• 제목/요약/키워드: minute

검색결과 3,866건 처리시간 0.027초

Cardioplegic Solution의 심근보호 효과에 관한 실험적 연구 (An Experimental Study on the Myocardial Protection Effects of the Cardioplegic Solution)

  • 이종국
    • Journal of Chest Surgery
    • /
    • 제13권4호
    • /
    • pp.321-337
    • /
    • 1980
  • The increasing use of cardioplegic solution for the reduction of ischemic tissue injury requires that all cardiplegic solution be carefully assessed for any protective or damaging properties. This study describes functional, enzymatic and structural assessment of the efficiency of three cardioplegic solutions (Young & GIK, Bretschneider, and $K^{+}$ Albumin solution) in a Modified Isolated Rat Heart Model of cardiopulmonary bypass and ischemic arrest. Isolated rat heart were subjected to a 2-minute period of coronary infusion with a cold cardioplegic or a noncardioplegic solution immediately before and also at the midpoint of a 60-minute period of hypothermic ($10{\pm}1$. C) ischemic cardiac arrest. The results of this study were as follow: 1. Spontaneous heart beat after ischemic arrest occured 16 seconds later after Langendorff reperfusion in the Young & GIK group (n=6), and 40 second later in the Bretschneider group (n=6) and 6 minute later in the $K^{+}$ Albumin group (n=6), and 16 minute later in the control group (non-cardioplegia). A good recovery state of spontaneous heart beat was shown in the Young & GIK and Bretschneider groups. 2. The percentage of recorveries of heart function at 30 minute after postischemic working heart perfusion were : heart rate $91.6{\pm}3.1$% (P<0.01)m oeaj airtuc oressyre $83{\pm}3$% (P<0.01), coronary flow $70{\pm}8$% (P<0.05) and aortic flow flow rate $39{\pm}9.3$% (P<0.05) in the Young & GIK group. This percentage of recoveries of the Young & GIK group was significantly greater than the control group. In the Bretschneider group, the percentage of recoveries were : heart rate $87.8{\pm}7.5$%(P<0.05), peak aortic pressure $71{\pm}2.3$% (P<0.05) and aortic flow rate $33.2{\pm}6.6$%(P<0.05). hte percentage of recoveries were significantly greater than in the control group. In the $K^{+}$ Albumin group, recoveries of heart function were poor. 3. Total CPK leakage was $131.2{\pm}12.75$IU/30 min/gm. dry weight in the control group, $50.65{\pm}12.75$IU in the Young & GIK gruop, $69.40{\pm}32.21$Iu in Bretschneider group, and $103.65{\pm}15.47$IU in the $K^{+}$ Albumin group during the 30 minute postischemic Langendorff reperfusion. Total CPK leakage was significantly less (P<0.001) in the Young & GIK group, than in the control group. 4. Direct correlatin between percentage recovery of aortic flow rate and total amount of CPK leakage from Myocardium was noticed.(Correlation Coefficient r = 0.76, P<0.001). 5. Mild perivascular edema was the only finding of light microscopic study of myocardium after 60 minute ischemic arrest with cold cardioplegic solutions and hypothermla.

  • PDF

짐나르기의 에너지 소요량 (Energy cost of loads carried on the hands, head, or feet)

