• Title/Summary/Keyword: mist-chamber

Search Result 11, Processing Time 0.029 seconds

Numerical Analysis of Effects of Water Mist Injection Characteristics on Cooling Performance in Heated Chamber (미분무수 분사 특성에 따른 가열 챔버 내 냉각 성능 수치 해석)

  • Sumon, S.M.;Lee, S.W.
    • Journal of ILASS-Korea
    • /
    • v.17 no.2
    • /
    • pp.64-70
    • /
    • 2012
  • Water mist fire suppression systems which use relatively small droplets of water with high injection pressure are increasingly being used in wider applications because of its greater efficiency, low flooding damage and low toxicity. However, the performance of the system significantly relies on the water mist characteristics and it requires better understanding of fire suppression mechanism of water mist. In the present study, computational fluid dynamics simulations were carried out to investigate cooling performance of water mist in heated chamber. The gas phase was prepared with natural convection heat transfer model for incompressible ideal case and then the effects of water mist injection characteristics on cooling capabilities were investigated upon the basis of the pre-determined temperature field. For the simulation of water mist behavior, Lagrangian discrete phase model was employed by using a commercial code, FLUENT. Smaller droplet sizes, greater injection angles and higher flow rates provided relatively higher cooling performance.

Clonal Propagation in Commiphora Wightii (Arnott.) Bhandari

  • Mishra, Dhruv Kumar;Kumar, Devendra
    • Journal of Forest and Environmental Science
    • /
    • v.30 no.2
    • /
    • pp.218-225
    • /
    • 2014
  • Studies were carried out to standardize and develop a suitable macro-propagation technology for large scale production of superior clonal stock through stem cuttings in Commiphora wightii Arnott (Bhandari), a data deficient medicinal plant of arid region. For the purpose, three experiments were conducted. The first experiment was tried to elucidate the impact of various cutting diameters (0.50-0.75 cm, 0.75-1.00 cm, 1.00-1.50 cm, and >1.50 cm) in combination with varying growing conditions (sunlight, shade house and mist chamber) on shoot sprouting and rooting without using exogenous plant growth regulators. Cutting diameter (size 0.75-1.00 cm) in mist chamber has shown maximum sprouting (90.00%) and rooting (73.33%), primary root (6.67) and secondary root (16.67) followed by 1.00-1.51 cm in mist chamber. Minimum sprouting (40.00%), rooting (33.33%), number of shoot (1.33), primary root (1.00) and number of secondary root (1.00) was recorded in cutting diameter (size >1.50 cm) in sunlight. Second experiment was performed to find out optimum growth regulator concentration of rooting hormone (100, 200, 500 and 1000 ppm) of Indole-3-acetic acid (IAA) and Indole-3-butyric Acid (IBA) on adventitious root formation on cuttings diameter (size 0.25-0.50 cm) in comparison to control. Maximum rooting percentage (93.33%) was recorded in 200 ppm followed by 500 ppm (86.66%) of IBA as compared to control, which showed only 60 per cent sprouting. Third experiment was performed with newly formed juvenile micro-cuttings treated with varying concentrations of IAA and IBA. The juvenile cuttings (size 6-10 cm, basal dia <0.25 cm) were selected as micro-cuttings. The cuttings treated with IBA (500 ppm) showed 64.30% rooting as compared to other treatments. Results of above experiments indicate that cuttings (size 0.75-1.00 cm dia) may be developed in mist chamber for better performance. While using heavier cuttings, no growth promoting hormones is required however; growth regulator 200 ppm concentration of IBA rooting hormone was observed optimum for promoting macro-propagation in stem cuttings of lower diameter class (0.25-0.50 cm).

Extinguishment of n-heptane Pool Fire by Water Mist Containing Alkali Metal Agent (알칼리 금속염을 함유한 미분무수의 헵탄 Pool Fire 소화)

  • Park, Jae-Man;Shin, Chang-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.105-111
    • /
    • 2005
  • An experimental study is performed for extinguishing of n-heptane pool fire by water mist containing potassium acetate as a fire suppression additive. Water mist was generated by a single pressure nozzle in a small-scale chamber. The drop size distribution of water mist was measured using laser diffraction(Malvern particle sizer). The flame temperature, oxygen concentration and carbon monoxide concentration were measured. In case of using additives, the fire extinguishing time was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.

