• 제목/요약/키워드: microwave Oven

검색결과 327건 처리시간 0.029초

Golf Club Head용 감나무재의 Microwave 건조 (II) - 감나무 블럭의 건조 경과와 온도 변화 - (Microwave Drying of Persimmon Blocks for Golf Club Head (II) - Drying Curves and Temperature Distribution of Persimmon Blocks -)

  • 강호양
    • Journal of the Korean Wood Science and Technology
    • /
    • 제23권3호
    • /
    • pp.28-32
    • /
    • 1995
  • The presteamed or prefrozen persimmon blocks of 10cm ${\times}$ 10cm ${\times}$ 15cm were air-dried at room temperature until about 30% moisture content, and then were dried in a MW oven. During drying their internal temperatures were monitored with thermo-couple probes. The presteamed and prefrozen blocks didn't show any improvement in drying rate and moisture gradient when compared with the controls. Checks appeared on the surfaces of most presteamed blocks during air-drying. It has been clearly revealed that the maximum weight, loss must, be less than 2g/min during MW drying to prevent internal checking and that MW drying reduced moisture gradients inside blocks. MW dried the persimmon blocks 440 times faster than conventional kiln.

  • PDF

전자 오븐의 누설 고주파 자동 검사 시스템 설계와 제작 (Design and manufacture of atomatic microwave leakage inspection system)

  • 이만형;송지복;이석희;정영철;안희태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.492-496
    • /
    • 1987
  • The testing philosophy and control schemes are investigated and applied to construct the Automatic Microwave Leakage Inspection System (AMLIS) . AMLIS is consists of three major parts such as Material Handling Mechanism, Fine Positioning Mechanism and Scanning Mechanism. The material Handling unit is designed to perform loading and unloading microwave oven onto the testing point by pneumatic cylinder and vacuum pump. The Fine positioning part includes X-Y-.THETA. table and distance sensing equipment. The scanning part is composed of five SCARA robots, which traverse X-Y-Z catesian coordinates respectively. The leakage testing probes are placed at the end of this each robot then the path and speed are both controlled via microprocessors. A performance test of this system combined with electric parts and software is done and the basic major function of system are accomplished.

  • PDF

Using Microwave Irradiation to Prepare New Poly(amide-imide)s Containing Tetrahydropyrimidinone, Tetrahydro-2-thioxopyrimidine, and Trimellitic Rings in Their Main Chains: Synthesis and Characterization

  • Faghihi Khalil;Hagibeygi Mohsen
    • Macromolecular Research
    • /
    • 제13권1호
    • /
    • pp.14-18
    • /
    • 2005
  • Under irradiation in a microwave oven, six novel poly(amide-imide)s containing tetrahydropyrimidinone, tetrahydro-2-thioxopyrimidine moieties and trimellitic rings in their main chains were synthesized through the polycondensation reaction of N,N'-(4,4'-diphenylether)bis(trimellitimide) diacid chloride with six different derivatives of tetrahydropyrimidinone and tetrahydro-2-thioxopyrimidine in the presence of a small amount of a polar organic medium, such as o-cresol. The polycondensation proceeded rapidly and completed within 7-9 min, producing a series of new poly(amide-imide)s in high yield that showed inherent viscosities in the range 0.33-0.52 dL/g. These poly(amide-imide)s were characterized by elemental analysis, viscosity measurement, thermal gravimetric analysis, solubility test, and FT-IR spectroscopy. All of the polymers were soluble at room temperature in polar solvents such as N,N-dimethylacetamide, N,N-dimethylformamide, dimethylsulfoxide, tetrahydrofuran, and N-methyl-2-pyrrolidone.

