• Title/Summary/Keyword: minimal operation

Search Result 337, Processing Time 0.026 seconds

Cognition and Memory Impairment after Operation in Ruptured Cerebral Aneurysm Patients (뇌동맥류 파열 환자의 수술후 인지기능과 기억력장애에 관한 연구)

  • Kim, Byung Joo;Choi, Chang Hwa;Kim, Dae Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.7
    • /
    • pp.842-848
    • /
    • 2001
  • Objectives : The mortality rate of subarachnoid hemorrhage(SAH) has been reduced recently due to refinement of microsurgical technique and improved perioperative management. Also, many survivors of SAH show excellent neurological recoveries. However, we found that a high proportion of the survivors do not fully regain their premorbid status in cognitive and memory function. Object of this study is to evaluate which factors might influence on cognitive and memory impairment in ruptured aneurysmal SAH patients. Methods : In this prospective study, a series of 66 patients with aneurysmal subarachnoid hemorrhage(SAH) from 1996 to 1998, most of whom had a "good" or "fair" neurological outcome, were assessed with various tests of cognition and memory function. All patients underwent clipping operation by pterional approach. Right side approach was performed in 16 case and left 21 cases. K-WAIS(Korean-Wechsler Adult Intelligence Scale) was used as method of cognition and memory function test. The time interval between SAH and assessment varied between 4 months and 8 months, averaging 6.2 months. Statistical analyses were carried out for each test score to see whether aneurysm site(A-com : non A-com), route of approach, age and sex, vasospasm, Hunt-Hess grade and Fisher CT group at admission, Glasgow Outcome Scale(GOS) at discharge affect cognitive and memory function. Results : Aneurysm site was not shown to be associated with performance on any test, and the initial grade (Hunt-Hess grade, Fisher CT group) of SAH and vasospasm had only minimal predictive values. The grade at discharge( GOS) was proved to be the best predictor of impairment of cognition and memory function within 1 year after operation. Conclusion : The authors conclude that the diffuse effects of SAH are more important than focal neuropathology in relation to cognitive impairment in this group of patients.

  • PDF

Clinical Features of Distal Tibial Fractures and Treatment Results of Minimally Invasive Plate Osteosynthesis (원위 경골 골절의 임상양상 및 최소 침습적 금속판 고정술의 결과)

  • Kim, Weon-Yoo;Ji, Jong-Hun;Kwon, Oh-Soo;Park, Sang-Eun;Kim, Young-Yul;Kil, Ho-Jin;Jeong, Jae-Jung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.2
    • /
    • pp.94-100
    • /
    • 2012
  • Purpose: The purpose of this study is to analyze the clinical features of distal tibia fractures and to evaluate the treatment outcomes of minimally invasive plate osteosynthesis (MIPO). Materials and Methods: From January 2004 to December 2009, 84 cases of 81 patients treated with plate fixation for distal tibia fracture were enrolled in this retrospective review. We investigated age, sex, injury mechanism, fracture patterns, and complications, and the clinical features were analyzed. To evaluate the treatment outcomes of MIPO, we divided into two groups. MIPO group consisted of 55 patients were treated with MIPO technique and conventional group consisted of 18 patients were treated with open reduction and internal fixation with conventional anterolateral plating. The results were compared between two groups by assessing bony union time, operation time, amount of blood loss, range of ankle motion, clinical score by American Orthopaedic Foot and Ankle Society (AOFAS) score, and post-operative complications. Results: The mean age of 81 patients with distal tibia fracture was 54.8 years. According to AO classification, A1:2:3 were 16, 20, 16 patients, B1:2:3 were 2, 8, 7, C1:2:3 were 1, 3, 11 patients. According to injury mechanism, slip down injury was patients, traffic accident was 26, fall from height injury was 14 patients respectively. The type A fractures were lower energy trauma and more older patients. The type C fractures were higher energy trauma and younger patients. MIPO group was better than conventional group in operative time, blood loss, bony union time, and ankle joint motion. In complications, MIPO group showed no nonunion and infection, one malunion, one skin necrosis, nine skin irritations, and one screw breakage. Conventional group showed two nonunion, four infections, two skin necrosis, and one metal failure. Conclusion: Distal tibial fractures caused by low energy trauma were on the increase. Minimal invasive plate osteosynthesis was shorter bony union time and operation time, less blood loss, and larger ankle motions than conventional open reduction and plate fixation.

