers, ${\beta}$-agonists, antihypotensives, CNS stimulants, sedatives, tranquilizers, antidepressants, antihypertensives and so on. LC-MS/MS separation and quantification was carried out in positive electrospray ionization and multiple reaction monitoring (MRM) mode. Four different brands of mixed mode cation exchange SPE sorbents; UCT XTRACT$^{(R)}$ XRDAH, Supelco DSC-MCAX$^{(R)}$, Varian Bond Elut Certify$^{(R)}$ and Waters Oasis$^{(R)}$ MCX were compared. The UCT XTRACT$^{(R)}$ XRDAH sorbent provided the best results in the preconcentration of samples, yielding relative recoveries higher than 80% except for terbutaline (41.3%), salbutamol (71.5%), heptaminol (70.7%), phenylpropanolamine (66.3%). Detection limits of the target drugs provided by the proposed analytical procedure were between 0.2~8.3 ng/mL.

Quantitative Change of Aristolochic Acid Contents by Processing Methods on the Plants of Aristolochiaceae (쥐방울과 한약의 수치에 따른 aristolochic acid 함량변화)

  • Kim, Min-Suk;Lee, Joung-Bok;Park, Si-Hyung;Kim, Dong-Wook;Min, Oh-Jin;Rhyu, Dong-Young
    • Korean Journal of Pharmacognosy
    • /
    • v.38 no.2 s.149
    • /
    • pp.123-127
    • /
    • 2007
  • Aristolochic acid (AA) included in the plants Aristolochiaceae have been well known to be nephrotoxic and carcinogenic inducer and to cause renal disease such as Chinese Herb Nephropathy (CHN). In this study, we used a high performance liquid chromatopaphy-mass spectrometry (HPLC-MS) under the positive ion detection mode for the quantitative change of aristolochic acid-I and-II (AA-I and AA-II) in Aristolochiaceae (Aristolochia contorta Bunge, Aristolochia debilis Sieb. et Zucc., Aristolochia fangchi Wu), some related plants (Cocculus trilobus De candolle, Inula helenium Linne, Saussurea lappa Clarke), and its prescriptions (防己茯笭湯, 定喘散) with or without processing. Here, the processing methods and prescriptions in oriental medicine were generally used to alleviate toxicity or alter property of herbal medicines. However, the concentrations of AA-I and AA-II were highly determined in processed material extracts rather than unprocessed those, not measured in some related plants. Also, the concentrations of AA-I and AA-II even at the prescriptions mixed the plants of Aristolochiaceae were detected to range from 0.73 to 2.53 ppm. Thus, the present results suggest that the content of AA-I and AA-II contained to plants of Aristolochiaceae was not reduced by the processing methods or prescriptions which can induce the physico-chemical change and pharmacological transformation in traditional herbal medicines.

Antioxidant and α-Glucosidase Inhibitory Activities of the Extracts of Aster koraiensis Leaves (국내산 벌개미취 잎 추출물의 α-glucosidase 억제능 및 항산화 활성 평가)

  • Lee, Tae Gu;Hyun, Soo Wang;Lee, Ik Soo;Park, Bong Kyun;Kim, Jin Sook;Kim, Chan Sik
    • Korean Journal of Medicinal Crop Science
    • /
    • v.26 no.5
    • /
    • pp.382-390
    • /
    • 2018
  • Background: The plant Aster koraiensis has long been used as an ingredient in folk medicine. It has been reported that Aster koraiensis extract (AKE) prevents the progression of diabetes-induced retinopathy and nephropathy. However, although these beneficial effects of AKE on diabetes complications have been identified, the antidiabetic effects of AKE have not yet been completely investigated and quantified. In the present study, the glucose-lowering and antioxidant effects of aqueous and ethanolic AKEs were evaluated. Methods and Results: The glucose-lowering effects of aqueous and ethanolic (30%-, 50%-, and 80%-ethanol) AKEs were investigated via ${\alpha}$-glucosidase inhibitory assays. The mode of inhibition by AKEs on ${\alpha}$-glucosidase was identified through kinetic analysis. The total antioxidant capacity of each of the 4 AKEs was evaluated by assessing their conversion rate of $Cu^{2+}$ to $Cu^+$. The content of chlorogenic acid and 3,5-di-O-caffeoylquinic acid, the bioactive compounds in AKE, in each extract were analyzed by high performance liquid chromatography (HPLC). The AKEs showed potent ${\alpha}$-glucosidase inhibitory activity with mixed inhibition mode, and significant antioxidant capacity. Conclusions: These results of this study suggested that the AKEs tested had ${\alpha}$-glucosidase inhibitory and antioxidant effects. Among the extracts, the 80% ethanol extract showed the most significant ${\alpha}$-glucosidase inhibitory activity, with a half maximal inhibitory concentration ($IC_{50}$ value) of $1.65{\pm}0.36mg/m{\ell}$ and a half maximal effective concentration ($EC_{50}$ value) for its antioxidant activity of $0.42{\pm}0.10mg/m{\ell}$. It can therefore be used as a source of therapeutic agents to treat diabetes patients.

