• 제목/요약/키워드: milliampere

검색결과 6건 처리시간 0.017초

전기충격시인체에 흐르는 전류의 실험적 고찰 (Experimental investigation of electric currents flowing through human body in electirc shock)

  • 김완배;안광윤;윤태원
    • 전기의세계
    • /
    • 제29권1호
    • /
    • pp.21-27
    • /
    • 1980
  • The effect of electric shock on human body is enormousness, which leads to warmth, tingling, and even death. The mean values of perception currents obtained on 91 men and 39 women are about 0.77(mA) for men and 0.57(mA) for women. The mean value for women is approximately seven tenths that of men. An individual can tolerate, with no adverse effects, repeated exposure to the reactions associated with currents of his let-go level, and the mean value of let-go currents obtained from 27 normal men is 6.29(mA). Lethal currents flowing human body is very dangerous even for a short time. So, it is necessary to have recourse to animal experiments ot determine lethal current for human. An analysis of experimental data indicates that body weight and shock duration are important factors in determining the lethal current. It is suggested that the relationship between current and shock duration is given by I=K/.root.T, and lethal current is proportional to body weight, where I is the current in milliampere, and T is the time in seconds.

  • PDF

PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화 (The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters)

  • 신규설;동경래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권4호
    • /
    • pp.373-379
    • /
    • 2007
  • 목 적: PET이 PET-CT로 오면서 가장 큰 차이를 보이고 있는 점은 감쇄보정을 위한 투과영상의 차이이다. PET CT에서는 CT영상을 감쇄보정에 이용하고 있으며, CT 요인들이 PET 영상의 감쇄보정시 영향을 줄 수 있을 것으로 예상된다. 본 연구에서는 CT의 관전압과 관전류의 변화에 따라 PET의 정량성 평가로 이용되는 SUV(standard uptake value)의 값이 변화가 있는지를 평가하였다. 재료 및 방법: Data spectrum's lung phantom을 이용하여 $^{18}F$-FDG 1.909 mCi(팬텀 1)와 $913\;{\mu}Ci$(팬텀 2) 각각 물과 함께 넣고 흔들어 균일한 상태를 만든 후, 관전압을 80 kVp, 100 kVp, 120 kVp, 140 kVp까지, 관전압변화 당 관전류 10 mA에서 100 mA까지 각각 10 mA씩 변화를 주어 CT 영상을 얻었다. PET 영상을 각각의 CT영상을 이용하여 재구성 하였으며, 같은 부위에서의 SUV값을 구하여 그 차이를 비교하였다. 결 과: 팬텀 1의 SUV는 관전압 80, 100, 120, 140 kVp CT영상을 이용했을 때, 각각 $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$, $12.27{\pm}0.009$로 나타났다. 팬텀 2에서는 관접압을 달리 하였을 때 각각 $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$, $4.52{\pm}0.005$의 SUV를 보였다. 이들은 모두 관전압을 달리 하였을 때 통계적으로 유의한 SUV 변화를 보이지 않았다. 또한 관전류의 변화에서도 팬텀 1, 2 모두에서 유의한 SUV 차이는 나타나지 않았다. 결 론: 본 연구 결과 CT 요인의 변화가 PET 영상에서 SUV에 유의한 영향을 미치지 않았다. 따라서 PET CT 이용 시 SUV에 유의한 영향 없이 임상적 조건에 맞게 CT 요인들을 변화 시키는 응용이 가능할 것으로 생각된다.

  • PDF

동전을 이용한 제조사 별 디지털 방사선 영상 시스템의 자동노출제어 성능 평가 (Automatic Exposure Control Performance Evaluation of Digital Radiographic Imaging System by Manufacturer Using Coins)

  • 임세훈;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, we proposed an image quality control for an automatic exposure control (AEC) of digital radiographic imaging system and tried to analyze the performance of the AEC by various manufacturer. The subjects of the experiment were analyzed for the AEC image quality evaluation using digital radiation generators from four manufacturer such as PHILIPS, GE Healthcare, SAMSUNG Healthcare, DK Medical Solution. We used as materials for the implementation of the image quality evaluation by coins (500 won, KOMSCO, Korea). This study evaluated the performance evaluation of the AEC as image quality and exposure dose (Milliampere-seconds; mAs). The image quality evaluation was tried visual assessment by two radiologic technologists and contrast to noise (CNR) by ImageJ. The exposure dose investigated mAs on digital radiation generators. The radiographic coin images acquired 360 images based on change in the control factors of the AEC, which were kVp, the consistency of field configuration and dominant zone, sensitivity and density. As a result, there was a significant difference in the AEC performance between manufacturer. The CNR by the AEC for each manufacturer showed a difference of up to about 1.9 times. The exposed tube current by the AEC for each manufacturer showed a difference of up to about 5.8 times. It is expected that our proposed evaluation method using coins could be applied as the AEC performance evaluation method in the future.

