• Title/Summary/Keyword: microvoid

Search Result 18, Processing Time 0.017 seconds

An Evaluation of the Fracture Behavior for Flash Butt Welding zone by Acoustic Emission Method (AE방법에 의한 Flash Butt 용접부의 파괴거동 평가)

  • 김용수;이하성;강동명
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 1994
  • In this study, we conducted experimental tests to evaluate fracture behaviors of fresh-butt welded metal by Acoustic Emission technique. We selected similar welding and dissimilar welding process, the one welded for SM45C, SS41 and SUS304 of each material, the other for SM45C and SS41, SM45C and SUS304 and SS41 and SUS304. The fracturing processes of weld metal were estimatied through the fracture toughness test with compact tension specimens and fractography analysis. In ASTM test method E-399, type I curves for materials of this study were obtained by load-cod diagram of fracture toughness test. and 5% offset load( $P_{5}$) was estimated as the estimated crack initial load( $P_{Q}$), The estimated crack initial load( $P_{Q}$) of similar welding materials generally lower than base matal, and then SM45C appeared greatly in decreasing rate of PB, SS41 and SUS304 appeared in order. $P_{Q}$ of dissimilar welding materials were lower than the similar welding materials. $P_{Q}$ of welding of SM45C and SS41 appeared in small, SUS304 and SS41 appeared greatly in dissimilar welding materials. In fracture toughness test, AE counts increased before the inflection point of the slope, decreased after that. It was found that increasing of AE counts were due to the microcrack formation at the crack tip near the $P_{5}$ point through AE data. For welding materials in this study, both low and high AE amplitude appeared simulataneously. It was confirmed that the low AE amplotude was due to formation of micro void, micro crack or micro dimple, the high AE amplitude was caused by microvoid coalescence and quasi-cleavage fracture through analyses of fractograpy.apy.apy.apy.

  • PDF

Pretreatment condition Optimization of Hydrolysis and Water Absorption Behavior of PET Fibrous Assembly (전처리 조건에 따른 PET 섬유 집합체의 가수분해 및 흡수성 거동 연구)

  • Lee, Jun-Hee;Lee, Kwang-Woo;Seo, Mal-Yong;Kang, Ji-Man;Kim, Book-Sung
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.88-88
    • /
    • 2012
  • Applied decanol and nonanol provided more weight loss than applied heptanol and octanol. PET using decanol showed the highest weight loss than other alcohols applied. Sodium hydroxide caused weight loss in PET fabrics because terephthalic acid and ethylene glycol were separated by the hydrolysis of the ester group in the PET chains. The terephthalic acid was neutralized to disodium terephthalate and the reaction results in weight loss in the PET fabrics. The weight loss increased with increasing hydrolysis time because disodium terepthalate was water soluble and the reaction was not reached at equilibrium. Pretreatment alcohols increased water absorption, especially in case of PET applied decanol revealed the highest water absorption. PET applied decanol showed 400% of initial water absorption, and PET applied nonanol revealed 250% of initial water absorption. However, the pristine PET showed 90% initial water absorption, and it revealed 230% maximum water absorption as compared to other alcohols. Also, PET applied decanol, nonanol, octanol and heptanol showed 600%, 400%, 350% and 300% maximum water absorption, respectively. The result implied alcohol length affected on water absorption of PET fibrous assembly. This implies that the microvoid of the PET surface hold water molecules. Surface morphology of PET appears that the pretreatment reagent attacks almost entire surface of the fiber, causing surface etching. As the surface etching progresses, it propagates inside the fiber, resulting in the formation of elongated cavities on the surface.

