Study for Reducing Safety Distance by Installing Ammunition Storage Facility in Underground (탄약저장시설 지하화에 따른 안전거리 축소방안 연구)

  • Park, Sangwoo;Jun, Jonghoon;Choi, Hangseok;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.253-260
    • /
    • 2020
  • With increasing interest in an underground-type ammunition storage facility, several design results have been provided recently. However, since not only experts in the tunnel but also military persons in charge of ammunition have not fully understood the safety distance standard, reliable design results are not being produced. In this study, the effective design method of an underground-type ammunition storage facility was provided by analyzing the current safety distance standard. First, the critical safety distances that dominate the size of construction site for underground-type ammunition storage facilities were evaluated, which are the layout of chambers and the configuration of the entrances. Then, the decreasing effect of inter-chamber distance was studied according to the rock type and the storage density of ammunition. In addition, the method of designing tunnels with parallel lines and two-floors was considered for arranging more chambers while complying with the safety distance standards. In particular, numerical simulations were carried out to determine the satisfaction of the safety distance standards when an underground-type ammunition storage facility is composed of two-floor and the decreasing effect of inter-chamber distance according to the inner explosive pressure reduction. Finally, the method to adjust the size of entrances and the path of pressure were studied for decreasing the safety distance at the entrance.

A Study on Optimal Allocation of Short Surface-to-Air Missile (단거리 지대공 미사일의 최적배치에 관한 연구)

  • 이영해;남상억
    • Journal of the military operations research society of Korea
    • /
    • v.26 no.1
    • /
    • pp.34-46
    • /
    • 2000
  • The object of this study is to construct a model for an optimal allocation of short surface to air missile defending our targets most efficiently from hostile aircraft´s attack. For the purpose of this, we analyze and establish facility allocation concept of existing models, apply set covering theory appropriate to problem´s properties, present the process of calculating the probability of target being protected, apply Sherali-Kim´s branching variable selection strategy, and then construct the model. As constructed model apply the reducing problem with application, we confirm that we can apply the large scale, real problem.

  • PDF

The Study on Assessment of Protective Capacity of the Reinforced Concrete Box-type Artillery Positions (철근콘크리트조 박스형 포상의 방호성능 평가)

  • Baek, Jonghyuk;Kim, Suk Bong;Son, Kiyoung;Park, Young Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.275-281
    • /
    • 2014
  • Although self-propelled artilleries are mobile equipment, they need their own covered-positions for survival against preemptive strikes. The most important military requirement is enough protective capacity against blast pressure caused by explosion. This paper aims to assess the protective capacity of the newly-placed concrete box-type artillery positions using accurate structural geometric models as well as soil-structure interaction analysis. The commercial program is used to model the structural geometry of the positions. In order to describe the correct wave propagation in the backfill along with soil-structure interaction, used parameters in shock equation of state are selected based on the related studies as well as theories and then their final results are verified with the ones calculated with empirical equations in the US Unified Facility Criteria. In sum, it could be concluded that the protective capacity of the newly-built positions satisfies the protective structural requirement.

A Study on Development of Cost Index Model for Military Facilities Construction (군 시설공사의 공사비지수 개발에 관한 연구)

  • Park Jong-Won;Son Bo-Sik;Lee Hyun-Soo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.256-260
    • /
    • 2004
  • As a large portion of defence budget are alloted for military facility construction, reasonable budget estimation in the planning stage has been officers' main concerns. However the proper estimation of construction cost is difficult to be carried out due to the absence of systematic criteria. To improve the budget estimation for military facility construction, this study proposes a cost index model which can convert historical cost to current cost. Thus the developed cost index would enhance effectiveness of budget estimation process 3nd support reasonable decision making. This cost index model is developed by analyzing historical cost data with statistical methodology The study is executed by following process. First, factors which affect construction cost for the most are selected by analyzing historical cost data. second, the selected factors are categorized material cost, labor cost and equipment cost, and weights of those factors are calculated by dividing the cost of each factor by total item costs. Last, cost index is developed by using weighted average method.

  • PDF

Capabilities Required for Underground Facility Operations in Korean Megacities (한국 메가시티 지하시설 작전에 요구되는 능력)

  • Jun Hak Sim;Seung Jin Jo;Jun Woo Kim;Ji Woong Choi;Won Jun Choi;Sun Il Yang;Sang Hyuk Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.267-272
    • /
    • 2024
  • Recently, major advanced countries are fostering megacities through policy for reasons such as solving population problems, political and economic issues, and strengthening national competitiveness. The trend of change is accelerating. In Korea, following Seoul and Gyeonggi, mega city policies are being promoted in Busan, Ulsan, Gyeongnam, Daegu and Gyeongbuk, Gwangju and Jeonnam, and Daejeon, Sejong, South Chungcheong and North Chungcheong areas. Due to this urbanization phenomenon, military experts predict that the future battlefield environment will be space or a large city (mega city). From this perspective, Korea will not be able to effectively respond to the threats facing megacities if it does not prepare in advance. Therefore, underground facility operation capabilities optimized for the huge scale of the mega city and the characteristics of the underground operational environment are required. Against this background, the characteristics of the underground operational environment of mega cities and cases of preparation for underground facility operations in advanced military countries such as the United States and Israel were analyzed. Based on this, the capabilities required for underground facility operations suitable for the underground operational environment within Korean megacities are developed from an idea perspective to military organization and combat system, securing special equipment and materials to ensure combatant survival, developing small unit combat techniques, and establishing a training system. It was presented with priority given to.

