• 제목/요약/키워드: mini-cone

검색결과 27건 처리시간 0.027초

Comparison of postoperative changes in the distal and proximal segments between conventional and sliding mini-plate fixation following mandibular setback

  • Kim, Seong-Sik;Kwak, Kyoung-Ho;Ko, Ching-Chang;Park, Soo-Byung;Son, Woo-Sung;Kim, Yong-Il
    • 대한치과교정학회지
    • /
    • 제46권6호
    • /
    • pp.372-378
    • /
    • 2016
  • Objective: The purpose of the present study was to evaluate the postoperative three-dimensional (3D) changes in the proximal segments after mandibular setback sagittal split ramus osteotomy and to compare the changes between the conventional mini-plate fixation and semi-rigid sliding plate fixation. Methods: Cone-beam computed tomography (CBCT) images were used to evaluate the postoperative 3D changes in the proximal segments during the healing process. CBCT images were superimposed using the symphysis and the lower anterior mandible as references. Results: There were no statistically significant differences between the conventional mini-plate and semi-rigid sliding plate groups (p > 0.05). With respect to the distribution of changes greater than 2 mm in the landmarks, the right condylion, right coronoid process, and left condylion showed ratios of 55.6%, 50.0%, and 44.4%, respectively, in the semi-rigid sliding plate group; however, none of the landmarks showed ratios greater than 30% in the conventional mini-plate group. Conclusions: There were no statistically significant differences in postoperative changes in the segments between the conventional mini-plate and semi-rigid sliding plate groups. Nevertheless, while selecting the type of fixation technique, clinicians should consider that landmarks with greater than 2 mm changes were higher in the semi-rigid sliding plate group than in the conventional mini-plate group.

고압 분사 디잴 인잭터의 노즐 형상이 분사 특성 및 분무 거동에 미치는 영향 (Effect of nozzle geometry on the injection characteristics and spray behavior)

  • 이창식;박성욱;전문수
    • 한국분무공학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2004
  • This paper describes the characteristics of injection rate and macroscopic behavior of fuel spray injected from common-rail type diesel injectors with different nozzle geometries. The injection rates according to the nozzle geometries were measured at different energizing duration of the injector solenoid and injection pressure by using the Bosch's injection rate meter based on the pressure variation in the tube. The spray behaviors injected from the different nozzles were visualized using the spray visualization system composed of an Ar-ion laser, an ICCD camera, and a synchronization system at various injection and ambient pressures. It is revealed that VCO nozzle has higher spray tip velocity at the early stage of injection duration and wider spray cone angle than the mini-sac nozzles. Also the spray cone angle is increased with the increase of nozzle diameter.

  • PDF

시멘트 페이스트의 유동 특성에 관한 평가방법 비교연구 (A Comparison Study Between Evaluation Methods on the Rheological Properties of Cement Paste)

  • 한천구;이건철;허영선
    • 한국건축시공학회지
    • /
    • 제6권3호
    • /
    • pp.75-82
    • /
    • 2006
  • This study investigates the influence of various blending factors on cement paste fluidity and find out the most effective evaluation method of cement paste flow, comparing flow test apparatuses such as ring flow(R-F), flow cone(F-C) and mini slump(M-S). A viscometer also measures the rheology coefficients to secure faithful numerical data. Firstly, series I examines cement paste, affected by several cement products and mineral admixture types in the range of W/B 40%, ordinary fluidity, and W/B 30%, high fluidity. In this series, the three types of cement product depended on companies, are randomly used and the mineral admixture, such as fly ash, blast furnace slag and silica fume, are incorporated in the cement paste, in response to the ratio of 10, 20, to 30%, respectively. In addition, series II studies various chemical admixture types, affecting the cement paste. This series is carried out with manufacturing companies and component types in the range of W/C 30%, high fluidity. For the manufacturing companies, randomly four products are used and for the component types, polycaboxylate, melamine, naphthalene and lignosulfonate type are chosen. Test results showed that in the fluidity test of cement paste considering various types of blending factors, R-F exhibited similar tendency with F-C and M-S. In the analysis of consistency curves measured by viscometer, the fluidity evaluation method using flow test apparatuses was significantly effective, except for the some of the low fluidity specimens. In conclusion of this study, R-F was the most convenient, faithful and effective fluidity evaluation method of cement paste.

