• Title/Summary/Keyword: mixed solvents

Search Result 226, Processing Time 0.024 seconds

Ion-Pair Chromatography of Benzoic Acid and Its Derivatives on XAD-2 (XAD-2 지지체를 이용한 벤조산과 그 유도체들의 이온쌍 크로마토그래피에 관한 연구)

  • Kang, Sam-Woo;Ryu, Sam-Gon;Park, Young-Kyu
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.176-184
    • /
    • 1984
  • Retention behavior of benzoic acid and its derivatives on XAD-2 in the alcoholic aqueous solution was investigated and separation was attempted. Retention was affected by the concentration and kinds of added organic solvents, the pH of the aqueous solution, the added $R_4N^+$ and the position and kinds of functional group in the sample molecules. Retention of sample acids in acidic conditions was due to mainly molecular adsorption on nonpolar XAD-2 surface and that in basic conditions was due to mainly ion-pair model. In these bases a mixed sample was separated in EtOH 20% aqueous solution at pH 8.50.

  • PDF

Preparation and Characterization of a Layered Organic-inorganic Composite by the Electrophoretic Deposition of Plate-shaped Al2O3 Particles and Electrophoretic Resin (전기영동적층법을 통한 판상 알루미나 입자와 전기영동 수지의 배향 유무기 복합체 제조 및 물성평가)

  • Park, Hee Jeong;Lim, Hyung Mi;Choi, Sung-Churl;Kim, Younghee
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.460-465
    • /
    • 2013
  • Plate-shaped inorganic particles are coated onto a stainless steel substrate by the electrophoretic deposition of a precursor slurry which includes the inorganic particles of $Al_2O_3$ and polymer resin in mixed solvents to mimic the abalone shell structure, which is a composite of plate-shaped inorganic particles and organic interlayer binding materials with a layered orientation. The process parameters of the electrophoretic deposition include the voltage, coating time, and conductivity of the substrate. In addition, the suspension parameters are the particle size, concentration, viscosity, conductivity, and stability. We prepared an organic-inorganic composite coating with a high inorganic solid content by arraying the plate-shaped $Al_2O_3$ particles and electrophoretic resin via an electrophoretic deposition method. We analyzed the effect of the slurry composition and the electrophoretic deposition process parameters on the physical, mechanical and thermal properties of the coating layer, i.e., the thickness, density, particle orientation, Young's modulus and thermogravimetric analysis results.

Study on Solvent Mediated Phase Transformation Kinetics of Hexanitrohexaazaisowurtzitane(HNIW) (용매를 매체로 한 Hexanitrohexaazaisowurtzitane(HNIW)의 상전이 속도에 관한 연구)

  • 김준형;임유진
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.9-17
    • /
    • 2000
  • The crystal growth and dissolution rates were calculated by solving a model equation, which involved the dissolution of the metastable phase($\beta$-HNIW) and growth of the stable phase($\varepsilon$-HNIW), together with the mass balance equation. The model has been successfully used to simulate available kinetic data for the $\beta$$\longrightarrow$$\varepsilon$ polymorphic transformation via a solution phase. From the effectiveness factor based on the two-step model, it was found that the surface integration contribution to the process was comparatively small, and a diffusion dependency decreased with an increase of the mass fraction of chloroform in the mixed solvents of ethyl acetate and chloroform. Appling these kinetics in process simulation allowed for the prediction of the product size of $\varepsilon$-HNIW.

  • PDF

Volatile organic compounds emitted from printing processes and their removal by adsorption (인쇄업에서 배출되는 반응성 VOCs 종류와 흡착 제거 방법의 적용)

  • Ahn, Hae Young;Lee, Yoon Kyoung;Song, Ji Hyeon
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.396-403
    • /
    • 2018
  • In this study, volatile organic compounds (VOCs) emitted from printing industries were analyzed, and an inorganic adsorbent, ${\gamma}-alumina$, was selected for the effective control of the VOC emissions. Printing processes commonly require inks, thinners, and cleaners, and they were mixed organic solvents containing aromatic compounds, ketones, and alcohols. Therefore, toluene, methyl ethyl ketone (MEK), and isopropyl alcohol (IPA) were selected as model compounds for this study. The adsorptive properties using ${\gamma}-alumina$ were determined for the model compounds. Both batch isotherm and continuous flow column tests demonstrated that the adsorption capacity of MEK and IPA was 3~4 times higher than that of toluene. The column test performed at an inlet toluene concentration of 100 ppm showed that an 80% breakthrough for toluene was observed after 3 hours, but both MEK and IPA were continuously adsorbed during the same time period. A numerical model simulated that the ${\gamma}-alumina$ could remove toluene at a loading rate of 0.4 mg/min only for a 4-hour period, which might be too short of a duration for real applications. Consequently, lifetime enhancement for ${\gamma}-alumina$ must be implemented, and ozone oxidation and regeneration would be feasible options.