Development and Validation of the Determination of Sorafenib in Human Plasma using Tandem Mass Spectrometry Coupled with Liquid Chromatography (고속액체크로마토그래피 텐덤질량분석기법을 이용한 사람 혈장 내 소라페닙 농도분석법의 개발 및 검정)

  • Park, Daejin;Lee, Sunggon;Kim, Woomi
    • Journal of Life Science
    • /
    • v.22 no.11
    • /
    • pp.1456-1462
    • /
    • 2012
  • Sorafenib is a multikinase inhibitor and an oral anticancer drug approved for the treatment of patients with advanced renal cell carcinoma and those with unresectable hepatocellular carcinoma. The purpose of this study was to develop an efficient method of the determination of sorafenib in human plasma using tandem mass spectrometry coupled with liquid chromatography (LC/MS/MS) and validate the method by the guidelines of the Korean Food and Drug Administration (KFDA). Plasma samples ($100{\mu}l$) were added with chlorantraniliprole as an internal standard and then mixed with the 0.1% formic acid-containing extraction solution composed of isopropyl alcohol and ethyl acetate (1:4, v/v). After centrifugation, the supernatant was concentrated at $45^{\circ}C$ under negative pressure and centrifugal force. The residue was reconstituted with a mobile phase and injected into the HPLC instrument using a reverse phase Waters XTerra$^{TM}$ C18 column (particle size $3.5{\mu}m$). Liquid chromatography was carried out within the run time of 5 min using a mobile phase composed of buffer (0.1% formic acid and 10 mM ammonium formate), methanol, and acetonitrile (1:6:3, v/v/v). The analytes were monitored by tandem mass spectrometry in the multiple reaction monitoring method programmed to detect sorafenib at 'm/z 465.2 ${\rightarrow}$ 252.5' and chlorantraniliprole at 'm/z 484.4 ${\rightarrow}$ 286.2' with positive electrospray ionization mode ($ES^+$). The result showed the proper linearity ($r^2$ > 0.99) over the range of 2,000-5,000 ng/ml with good accuracy (90.7-103.9%) and precision (less than 10%). The newly developed method using LC/MS/MS was validated by the guideline of KFDA and identified as more sensitive compared to the previous methods.

Analysis of Methamphetamine and Amphetamine in Oral Fluid of Eleven Drug Abusers (마약남용자 11명의 타액 중 메스암페타민의 분석)

  • Kim, Eun-Mi;Lee, Ju-Seon;Choi, Hye-Young;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.419-425
    • /
    • 2008
  • A qualitative and quantitative analytical method was developed for detection of methamphetamine (MA) and its main metabolite amphetamine (AM) in oral fluid. Oral fluids of eleven drug abusers were provided by Police, specimens were collected by stimulation with a cotton swab treated with 20 mg of citric acid ($Salivette^{(R)}$; Sarstedt, USA). As the preliminary test, oral fluid samples were screened for amphetamines by Fluorescence Polarization Immunoassay (TDxFLx, Abbott Co.). Extraction for MA was performed using solid-phase extraction (SPE) by $RapidTrace^{TM}$ (Zymark, USA) with mixed mode cation exchange cartridge, CLEAN $SCREEN^{(R)}$ (130 mg/3 ml, UCT) after dilution with phosphate buffer. Samples were evaporated and derivatized by pentafluoropropionic acid anhydride (PFPA). Quantitation of MA and AM was performed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM), the quantitation ions were m/z 204 (MA), 208 (MA-$D_5$), 190 (AM) and 194 (AM-$D_5$). The selectivity, linearity of calibration, limit of detection (LOD) and quantification (LOQ) within- and between day precision, accuracy and recoveries were examined as parts of the method validation. All oral fluid samples gave positive results to immunoassay for MA (cut-off level, 50 ng/ml as d-amphetamine). Concentrations of MA and AM by GC-MS in eleven samples were ranged 104.2${\sim}$4603.3 ng/ml and 32.4${\sim}$268.6 ng/ml, respectively. Extracted calibration curves of MA and AM were linear over the two concentration range of 1${\sim}$100 and 50${\sim}$1000 ng/ml with correlation coefficient of above 0.999. LOQ of MA and AM was 1 and 3 ng/ml, respectively. The intraand inter-day run precisions (CV) for MA and AM were less than 10%, and the accuracies (bias) for MA and AM were also less than 10% at the two different concentrations 5 and 100 ng/ml at low calibration range, 50 and 1000 ng/ml at high calibration range. The absolute recoveries of MA and AM at low and high calibration ranges were more than 82% and 75%, respectively. In this study the qualitative and quantitative analytical method of MA in oral fluid was established. Oral fluid testing may detect drug use in past hours because of its shorter detection window than urine, and be useful in post-accident situations. So oral fluids will be most useful for testing drug abuse in the driving under the influence of drug (DUID) as the alternative specimens of urine.

