• Title/Summary/Keyword: miniature society

Search Result 571, Processing Time 0.029 seconds

A Review on Cooling Technologies for Micro and Miniature Devices and Systems

  • Yoon, Jae-Sung;Choi, Jong-Won;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.2
    • /
    • pp.70-77
    • /
    • 2007
  • As electric and mechanical devices have been miniaturized and highly integrated, heat generation per unit volume has been greatly increased. Therefore, effective cooling methods for micro and miniature systems have emerged as critical issues nowadays and a lot of studies have been carried out to find an optimum cooling strategy. This paper reviews recent researches on the cooling technologies which are mainly based on micro-fabrication processes. Design, development, experiments and numerical analysis of various cooling devices are discussed and their characteristics, problems and advantages are compared.

Radiography and ct features of atherosclerosis in two miniature schnauzer dogs

  • Lee, Eunji;Kim, Hyun Woo;Bae, Hyeona;Yu, DoHyeon;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • v.21 no.6
    • /
    • pp.89.1-89.6
    • /
    • 2020
  • Two miniature Schnauzer dogs with chronic pancreatitis were investigated. Both dogs showed systemic hypertension and increased concentrations of triglycerides and C-reactive protein. Abdominal radiography revealed cylindrical calcification in the retroperitoneum, and computed tomography (CT) showed extensive calcification of the abdominal and peripheral arteries in both dogs. Metastases and other dystrophic conditions that can cause arterial calcification were excluded based on the laboratory tests, and the dogs were diagnosed with atherosclerosis ante mortem. Atherosclerosis should be considered when extensive arterial calcification is observed on abdominal radiography or CT in miniature Schnauzers.

Miniature J-T cryocooler using argon and nitrous oxide mixture

  • Hwang, Gyu-Wan;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.4
    • /
    • pp.38-42
    • /
    • 2008
  • Miniature J-T cryocooler using nitrogen or argon has been widely adopted in cooling infrared sensor for space/military application and cryosurgery. Argon or nitrogen, however, has relatively low specific cooling power compared to nitrous oxide, but the ultimate operating temperature is much lower than nitrous oxide. On the other hand, nitrous oxide has large specific cooling power, but the operating temperature is limited to its boiling point (>183K). To compromise the different characteristics of these gases, the performance of miniature J-T cryocooler using argon and nitrous oxide mixture is investigated in this paper. Three different compositions of mixture (25/75, 50/50, and 75/25 molar fraction) are blended and tested. The results are compared with the experiments of pure argon and pure nitrous oxide. The experimental results show some encouraging potentiality of mixed refrigerant J-T cryocooler. The critical clogging problem, however, was observed with argon and nitrous oxide mixture, and the lowest achievable temperature with this mixture was limited to the freezing point of nitrous oxide. The paper discusses detailed clogging process of the mixture and suggests an alternative.

Study on Cone Penetration Rate and Anisotropy in Cohesive Soils (점성토에 있어서 지반의 비등방성을 고려한 콘 관입속도에 관한 연구)

  • Kim, Dae-Kyu;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.559-566
    • /
    • 2000
  • 본 연구에서는 비등방성 응력조건 하에서 콘 관입속도가 콘 관입시험 결과에 미치는 영향을 연구하기 위하여 유한요소해석 및 Calibration Chamber를 이용한 Miniature Piezocone의 관입시험이 수행되었으며 그 결과를 비교 분석하였다. 비등방성을 고려하기 위하여 Anisotropic Soil Model이 유한요소해석에 이용되었으며 LSU/CALCHAS(Louisiana State University Calibration Chamber System)가 Miniature Piezocone의 관입시험에 이용되었다. 콘 관입속도의 영향이외에도 OCR 및 필터위치의 영향을 고찰하였다.

  • PDF

A Study on the Burr Formation of Miniature Drilling process (미소 드릴링시의 Burr 형성에 관한 연구)

  • 박동삼
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.6-11
    • /
    • 1997
  • In most machining operations, undesirable burr are formed on the edge of the workpiece adjacent to the machined surface. Such burrs are often the cause of various problems during automatic maching process. Therefore, it is very important to know characteristics of burr formation in maching process. This paper describes characteristic of exit burrs generated during miniature drilling process. In particular, the effect of spindle speed, feedrate and drill diameter on burr formaton is investigated. The result showed that exit burr height increased significantly with increasing feedrate.

  • PDF

Development of high sensitivity pressure sensor using optical fiber (광섬유를 이용한 고감도 압력센서 개발)

  • 이권형;조경재;김현철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.478-481
    • /
    • 1995
  • This paper presents the system demonstrator for an optical fiber sensor system developed as a technological evaluator suitable for generic sensric sensing applications. The new type of fiber-optic sensor employed a diaphragm displacement transforms pressure into optical intensity. Form this sensing technique, we can know the variation of source intensity, the loss of a optical fiber, and the reflectivity of the diaphragm surface. Experimental results are applied to the low-pressure transducer suitable for measuring miniature pressure.

  • PDF

Protection Method for Diameter-downsized Fiber Bragg Gratings for Highly Sensitive Ultraviolet Light Sensors

  • Seo, Gyeong-Seo;Ahn, Tae-Jung
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.221-225
    • /
    • 2018
  • We suggested the use of miniature hollow glass tubes having high ultraviolet (UV) transmission characteristics for the protection of optical-fiber-type UV sensors. We have recently proposed a highly sensitive optical sensor in the UV spectral range, using a fiber Bragg grating (FBG) coated with an azobenzene polymer as the photoresponsive material. In this study, we used UV-transparent miniature glass tubes to protect the etched FBG with the azobenzene polymer coating. This technique will be very useful for protecting various fiber-based UV sensors.