Manufacturing and Characterization of Ophthalmic Materials Using 2D Transition Metal Carbide

  • Seon-Young Park;A-Young Sung
    • Journal of Integrative Natural Science
    • /
    • v.17 no.3
    • /
    • pp.67-73
    • /
    • 2024
  • Hydrophilic contact lens was prepared by dispersing MXene material in a hydrogel mixture, and the purpose of this study was to evaluate its properties as an ophthalmic material. The MXene used in the experiment was manufactured through an etching process using titanium aluminum carbide 312 [Ti3AlC2] and hydrofluoric acid [HF]. For the preparation of hydrophilic contact lenses, 2-hydroxyethyl methacrylate [HEMA], a photoinitiator 2-hydroxy-2-methylpropiophenone [2H2M], and a cross-linker Ethylene glycol dimethacrylate [EGDMA] were used, and UV-rays was irradiated for 50 seconds for photopolymerization. Optical transmittance, refractive index, water content, contact angle, electromagnetic wave shielding ability, and photo-thermal conversion effect were measured to evaluate the physical properties of the manufactured contact lens. Compared to MXene materials, MXene mixed with Dimethyl sulfoxide [DMSO] had superior dispersion ability in organic solvents, and the transparency of the prepared hydrophilic contact lenses was high. MXene did not significantly affect the refractive index and water content, and improved the wettability of the contact lens. In addition, the MXene material used as an additive showed electromagnetic wave shielding ability and photo-thermal conversion effect based on its excellent electrical conductivity. It is judged that the mixture using MXene as an additive can be used as a functional contact lens material for electromagnetic wave shielding and ocular photo-thermal therapy.

Neurobehavioral Performance Test of Workers Exposed to Mixed Organic Solvents (복합유기용제에 폭로된 근로자들에 대한 신경행동학적 기능의 평가)

  • Kim, Chang-Youn;SaKong, Joon;Chung, Jong-Hak;Joo, Ree;Jeon, Man-Joong;Sung, Nag-Jung;Kim, Sang-Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.2
    • /
    • pp.314-328
    • /
    • 1997
  • A cross-sectional study was performed to evaluate the effects of chronic exposure to low-dose solvent on neurobehavioral performance of 48 male workers exposed to organic solvents. A control group of 50 workers was selected from same factories. Each worker completed a medical and occupational questionnaire and four tests of Neurobehavioral Core Test Battery. These included Benton visual retention test, digit symbol, digit span, and pursuit aiming. Comparison of mean performance showed a significantly poorer performance on digit symbol, digit span, and pursuit aiming. In univariate analysis, age contributed to poor performance on Benton visual retention test and educational level was found to reduce the performance on symbol digit in both groups. Amount of alcohol intake was found to reduce the performance on digit symbol and smoking appeared to slow pursuit aiming in the exposure group. In multiple regression analysis, controlling for age, educational level, alcohol, and smoking, Solvent exposure was found to be associated with performance of digit span, and number of correct dot of pursuit aiming. Age on Benton visual retention, educational level on digit symbol, arid smoking on pursuit aiming were found to be a significant factors on each test items. This study suggest that short-term memory, and perception can be affected easily by chronic exposure of organic solvents which air concentration levels were under the Threshold Limit Value.

  • PDF

1-Ethyl-1-Methyl Piperidinium Bis(Trifluoromethanesulfonyl)Imide as a Co-Solvent for Li-ion Battery Electrodes (혼합 용매로서의 1-Ethyl-1-Methyl Piperidinium Bis(Trifluoromethanesulfonyl)Imide의 리튬 이차 전지용 전극별 거동)

  • Koh, Ah Reum;Kim, Ketack
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.2
    • /
    • pp.103-110
    • /
    • 2014
  • In the study, a room temperature ionic liquids as a co-solvent was used to evaluate the feasibility with various electrodes in Li-ion batteries. 1-Ethyl-1-methyl piperidinium bis(trifluoromethanesulfonyl) imide(PP12 TFSI) is an ionic liquid that melts at $85^{\circ}C$. Pure PP12 TFSI is not able to be used as an electrolyte because it is a solid salt at room temperature. PP12 TFSI is mixed with EC/DEC(1/1 vol.%) to prepare mixed solvents. The electrolyte 1.5M $LiPF_6$ in a mixed solvent having 44 wt.% PP12 TFSI is prepared to evaluated the various electrodes. The electrolytes provides good cycles life of cells with $LiNi_{0.5}Mn_{1.5}O_4(LNMO)$, $LiFePO_4(LFP)$, $Li_4Ti_5O_{12}(LTO)$ and artificial graphite. Further improvement of the cell performances can be accomplished by enhancing wettability of electrolytes to electrodes.