  • 황대연;남기용
    • The Korean Journal of Physiology
    • /
    • 제5권2호
    • /
    • pp.29-40
    • /
    • 1971
  • Oxygen consumption, pulmonary ventilation, heart rate, and breathing frequency were measured on 8 men walking on a treadmill carrying load of 9 kg on hand, back, or head. Besides measurements were made on subjects carrying loads of 2.6 kg each on both feet. The speed of level walking was 4, 5, and 5.5km/hr and a fixed speed off km/hr with grades of 0, 3, 6, and 9%. Comparisons were made between free walking without load and walking with various types of loads. The following results were obtained. 1. In level or uphill walking the changes in oxygen consumption, pulmonary ventilation, breathing frequency and heart rate were smallest in back load walking, and largest in hand load walking. The method of back load was most efficient and hand load was the least efficient. The energy cost in head load walking was smaller than that of in hand load walking. It was assumed that foot load costed more energy than hand load. 2. In level walking the measured parameters increased abruptly at the speed of 5.5 km/hr. Oxygen consumption in a free walking at 4 km/hr was 11.4ml/kg b.wt., and 13.1 ml/kg b.wt. 5.5 km/hr, and in a hand load walking at 4 km/hr was 13.9, and 18.8 ml/kg b. wt. at 5.5 km/hr. 3. In uphill walking oxygen consumption and other parameters increased abruptly at the grade of 6%. Oxygen consumption at 4 km/hr and 0% grade was 11.4 ml/kg b. wt., 13.6 at 6% grade, and 16.21/kg b. wt. at 9% grade in a free walking. In back load walking oxygen consumption at 4km/hr and 0% grade was 12.3 ml/kg b.wt.,14.9 at 6% grade, and 18.7 ml/kg b.wt. In hand load walking the oxygen consumption was the greatest, namely, 13.9 at 0% grade, 17.9 at 6%, and 20.0 ml/kg b. wt. at 9% grade. 4. Both in level and uphill walking the changes in pulmonary ventilation and heart rate paralleled with oxygen consumption. 5. The changes in heart rate and breathing frequency in hand load were characteristic. Both in level and uphill walk breathing frequency increased to 30 per minute when a load was held on hand and showed a small increase as the exercise became severe. In the other method of load carrying the Peak value of breathing frequency was less than 30 Per minute. Heart rate showed 106 beats/minute even at a speed of 4 km/hr when a load was held on hand, whereas, heart rate was between, 53 and 100 beats/minute in the other types of load carriage. 6. Number of strides per minute in level walking increased as the speed increased. At the speed floater than 5 km/hr number of strides per minute of load carrying walk was greater than that of free walking. In uphill walk number of strides per minute decreased as the grade increased. Number of strides in hand load walk was greatest and back load walk showed the same number of strides as the free walk.

  • PDF

진공의 압력과 시간을 달리할 때 시멘트시험편의 유효공극률 변화 (Effective Porosity Variation of Cement Samples According to Vacuum Pressure and Time)

  • 이상규;이태종;김형찬
    • 지구물리와물리탐사
    • /
    • 제15권4호
    • /
    • pp.163-176
    • /
    • 2012
  • 진공 수포화 과정에서 진공시간과 진공압력을 달리하면서 진공시간 및 압력이 유효공극률 산정에 미치는 영향을 살펴보았다. 시멘트와 모래의 무게비가 1대1인 3개의 시멘트 시험편과 100% 시멘트 모르타르 3개 등 총 6개 시험편을 이용하여 진공 압력을 2, 4, 6, 8, 10 torr, 진공시간을 20, 40, 60, 80, 100분으로 달리하며 측정되는 유효공극률을 비교하였다. 평균 약 25%와 40%로 비교적 큰 유효공극률을 갖는 시멘트 시험편에 대하여 진공압력이 10, 6, 2 torr 일 때 진공시간이 100 ~ 20 분으로 변화하는 3개 시험군 끼리의 결과를 비교하면, 절대편차의 평균값이 0.6%에서부터 0.5%, 0.2%로 작게 나타났다. 진공시간이 100, 60, 20분일 때 진공압력을 각각 2 ~ 10 torr로 변화시키면서 수행한 실험군 끼리의 유효공극률을 비교해도 진공시간이 짧아지면 절대편차의 평균값이 커지는 경향이 있었다. 이로부터 진공압력/진공시간에 관한 국제암반역학회(ISRM) 표준(제안)시험법의 "6 torr 이하/1시간 이상"의 단서로 유추할 수 있었다. 동일한 진공압력에서 진공시간이 20분씩 줄어들 때의 효과와 동일한 진공시간일 때 진공압력이 2 torr씩 낮아질 때의 효과를 정성적으로 밖에 확인할 수 없었는데 그 이유로 습식진공으로 포화된 시험편 내 수분이 $105^{\circ}C$ 오븐 내에서의 건조과정 후에도 완전히 건조되지 않아서 시험편의 초기 함수정도를 동일하게 할 수 없기 때문임을 밝혔다.

