• 제목/요약/키워드: miniscrew

검색결과 101건 처리시간 0.022초

Influence of changing various parameters in miniscrew-assisted rapid palatal expansion: A three-dimensional finite element analysis

  • Yoon, Soungjun;Lee, Dong-Yul;Jung, Seok-Ki
    • 대한치과교정학회지
    • /
    • 제49권3호
    • /
    • pp.150-160
    • /
    • 2019
  • Objective: This study aimed to analyze the effect of changing various parameters of the bone-borne rapid palatal expander (RPE) using the finite element method (FEM). Methods: In eight experimental groups, we investigated the effect of the number, position, and length of miniscrews; positional changes of the expander; and changes in the hook length on maxillary expansion. In finite element analysis, we compared the magnitude and distribution of stress, and the displacement changes following expansion of the bone-borne RPE. Results: When we compared the number and position of miniscrews, placing miniscrews in the anterior and posterior sides was advantageous for maxillary expansion in terms of stress distribution and displacement changes. Miniscrew length did not significantly affect stress distribution and displacement changes. Furthermore, anteroposterior displacement of the expander did not significantly affect transverse maxillary expansion but had various effects on vertical changes of the maxilla. The maxilla rotated clockwise when the miniscrews were placed in the anterior region. The hook length of the expander did not show consistent results in terms of changes in stress distribution and magnitude or in displacement changes. Conclusions: The findings of this study suggest that changes in the location and length of the miniscrews and displacement of the bone-borne RPE could affect the pattern of the maxillary expansion, depending on the combination of these factors.

정중구개봉합부의 해부학적 구조에 관한 전산화 단층촬영을 이용한 연구 (Anatomical characteristics of the midpalatal suture area for miniscrew implantation using CT image)

  • 박영철;이종석;김두형
    • 대한치과교정학회지
    • /
    • 제35권1호
    • /
    • pp.35-42
    • /
    • 2005
  • 교정용 임플란트 사용에 있어서 정중구개봉합부위의 골조직의 높이에 대한 구체적인 해부학적 자료가 없어서 임상에 적용시 이론적 근거가 부족한 것이 사실이었다. 이에 본 연구는 전산화단층촬영과 재구성 프로그램인 V works 40 (Cybermed Inc. Seoul. Korea)을 이용하여 임플란트 식립을 위한 해부학적 근거를 얻고자 하였다. 성인 남자 14명, 성인 여자 14명의 보철용 임플란트를 위한 CT 자료를 통해 정중 시상면에서 상악골의 길이를 계측하고 정중구개봉합 부위에서 골조직 두께를 측정하며 교정용 임플란트를 안전하게 식립할 수 있는 구체적 부위를 설정하고자 하여 다음과 같은 결과를 얻었다. ANS에서 PNS까지의 상악골의 길이를 계측한 결과 남자에서는 평균 51.08mm, 여자에서는 평균 47.34mm였다 남녀 사이에는 통계적으로 유의한 차이가 있었다 (p<005). 정중구개봉합부위의 골조직 두께를 측정한 결과 남자의 ANS-PNS길이의 중점에서 구개평면을 따라 PNS쪽으로 15 mm지점을 제외하고는 남녀 모두에서 5mm이상의 골조직이 존재하였다. 정중구개봉합부위에 교정용 임플란트를 적응할 때 안정적인 식립부위는 구개평면을 따라서 ANS로부터 남자는 19.43mm 후방부위, 여자는 17.62mm 후방부위에 해당하였다. 이상의 결과로 정중구개봉합부위의 안정적인 식립부위에서는 교정용 임플란트 식립이 적합하다고 판단되며 이를 바탕으로 정중구개봉합부위의 교정용 임플란트를 활용하여 교정치료 영역을 넓힐 수 있을 것이다.