Development of Solvent System for Enzymatic Synthesis of N-Benzoylaspartame (N-Benzoylaspartame의 효소적 합성을 위한 용매계의 선정)

  • Han, Min-Su;Kim, Woo-Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.504-510
    • /
    • 1992
  • Several single or mixed water-miscible organic solvent systems were investigated to develop the most effective solvent system for enzymatic synthesis of N-benzoylaspartame(BzAPM). The BzAPM was prepared by immobilized thermolysin with using N-benzoyl-L-aspartic acid(Bz-Asp) and L-phenylalanine methyl ester(PheOMe). The solubilities of BzAPM and L-phenylalanine were highest in 4.5% methanol(1.89 and 1.79%, respectively) among the solvents system investigated while a mixed solvent system of 25% dimethyl sulfoxide(DMSO) and 20% polyethylene glycol(PEG) 200 showed relatively high values. The synthetic activity of BzAPM as well as initial reaction rate were found to be high in 45% methanol, 45% DMSO and a mixed solvent of 25% DMSO and 20% PEM 200. The imobilized thermolysin was most stable in 25% DMSO and 20% PEG 200 during storage at $40^{\circ}C$ for 42 days. PheOMe in the same solvent system was also found fairly stable against non-enzymatic decomposition at $40^{\circ}C$. Based on the synthetic efficiency and stability, the solvent system containing 25% DMSO and 20% PEG 200 was selected to be appropriate for the enzymatic synthesis of BzAPM.

  • PDF

Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents (확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.127-136
    • /
    • 1994
  • Diffusional sampling devices offer many advantages for measuring concentration levels of industrial contaminants than the conventional pump and charcoal tubes because they are lightweight, require no power, pump or tubing. This study designed to evaluate and compare the sampling performance of passive sampler to charcoal tube from mixed organic solvent workplace with 181 organic solvent using workers working in different concentration of organic solvents. All study workers kept both devices in their breathing zone simultaneuosly in the workplaces, and the sampling analytical results were compared with those of charcoal tube. The results obtained are as follows: 1. The concentrations of toluene and xylene measured by passive sampler were slightly higher than those of charcoal tube, but there were no significant statistical differences between two methods. 2. The concentrations of MEK and cyclo-hexanone measured by passive sampler in low exposure workplace (below 0.20 of MEK TLV levels and 0.1 of cyclo-hexanone TLV levels) were about 2 times higher than that of charcoal tube sampling. While, absorption efficiency of passive sampler was reduced according to increasing concentration measurements of MEK and cyclo-hexanone in air. 3. The ratios of concentrations of toluene, xylene, MEK and cyc1o-hexanone measured by passive sampler over those measured by charcoal tube were 1.11, 1.07, 1.63 and 3.65 respectively. 4. The percentages of concentration of passive samplers within 0.75 and 1.25 of charcoal tube value as a reference value of 1.0 were 57% in toluene, 74% in xylene, 34% in MEK and 32% in cyclo-hexanone respectively. 5. The correlation coefficients of toluene, xylene, MEK and cyclo-hexanone between passive sampler and charcoal tube sampler were 0.963, 0.957, 0.943 and 0.562 with statistical significance.

  • PDF

Metal Surface Coating Using Electrospray of Biodegradable Polymers and $\alpha$-Lipoic Acid Release Behavior for Drug-Eluting Stents (생분해성 고분자의 전기분사를 이용한 약물방출 스텐트용 금속표면 코팅 및 ALA방출 거동)

  • Kim, Dong-Min;Lee, Bong-Soo;Park, Cheol-Ho;Park, Kwi-Deok;Son, Tae-Il;Jeong, Myeong-Ho;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.34 no.2
    • /
    • pp.178-183
    • /
    • 2010
  • Medical metal stents inserted to patients with a cardiovascular disease associated with coronary artery system have relatively increased the survival rate. The development of new stents is, however, urgently required due to restenosis and late thrombosis generated in metal stents. To solve these problems, the biodegradable polymers such as poly(lactide-co-glycolide) (PLGA), poly(L-lactide)(PLLA), and poly ($\varepsilon$-caprolactone)(PCL) were mixed with alpha lipoic acid (ALA), which is well known to inhibit the proliferation of neointimal hyperplasia. Subsequently, the ALA-loaded polymers were coated on stainless steel by electrospray. The drug-eluting behaviors from the coated polymers were investigated according to kinds and concentrations of polymers, spray rates, and kinds of solvents. The drug-eluting rate from PCL with the lowest glass transition temperature was the fastest among three polymers and followed by PLGA and PLLA. The surface roughness increased as the spray rate was increased and also the drug-eluting rate was affected by kinds of solvents with different boiling point. It is expected that drug-eluting stent (DES) coated with ALA-loaded polymers can be applied practically for clinical applications by controlling the behavior of drug release.