Quantitative evaluation of alveolar cortical bone density in adults with different vertical facial types using cone-beam computed tomography

  • Ozdemir, Fulya;Tozlu, Murat;Cakan, Derya Germec
    • 대한치과교정학회지
    • /
    • 제44권1호
    • /
    • pp.36-43
    • /
    • 2014
  • Objective: The purpose of this study was to quantitatively evaluate the cortical bone densities of the maxillary and mandibular alveolar processes in adults with different vertical facial types using cone-beam computed tomography (CBCT) images. Methods: CBCT images (n = 142) of adult patients (20-45 years) were classified into hypodivergent, normodivergent, and hyperdivergent groups on the basis of linear and angular S-N/Go-Me measurements. The cortical bone densities (in Hounsfield units) at maxillary and mandibular interdental sites from the distal aspect of the canine to the mesial aspect of the second molar were measured on the images. Results: On the maxillary buccal side, female subjects in the hyperdivergent group showed significantly decreased bone density, while in the posterior region, male subjects in the hyperdivergent group displayed significantly decreased bone density when compared with corresponding subjects in the other groups (p<0.001). Furthermore, the subjects in the hyperdivergent group had significantly lower bone densities on the mandibular buccal side than hypodivergent subjects. The maxillary palatal bone density did not differ significantly among groups, but female subjects showed significantly denser palatal cortical bone. No significant difference in bone density was found between the palatal and buccal sides in the maxillary premolar region. Overall, the palatal cortical bone was denser anteriorly and buccal cortical bone was denser posteriorly. Conclusion: Adults with the hyperdivergent facial type tend to have less-dense buccal cortical bone in the maxillary and mandibular alveolar processes. Clinicians should be aware of the variability of cortical bone densities at mini-implant placement sites.

Cone-beam computed tomography-based diagnosis and treatment simulation for a patient with a protrusive profile and a gummy smile

  • Uesugi, Shunsuke;Imamura, Toshihiro;Kokai, Satoshi;Ono, Takashi
    • 대한치과교정학회지
    • /
    • 제48권3호
    • /
    • pp.189-199
    • /
    • 2018
  • For patients with bimaxillary protrusion, significant retraction and intrusion of the anterior teeth are sometimes essential to improve the facial profile. However, severe root resorption of the maxillary incisors occasionally occurs after treatment because of various factors. For instance, it has been reported that approximation or invasion of the incisive canal by the anterior tooth roots during retraction may cause apical root damage. Thus, determination of the position of the maxillary incisors is key for orthodontic diagnosis and treatment planning in such cases. Cone-beam computed tomography (CBCT) may be useful for simulating the post-treatment position of the maxillary incisors and surrounding structures in order to ensure safe teeth movement. Here, we present a case of Class II malocclusion with bimaxillary protrusion, wherein apical root damage due to treatment was minimized by pretreatment evaluation of the anatomical structures and simulation of the maxillary central incisor movement using CBCT. Considerable retraction and intrusion of the maxillary incisors, which resulted in a significant improvement in the facial profile and smile, were achieved without severe root resorption. Our findings suggest that CBCT-based diagnosis and treatment simulation may facilitate safe and dynamic orthodontic tooth movement, particularly in patients requiring maximum anterior tooth retraction.

혼화제가 시멘트 페이스트의 레오로지 성상에 미치는 영향 (Influence of Various Chemical Admixtures on Rheological Properties of Cement Paste)

  • 허영선;김종;신재경;윤섭;이건철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.675-678
    • /
    • 2005
  • Cement paste is originally the basic material and crucial factor consisting concrete. This study investigates the relationship between flow apparatuses, which are ring flow, flow cone and mini slump, in order to estimate the fluidity of cement paste. For quantitatively evaluating the measured data, this study also analyses the calibration of the rheology consistents of cement paste using viscometer. For this purpose, the present work discusses the influence of the differences of companies and ingredients, affecting the fluidity of cement paste

  • PDF

Effect of Dune Sand on the Properties of Flowing Sand-Concrete (FSC)

  • Bouziani, Tayeb;Bederina, Madani;Hadjoudja, Mourad
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권1호
    • /
    • pp.59-64
    • /
    • 2012
  • Sand-concrete is being researched for potential usage in construction in Saharan regions of Algeria, because of shortage in coarse aggregate resources. This research work deals with the effect of dune sand, available in huge quantities in these regions, on the properties of flowing sand-concrete (FSC) prepared with different proportions of dune and river sands. Mini-cone slump test, v-funnel flow-time test and viscosity measurements were used to characterize the behaviour of FSC in fresh state. The 28-day compressive strength was also determined. Test results show that an optimal content of dune sand, which makes satisfied fresh and hardened properties of FSC, is obtained. Moreover, the obtained flow index (constant b) calculated by the help of power-law viscosity model is successfully correlated to the experimental results of v-funnel flow time.