심장동맥 조영 검사 시 검사 조건에 따른 환자 선량 평가 (Evaluation of Radiation Dose to Patients according to the Examination Conditions in Coronary Angiography)

  • 조용인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.509-517
    • /
    • 2023
  • This study analyzed imaging conditions and exposure index through clinical information collection and dose calculation programs in coronary angiography examinations. Through this, we aim to analyze the effective dose according to examination conditions and provide basic data for dose optimization. In this study, ALARA(As Low As Reasonably Achievable)-F(Fluoroscopy), a program for evaluating the radiation dose of patients and the collected clinical data, was used. First, analysis of imaging conditions and exposure index was performed based on the data of the dose report generated after coronary angiography. Second, after evaluating organ dose according to 9 imaging directions during coronary angiography, with the LAO fixed at 30°, dose evaluation was performed according to tube voltage, tube current, number of frames, focus-skin distance, and field size. Third, the effective dose for each organ was calculated according to the tissue weighting factors presented in ICRP(International Commission on Radiological Protection) recommendations. As a result, the average sum of air kerma during coronary angiography was evaluated as 234.0±112.1 mGy, the dose-area product was 25.9±13.0 Gy·cm2, and the total fluoroscopy time was 2.5±2.0 min. Also, the organ dose tended to increase as the tube voltage, milliampere-second, number of frames, and irradiation range increased, whereas the organ dose decreased as the FSD increased. Therefore, medical radiation exposure to patients can be reduced by selecting the optimal tube voltage and field size during coronary angiography, maximizing the focal-skin distance, using the lowest tube current possible, and reducing the number of frames.

X-線 照射가 래트 태아의 발육에 미치는 영향 (Effect of X-irradiation on Fetal Development During Pregnancy in the Rats)

  • 오홍근;김용준
    • 한국임상수의학회지
    • /
    • 제18권2호
    • /
    • pp.146-151
    • /
    • 2001
  • This study was carried out to find if the X-irradiation being used for clinical diagnosis during pregnancy would affect fetal development and cause fetal malformation in rats or not. To determine the dose and irradiation frequency of X-irradiation and gestation period by which fetal development would be affected when irradiated during pregnancy, seventy-two Sprague Dawley female rats (8 weeks old) were used for the experiment and grouped into three according to different gestation period of 5-8 days, and 6-12 days of gestation. Experimental rats were irradiated on the daily irradiation conditions of 40, 60, 80 kvp(kilo volt peak), 150 mA(milliampere), 0.25 sec and 4 times/day for both 5-8 days and 10-13 days of gestation, and 100 kvp, 100 mA, 2 min. and 4 times/day for 6-12 days of gestation. Rats were put in a small dark box when irradiated, which animals were sacrificed on the 20th day of gestation and mean litter size, fetal body weight, fetal crown-rump length(CRL) were investigated along with pathological findings. 1. Litter size were significantly decreased in the rats which were irradiated by both 60 and 80 kvp during 5 to 8 days of gestation and by 100 kvp during 6-12 days of gestation compared to those from the control rats(p<0.05) 2. Fetal body weight was significantly decreased in the fetus from the rats which were irradiated by both 60-80 kvp during 5-8 days of gestation and by 100 kvp during 6-12 days of gestation compared to those from the control rats(p<0.05). 3. There was no significant difference of fetal crown-rump length between all the experimental rats and the controls. 4. Fetal absorption, fetal death, and fetal malformation were not observed in the fetus form the rats irradiated by 40-80 kvp during 5-8 and 10-13 days of gestation, however, the pathological findings were found in those from the rats irradiated by 100 kvp during 6-12 days of gestation. 5. The harmful effect of x-irradiation on fetal development was estimated to occur when irradiated during 5-8 days of gestation. These results indicated that even X-irradiation for clinical diagnosis could affect fetal development in the early embryonic stage and when the fetus were exposed to frequent and prolonged x-irradiation with over dose.

  • PDF

자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향 (Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System)

  • 정민규;성열훈
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.635-642
    • /
    • 2020
  • 본 연구에서는 자동노출제어장치(automatic exposure control, AEC)의 채광창 차폐정도와 농도, 감도가 관전류량과 영상품질에 미치는 영향을 분석하였다. 실험에 사용된 장비는 X선관과 간접방식의 디지털검출기가 일체형인 디지털방사선발생장치(Digital Diagnost, Philips, Netherlands)를 사용하였다. 채광창 차폐정도는 3 mm 두께의 납을 이용하여 0%부터 100%까지 12.5%씩 순차적으로 누적 차폐하여 9단계로 구분하였다. 농도는 제조사에서 제시한 3단계(+2.5, 0, -2.5)와 감도 3단계(S200, S400, S800)를 대상으로 하였다. 관전류량 평가는 관전압을 40 kVp로 고정하고 AEC 조절인자들이 교차한 81가지의 조합조건에서 자동 노출된 관전류량을 측정하였다. 영상품질평가는 자체 제작한 원뿔형 피라미드 팬텀의 방사선영상을 육안 평가하여 유효한 영상을 선발하였고 이들의 신호 대 잡음비(signal to noise ratio, SNR)을 측정하였다. 그 결과 관전류량은 채광창 차폐정도가 100%, 감도 S200, 농도 2.5일 때 60.0 mAs로 가장 많이 조사되었으며, 채광창 차폐정도가 0%, 감도 S800, 농도 -2.5일 때 0.9 mAs로 가장 적게 조사되었다. SNR은 채광창 차폐정도가 0%, 감도 S200, 농도 2.5일 때 25.2로 가장 우수하였고, 채광창 차폐정도가 25%, 감도 S800, 농도 -2.5일 때 SNR이 4.7로 가장 낮았다.