  • PDF

Effect of Heat Treatment on Microstructure and Mechanical Properties of an Fe-6.5Mn-0.08C Medium-Manganese Steel (열처리에 따른 Fe-6.5Mn-0.08C 중망간강의 미세조직과 기계적 특성)

  • Yoon, Young-Chul;Lee, Sang-In;Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • v.30 no.1
    • /
    • pp.8-13
    • /
    • 2020
  • Effect of heat treatment on microstructure and mechanical properties of an Fe-6.5Mn-0.08C medium-manganese steel is investigated in this study. Three kinds of medium-manganese steel specimens are fabricated by varying heat treatments of intermediate quenching (IQ), step quenching (SQ), and intercritical annealing (IA). Hardness and tensile tests are performed to examine the correlation of microstructure and mechanical properties for the Fe-6.5Mn-0.08C medium-manganese steel specimens. The IQ and SQ specimens have microstructures of martensite matrix with ferrite, whereas IA specimen exhibits microstructure of acicular ferrite matrix with martensite. The tensile test results show that the SQ specimen with martensite matrix has the highest yield strength and the lowest elongation. On the other hand, the SQ specimen has the highest hardness due to the relatively lower reduction of carbon content in martensite during intercritical annealing. According to the fractography of tensile tested specimens, the SQ specimen exhibits a dimple and quasi-cleavage fracture appearance while the IQ and IA specimens have fully ductile fracture appearance with fine-sized dimples caused by microvoid coalescence at ferrite and martensite interface.

Influence of Hold Time and Stress Ratio on Cyclic Creep Properties Under Controlled Tension Loading Cycles of Grade 91 Steel

  • Kim, Woo-Gon;Park, Jae-Young;Ekaputra, I Made Wicaksana;Kim, Seon-Jin;Jang, Jinsung
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.581-591
    • /
    • 2017
  • Influences of hold time and stress ratio on cyclic creep properties of Grade 91 steel were systemically investigated using a wide range of cyclic creep tests, which were performed with hold times (HTs) of 1 minute, 3 minutes, 5 minutes, 10 minutes, 20 minutes, and 30 minutes and stress ratios (R) of 0.5, 0.8, 0.85, 0.90, and 0.95 under tension loading cycles at $600^{\circ}C$. Under the influence of HT, the rupture time increased to HT = 5 minutes at R = 0.90 and R = 0.95, but there was no influence at R = 0.50, 0.80, and 0.85. The creep rate was constant regardless of an increase in the HT, except for the case of HT = 5 minutes at R = 0.90 and R = 0.95. Under the influence of stress ratio, the rupture time increased with an increase in the stress ratio, but the creep rate decreased. The cyclic creep led to a reduction in the rupture time and an acceleration in the creep rate compared with the case of monotonic creep. Cyclic creep was found to depend dominantly on the stress ratio rather than on the HT. Fracture surfaces displayed transgranular fractures resulting from microvoid coalescence, and the amount of microvoids increased with an increase in the stress ratio. Enhanced coarsening of the precipitates in the cyclic creep test specimens was found under all conditions.

A Study on Electrolysis of Heavy Water and Interaction of Hydrogen with Lattice Defects in Palladium Electrodes (팔라디움전극에서 중수소의 전기분해와 수소와 격자결함의 반응에 관한 연구)

  • Ko, Won-Il;Yoon, Young-Ku;Park, Yong-Ki
    • Nuclear Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.141-153
    • /
    • 1992
  • Excess tritium analysis was peformed to verify whether or not cold fusion occurs during electrolysis of heavy water in the current density range of 83~600 mA/$\textrm{cm}^2$ for a period of 24 ~ 48 hours with use of palladium electrodes of seven different processing treatments and geometries. The extent of recombination of D$_2$ and $O_2$gases in the electrolytic cell was measured for the calculation of accurate enthaplpy values. The behavior and interaction of hydrogen atoms with defects in Pd electrodes were examined using the Sieverts gas charging and the positron annihilation(PA) method. Slight enrichment of tritium observed was attributed to electrolytic enrichment but not to the formation of a by-product of cold fusion. The extent of recombination of D$_2$and $O_2$gases was 32%. Hence the excess heat measured during the electrolysis was considered to be due to the exothermic reaction of recombination but not to nuclear fusion. Lifetime results from the PA measurements on the Pd electrodes indicated that hydrogen atoms could be trapped at dislocations and vacancies in the electrodes and that dislocations were slightly more preferred sites than vacancies. It was also inferred from R parameters that the formation of hydrides was accompanied by generation of mostly dislocations. Doppler broadening results of the Pd electrodes indicated that lattiec defect sites where positrons were trapped first increased and then decreased, and this cycle was repeated as electrolysis continued. It can be inferred from PA measurements on the cold-rolled Pd and the isochronally annealed Pd hydride specimens that microvoid-type defects existed in the hydrogen-charged electrode specimen.