Development of a Measuring Instrument for the Coefficient of Luminous Intensity of Retro-Reflection of Miniature Telecentric Cameras (소형 텔레센트릭 카메라 광학계의 재귀반사 측정 방법 연구 및 측정 장치 개발)

  • Yeo, TaeWoon;Karasik, V.E.;Kim, Young Il
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.6
    • /
    • pp.334-339
    • /
    • 2014
  • In this paper, the optical properties of a miniature telecentric camera are studied analytically and experimentally. By means of optical properties, the luminous intensity of retro-reflection of a miniature telecentric optical system is investigated. First, from a simulation the theoretical value of the coefficient of luminous intensity of retro-reflection of a miniature telecentric system is estimated. Second, a miniature telecentric camera device is designed, and the value of the coefficient of luminous intensity of retro-reflection of the actual device is measured through experiment. From simulation and experiment, we found that both the estimated and observed values of the coefficient of luminous intensity of retro-reflection range from 0.002 to $0.03m^2/sr$ (P384200CPH: $0.0042-0.018m^2/sr$, P285200CPH: $0.0045-0.0297m^2/sr$, P321450S: $0.0021-0.00963m^2/sr$) at 1.4 to 4.9 arcminute. The results prove the significance of the mechanisms used to design the miniature telecentric camera, and the experimental method. Accordingly, with these significant results, this study contributes to the development of theory and practice in optical engineering science.

Establishment of Freezing Conditions for Improving Cryosurvival in Miniature Pig Spermatozoa (미니돼지 정액의 동결-융해 후 생존율 향상을 위한 동결 조건 확립)

  • Lee, Yong-Seung;Yoo, Han-Jun;Cheong, Hee-Tae;Yang, Boo-Keun;Woo, Jea-Seok;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • v.35 no.3
    • /
    • pp.329-334
    • /
    • 2011
  • This study was conducted to establish a freezing method of miniature pig spermatozoa. The semen 더aculated from PWG M-type miniature pig was collected by gloved-hand method. The semen was diluted with same volume extender (m-Modena B). The frozen solution used frozen solution of four different (LEY, TCG, BF-5 and m-Modena+egg yolk) for find optimal frozen solution in miniature pig sperm. The diluted semen for frozen rate assay was added to LEY solution (solution I: 11% lactose+egg yolk; solution II: solution I+glycerol+OEP), and frozen depending on freezing rate by the three different freezing methods (A: until $5^{\circ}C$ for 1 hrs, holding at $-102^{\circ}C$ for 10 min; B: until $5^{\circ}C$ for 2 hrs, holding at $-102^{\circ}C$ for 10 min; C: until $5^{\circ}C$ for 3 hrs, holding at -80 and $-102^{\circ}C$ for 10 min). Semen cooled until $5^{\circ}C$ was added with glycerol 1, 3 and 5%, and take a equilibrium time for 0, 10 and 30min. Frozen-thawed sperm were evaluated for viability, acrosomal status and morphological abnormality. The results of frozen-thawed sperm ability by frozen solution, viability was higher in LEY solution compared to other three different frozen solution. AR pattern of LEY solution were lower than other three different frozen solution. The results of freezing rate, viability was higher in B method compared to other methods (p<0.05). Acrosomal statute was intacted in A and B methods than C method. The experiment for glycerol condition was showed that sperm viability was higher in extender with 1% and 3% glycerol and equilibrium time of 0 min. The acrosome damage was lower in extender with 1% glycerol and equilibrium time of 10 min than other conditions. In conclusion, the optimal conditions for cryopreservation of miniature pig spermatozoa obtained in LEY frozen solution, cooling rate of 1~2 hrs, 1~3% glycerol concentrations and glycerol equilibrium time of 0~10 min.

Effect of Thawing Temperature on Sperm Characteristics of Frozen Semen in Miniature Pig (미니 돼지 동결정액의 융해 온도가 정자성상에 미치는 영향)

  • Choi, Won-Cheol;Yang, Mi-Hye;Lee, Yong-Seung;Cheong, Hee-Tae;Yang, Boo-Keun;Lee, Dong-Seok;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • v.31 no.3
    • /
    • pp.175-179
    • /
    • 2007
  • The objective of this study was to investigate the effect of thawing temperature on the sperm viability and acrosomal morphology for semen storage of miniature pig by the 0.5ml straw method. In this present study, sperm viability (SYBR-14/PI staining), membrane integrity (Hypoosmotic Swelling Test), acrosome intactness, intensity and capacitation status (chlorotetracycline staining) in frozen miniature pig sperm were evaluated after thawing at 37, 50 and $70^{\circ}C$ for 5, 10 and 45 sec, respectively. Interestingly, the results indicated that sperm thawed at $70^{\circ}C$ for 5 sec significantly (p<0.05) increased sperm viability, but lower the percentage of AR (acrosome reacted spermatozoa) pattern compared to sperm thawed at $37^{\circ}C$ for 45 sec and $50^{\circ}C$ for 10 sec. In terms of thawing condition, high temperature for a short time using the 0.5ml straw was improved cryosurvival of miniature pig semen. Therefore, appropriate thawing method for cryopreservation of miniature pig is required for increasing post-thawing viability.