• Title/Summary/Keyword: microwave imaging

Search Result 93, Processing Time 0.032 seconds

MoM Forward Solver for Medical Microwave Imaging (의용 전자파 영상을 위한 모멘트법 순방향 해석 알고리즘)

  • Kim, Bo-Ra;Lee, Taek-Kyung;Son, Seong-Ho;Jeon, Soon-Ik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.797-805
    • /
    • 2009
  • In this paper, we developed MoM(Moment of Method) forward solver to implement the inverse scattering by using BIM(Born Iterative Method) for the detection of cancer in human body Especially, we adopted two-dimensional breast structure to analyze electromagnetic scattered phenomena. For the two-dimensional scattering structure, the integral equations is solved with MoM employing two-dimensional Green's function. Also, calculated results are compared with the measured results obtained from breast cancer detecting equipment.

Ultra Wideband (UWB) - Introduction and Signal Modeling

  • Manandhar, Dinesh;Shibasaki, Ryosuke
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1421-1423
    • /
    • 2003
  • Ultra Wideband is a new technology from commercial or civilian application viewpoint. It uses already allocated radio spectrum without causing significant interference to other users. It uses very low power, which is below the thermal noise of the receiver and is inherently difficult to detect by un-intentional users. Since, FCC approved the regulation for the commercial use of UWB in February 2002, the development of UWB technology is drastically gaining momentum. However, the technology itself is not new. It has already been used in military applications. UWB has three basic areas of applications, which are communication, positioning and imaging (UWB Microwave). The main commercial application will be for communication since it has very high data transfer rate for short distance. It can also be used for both indoor and outdoor 3-D positioning. Another important application is imaging like microwave remote sensing. An UWB sensor can pass through doors and walls and hence detect the objects inside the room. In this paper, we will introduce about UWB technology along with it’s various possible applications. We will also present some models to generate UWB signal and it’s analysis using signal-processing tools.

  • PDF

Algorithm Study for Diagnosis the Breast Cancer Using LMA and FDTD (LMA와 FDTD를 이용한 유방암 진단용 알고리즘 연구)

  • Seo, Min-Gyeong;Kim, Tae-Hong;Mun, Ji-Yeon;Jeon, Soon-Ik;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1124-1131
    • /
    • 2011
  • In this paper, image reconstruction algorithm for breast cancer detection using MT(Microwave Tomography) was investigated. The breast cancer detection system under development uses 16 transmit/receive antennas. The signal waveform was a sinusoidal wave at 900 MHz. To solve the 2D inverse scattering problem, we used the 2D FDTD (Finite Difference Time Domain) method for forward calculation and LMA(Levenberg-Marquardt Algorithm) for optimization. The result of the image reconstruction using the numerical phantom by MRI(Magnetic Resonance Imaging) obtained from real patient of breast cancer showed that we can detect the position of the tumor accurately.

Live Electrooptic Imaging Camera for Real-Time Visual Accesses to Electric Waves in GHz Range

  • Tsuchiya, Masahiro;Shiozawa, Takahiro
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.290-297
    • /
    • 2011
  • Recent progresses in the live electrooptic imaging (LEI) technique are reviewed with emphasis on its functionality of real-time visual accesses to traveling electric waves in the GHz range. Together with the principles, configurations, and procedures for the visual observation experiments by an LEI camera system, the following results are described as examples indicating the wide application ranges of the technique; Ku-band waves on arrayed planar antennas, waves on a Gb/s-class digital circuit, W-band waves traveling both in slab-waveguide modes and aerially, backward-traveling wave along composite right/left-handed transmission line, and, waves in monolithic microwave integrated circuit module case.

Application of terahertz spectroscopy/imaging technology for food quality and safety management (식품의 품질 및 안전 관리를 위한 테라헤르츠 분광/영상 기술의 응용)

  • Lee, Sang Yoo;Woo, So Young;Chun, Hyang Sook
    • Food Science and Industry
    • /
    • v.51 no.1
    • /
    • pp.26-36
    • /
    • 2018
  • Terahertz (THz) represents the portion of the electromagnetic radiation between the microwave and the infrared region and is within the frequency range of 0.1-10 THz. The ability of THz waves to pass through a wide variety of packaging materials, combined with their ability to characterize the molecular structure of many substances makes it an attractive tool for the application of food quality and safety management. This review provides current information on application of THz spectroscopy/imaging technology for food quality and safety management. The THz spectroscopy/imaging technology has been shown to be useful for detecting foreign bodies, vitamin/moisture, pesticides, antibiotics, melamine etc. However, major barriers to the adoption of THz spectroscopy/imaging for food quality and safety management include THz signal loss in heterogeneous food matrices, high costs of sources and detectors, and absence of a library for the wide group of food compounds. Further research is needed to overcome these barriers.