  • PDF

An Improved Manufacturing Method of p-Dicyclopentadiene (DCPD) using Tungsten Type Catalyst in Air Condition (대기 조건에서 경화가 가능한 텅스텐계 p-DCPD의 개선된 성형 방법)

  • Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Park, Joung-Man
    • Composites Research
    • /
    • v.29 no.4
    • /
    • pp.216-222
    • /
    • 2016
  • Ring-opening metathesis polymerization of p-dicyclopentadiene (DCPD) can be performed using the tungsten type catalyst. This reaction usually progresses in nitrogen condition, because the catalysts are extremely sensitive in air condition. To solve this problem, DCPD resin with tungsten (W) was cured using hot press after stirring of DCPD A and B liquid in air condition. Mechanical properties of DCPD were improved by reducing microvoid occurrence successfully by using hot press method. It might be because hot press could provide sufficient press on DCPD specimen. Addition of catalyst was not effective for the curing of resin in a short time. During polymerization, pressure and temperature had a great influence on the mechanical properties of DCPD.

Improved drop impact reliability of Sn-Ag-Cu solder joint using Cu-Zn solder wetting layer (Cu-Zn 합금 젖음층을 이용한 Sn-Ag-Cu 솔더 접합부의 낙하 충격 신뢰성 향상 연구)

  • Kim, Yeong-Min;Kim, Yeong-Ho
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.35.2-35.2
    • /
    • 2009
  • 최근 본 연구실에서 무연 솔더를 위한 새로운 Cu-Zn 합금 젖음층을 개발하였다. 전해도금을 통하여 Cu-Zn 합금층을 형성한 뒤 그 위에 Sn-4.0wt% Ag-0.5wt% Cu (SAC 405) 솔더를 리플로 솔더링을 통해 솔더접합부를 형성하였으며 계면에서 생성된 금속간 화합물의 형성 및 성장 거동을 연구하였다. SAC/Cu 시스템의 경우, $150^{\circ}C$에서 시효 처리를 실시하는 동안 솔더와 도금된 Cu 계면에서 $Cu_6Sn_5$ 상과 미세한 공공이 형성된 $Cu_3Sn$ 상이 발견되었다. 반면에 SAC/Cu-Zn 시스템에서는 계면에서 $Cu_6Sn_5$ 상만이 형성되었다. 또한 큰 판상형의 $Ag_3Sn$ 상이 SAC/Cu 시스템에 비해 현저하게 억제되었다. SAC/Cu-Zn 계면에서의 금속간 화합물의 성장 속도가 SAC/Cu 계면에서 형성된 금속간 화합물의 성장 속도보다 느리게 나타났다. Cu-Zn 젖음층의 Zn가 솔더와 Cu-Zn 층 사이에서 Cu와 Sn 원자의 상호 확산을 방해하기 때문이다. 본 연구에서는 Cu와 Cu-Zn 층을 이용한 솔더 접합부의 낙하 충격 신뢰성을 연구하였다. 낙하 충격 시험 시편은 두 개의 인쇄 회로 기판을 SAC 405 솔더볼을 이용하여 리플로를 통해 상호연결 하여 제조되었다. 이 때, 각각의 인쇄 회로 기판의 패드에는 Cu 층과 Cu-Zn층을 전해도금을 통하여 각각 $10{\mu}m$두께의 젖음층을 형성하였다. 낙하 시험 시편을 제조한 뒤, 시효 처리에 대한 낙하 저항 신뢰성의 특성을 연구하기 위해 250, 500 시간동안 시효처리를 한 후 각 조건에서 계면에 형성된 금속간 화합물의 성장 거동을 관찰하였으며, 낙하 충격 시험을 실시하였다. 낙하 시험은 daisy chain으로 연결된 시편의 저항이 100 Ohm 이상 측정되었을 때 중단되도록 하였다. Cu-Zn/SAC/Cu-Zn 시편의 경우 초기 리플로를 하였을 때 불량이 발생하는 평균 낙하 수는 350이며, Cu/SAC/Cu 시편의 평균 낙하수는 200 미만으로 나타났다. Cu/SAC/Cu 시편의 경우, 시효처리 시간이 증가함에 따라 평균 낙하수는 큰 폭으로 감소하였지만, Cu-Zn/SAC/Cu-Zn 시편은 불량이 발생하는 평균 낙하수의 감소폭이 보다 완만하게 나타났다. Cu 층에 Zn를 첨가함으로써 솔더와 젖음층 사이에서 형성된 금속간 화합물의 성장 및 미세 공공의 형성이 억제되었고, 솔더 접합부의 과냉을 감소시킴으로써 큰 판상형의 $Ag_3Sn$ 상의 형성을 억제함으로써 Cu-Zn/SAC/Cu-Zn 솔더 접합부에서 Cu/SAC/Cu 솔더 접합부보다 낙하 충격에 대한 저항성 및 신뢰성이 향상되었다. 이는 무연 솔더에 Zn를 첨가하여 낙하 충격 신뢰성을 향상시킨 것과 동일한 효과를 나타냈음을 확인하였다. 본 연구는 한국 과학 기술 재단의 전자패키지 재료 연구 센터(CEPM)와 지식 경제부의 부품 소재 기술 개발 사업의 지원을 받아 수행되었습니다.