The effect of fixation plate use on bone healing during the reconstruction of mandibular defects

  • Hong, Khang Do Gia;Kim, Seong-Gon;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권5호
    • /
    • pp.276-284
    • /
    • 2019
  • Objectives: This study sought to compare efficiency results between the use of a customized implant (CI) and a reconstruction plate (RP) in mandibular defect reconstruction in an animal model. Materials and Methods: Fifteen rabbits underwent surgery to create a defect in the right side of the mandible and were randomly divided into two groups. For reconstruction of the mandibular defect, the RP group (n=5) received five-hole mini-plates without bone grafting and the CI group (n=10) received fabricated CIs based on the cone-beam computed tomography (CBCT) data taken preoperatively. The CI group was further divided into two subgroups depending on the time of CBCT performance preoperatively, as follows: a six-week CI (6WCI) group (n=5) and a one-week CI (1WCI) group (n=5). Daily food intake amount (DFIA) was measured to assess the recovery rate. Radiographic images were acquired to evaluate screw quantity. CBCT and histological examination were performed in the CI subgroup after sacrifice. Results: The 1WCI group showed the highest value in peak average recovery rate and the fastest average recovery rate. In terms of reaching a 50% recovery rate, the 1WCI group required the least number of days as compared with the other groups ($2.6{\pm}1.3days$), while the RP group required the least number of days to reach an 80% recovery rate ($7.8{\pm}2.2days$). The 1WCI group showed the highest percentage of intact screws (94.3%). New bone formation was observed in the CI group during histological examination. Conclusion: Rabbits with mandibular defects treated with CI showed higher and faster recovery rates and more favorable screw status as compared with those treated with a five-hole mini-plate without bone graft.

시멘트 페이스트의 레올로지 특성에 미치는 혼화재 변수의 영향 (Mineral Admixture Factors Affecting Rheological Properties of Cement Paste)

  • 허영선;황인성;신현섭;윤섭;이건철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.57-61
    • /
    • 2005
  • Cement paste is originally the basic material and crucial factor consisting concrete. This study investigates the relationship between flow apparatuses, which are ring flow(R-F), flow cone(F-C) and mini slump(M-S), in order to estimate the fluidity of cement Paste. For quantitatively evaluating the measured data this study also investigated the calibration of the rheology consistent, such as yield value and plastic viscosity, of cement paste using viscometer For this purpose the present work discussed the influence of 3 type of ordinary portland cement with different companies, affecting the fluidity of cement paste. and it also demonstrated the influence of the various kinds of mineral admixtures, such as fly ash(FA), blast furnace slag(BS) and silica fume(SF) and that of incorporating ratio. The author concluded that using R-F apparatus is the most effective flow test method of cement paste and it is exactly proportional to other apparatus' rheological properties.

  • PDF

비탈면 점검 효율화를 위한 휴대형 복합센서 개발 (Development of Portable Multi-function Sensor (Mini CPT Cone + VWC Sensor) to Improve the Efficiency of Slope Inspection)

  • 김종우;조윤범
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권1호
    • /
    • pp.49-57
    • /
    • 2022
  • 본 논문에서는 비탈면의 안전점검에서 지반정수를 간편하게 측정할 수 있는 휴대형 시추기에 적용이 가능한 콘 형태의 복합센서를 개발하였으며, 지반정보를 예측할 수 있는 휴대용 지반정보 계측기 (Portable Tester)를 개발하였다. 휴대가 간편한 비탈면 안전점검용 센서개발을 위해서, 비탈면취약도 평가에 필요한 지층 및 지반정보를 측정할 수 있는 센서들을 포함하며, 비탈면안전성 평가에 필요한 조사데이터(토층심도, 강도정수 등)를 자동 추출하고, 상부 자연사면 토사붕괴 징후파악을 위해 깊이별 함수비 측정도 가능하도록 복합센서로 설계하였다. 지반정보 복합센서의 선단을 구성하는 소형 전자식 콘 프로브는 CPT 및 DCPT를 수행하기 위해 개발하였으며, 직경 30mm 콘과 길이 250mm Friction Sleeve를 기본 스펙으로 콘관입력과 마찰력을 손실 없이 로드셀로 전달하기 위한 로드와 어댑터, 로드셀 모듈로 설계하였다. 복합센서의 로드셀 부분를 응용하여, 토양경도계 형태로 휴대가 간편하면서도 CPT처럼 표토층의 콘관입력을 측정하면서 동시에 슬리브 마찰력 측정을 가능하게 함으로써 좀 더 구체적인 지반정보를 예측할 수 있는 휴대용 지반정보 계측기 (Portable Tester)도 개발하였다. 개발한 센서 시스템은 실내 시험을 통해서 CPT 시험과 휴대용 지반정보 계측기 시험의 상관성을 확인하였으며, 현장시험을 통해서 CPT 콘저항값과 표준관입시험의 N치를 추정하여 현장 적용성을 검증하였다.