An Intercomparison of Atmospheric SO$_{2}$ Measurement Techniques (대기중 이산화황 관측 방법들의 실측 비교 연구)

  • 김경렬;이동수;이강웅
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.5
    • /
    • pp.587-591
    • /
    • 1996
  • An intercomparison experiment was implemented to assess the uncertainties and precisions om atmospheric SO$_{2}$ measurement techiques including a pulsed fluorescence (P-F), a diffusion-scrubber /ion chromatography (D-I), and a mist-chamber/ion chromatography (M-I). Each of those three techniques was investigated by researchers at Seoul National University, Yonsei University, and Hankuk University of Foreign Studies, respectively. The concentrations of atmospheric SO$_{2}$ were determined concurrently using three independent measurement techniques at the Seoul National University campus, Korea during Nov.22 to Dec.2, 1995. While the results from the P-F and D-I techinques showed the very close agreements (within +-5%) throughout the experiment period, M-I technique showed systematically smaller values (up to 30%) than the other two techniques. Although sources of larger discrepancy between different techniques were mot identified, the lower SO$_{2}$ values of the M-I method may be related to the errors associated with sample collection effciency, mass flow rate measurements, and standardization of ion chromatography.

  • PDF

Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment (화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발)

  • Kah, Dong-Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

Model Design and Demonstration Test for the Verification of Temperature Reduction Effect of Cooling Fog System with Stainless Steel (스테인리스 쿨링포그의 온도저감효과 검증을 위한 모델설계 및 실증 실험)

  • Kim, Jaekyoung;Kang, Junsuk;Kim, Hoijin
    • Journal of Environmental Science International
    • /
    • v.29 no.6
    • /
    • pp.683-689
    • /
    • 2020
  • According to a NASA Goddard Institute for Space Studies report, temperatures have risen by approximately 1℃ so far, based on temperatures recorded in 1880. The 2003 heatwave in Europe affected approximately 35,000 people across Europe. In this study, a cooling fog, which is used in smart cities, was designed to efficiently reduce the temperature during a heatwave and its pilot test results were interpreted. A model experiment of the cooling fog was conducted using a chamber, in which nano mist spray instruments and spray nozzles were installed. The designed cooling fog chamber model showed a temperature reduction of up to 13.8℃ for artificial pavement and up to 8.0℃ for green surfaces. However, this model was limited by constant wind speed in the experiment. Moreover, if the cooling fog is used when the wind speed is more than 3m/s in the active green zone, the temperature reduction felt by humans is expected to be even greater. As a second study, the effect of cooling fog on temperature reduction was analyzed by installing a pilot test inside the Land Housing Institute (LHI). The data gathered in this research can be useful for the study of heat reduction techniques in urban areas.

Fabrication of Metallic Particle Dispersed Ceramic Based Nanocomposite Powders by the Spray Pyrolysis Process Using Ultrasonic Atomizer and Reduction Process

  • Choa, Y.H.;Kim, B.H.;Jeong, Y.K.;Chae, K.W.;T.Nakayama;T. Kusunose;T.Sekino;K. Niibara
    • Journal of Powder Materials
    • /
    • v.8 no.3
    • /
    • pp.151-156
    • /
    • 2001
  • MgO based nanocomposite powder including ferromagnetic iron particle dispersions, which can be available for the magnetic and catalytic applications, was fabricated by the spray pyrolysis process using ultra-sonic atomizer and reduction processes. Liquid source was prepared from iron (Fe)-nitrate, as a source of Fe nano-dispersion, and magnesium (Mg)-nitrate, as a source of MgO materials, with pure water solvent. After the chamber were heated to given temperatures (500~$^800{\circ}C$), the mist of liquid droplets generated by ultrasonic atomizer carried into the chamber by a carrier gas of air, and the ist was decomposed into Fe-oxide and MgO nano-powder. The obtained powders were reduced by hydrogen atmosphere at 600~$^800{\circ}C$. The reduction behavior was investigated by thermal gravity and hygrometry. After reduction, the aggregated sub-micron Fe/MgO powders were obtained, and each aggregated powder composed of nano-sized Fe/MgO materials. By the difference of the chamber temperature, the particle size of Fe and MgO was changed in a few 10 nm levels. Also, the nano-porous Fe-MgO sub-micron powders were obtained. Through this preparation process and the evaluation of phase and microstructure, it was concluded that the Fe/MgO nanocomposite powders with high surface area and the higher coercive force were successfully fabricated.