Studies on the Hemodilution Perfusion with Rygg-Kyvsgaard Oxygenator (혈액희석 체외순환법에 관한 임상적 관찰 -상온하 Rygg-Kyvsgaard 산화기 및 Sigmamotor pump 사용예를 중심으로-)

  • 손광현
    • Journal of Chest Surgery
    • /
    • v.3 no.2
    • /
    • pp.73-90
    • /
    • 1970
  • Clinical perfusion data on 16 cases of cardiopulmonary bypass using Sigmamotor pump and RyggKyvsgaard Oxygenator which performed at Seoul National University Hospital during the period of Aug. 1968 to Aug. 1970 was analized. AIl cases were hemodiluted and the perfusion was carried out under the normothermic condition. The age of the patients ranged between 6 and 43 years. The b:dy weight varied between 18.3 and 54.0 kg and the body surface area between 0.78 and 1. 59$M^2$. The priming solution was consiste:I with fresh ACD blood. Hartmann solution and Mannitol. The average amount of priming was approximately 2242 ml. The average hemodilution rate was 17%. The flow rate ranged from 1.7L to 3.5L/Min/$M^2$ and averaged 2.4L/Min/$M^2$ or 78mI/Min/kg. The duration of perfusion varied from 22 to 110 min with average of 56.9 minutes. Some hemodynamic responses were observed. The arterial pressure dropped immediately after the initiation of partial perfusion and was more marked after the total perfusion foIlowed by gradual increase to the safety level. The central venous pressure reflected the reduced blood volume especially in the cases of prolonged perfusion which lasted over 60 min. In most of the cases, red blood cell count decreased and white blood ceIl count increased after the perfusion. Hemoglobin level was decreased, averaging of 12.5mg%, Hct 3.3% and platelets count of 18% postoperatively. Plasma hemoglobin increased mildly, from pre-perfusion average value of 4. 06mg% to postperfusion value of 22.5mg%. Serum potassium was 4.4mEq/L pre-operatively and was decreased to 3.7mEq/L postoperatively. Five cases showed definite hypopotassemia immediately after the operation. Sodium and chloride decreased mildly. These electrolyte changes are thought to be related with hemodilution. diuretics and reduced blood volume during and after the perfusion. Arterial blood pH value revealed minimal to moderate elevation from preperfusion average value of 7.376 to 7.461 during perfusion and then 7.365 after perfusion. The pC02 and hicarbonate showed minimal to moderately lowered values. The total CO2 was decreased. Buffer base decreased during perfusion (Av. 42.6mEq/L) and further decreased after the perfusion (Av. 40.8mEq/L). These arterial blood acid base changes suggested that the metabolic acidosis was accompanied by respiratory alkalosis during and immediately after the perfusion. Authors belived that the acidosis could more effectively be corrected with the more additional dose of bicarbonate than we used by this study. The chest tune drainage during the first 24 hours following operation was 1158 ml in average. One case (Case No. 15) showd definite bleeding tendency and it was believed that the cause might be due to the defect of heparin and protamine titration. The average urinary out put during 24 hours post-perfusion was 1291ml. One case (Case No. ]) showed definite post perfusion oliguria. As conclusion hemodilution using fresh ACD blood. Hartmann and Mannitol solution added with Bivon and high flow rate unler normothermia. was thought to amelioratc the severity of mctabolic acidosis during and after perfusion with relatively satisfactory effect on the diuresis and bleeding tendency.

  • PDF

Tenodesis of Long Head of the Biceps Brachii Tendon with Bioabsorbable Interference Screw (체내 흡수성 간섭 나사를 이용한 상완 이두건 장두건 고정술의 임상적 결과)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Lee, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.78-83
    • /
    • 2007
  • Purpose: This study reports the clinical results of the tenodesis of long head of the Biceps brachii tendon with bioabsorbable interference screw by minimal open procedure. Materials and Methods: Ten cases of 10 patients (7 male, 3 female) were included in this study. The average age was 45.8 years old and the average period from the symptom onset to operation was 13.7 months. Average preoperative ASES score was 38.5. The causes of injury was; sports activities in 4 patients, unknown in 4 patients, industrial accident in 1 patient and traffic accident in 1 patient. The average follow up period was 12.1 months. Tenodesis with bioabsorbable interference screw by minimal open precedure was performed in all cases. Results: The ASES score improved to 87.5 at last follow up period and 6 cases had full range of motion of the shoulder. 4 cases had mild limited range of motion of the shoulder without any problem in normal daily activity. Conclusion: It was assumed that tenodesis of long head of the biceps brachii tendon with bioabsorbable interference screw by minimal open precedure was one of the good methods with good clinical results.