Microwave Assisted Rapid Synthesis of Novel Optically Active Poly(amide-imide)s Based on N-Trimellitylimido-L-Leucine Diacid Chloride and Hydantoin Derivatives

  • Faghihi, Khalil
    • Macromolecular Research
    • /
    • 제12권3호
    • /
    • pp.258-262
    • /
    • 2004
  • We have developed facile and rapid polycondensation reactions of N-trimellitylimido-L-leucine diacid chloride 1 with eight different derivatives of hydantoin compounds 2a-h, in the presence of a small amount of a polar organic medium, such as Ο-cresol, by using a domestic microwave oven. The polycondensation reactions proceeded rapidly-they were complete within 7-9 min-to produce a series of novel optically active poly(amide-imide)s (3a-h) in high yield with inherent viscosities of 0.33-0.51 dL/g. We characterized the resulting poly(amide-imide)s by elemental analysis, thermal gravimetric analysis (DSC, TGA, and DTG), and FTIR spectroscopy, and by measuring their viscosities, specific rotations, and solubilities. All of the polymers were soluble at room temperature in polar solvents such as N ,N-dimethylacetamide, N,N-dimethylformamide, dimethylsulfoxide, tetrahydrofuran, and N-methyl-2-pyrrolidone.

Development of Continuous Flow Microwave Digestion Procedures for Analysis of Trace Metal in Water Using Ion Chromatography

  • Youn Doo Kim;Gae Ho Lee;Hyung Seung Kim;Dong Soo Kim;Kwang Kyu Park
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권9호
    • /
    • pp.786-791
    • /
    • 1994
  • A simple and rapid sample pretreatment process necessary for determination of metal oxides in water was proposed. Samples were injected into the continuous-flow tube installed inside the microwave oven and the treated samples were cooled before entered to the Ion Chromatography (IC) or Inductively Coupled Plasma (ICP). By coupling this microwave digestion system with IC or ICP, a fully automatic analytical procedures may be easily established. In this study, two different types of digestion methods were considered; the open tubing method (OTM) and the restraint tubing method (RTM). The RTM was proved to be 3 times faster in digestion period and 10 times higher in detection range than the OTM. Validation of proposed sample digestion system was carried out by using an ICP. The results showed that both of continuous-flow methods, the OTM and the RTM were comparable in accuracies with the conventional batch-type vessel digestion method.

Blowout of Rubber Vulcanizates: Influences of Cure Systems, Content of Carbon Black, and Organic Addities

  • 최성신;김익식
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권2호
    • /
    • pp.174-178
    • /
    • 1998
  • Blowout of NR and SBR vulcanizates was studied using a microwave oven. Rubber vulcanizates with different contents of carbon black (0, 30, 50, 70 phr) and various cure systems (conventional, semi-EV, and EV) were prepared. Unfilled rubber vulcanizates did not exploded by irradiation of microwave, while carbon black-filled ones exploded within 10 min. A blowout time of the carbon black-filled rubber vulcanizate decreases with an increase of the content of carbon black in the vulcanizate. A blowout temperature of the organic additive-extracted vulcanizate is higher than that of the not-extracted one, but the extracted vulcanizate blows out faster than the not-extracted one. A blowout temperature of the overcured vulcanizate is higher than that of the undercured one with the same cure system. Temperatures of unfilled SBR vulcanizates heated by the microwave irradiation are lower than those of unfilled NR ones. The carbon black-filled SBR vulcanizates blow out at higher temperatures than the carbon black-filled NR ones. Blowout times of the carbon black-filled SBR vulcanizates are longer than those of the carbon black-filled NR ones.

즉석편의 식품용 포장재의 전자레인지 가열에 의한 변형 원인 분석 (Analysis of the Causes of Deformation of Packaging Materials Used for Ready-to-Eat Foods after Microwave Heating)