점진적 근육이완 훈련을 병용한 EMG바이오 피드백이 긴장성 두통 환자의 EMG 수준 감소에 미치는 효과 (The Effects on EMG Level by EMG Biofeedback with Progressive Muscle Relaxation Training on Tension Headache)

  • 노유자;김남초;김희승
    • 대한간호학회지
    • /
    • 제20권2호
    • /
    • pp.195-213
    • /
    • 1990
  • The purpose of this study is to assess if EMG biofeedback training with progressive muscle relaxation training is effective in reducing the EMG level in patients with tension headaches. This study which lasted from 23 October to 30 December 1989, was conducted on 10 females who were diagnosed as patients with tension headaches and selected from among volunteers at C. University in Seoul. The process of the study was as follows : First, before the treatment the baseline was measured for two weeks and the level of EMG was measured five times in five minutes. And then EMG biofeedback training was used to six weeks, 12 sessions in at and progressive muscle relaxation was done at home by audio tape over eight weeks. Each session was composed of a 5-minute baseline, two 5-minute EMG biofeedback training periods and a 5-minute self-control stage. Each stage was followed by a five minute rest period. So each session took a total of 40 minutes. The EMG level was measured by EMG biofeedback (Autogenic-Cyborg : M 130 EMG module). The results were as follows : 1. The average age of the subjects was 44.1 years and the average history of headache was 10.6 years(range 6 months-20 yens). 2. The level of EMG was lowest between the third and the fourth week of the training except in Cases I and IV. 3. The patients began to show a nonconciliatory attitude at the first session of the fifth week of the training.

  • PDF

Methylprednisolone을 첨가한 GIK용액의 심근보호효과에 관한 실험적 연구 (An experimental study on the myocardial protection effect of the methylprednisolone mixed GIK solution)

  • 유시원
    • Journal of Chest Surgery
    • /
    • 제17권4호
    • /
    • pp.574-586
    • /
    • 1984
  • Although corticosteroid have been shown to stabilize lysosomal membranes and prevent release of hydrolytic enzymes, the mechanism of membrane stabilization remains obscure. This study described functional assessment of efficiency of methylprednisolone in GIK solution by using a isolated Rat Heart Model. Isolated rat heart were subjected to a 2-minute period of coronary infusion with a cold GIK or methylprednisolone mixed cold GIK solution immediately before and also at the midpoint of a 60-minute period of hypothermic [$10{\pm}1^{\circ}C$] ischemic arrest. The result of this were as follow: 1.Spontaneous heart beat after ischemic arrest occurred 11 second later after Langendorffs reperfusion in the methylprednisolone mixed GIK group and 14 second later in the control group. 2.The percentage of recoveries of heart rate at 30 minute after postischemic working heart perfusion was 88.6\ulcorner.6% in the methylprednisolone mixed GIK group. This percentage of recovery was not significantly greater than the control group. 3.The percentage of heart function at 30 minute after postischemic working heart perfusion were; peak aortic pressure $90.8{\pm}4.5%$ coronary flow $87.5{\pm}1.45$ and aortic flow $74.9{\pm}11.8%$ in the methylprednisolone mixed GIK group. This percentage of recovery was significantly greater than the control group. [p<0.05]

  • PDF

의치상용 열중합 레진의 Curing방법에 따른 파절 강도의 비교실험연구 (Research for The Comparing Test of the Fracture Strength According to the Heat Curing Method in the Denture Base Resin)

  • 한민수
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.95-103
    • /
    • 2002
  • For this study, self curing resin and heat curing resin used for existing usual resin denture base in the denture industry were chosen by manufacturer. Curing tests for 30-minute, I-hour, 2-hour and 3-hour were conducted to know the strength of the resins and conduct analysis to get other necessary information. The results obtained are as follows: 1. Heat curing resins show a little differences among the manufacturers. However 30-minute curing resin shows great difference as shown in the fracture strength test. 2. The effect from the granularity of the resins on the fracture strength was found insignificant which means there is no difference between coherence and strength. 3. To summarize the results from each time level, the longer the time is, the more the minute cracks on the surface, which is the cause of reduced strength. From this test, it was identified that in making the denture base for patients in dental clinics, 30-minute curing is most efficient and effective in reducing discoloration and monomers, although long-time curing has been considered to be the principal.