SIMD MAC Unit Design for Multimedia Data Processing (멀티미디어 데이터 처리에 적합한 SIMD MAC 연산기의 설계)

  • Hong, In-Pyo;Jeong, Woo-Kyong;Jeong Jae-Won;Lee Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.12
    • /
    • pp.44-55
    • /
    • 2001
  • MAC(Multiply and ACcumulate) is the core operation of multimedia data processing. Because MAC units implemented on traditional DSP units or embedded processors have latency of three cycles and cannot operate on multiple data simultaneously, then, performances are seriously limited. Many high end general purpose microprocessors have SIMD MAC unit as a functional unit. But these high end MAC units must support pipeline structure for various operation modes and high clock frequency, which makes control logic complex and increases chip area. In this paper, a 64bit SIMD MAC unit for embedded processors is designed. It is implemented to have a latency of one clock cycle to remove pipeline control logics and a minimal area overhead for SIMD support is added to existing Booth multipliers.

  • PDF

Prevention for Collapse Using Aqua Splint® in Zygoma Arch Fractures (관골궁 골절 환자에서 함몰 방지를 위한 Aqua splint®를 이용한 보호대)

  • Seo, Woo Jin;Kim, Chang Yeon;Hwang, Weon Jung;Kim, Jeong Tae
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.813-817
    • /
    • 2007
  • Purpose: The zygomatic arch is a key element which composes the facial contour. In many cases of zygomatic arch fracture, it is difficult to fix rigidly the fractured segments. If reduced bone segments were not fixed rigidly, they are proven to be displaced by mastication or unintentional external forces. So, unfixed zygomatic arch fracture after reduction may require a external device of prevention of collapse. We introduce a new protector which stabilizing the fractured segments to prevent for collapse of the reduced zygomatic arch fracture. Methods: After reduction of zygomatic arch with blind approach(Gillies', Dingman or Keen's approach), bone segments was pulled with percutaneous traction suture in medial aspect of zygomatic arch. Then, the suture was fixed with Aqua $splint^{(R)}$, externally. And intraoperative and postoperative X-ray was done. The splint was removed on 14 days after the operation. Results: 5 patients were treated with this method. 4 patients of total patients had no collapse in zygomatic arch. There was minimal collapse in one patient. Postoperative complications such as facial nerve injury, mouth opening difficulty, contour deformity, infection, scar were not observed. Conclusion: In comparison with other techniques, this technique has several advantages which are simple and easy method, short operation time, no scar, less soft tissue injury, and facilitated removal of splint. Therefore, Aqua $splint^{(R)}$ would be a good alternative to prevent for collapse in unstable zygomatic arch fractures

Efficient Attribute Based Digital Signature that Minimizes Operations on Secure Hardware (보안 하드웨어 연산 최소화를 통한 효율적인 속성 기반 전자서명 구현)

  • Yoon, Jungjoon;Lee, Jeonghyuk;Kim, Jihye;Oh, Hyunok
    • Journal of KIISE
    • /
    • v.44 no.4
    • /
    • pp.344-351
    • /
    • 2017
  • An attribute based signature system is a cryptographic system where users produce signatures based on some predicate of attributes, using keys issued by one or more attribute authorities. If a private key is leaked during signature generation, the signature can be forged. Therefore, signing operation computations should be performed using secure hardware, which is called tamper resistant hardware in this paper. However, since tamper resistant hardware does not provide high performance, it cannot perform many operations requiring attribute based signatures in a short time frame. This paper proposes a new attribute based signature system using high performance general hardware and low performance tamper resistant hardware. The proposed signature scheme consists of two signature schemes within a existing attribute based signature scheme and a digital signature scheme. In the proposed scheme, although the attribute based signature is performed in insecure environments, the digital signature scheme using tamper resistant hardware guarantees the security of the signature scheme. The proposed scheme improves the performance by 11 times compared to the traditional attribute based signature scheme on a system using only tamper resistant hardware.

The Classification of Aging Lower Eyelid and Selection of the Operation Options in Asians (동양인에서의 노인성 하안검의 유형별 분류 및 수술법의 선택)