  • PDF

The Effect of Surface Defects on the Cyclic Fatigue Fracture of HEROShaper Ni-Ti rotary files in a Dynamic Model: A Fractographic Analysis (Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할)

  • Lee, Jung-Kyu;Kim, Eui-Sung;Kang, Myoung-Whai;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • This in vitro study examined the effect of surface defects on cutting blades on the extent of the cyclic fatigue fracture of HEROShaper Ni-Ti rotary files using fractographic analysis of the fractured surfaces. A total of 45 HEROShaper (MicroMega) Ni-Ti rotary flies with a #30/.04 taper were divided into three groups of 15 each. Group 1 contained new HEROShapers without any surface defects. Group 2 contained HEROShapers with manufacturing defects such as metal rollover and machining marks. Croup 3 contained HEROShapers that had been clinically used for the canal preparation of 4-6 molars A fatigue-testing device was designed to allow cyclic tension and compressive stress on the tip of the instrument whilst maintaining similar conditions to those experienced in a clinic. The level of fatigue fracture time was measured using a computer connected the system. Statistical analysis was performed using a Tukey's test. Scanning electron microscopy (SEM) was used for fractographic analysis of the fractured surfaces. The fatigue fracture time between groups 1 and 2, and between groups 1 and 3 was significantly different (p<0.05) but there was no significant difference between groups 2 and 3 (p>0.05). A low magnification SEM views show brittle fracture as the main initial failure mode At higher magnification, the brittle fracture region showed clusters of fatigue striations and a large number of secondary cracks. These fractures typically led to a central region of catastrophic ductile failure. Qualitatively, the ductile fracture region was characterized by the formation of microvoids and dimpling. The fractured surfaces of the HEROShapers in groups 2 and 3 were always associated with pre-existing surface defects. Typically, the fractured surface in the brittle fracture region showed evidence of cleavage (transgranular) facets across the grains, as well as intergranular facets along the grain boundaries. These results show that surface defects on cutting blades of Ni-Ti rotary files might be the preferred sites for the origin of fatigue fracture under experimental conditions. Furthermore this work demonstrates the utility of fractography in evaluating the failure of Ni-Ti rotary flies.