  • PDF

Loss of Metalworking Fluids Collected on PVC Filter Due to Contact with Clean Air and Desiccation (PVC필터에 채취된 절삭유의 손실에 관한 연구)

  • Park, Dong-Uk;Ha, Kwon-Chul
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.451-457
    • /
    • 2001
  • Because liquids with high molecular weight such as mineral oil have low vapor pressure at room temperature, it is generally thought to be difficult to lose them to evaporation. However, when they are dispersed into air in small droplets during application in machining processes, their surface area becomes considerably higher. To determine the potential for metalworking fluids (MWF) filter losses, MWF mist was generated and collected on polyvinyl chloride (PVC) filters in test chamber. After collected MWF was exposed to clean air during designated period (range 10~240 minutes) and the filters were desiccated, losses were evaluated. As duration of clean air passing through PVC filter increased, loss of MWF gradually increased. MWF lost after 10 minutes ranged form 12.4 % to 21.8 % of the original loading mass, on average 53.3 % of the total loss. These results indicate that significant mass of MWF collected on PVC filters can be lost at the beginning of air sampling. Loss of MWF collected on PVC filter also occurred during desiccation without active airflow. In multiple regression to identify which factors influence the loss of MWF collected on PVC filter, both duration of air passing through PVC filter and MWF age (fresh vs. used) were significant predictor (p=0.0001). Therefore, workers' exposure to MWF measured method 0500, may underestimate true concentration. Further study is needed to develop a new method to quantify the workers' exposure to airborne MWF mist accurately.

  • PDF

Development Process of Wire Brush Automatic Transplanter of Plait Fixation Method (엮음고정방식의 와이어 브러시 자동 식모기 개발 프로세스)

  • In-Chul Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.577-584
    • /
    • 2023
  • In this study, among the parts of oil vapor collectors that are already being produced, weaving wire brush automatic transplanters for oil vapor collectors for machine tools of the weaving fixing method, which are not automated due to the specificity of the process and are being produced manually, are developed and reliability is secured through performance evaluation. did Oil vapor collectors play an important role in removing air pollutants and improving air quality, and the coagulation effect of the collection technology is mostly due to brushes. In the experiment, an automatic transplanter was developed to automatically manufacture and produce the wire brush of the oil vapor collector, which is manufactured and used manually. For the experiment of the developed wire brush, an experimental chamber was built, and performance and durability were evaluated through the dust collection efficiency evaluation using the electrostatic precipitator method of contaminants (oil mist). Through this study, we intend to reduce the production time and unit cost of collectors and improve the environment at industrial sites.

Method for Rapid Determination and Removal of Nitrogen Oxides in Flue Gas (II). Removal of Nitrogen Oxides Using Ammonia (배기가스중 질소산화물의 신속측정법과 그 제거에 관한 연구 (제 2 보). 암모니아에 의한 $NO_x$의제거)

  • Yong Keun Lee;Kee Jung Paeng;Kyu Ja Hwang
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.2
    • /
    • pp.207-215
    • /
    • 1986
  • A new method was proposed to improve removal of nitrogen oxides $(NO_x)$ in exhaust gas by the reduction method using ammonia. At the relative humidity of 60%, 50 ppm of $NO_x$ was decomposed at the rate of 1% per hour in the reaction chamber. On the other hand, by adding $NH_3$ which was 5 times more concentrated than NOx, the decomposition rate increased to 6% per hour for 50 ppm $NO_x$ and 10% per hour for 20ppm $NO_x$. Within the actual exhausted gases, the decomposition rate of $NO_x$ reached the maximum 15% per hour because of coexisted reducing gases, such as hydrocarbon and carbon monoxide, and excess humidity containing trace metal ions. In the presence of acidic $SO_2$ gas, the decomposition rate of $NO_x$ decreased. The decomposition of $NO_x$ seems to be caused by the mist which is added to the system, and $NH_3$ in the mist which reduces $NO_x$.

  • PDF