A sensitive analytical method for determination of 3-monochloropropane-1,2-diol and 1,3-dichloropropan-2-ol in various foods by gas chromatography with mass spectrometer (가스크로마토그래피/질량분석기를 이용한 식품 중 클로로프로판올 화합물 분석)

  • Kim, Eunju;Park, Sungkug;Choi, Dongmi
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.543-552
    • /
    • 2008
  • This paper described the relatively sensitive and simultaneous analytical method for 3-monochloropropane-1,2-diol (3-MCDP, $C_3H_7ClO_2$, MW. 110) as well as 1,3-dichloropropan-2-ol (1,3-DCP, $C_3H_6Cl_2O$, MW. 128) in various foods. Food samples were homogenized in 5M NaCl solution, mixed with aluminum oxide and eluted with dichloromethane. The extracted chloropropanols were concentrated by rotary evaporator and $N_2$ blow serially were derivatized with HFBA (Heptafluorobutyric anhydride, $C_8F_{14}O_3$, MW. 410) and were determined by GC/MS using isotope dilution method. The characteristic molecular ions at m/z 253, 275, 289, 291, and 453 for HFBA derivatives of 3-MCPD (MW. 502) and 110, 275, and 277 for HFBA derivatives of 1,3-DCP (MW. 325) were chosen in selected ion mode. The method validation data showed sufficiently good properties of LOD (0.003 mg/kg), LOQ (0.010 mg/kg), linearity ($R^2{\geq}0.999$ at 0.010~1.000 mg/kg), and recovery rate (${\approx}97%$). The levels of chloropropanols in soy sauce, sauces, processed meat products, fishery products, and seasonings (n=56/157) determined by the presented method were 0.0~0.3 mg/kg.

Optimization of HPLC Method and Clean-up Process for Simultaneous and Systematic Analysis of Synthetic Color Additives in Foods (식품 중 타르색소의 동시분석 및 계통분석을 위한 HPLC 분석조건 및 정제과정 확립)

  • Park, Sung-Kwan;Hong, Yeun;Jung, Yong-Hyun;Lee, Chang-Hee;Yoon, Hae-Jung;Kim, So-Hee;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.33-39
    • /
    • 2001
  • To develop a method for separation process using Sep-pak $C_18$, simultaneous and systematic analysis of 8 permitted and 11 non-permitted synthetic food colors in Korea, optimization of analysis conditions for reverse phase ion-pair high performance liquid chromatography was carried out. For the best result of Sep-pak $C_18$ separation the pH of color standard mixture solution was $5{\sim}6$ and 0.1% HCl-methanol solution were set as eluent. The colors eluated from Sep-pak $C_18$ cartridge were determined and confirmed by high performance liquid chromatography with a photodiode array detector at 420 nm for yellow colors type, at 520 nm for red colors type, at 600 nm for blue and green colors type and at 254 nm for mixed colors. Conditions for HPLC analysis were as follows: column, Symmetry $C_18$ (5 m, 3.9 mm $i.d.{\times}150\;mm$); mobile phase, 0.025 M ammonium acetate (containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (65 : 25 : 10) and 0.025 M ammonium acetate(containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (40 : 50 : 10); flow rate, 1 mL/min. It takes 35 minutes for simultaneaus analysis and 18 minutes for systematic analysis. The detection limits range of each colors were $0.01{\sim}0.05\;{\mu}g/g$.

  • PDF

Simultaneous Determination of Aminoglycoside Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 아미노글리코사이드계 항생제 9종의 동시분석 및 적용성 검증)

  • Cho, Yoon-Jae;Choi, Sun-Ju;Kim, Myeong-Ae;Kim, MeeKyung;Yoon, Su-Jin;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.123-130
    • /
    • 2014
  • A simultaneous determination was developed for 9 aminoglycoside antibiotics (amikacin, apramycin, dihydrostreptomycin, gentamicin, hygromycin B, kanamycin, neomycin, spectinomycin, and streptomycin) in meat by liquid chromatography tandem mass spectrometry (LC-MS/MS). Each parameter was established by multiple reaction monitoring in positive ion mode. The developed method was validated for specificity, linearity, accuracy, and precision based on CODEX validation guideline. Linearity was over 0.98 with calibration curves of the mixed standards. Recovery of 9 aminoglycosides ranged on 60.5~114% for beef, 60.1~112% for pork and 63.8~131% for chicken. The limit of detection (LOD) and limit of quantification (LOQ) were 0.001~0.009 mg/kg and 0.006~0.03 mg/kg, respectively in livestock products including beef, pork and chicken. This study also performed survey of residual aminoglycoside antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Aminoglycosides were not found in any of the samples.