• 제목/요약/키워드: minimal element

검색결과 152건 처리시간 0.018초

Participation of SRE4, an URE1 Enhancer Core Sequence, in the Sterol-Mediated Transcriptional Upregulation of the Human Apolipoprotein E Gene

  • Min, Jung-Hwa;Paik, Young-Ki
    • BMB Reports
    • /
    • 제31권6호
    • /
    • pp.565-571
    • /
    • 1998
  • The expression of the endogenous human apolipoprotein(apo)E gene was significantly induced when HepG2 cells were treated with exogenous 25-hydroxy-cholesterol. This sterol-mediated apoE gene upregulation appears to require the participation of a positive element for the apoE gene transcription (PET) ( -169/ -140), a core sequence of upstream regulatory element (URE)1 enhancer of the human apoE gene. This PET was renamed as sterol regulatory element (SRE)4 based on its new role as a sensor for the level of intracellular sterol. Furthermore, a gel mobility shift analysis showed that binding activity of the SRE4 binding protein (BP) obtained from HepG2 cells was induced by sterol treatment, while that from either MCF7 or BT20 cells remained unchanged. Binding activity of SRE4BP was also induced in mouse macrophage cells, J774A.1, by sterol treatment, but it was drastically reduced when cells were subjected to treatment of AY-9944, a potent inhibitor for sterol synthesis. However, binding activity of Spl, which is a co-binding protein to the SRE4 region, remained the same in either condition, suggesting that SRE4BP (formally known as PETBP) may be mainly responsible for the sterol-mediated regulation of the apoE gene expression. Deletion analysis of the core binding site of SRE4BP by gel mobility shift assays showed that the minimal sequence of the SRE4BP binding appears to reside between -157 and -140, confirming the identity of SRE4 with the previously determined core sequence of URE1.

  • PDF

AC Cycles 가변을 이용한 PTC 발열체의 전력제어 (Power control of PTC heating element using variable AC Cycles)

  • 공재웅;이영주;김두영
    • 융합신호처리학회논문지
    • /
    • 제12권4호
    • /
    • pp.355-361
    • /
    • 2011
  • 기존 발열체의 전력제어는 On-Off 제어, 위상제어, PWM 제어를 사용해왔다. 최근 개발된 PTC 발열체를 기존의 방법으로 전력제어를 하였을 경우, 온도를 정밀하게 제어하지 못하고 인체에 유해한 전자파가 발생한다. 본 논문은 AC Cycles 가변을 이용한 PTC 열선의 전력 제어를 제안한다. 이것은 N개의 교류 cycle을 전력 제어의 단위로 간주하여, 각 cycle 마다 On-Off 여부를 결정하여 N cycles 내의 on-cycle 을 랜덤하게 배치하여 지속적으로 AC전력제어방법이다. 이 때 최소 전력량은 1/N이 되고 최대 전력량은 1이 되며 설정 값에 따라 on cycle의 수를 설정하여 N개의 단계로 일정하게 전력을 제어할 수 있다. PTC 열선과 온도센서를 사용한 발열 시스템에서 제안한 전력제어 방식이 전자파 발생과 온도제어 특성에서 우수함을 MATLAB simulation과 실험 및 측정을 통하여 확인하였다.

Multi-material topology optimization for crack problems based on eXtended isogeometric analysis

  • Banh, Thanh T.;Lee, Jaehong;Kang, Joowon;Lee, Dongkyu
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.663-678
    • /
    • 2020
  • This paper proposes a novel topology optimization method generating multiple materials for external linear plane crack structures based on the combination of IsoGeometric Analysis (IGA) and eXtended Finite Element Method (X-FEM). A so-called eXtended IsoGeometric Analysis (X-IGA) is derived for a mechanical description of a strong discontinuity state's continuous boundaries through the inherited special properties of X-FEM. In X-IGA, control points and patches play the same role with nodes and sub-domains in the finite element method. While being similar to X-FEM, enrichment functions are added to finite element approximation without any mesh generation. The geometry of structures based on basic functions of Non-Uniform Rational B-Splines (NURBS) provides accurate and reliable results. Moreover, the basis function to define the geometry becomes a systematic p-refinement to control the field approximation order without altering the geometry or its parameterization. The accuracy of analytical solutions of X-IGA for the crack problem, which is superior to a conventional X-FEM, guarantees the reliability of the optimal multi-material retrofitting against external cracks through using topology optimization. Topology optimization is applied to the minimal compliance design of two-dimensional plane linear cracked structures retrofitted by multiple distinct materials to prevent the propagation of the present crack pattern. The alternating active-phase algorithm with optimality criteria-based algorithms is employed to update design variables of element densities. Numerical results under different lengths, positions, and angles of given cracks verify the proposed method's efficiency and feasibility in using X-IGA compared to a conventional X-FEM.