  • 윤찬석;홍승인;조아름;이화신;박현우;이근택
    • 한국식품과학회지
    • /
    • 제47권1호
    • /
    • pp.63-69
    • /
    • 2015
  • 전자레인지 가열조리용 편의식품류는 레토르트 처리되어 장기간 저장 안정성이 부여되는 장점이 있는 반면, 높은 가열 조건으로 인하여 식품의 품질 저하뿐 아니라 내용물의 흡착에 의한 포장재의 착색이나 오렌지필과 같은 물리적 변화가 발생되기도 한다. 일부 매운 소스 제품들의 전자레인지 가열 조리 시 특정 부위에서 심한 포장재의 열 변형 현상이 확인되었다. 열화상카메라와 광섬유온도계를 이용하여 전자레인지 가열 중 포장재 내부의 온도 분포 및 변화 패턴을 관찰한 결과 내용물의 충진 경계인 액위선과 양 모서리 sealing 부위의 온도가 가장 높이 상승하여 hot spot이 형성되는 것을 확인하였고, 이때 온도는 순간적으로 최대 $190^{\circ}C$까지 상승하였다. 반면 내용물의 중심부에서는 온도 상승이 매우 느리게 이루어져 cold spot이 생성되었으며, 700W에서 2분 조리 후 도달 온도는 약 $55^{\circ}C$였다. 특히, 전자레인지 가열 시 내용물의 균일한 가열패턴을 보여주는 hot spot과 cold spot 사이의 온도 상승률은 최대 7,000배까지 차이를 보였다. 따라서 전자레인지 조리 시 내용물의 불균일한 가열로 특정 부위에 열이 집중되는 hot spot의 생성이 포장재 열 변형의 주요 원인으로 판단되었다. 이러한 가열 불균일성은 포장된 내용물에 함유된 당, 염, 수분과 같은 성분들이 점도에 영향을 주는 것에 기인하는 것으로 추측된다. 이러한 점도 변화는 궁극적으로 내용물의 물리적 또는 이온적 특성의 변화를 야기하고, 결과적으로 전자파가 내용물 내부로 침투하는 깊이가 감소되고, 이에 따라 내용물의 유전 특성과 대류 현상에 영향을 주는 것으로 판단된다. 그러나 전자레인지 조리 시 포장재 열 변형 문제의 완전한 해결을 위해서는 향후 포장된 내용물의 세부 성분 별 유전 특성에 대한 보다 세밀한 분석이 필요하며, 아울러 hot spot의 원인이 되는 식품 성분들의 적절한 함량 조절과 함께 포장재, 포장 형태 및 가열 조건 등에 대한 보다 포괄적이고 안정적인 포장시스템 설계와 개발이 필요할 것으로 판단된다.

초단파조사 처리된 잉여슬러지와 하수의 병합처리가 활성슬러지공법의 성능에 미치는 영향 (Effects of the Co-treatment of Municipal Wastewater with Microwave-Irradiated Excess Sludge on the Performance of the Activated Sludge Process)

  • 김남철;장명배;조윤경;조광명
    • 대한환경공학회지
    • /
    • 제29권3호
    • /
    • pp.304-310
    • /
    • 2007
  • 본 연구는 초단파조사 처리된 잉여슬러지를 하수와 함께 활성슬러지공법으로 처리할 때 하수처리효율과 잉여슬러지 발생량에 미치는 영향을 파악하기 위하여 실시되었다. 온도가 $20^{\circ}C$이고 MLSS농도가 약 2,000 mg/L인 250 mL의 잉여슬러지를 발진주파수가 2,450 MHz이고 정격고주파출력이 700 W인 전자렌지(microwave oven)로 초단파조사 처리한 결과 조사시간이 1분 증가함에 따라 수온이 약 $20^{\circ}C$씩 증가하였으며, 슬러지의 SCOD, TKN 및 T-P 농도는 모두 $40\sim130$ sec의 조사시간에서 가장 많이 증가하였다. 그리고 혼합액 미생물의 산소섭취율을 측정한 결과 130 sec 이상의 조사시간($65^{\circ}C$ 이상)에서는 혼합액의 미생물이 거의 사멸하는 것으로 나타났다. 잉여슬러지를 초단파조사 처리한 다음 하수와 혼합시켜 활성슬러지공법으로 처리하였을 때 유입수 및 처리수의 pH 및 알칼리도에는 거의 영향이 없었으나, 유입수의 SS, COD, T-N 및 T-P 농도는 증가하였으며, 처리수의 SS, BOD 및 T-P 농도는 거의 영향을 받지 않았으나 COD 및 TKN 농도는 증가하였다. 그리고 초단파 조사비가 1 g SS/g SS-day 증가할수록 미생물성장계수 값은 0.91 g SS/g COD removed의 율로 감소하였다.