A Study on the Facility Layout and Signal-fire Stand of Border Signal-fire in Chosun Dynasty (조선시대 연변봉수(沿邊烽燧)의 배치형식 및 연대(煙臺)에 관한 연구)

  • Lee, Chul-Young;Yoon, Jae-Woong
    • Journal of architectural history
    • /
    • v.15 no.5
    • /
    • pp.41-56
    • /
    • 2006
  • Signal fire was a communication system which deliver urgent news by smoke and light. It informed the condition of the border to the central government and the military base rapidly. This research was to analyze the border signal-fire which is the main facility of military protective duty for safety of sea side in chosun dynasty. The results of this research were described separately as follows. 1. The border signal-fire has three types of facility layout, The majority was one-site, near two-site, separate type. The majority was near two-site type. 2. Plan configuration of signal-fire stand which is separated with circle, oval, round-rectangular and rectangular type roughly was constructed with circle type generally. Four types of signal-fire stand was observed in southern and western sea side impartially. However, in eastern side, circle type of signal-fire stand was mainly found. Therefore, regional characteristics could be considered partially. 3. The height of signal-fire stand was about 8~10m. The diameter of combustion chamber on the signal-fire stand was 2~3m in circle type, and the dimension of rectangular type was about $1.9{\times}1.9{\sim}3.2{\times}3.0m$. 4. Building base that protect ground moisture and infilteration of rainfall was found in 10 border singal-fire, the height of it was about 0.3m~2.5m.

  • PDF

Feasibility Study of a Corrugated Steel Protective Structure for Ammunition Test Facility (탄약시험장의 강재 방호구조물 적용성 분석 연구)

  • Han, Jae Duk;Kim, Donghee;Kim, Sungkon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.671-679
    • /
    • 2022
  • Harmful factors such as shock waves and fragments are generated at domestic ammunition testing sites and military shell shooting training sites due to frequent shooting and explosion tests. As a result, complaints from local residents are rapidly increasing, and there is a high risk of damage to facilities and human life. The recently constructed ammunition test site built a test facility for firing artillery and rocket propulsion in a narrow area with a radius of 300 m due to site restrictions, but damage to the facility is accumulating because there is no adequate protective structure. Therefore, in this study, quantitative data on harmful factors such as noise, vibration, shock wave, and thermal effect generated between artillery firing and rocket propulsion tests were measured, and explosion pressure characteristics were analyzed to design a protective structure, and use Autodyn to protect performance. to perform verification.

A Study on the Management Diagnosis of Military Libraries in Korea by Analyzing Management Evaluation (우리나라 병영도서관의 평가결과 분석을 통한 운영 진단 연구)

  • Cha, Sung-Jong;Han, Jong Yup
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.47 no.4
    • /
    • pp.49-78
    • /
    • 2013
  • This article examines how to improve military library services by evaluating management and performance of 160 Korean military libraries in 2011. Results indicated that the average performance rate in entire areas was 59.4%. The 'facility' area and 'inter-library cooperation' area showed high performance rates (79.2% and 71.0% respectively). On the other hand, the 'strategic management plan' area and 'support' area showed relatively low performance rates (28.3% and 33.0% respectively). Results concluded that a strong commitment for strategic planning and execution by the authorities is required to enhance military library services in the future. Also, the implications of annual evaluation on military libraries should be taken accounted for improvement plans and ultimately lead to the establishment of revitalization policies for military library services.

Community-Associated Methicillin-Resistant Staphylococcus aureus Colonization in the Upper Respiratory Tracts of Korean Military Recruits

  • Choi, Chang-Min;Kang, Cheol-In;Kim, Young-Keun;Heo, Sang-Taek;Kim, Chang-Hoon;Song, Jae-Kyung;Jung, Hee-Saeng
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.5
    • /
    • pp.409-412
    • /
    • 2009
  • Background: Several large outbreaks have demonstrated the threat of community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) in close-contact environments, such as occurs during training and quartering of military recruits training. In South Korea, which is a hospital or healthcare-associated MRSA prevalent area, military service is compulsory for all healthy young men. We surveyed and determined the extent of CA-MRSA colonization in the upper respiratory tracts of Korean military recruits. Methods: The Korean military recruits who were enrolled in a military training facility from November 2004 to March 2005 were eligible for this study. Sputum or nasopharyngeal swap was obtained from randomly selected subjects who displayed upper respiratory tract symptoms. Results: Of the 181 participants, 32 participants (17.7%) were colonized with S. aureus, and 12 participants (6.6%) were colonized with MRSA. Among the cases that were colonized with S. aureus, 37.5% (12/32) were colonized with MRSA. Antimicrobial susceptibility testing showed resistant patterns that were suggestive of the CA-MRSA strains for all of the MRSA isolates. Conclusion: This study of Korean military recruits found a great deal of showed MRSA colonization in them, and the antimicrobial resistant profile that was suggestive of a CA-MRSA strain. Further efforts to prevent the spread of MRSA infections and careful monitoring for CA-MRSA outbreaks are warranted, especially in a high risk group such as military recruits.

A Transformation Military Databases based on the Relational Data model into XML Databases (관계형 데이터 모델 기반 군사용 데이터베이스의 XML 데이터베이스로의 변환)

  • Kim, Chang-Seok;Kim, Eong-Su
    • Journal of National Security and Military Science
    • /
    • s.1
    • /
    • pp.269-310
    • /
    • 2003
  • AS Extensible Markup Language(XML) is emerging as the data format of the Internet era, there are increasing needs to efficiently transform between database and XML documents. In this paper, we propose a schema transformation method from relational database to XML database. To transform the schema, we represent input schema as Entity-Relationship diagram. Entity-Relationship model translator scans the input Entity-Relationship diagram using BFS (breadth First Search) and translates the diagram into hierarchical structure model. The XML Schema generator produces XML Scema code using the transformed hierarchical structure model. The proposed method has a merit that having reusability facility of XML Schema property in comparison with existing researches.

  • PDF