Seismic analysis and performance for stone pagoda structure under Gyeongju earthquake in Korea

  • Kim, Ho-Soo;Kim, Dong-Kwan;Jeon, Geon-Woo
    • Earthquakes and Structures
    • /
    • 제21권5호
    • /
    • pp.531-549
    • /
    • 2021
  • Analytical models were developed and seismic behaviors were analyzed for a three-story stone pagoda at the Cheollyongsa temple site, which was damaged by the Gyeongju earthquake of 2016. Both finite and discrete element modeling were used and the analysis results were compared to the actual earthquake damage. Vulnerable parts of stone pagoda structure were identified and their seismic behaviors via sliding, rocking, and risk analyses were verified. In finite and discrete element analyses, the 3F main body stone was displaced uniaxially by 60 and 80 mm, respectively, similar to the actual displacement of 90 mm resulting from the earthquake. Considering various input conditions such as uniaxial excitation and soil-structure interaction, as well as seismic components and the distance from the epicenter, both models yielded reasonable and applicable results. The Gyeongju earthquake exhibited extreme short-period characteristics; thus, short-period structures such as stone pagodas were seriously damaged. In addition, we found that sliding occurred in the upper parts because the vertical load was low, but rocking predominated in the lower parts because most structural members were slender. The third-floor main body and roof stones were particularly vulnerable because some damage occurred when the sliding and rocking limits were exceeded. Risk analysis revealed that the probability of collapse was minimal at 0.1 g, but exceeded 80% at above 0.3 g. The collapse risks at an earthquake peak ground acceleration of 0.154 g at the immediate occupancy, life safety, and collapse prevention levels were 90%, 52%, and 6% respectively. When the actual damage was compared with the risk analysis, the stone pagoda retained earthquake-resistant performance at the life safety level.

유체-구조물 상호작용을 고려한 댐 구조체와 수압철관의 내진성능평가 (Seismic Performance Evaluation of Dam Structures and Penstock Considering Fluid-Structure Interaction)

  • 허소현;남광식;정영석;권민호
    • 토지주택연구
    • /
    • 제13권1호
    • /
    • pp.141-150
    • /
    • 2022
  • 국내 대규모 지진 이후 구조물의 내진에 대한 연구 필요성이 커짐에 따라 행정안전부에서는 기존의 내진설계기준 공통적용사항을 개정하여 국가내진성능 목표치를 상향하였으며 새로 개정된 내진설계기준의 성능목표치에 대한 연구가 필요하게 되었다. 이에 본 논문에서는 실제 노후화된 Test-Bed의 댐 제체와 내부에 매립되어 있는 수압철관과 유체를 여러 변수를 도입하여 3차원 유한요소법으로 모델링 하였으며 수압철관 내부 유체의 동수압으로 인한 거동을 분석하고 개정된 현행 내진설계 기준법에 부합하는 지진파에 대한 댐 제체와 수압철관의 안전성을 확인하였다. 3차원 유한요소해석결과 수압철관의 수충격에 의한 응력변화가 매우 작았으며 이를 통해 지진상황에서 수충격 보다 동수압의 영향이 더 큰 것을 확인할 수 있었다. 동수압이 SPH 형태인 경우 지진동으로 인한 유체의 거동과 응력 발생 위치를 유효하게 나타낼 수 있으며 취약부 분석에 더욱 용이할 것으로 분석되었다. 부식을 고려한 해석결과 수압철관이 제체의 매립되어 있기 때문에 응력 분산의 정도가 작아져 강재 항복응력의 1% 이하로 매우 작은 응력결과를 보였다. 또한 콘크리트 댐 제체의 상류 유입부의 미소 인장균열 발생 가능성이 있으나 수압철관의 응력증가에 큰 영향을 끼치지 않는 것으로 나타났으며 개정된 유효지반가속도의 지진상황에서 안전한 것으로 판단된다.

SI기법 적용을 위한 최적 모델의 선택 (Selection of Optimal Model for Structural System Identification)

  • 곽현석;권순정;이해성;신수봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권2호
    • /
    • pp.217-224
    • /
    • 2005
  • 모드자료를 이용한 SI기법을 효과적으로 적용하기 위하여 최적 모델을 선택하는 방법을 제안하였다. 축소된 유한요소 모델 대신 가능한 상세한 유한요소 모델을 정하고 SI기법으로 식별하였다. 다만 미지변수의 수를 조절하기 위하여 부재그룹 개념을 도입하였다. 최적 모델은 시도된 부재그룹 경우 중에서 최소의 통계적 오차를 갖는 것으로 선택하였다. 본 논문에서는 단경간 box-girder교에 대한 예제 수행을 통하여 제안된 방법을 검토하였다.