골중납 측정의 시료 전처리 (산분해법과 마이크로웨이브 분해법)와 측정 방법 (유도결합 플라즈마 질량분석법과 흑연로 원자 흡수 분광 광도법)의 비교 (Comparisons of sample preparation (acid digestion and microwave digestion) and measurement (inductively coupled plasma mass spectrometry and graphite furnace atomic absorption spectrometry) in the determination of bone lead)

  • 윤충식;최인자;박성균;김록호
    • 분석과학
    • /
    • 제16권2호
    • /
    • pp.152-158
    • /
    • 2003
  • 본 연구는 인체의 골중 납 농도를 측정하는데 필요한 시료 전처리법과 기기 분석법을 평가하기 위하여 수행되었다. 절단한 인간 사체 다리의 뼈를 상온에서의 산 분해법과 마이크로웨이브 분해법 (microwave oven method)을이용하여 납을 추출하였으며, 유도결합 플라즈마 질량분석법 (ICP-MS)과 흑연로 원자 흡수 분광 광도법 (GF-AAS)으로 납 농도를 측정하였다. 표준시료를 이용하여 회수율을 조사한 결과, 산분해 후 ICP-MS로 측정한 경우 높은 회수율을 보였으나, 산분해 후 GF-AAS로 측정한 것은 표준 농도보다 낮은 값을 보였으며, 마이크로웨이브 분해한 경우는 두 측정기기 모두 표준 농도보다 높은 값을 보였다. 뼈 시료의 경우, 산분해 후 ICP-MS로 측정한 납 농도는 GF-AAS의 값과 높은 상관성을 보였으나 (상관계수 = 0.983), GF-AAS가 ICP-MS보다 계통적으로 높은 값을 측정하였다. 마이크로웨이브 분해 역시 두 분석방법이 높은 상관성을 보였으나 (상관계수 = 0.950), 대체로 산분해에 의한 값보다 높은 농도를 보였다. 결론적으로, 상온에서 질산으로 분해 후 ICP-MS를 이용하여 측정한 것이 골중 납 농도를 결정하는데 편이성과 정확성 면에서 가장 효율적인 방법으로 보인다.

마이크로웨이브 가열에 의한 황비철석의 열분해와 습식-자력선별에 의한 비소 제거 효과 (Thermal Decomposition of Arsenopyrite by Microwave Heating and the Effect of Removal Arsenic with Wet-magnetic separation)

  • 온현성;김현수;명은지;임대학;박천영
    • 한국광물학회지
    • /
    • 제30권3호
    • /
    • pp.103-112
    • /
    • 2017
  • 광액시료와 비-자성광액시료에 포함된 황비철석을 자류철석으로 상변환 시키기 위하여 그리고 비소 함량을 2,000 mg/kg 이하로 제거하기 위하여 마이크로웨이브 장치를 다양한 시간으로 가열하였고, 습식-자력선별하였다. 마이크로웨이브 가열시간이 증가함에 따라 황비철석 표면의 가장자리부터 자류철석으로 상변환이 일어났고, 열점 현상에 의하여 자류철석 내부에 용융공극과 마이크로-크랙들이 형성되었다. 마이크로웨이브 가열을 10분간 수행한 광액시료(비소 함량 : 14,732.66 mg/kg)와 비-자성 광액시료(비소 함량 : 19,970.13 mg/kg)를 습식-자력선별하여 자성광물로 분리시킨 결과, 10분 가열한 자성광물 시료에서 만 비소 함량이 2,000 mg/kg 이하로 나타났다. 따라서 향후 비소 페널티부과 대상인 복합황화광물을 마이크로웨이브 가열과 습식-자력선별을 효과적으로 활용하면, 비소 함량을 페널티 부과대상 이하의 광석광물을 얻을 수 있을 것으로 기대한다.