• Title/Summary/Keyword: mid-frequency electrical stimulation

Search Result 3, Processing Time 0.016 seconds

Effects of Interfering Current Stimulation on Vastus Medialis Oblique and Vastus Lateralis Activity and Ratio during Squat Exercise (스쿼트 운동 시 적용된 중주파 전기자극이 안쪽빗넓은근과 가쪽넓은근의 근활성도 및 근활성비에 미치는 영향)

  • Kim, Chung-Yoo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.4
    • /
    • pp.283-289
    • /
    • 2021
  • Purpose : The purpose of this study is to investigate the effect of mid frequency electrical stimulation during squat exercise on the muscle activity and muscle activity ratio of vastus medialis oblique and vastus lateralis, and to prepare scientific basic data for exercise intervention using mid frequency electrical stimulation. Methods : This study was conducted with students from University C located in Busan, and among a total of 123 subjects, 12 subjects who complained of knee joint dysfunction between 80 and 90 points using the Kujala patellofemoral score (KPS) were used. All subjects participated in the experiment for 3 days, and MVIC values were measured for normalization of muscle activity values on the first day. For the two days, participants participated in the experiment and performed squat exercise or squat exercise receiving mid-frequency electrical stimulation in random order. Measurements were taken in the squat position immediately after the squat exercise, and muscle activities of vastus medialis oblique and vastus lateralis were measured. The measured data were compared through the dependent t test, and the statistical significance level was set to .05. Results : According to the results of this study, in the case of applying mid-frequency electrical stimulation together in the ratio of vastus medialis oblique and vastus lateralis muscle activity during squat exercise, higher values were observed compared to the case of not applying mid-frequency electrical stimulation together, and statistically significant. Also, when mid-frequency electrical stimulation was applied to both vastus medialis oblique and vastus lateralis activities during the squat exercise, higher values were shown compared to the case where the mid-frequency electrical stimulation was not applied together, but there was no statistically significant difference. Conclusion : The results of this study reported that mid-frequency electrical stimulation provided to vastus medialis oblique increased the muscle activity ratio of vastus medialis oblique and vastus lateralis. Therefore, the improvement of coordination due to the enhancement of the activity of vastus medialis oblique through mid-frequency electrical stimulation will be more helpful in the treatment of patellofemoral pain syndrome patient. In addition, it is hoped that the electrical stimulation method applied to exercise will be widely used.

A 4×32-Channel Neural Recording System for Deep Brain Stimulation Systems

  • Kim, Susie;Na, Seung-In;Yang, Youngtae;Kim, Hyunjong;Kim, Taehoon;Cho, Jun Soo;Kim, Jinhyung;Chang, Jin Woo;Kim, Suhwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.129-140
    • /
    • 2017
  • In this paper, a $4{\times}32$-channel neural recording system capable of acquiring neural signals is introduced. Four 32-channel neural recording ICs, complex programmable logic devices (CPLDs), a micro controller unit (MCU) with USB interface, and a PC are used. Each neural recording IC, implemented in $0.18{\mu}m$ CMOS technology, includes 32 channels of analog front-ends (AFEs), a 32-to-1 analog multiplexer, and an analog-to-digital converter (ADC). The mid-band gain of the AFE is adjustable in four steps, and have a tunable bandwidth. The AFE has a mid-band gain of 54.5 dB to 65.7 dB and a bandwidth of 35.3 Hz to 5.8 kHz. The high-pass cutoff frequency of the AFE varies from 18.6 Hz to 154.7 Hz. The input-referred noise (IRN) of the AFE is $10.2{\mu}V_{rms}$. A high-resolution, low-power ADC with a high conversion speed achieves a signal-to-noise and distortion ratio (SNDR) of 50.63 dB and a spurious-free dynamic range (SFDR) of 63.88 dB, at a sampling-rate of 2.5 MS/s. The effectiveness of our neural recording system is validated in in-vivo recording of the primary somatosensory cortex of a rat.

Statistical Analysis of Brain Activity by Musical Stimulation (음악적 자극에 의한 뇌 활성도의 통계적 해석)

  • Jung, Yu-Ra;Jang, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.89-94
    • /
    • 2021
  • In this paper, we presented the results of analysis with data obtained through EEG measurements to confirm the effect of musical stimulus when performing mathematical tasks. While the subject was solving a mathematical task, favorite and unfavorite music classified according to the subject's preference were presented as musical stimulus and the tasks were divided into memorization task and procedure task. The data measured in the EEG experiments was divided into theta waves, SMR waves and mid-beta waves which are the frequency bands related to concentration to compare the relative power spectrum values. In our results, in the case of comparing no music with favorite music and no music with unfavorite music, a significant difference was observed in the several channels, and the average difference was shown in the channels F3 and F4 of the frontal lobe. In that channels, the power was found to be greater when the music was presented than the case where there was no music. Depending on the subject's preference, it was confirmed that favorite music showed greater brain activity than unfavorite music.