Development of MR Compatible Coaxial-slot Antenna for Microwave Hyperthermia (초고주파 가열치료를 위한 MR 호환 동축 슬롯 안테나의 개발)

  • Kim, T.H.;Chun, S.I.;Han, Y.H.;Kim, D.H.;Mun, C.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.333-340
    • /
    • 2009
  • MR compatible coaxial-slot antenna for microwave hyperthermia was developed while its structure and size of each part were determined by computer simulation using finite element method(FEM). Its local heating performance was evaluated using tissue-mimic phantom and swine muscles. 2% agarose gel mixed with 6mM/$\ell$ $MnCl_2$ as a biological tissue-mimic phantom was heated by the proposed antenna driven by a 2.45GHz microwave generator. The temperature changes of the phantom were monitored using multi-channel digital thermometer at the distance of 0mm, 5mm, 10mm and 20mm from the tip center of the antenna. Also muscle tissue of swine was heated for 2 and 5minutes with 50W and 30W of microwave generator powers, respectively, to evaluate the local heating performance of the antenna. MRI compatibility was also verified by acquiring MR images and MR temperature map. MR signals were acquired from the agarose gel phantom using $T2^*$ GRE sequence with 1.5T clinical MRI scanner(Signa Echospeed, GE, Milwaukee, WI, U.S.A.) at Pusan Paik Hospital and were transferred to PC in order to reconstruct MR images and temperature map using proton resonance frequency(PRF) method and laboratory-developed phase unwrapping algorithm. Authors found that it has no severe distortion due to the antenna inserted into the phantom. Finally, we can conclude that the suggested coaxial-slot antenna has an excellent local heating performance for both of tissue-mimic phantom and swine muscle, and it is compatible to 1.5T MRI scanner.

Vulcanization Efficiency of Non-polar Rubber Compounds by Microwave (마이크로파를 이용한 비극성 고무컴파운드의 가황 효율)

  • Jung, U-Sun;Lee, Won-Ki;Lim, Kwon-Tack
    • Polymer(Korea)
    • /
    • v.35 no.3
    • /
    • pp.228-231
    • /
    • 2011
  • The rate of vulcanization of nonpolar ethylene-propylene-diene terpolymer(EPDM)/carbon black compounds was investigated by using hot air and microwave as a heating source. The present study parameters such as heating source, sample thickness, and loading of an additive. The compound thickness was the main factor in the hot air vulcanization. It was due to the poor thermal conductivity of EPDM; that is, the thicker thickness, the lower vulcanization rate. For 100% vulcanization, the compound with 3 mm thickness required 7 min at $250^{\circ}C$ in the hot air system. However, the vulcanization of EPDM compounds by microwave system was not affected by the thickness while strongly dependent on the amount of a polar additive, carbon black. A compound with 80 phr of carbon black was perfectly vulcanized within 30 sec. These results suggest that the use of microwave as a heating source is an effective method for the vulcanization of compounds including a polar component.

PHASE-EXTENST10N INVERSE FILTERING ON REAL SAR IMAGES (실제 SAR 영상에 대한 위상 확장 역필터링의 적용)

  • Do, Dae-Won;Song, Woo-Jin;Kwon, Jun-Chan
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.547-550
    • /
    • 2001
  • Through matched filtering synthetic aperture radar (SAR) produces high-resolution imagery from data collected by a relative small antenna. While the impulse response obtained by the matched filter approach produces the best achievable signal-to-noise ratio, large sidelobes must be reduced to obtain higher-resolution SAR images. So, many enhancement methods of SAR imagery have been proposed. As a deconvolution method, the phase-extension inverse filtering is based on the characteristics of the matched filtering used in SAR imaging. It improves spatial resolution as well as effectively suppresses the sidelobes with low computational complexity. In the phase-extension inverse filtering, the impulse response is obtained from simulation with a point target. But in a real SAR environment, for example ERS-1, the impulse response is distorted by many non-ideal factors. So, in the phase-extension inverse filtering for a real SAR processing, the magnitudes of the frequency transfer function have to be compensated to produce more desirable results. In this paper, an estimation method to obtain a more accurate impulse response from a real SAR image is studied. And a compensation scheme to produce better performance of the phase-extension inverse filtering is also introduced.

  • PDF

Inverse Brightness Temperature Estimation for Microwave Scanning Radiometer

  • Park, Hyuk;Katkovnik, Vladimir;Kang, Gum-Sil;Kim, Sung-Hyun;Choi, Jun-Ho;Choi, Seh-Wan;Jiang, Jing-Shan;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.604-609
    • /
    • 2002
  • The passive microwave remote sensing has progressed considerably in recent years. Important earth surface parameters are detected and monitored by airborne and space born radiometers. However the spatial resolution of real aperture measurements is constrained by the antenna aperture size available on orbiting platforms and on the ground. The inverse problem technique is researched in order to improve the spatial resolution of microwave scanning radiometer. We solve a two-dimensional (surface) temperature-imaging problem with a major intention to develop high-resolution methods. In this paper, the scenario for estimation of both radiometer point spread function (PSF) and target configuration is explained. The PSF of the radiometer is assumed to be unknown and estimated from the observations. The configuration and brightness temperature of targets are also estimated. To do this, we deal with the parametric modeling of observation scenario. The performance of developed algorithms is illustrated on two-dimensional experimental data obtained by the water vapor radiometer.

  • PDF

Effect of Precipitation on Sea Surface Wind Scatterometry

  • Yang, Jilong;Zhang, Xuehu;Chen, Xiuwan;Esteban, Daniel;McLaughlin, David;Carswell, Jim;Chang, Paul;Black, Peter;Ke, Yinghai
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1359-1361
    • /
    • 2003
  • A set of microwave remote sensing data collected with the newly developed UMass Imaging Wind and Rain Airborne Profiler (IWRAP) during the 2002 Atlantic Hurricane Season was analyzed to further our understanding of the effect of precipitation on scatterometer wind vector retrieval. Coincident surface wind speed and precipitation measurements were provided by the UMass Simultaneous Frequency Microwave Radiometer (SFMR). The differences between the wind estimations from IWRAP and SFMR under precipitation conditions of 0-100mm/hr and wind speed of 0-60m/s was calculated, from which the effect of precipitation on the wind vector retrieval using scatterometry is analyzed qualitatively.

  • PDF