  • PDF

자동 시각 검사 시스템 -현수애자의 미세균열 검출- (Automatic Visual Inspection System -Detection of Insulator′s Minute Crack-)

  • 이상용;김용철
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2004년도 춘계학술대회 학술발표 논문집 제14권 제1호
    • /
    • pp.576-579
    • /
    • 2004
  • 자동화 설비 도입으로 생산성이 향상되었지만, 양품뿐만 아니라 불량품 또한 대량 생산할 가능성이 있어서 전수검사가 필수적이 되고 있다. 검사자가 많은 양의 제품을 전수검사 한다는 것은 무리가 따르기 때문에 자동 검사 시스템에 대한 연구가 다양하게 진행되어 왔다. 본 연구에서는 컴퓨터 비전을 이용한 자동 시각 검사 시스템으로서 현수애자의 미세균열 자동 검출 시스템을 개발하였다. 현수애자의 미세균열 자동 검사 시스템: 현수애자의 미세균열을 검출하기 위해, 현수애자를 턴 텐이블 위에서 회전시키고, 프로그래시브 스캔 카메라로 애자의 영상을 획득하고, 이 영상을 전처리 하여 그림자, 노이즈 등을 제거하고, 특징을 이용하여 미세균열을 검출한다.

  • PDF

과업에 따른 학령전기($5{\sim}7$세) 아동의 구어속도에 관한 연구 (A Study on the Speech Rates of 5- to 7-Year-old Children Depending upon their Tasks)

  • 신명선;안종복
    • 말소리와 음성과학
    • /
    • 제1권3호
    • /
    • pp.163-168
    • /
    • 2009
  • This study investigated the determination of speech rates, words per minute (WPM) and syllables per minute (SPM), of $5{\sim}7$ year-old normal children to understand if there are any differences in the rates according to the children's age and sex. All participants were required to conduct story retelling tasks (SRT) and picture description tasks (PDT). In SRT, there was a significant difference between the groups of 5 year-old and 7 year-old children on WPM. However, there was no significant difference between the groups of ages regarding SPM. In addition, there was no significant difference between the groups according to sex on WPM and SPM. In PDT, there was no significant difference between the groups according to their ages and sex on WPM and SPM. The current research found that the speech rates of the preschool children might be somewhat different in their utterance abilities according to their age, but there was no obvious difference according to their sex. The findings can advance development of a clinical tool to screen children with fluency disorders and to determine the steps in establishing speech rates of children in the language development period.

  • PDF

서로다른 APF 제재의 적용시간에 따른 법랑질내 불소 흡수량 및 우식 억제효과에 관한 비교 연구 (ASSESSMENT OF THE INFLUENCE OF APPLICATION TIME OF DIFFERENT APF AGENTS ON THE ENAMEL FLUORIDE UPTAKE AND ANTICARIOGENICITY)

  • 권순원;김용기
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.306-326
    • /
    • 1996
  • The purpose of this study was to compare the enamel fluoride uptake and anticariogenic effect following topical application with different physical form of fluoride and application time. The results can be summarized as follows: 1. While the 4-minute applicaton increased the enamel fluoride uptake significantly than 1-minute application regardless of physical form of applied topical fluoride agents, no siginificant difference could be found between foam and gel type when applied for the identical period of time. 2. The application time or the physical form of topical agents had no singificant influence on the reduction of caries lesion. 3. Based upon the above-mentioned results of this study, it cannot be concluded that the amount of enamel fluoride uptake has an absolute impact on the change of lesion depth. Therefore, the clinical application of 1-minute topical fluoride application which appears to have a similar anticariogenic efficacy to 4-minute fluoride application may be encouraged.

  • PDF

廢 페인트 活性炭의 吸着特性 (Adsorption Characteristics of Waste-Paint Activated Carbon)

  • 박정호;박승조
    • 자원리싸이클링
    • /
    • 제9권6호
    • /
    • pp.9-14
    • /
    • 2000
  • CSAC와 WPAC의 흡착특성을 보면 H공장 2차 처리수와 D공장 배출수에 함유된 ABS흡착에서 얻어진 Freundlich흡착등온식은 WPAC인 경우 q=23.12 $C^{ 0.42}$, q=18.32 $C^{0.38}$ 이고 CSAC인 경우 각각 $q=36.76C^{1.37}$ , q=26.67 $C^{0.42}$ 이었다. H공장 방류수의 파과점은 CSAC인 경우 680분이었고 WPAC는 610분이었다. 한편 D공장 배출수의 파과점은 CSAC인 경우 720분이었고 WPAC은 640분이었다. 이상의 결과로부터 CSAC 대체물로서 WPAC이 가능성이 있을 것으로 생각된다.

  • PDF