악정형력 적용을 위한 골내 고정원으로서 미니플레이트 형상의 영향: 3차원 유한요소법적 연구 (INFLUENCE OF MINIPLATE SHAPES AS SKELETAL ANCHORAGE FOR APPLICATION OF ORTHOPEDIC FORCE: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS)

  • 이남기;백승학;최동순;박영욱;김지혁;차봉근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권4호
    • /
    • pp.345-352
    • /
    • 2008
  • Purpose: This study was performed to evaluate the stress distribution in the bone and the displacement distribution of the miniscrew under orthopedic force with two different types of miniplate design as skeletal anchorage for orthopedic treatment. Materials and methods: Finite element models were made for 6-hole miniplate (0.8mm in thickness), which were designed in two different shapes-one is curvilinear shaped (C plate, Jeil Medical Co., Korea) and another, Y shaped (Y plate), fixed with 3 pieces of miniscrew 2mm-diameter and 6mm-long respectively. A traction force of 4 N was applied in $0^{\circ}$, $30^{\circ}$ and $60^{\circ}$ to imaginary axis connecting two unfixed distalmost holes of the miniplate. Results: The maximum von Mises stress in the bone was much greater in the cortical portion rather than in the cancellous portion. C plate showed greater maximum von Mises stress in the cortical bone than Y plate. The maximum displacement of the miniscrew was greater in C plate than Y plate. The more increased the angle of the applied orthopedic force, the greater maximum von Mises stress in the bone and maximum displacement of the miniscrew. It was observed that in C plate, the von Mises stress in the bone and displacement of the miniscrew were distributed around the distalmost screw-fixed area. Conclusions: The results suggest that Y plate should have the advantage over C plate and in the placement of the miniplate, its imaginary axis should be placed as parallel as possible to the direction of orthopedic force to obtain its primary stability.

미니플레이트의 골내 고정원 적용 시 초기 안정성에 영향을 주는 요인에 대한 3차원 유한요소법적 연구 (Factors influencing primary stability of miniplate anchorage: a three-dimensional finite element analysis)

  • 이남기;최동순;장인산;차봉근
    • 대한치과교정학회지
    • /
    • 제38권5호
    • /
    • pp.304-313
    • /
    • 2008
  • 본 연구는 골내 고정원으로 사용하는 미니플레이트 시스템의 초기 안정성에 영향을 주는 요인에 대해 알아보기 위해 시행하였다. 미니플레이트의 고정에 사용되는 미니스크류의 길이, 수 및 적용되는 교정력의 방향에 따른 골내 응력 분포 양상과 미니스크류의 변위 정도를 분석하기 위하여 3차원 유한요소분석을 시행하였다. 단순화한 골 모델에 6 hole의 곡선형 미니플레이트를 위치하고 직경 2 mm의 미니스크류로 고정하되 각각 6 mm와 4 mm 길이의 두 가지 종류로 세 개 또는 두 개로 고정한 총 네 개의 유한요소모델을 제작한 후 각각의 모델에서 4 N의 교정력을 미니플레이트의 고정되지 않은(unfixed) 가장 원심측 두개의 hole을 연결한 가상의 축에 대해 $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$ 방향으로 각각 적용하였다. 미니플레이트를 고정하는 미니스크류가 동일 길이일 경우 개수가 작을수록, 동일 개수일 경우 길이가 짧을수록 골에 나타나는 최대 응력과 미니스크류의 최대 변위가 증가되었다. 골에 나타나는 최대 응력은 해면골에 비해 피질골에 집중되어 응력의 대부분은 피질골에서 흡수되었다. 미니플레이트의 가상의 축에 대해 교정력의 견인 방향이 증가할수록 골내의 최대 응력과 미니스크류의 최대 변위가 증가되었다. 골내의 최대 응력과 미니스크류의 최대 변위는 적용된 견인력 지점에서 가장 가까운 미니스크류 고정 부위였다. 이상의 결과로 미니플레이트 시스템의 초기 안정성을 위해 2 mm 직경의 미니스크류를 사용 시 4 mm 보다는 6 mm 길이의 미니스크류를, 2개보다는 3개 식립하는 것이 더 유리하며, 미니플레이트의 가상의 축에 대해 적용하는 교정력의 견인방향이 가급적 일치되도록 미니플레이트를 위치시키는 것이 좋을 것으로 생각된다.