  • Kwon, Soon Geun;Park, Jun;Yang, Won Yong;You, Young Cheun;Kang, Sang Yun
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.581-588
    • /
    • 2008
  • Purpose: It is generally accepted that anatomical structures of the soft tissue in Asian faces are quite different from those in Caucasian. It is presumed that these differences are due to collagen rich thick dermis and durable superficial musculo-apponeurotic system (SMAS) in Asian. We classified the aging lower eyelids and reviewed the operative procedures according to the types of aging lower eyelids in Asian. Methods: We compared preoperative and postoperative photos of 117 patients over 30 years of age, who underwent lower blepharoplasty at the Kyunghee Medical Center from January 2001 to April 2006. We classified the patients based on the degree of skin laxity, presence of nasojugal groove and malar bag, the extent of aging process. We also reviewed the operative procedures according to each type of classification. Results: We classified our patients into four types as following. Type I patients showed minimal skin-muscle excess confined to lower eyelids regardless of the facial line. For these patients, we performed only transcutaneous or transconjunctival blepharoplasty. In type II patients, nasojugal grooves were shown and skin- muscle laxity was limited to the medial side of imaginary vertical line at lateral margin of pupil. In these cases, we performed free fat graft or fat repositioning on nasojugal groove or fat removal and septal duplication confined to medial side. Type III patients displayed more advanced medial bulging and remarkable laxity over the lateral side, the same operation methods as those of type II were applied at the lateral side of the line. Type IV patients demonstrated extensive midfacial aging changes including malar bags and underwent superficial subciliary cheek lift. Conclusion: The lower eyelid aging of Asian is different from those of Caucasian. We think that our classification is useful in selection of appropriate operative procedure to address specific problems for Asian patients.

Arthroscopic Treatment of Fractures of the Intercondylar Eminence of the Tibia Using Pull-Out Wire (견인강선을 이용한 경골극 견열 골절의 관절경적 치료)

  • Kim, Hyun Kon;Kim, Sung Jae;Hahn, Myung Hoon;Kang, Yong Ho;Jung, Hwan Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 1998
  • Recently, a variety of arthroscopic techniques have been reported for the treatment of the displaced tibial eminence fracture. The purpose of this study was to describe details of arthroscopic technique using pull-out wire and to evaluate the results. Eleven patients with irreducible type II and type III tibial eminence fractures underwent the arthroscopic reduction and internal fixation using double strand pull-out wiring. The anterior cruciate ligament tibial drill guide was utilized for the reduction of fracture and passage of the guide pins. The tibial eminence fracture was firmly fixed with double strand 26-gauge pull-out wire(0.45mm diameter). Fracture union was achieved at 7.2 weeks (range, six to eight weeks) after operation. All cases were united at the last follow-up. Subjectively, nine patients had no pain and no restriction of daily activities. Two patients with combined injuries had limitation of knee motion(10 to 130 degrees, respectively) and one patient showed mild anterior laxity. Early rehabilitation was enabled without loss of reduction and breakage of pull-out wire. The arthroscopic reduction and internal fixation using pull-out wire showed good results including early rehabilitation, early fracture union, minimal morbidity, and no requirement of the second operation for hard ware removal.

  • PDF

Plasma Concentrations of Morphine during Postoperative Pain Control

  • Park, Hahck-Soo;Kim, Jong-Hak;Kim, Yi-Jeong;Kim, Dong-Yeon
    • The Korean Journal of Pain
    • /
    • v.24 no.3
    • /
    • pp.146-153
    • /
    • 2011
  • Background: Morphine has been commonly used for postoperative pain control. We measured plasma concentrations of morphine and compared the efficacy and safety of continuous epidural analgesia (CEA) using morphinebupivacaine with intravenous patient controlled analgesia (IV-PCA) with morphine for 48 hrs after the end of the operation. Methods: Nineteen patients undergoing Mile's operation were assigned to receive a morphine loading dose of 5 mg followed by IV-PCA with 0.1% morphine (IV-PCA group, n = 9) or a morphine loading dose of 2 mg and 0.125% bupivacaine 10 ml, followed by CEA with 0.004% morphine and 0.075% bupivacaine at a rate of 5 ml/hr (CEA group, n = 10). The plasma concentrations of morphine were measured and visual analog scales (VAS) for pain were recorded at 1, 6, 12, 24, and 48 hr postoperatively and the effects on respiration and any other side effects were noted. Results: The mean maximal and minimal levels of plasma morphine were $40.2{\pm}21.2\;ng/ml$ and $23.4{\pm}9.7\;ng/ml$ for the IV-PCA group and $11.8{\pm}3.5\;ng/ml$ and $8.2{\pm}1.9\;ng/ml$ for the CEA group, respectively. Resting and dynamic pain scores were significantly lower in the CEA group than in the IV-PCA group. There were no significant differences for the effects on respiration and for any side effects between the two groups. Conclusions: We evaluated plasma concentrations of morphine with CEA using morphine-bupivacaine and IV-PCA using morphine for the postoperative pain control. The CEA group had better postoperative analgesia than that of the IV-PCA group and the incidence of side effects were not significantly different between the two groups.