구치 편측확장을 위한 Precision Lingual Arch 적용시 응력분포에 관한 유한요소법적 연구 (AN ANALYSIS OF STRESS DISTRIBUTION IN THE CASE OF UNILATERAL MOLAR EXPANSION WITH PRECISION LINGUAL ARCH BY FINITE ELEMENT METHOD)

  • 구본찬;손병화
    • 대한치과교정학회지
    • /
    • 제24권3호
    • /
    • pp.721-733
    • /
    • 1994
  • Orthodontic tooth movement is closely related to the stress on the periodontal tissue. In this research the finite element method was used to observe the stress distribution and to find the best condition for effective tooth movement in the case of unilateral molar expansion. The author constructed the model of lower dental arch of average Korean adult and used $.032'\times.032'\times60mm$ TMA wire. The wire was deflected in the horizontal and vertical direction to give the 16 conditions. The following results were obtained ; 1. When the moment and force were controlled properly the movement of anchor tooth was minimized and the movement of moving tooth was maximized. 2. As the initial horizontal deflection increased the buccal displacement of both teeth was also increased. As the initial horizontal deflection increased the lingual movement of anchor tooth and the buccal movement of moving tooth increased. 3. When the initial horizontal and vertical deflection rate was 1.5 the effective movement of moving tooth was observed with minimal displacement of anchor tooth.

  • PDF

양방향 알고리즘을 이용한 2의 보수 표현 기법에 의한 디지털 필터의 설계에 관한 연구 (Study on Design of Digital filter by 2's Complement Representation using Bidirectional algorithm)

  • 이영석
    • 한국정보전자통신기술학회논문지
    • /
    • 제2권1호
    • /
    • pp.37-42
    • /
    • 2009
  • 디지털 신호 처리 분야에서 디지털 필터는 필수불가결한 요소이다. 디지털 필터는 이진수의 곱셈 및 덧셈을 기본으로 하는 것으로 많은 연산량을 필요로 한다. 디지털 필터 내의 곱셈기는 VLSI 기술을 이용한 디지털 필터의 설계에 있어 반도체 칩 내부의 넓은 영역을 차지하고 전력의 대부분을 소비하며, 필터의 critical path를 결정하여 필터의 성능을 결정하는 중요한 요소로서 작용 한다. 본 연구에서는 특히 디지털 필터의 복잡성(complexity)를 해소하고 critical path를 줄여 필터의 연산속도를 증가시키기 위한 방법으로 2의 보수로서 표현되는 이진수를 CSD(canonical signed digit)와 MSD(minimal signed digit)로 동시에 변환하여 표현하는 방법을 제안하였다. 제안된 방법은 VHDL로 구현하고 임의의 필터에 적용하여 필터의 critical path가 감소하는 것을 보였다.

  • PDF

3차원 달팽이관 모델에서의 인공와우 전극의 거동에 대한 유한요소해석 (Evaluation of the Cochlear Electrode Behavior in the 3D Human Cochlea Model by FEM Analysis)

  • 임윤섭;박세익;김용협;오승하;김성준
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권3호
    • /
    • pp.207-215
    • /
    • 2004
  • 본 연구에서는 유전 프로그램을 이용하여 6가지 형태의 금속 와이어 배치를 가진 전극을 생성하여 각 전극이 3차원 형태의 달팽이관에 미치는 기계적인 영향과 그 거동을 유한요소법을 이용하여 분석하였다. 그리고 전극이 삽입되는 달팽이관은 helico-spiral 근사방법에 의해 결정된 식을 이용하였으며, 고실계단(scala tympani)의 형태는 실제 고실계단 단면의 영상정보를 추출하여 얻어내었다. 해석결과 금속 와이어가 평행하게 배치될 경우 가장 큰 힘을 달팽이관 외벽에 전달하며, 삽입에도 가장 큰 힘이 필요한 것을 알 수 있었다. 그리고 달팽이관은 3차원 구조이므로 전극이 삽입되면서 삽입 전에 자극 사이트가 바라보도록 설정한 방향보다 조금 돌아감을 확인하였다. 이 연구의 결과로부터 전극의 강성이 외상(trauma)을 줄이는데 중요하다는 것을 알 수 있다.

Shear strength formula of CFST column-beam pinned connections

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.409-421
    • /
    • 2012
  • Recently, as the height of building is getting higher, the applications of CFST column for high-rise buildings have been increased. In structural system of high-rise building, The RC core and exterior concrete-filled tubular (CFST) column-beam pinned connection is one of the structural systems that support lateral load. If this structural system is used, due to the minimal CFST column thickness compared to that of the CFST column width, the local moment occurred by the eccentric distance between the column flange surface from shear bolts joints degrades the shear strength of the CFST column-beam pinned connections. This study performed a finite element analysis to investigate the shear strength under eccentric moment of the CFST column-beam pinned connections. The column's width and thickness were used as variables for the analysis. To guarantee the reliability of the finite element analysis, an actual-size specimens were fabricated and tested. The yield line theory was used to formulate an shear strength formula for the CFT column-beam pinned connection. the shear strength formula was suggested through comparison on the results of FEM analysis, test and yield lime theory, the shear strength formula was suggested.