• 제목/요약/키워드: microstructural change

검색결과 316건 처리시간 0.021초

SM40C 강의 열처리가 피로균열전파속도에 미치는 영향 (The Effect of Heat Treatment on the Fatigue Crack Propagation in SM40C Steel)

  • 금창훈;권숙인
    • 열처리공학회지
    • /
    • 제3권2호
    • /
    • pp.37-44
    • /
    • 1990
  • The effect of the microstructural change on the near threshold fatigue crack growth rate in SM40C steel has been studied using the ${\Delta}K$ decreasing method. Below the total strain amplitude of 0.56%, cyclic softening occured, whereas above this value cyclic hardening occurred in the pearlitic lamellar structure. However, in the spherodized structure the cyclic hardening solely occurred. The crack growth rate in the near-threshold region was decreased with increasing prior austenite grain size and this was due to surface roughness. The crack growth rate of the spherodized structure was lower than that of the pearlite lamellar structure and the ${\Delta}K_{th}$ of the former was higher than that of the latter. It was understood that the crack propagates preferentially through the ferrite phase. The intergranular facets in the near-threshold region appeared in the spherodized structure.

  • PDF

도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구 (The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal)

  • 김희진;김부섭
    • 대한치과기공학회지
    • /
    • 제32권3호
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

청산화강암의 압쇄암화작용 동안에 미구조 변화 (The Micostructural Change During the Mylonitzation of Cheongsan Granite, Korea)

  • 강지훈
    • 암석학회지
    • /
    • 제24권2호
    • /
    • pp.125-139
    • /
    • 2015
  • 거정 장석반정을 다량 함유하는 청산화강암이 연성전단변형을 받아 압쇄암화되는 동안에 일어난 미구조 변화를 파악하기 위해 변형된 청산화강암의 암석구조와 미구조 연구를 수행하였다. K-장석에서 특징적인 미구조는 미세킹크, 미세단열, 밀메카이트, 플레임 퍼어사이트, 코아 외부에 아입자 발달이 없는 코아-맨틀구조 등으로 인지된다. 미세킹크는 미세 단열되거나 미단열된 K-장석들에서 모두 관찰되고, 미세킹크의 축 방향은 미세단열에 의해 경계져 있는 양쪽 K-장석으로 연장된다. 밀메카이트와 플레임 퍼어사이트는 미세 단열된 K-장석들의 입계에 고 변형량의 집중으로 발달한다. 사장석에는 미세단열, 변형쌍정, 킹크대 등이 우세하게 관찰된다. 거정 사장석 반정의 입도 세립화는 역시 미세단열작용에 의해 진행되었다. 그러나 미세 단열된 K-장석과 달리 미세 단열된 사장석에는 코아-맨틀구조가 관찰되지 않는다. 화성기원의 누대구조를 중첩하는 변형쌍정은 변형정도가 낮은 저 변형암에서 종종 관찰된다. 고 변형암에서 변형쌍정의 엽층들은 일반적으로 공액성 킹크대의 둔각 이등분선 방향으로 발달하고, 미세단열 내지 미세단층 되어 무질서한 배열을 보인다. 따라서 이와 같은 특징적인 미구조로부터 청산화강암의 압쇄암화작용 동안에 미구조는 다음과 같이 발달하였음을 제시한다: 거정 K-장석 반정에 미세킹크의 출현과 사장석에 킹크대와 변형쌍정의 출현, 미세단열작용에 의한 거정 장석반정들의 입도 세립화, 미세 단열된 K-장석에 밀메카이트와 플레임 퍼어사이트 그리고 입계이동 재결정작용에 의한 K-장석 조각들의 입도 세립화와 함께 코아-맨틀구조의 출현.

입력기체비를 이용한 미세구조 변화로부터 화학증착 탄화규소의 복층구조 제작 (Fabrication of CVD SiC Double Layer Structure from the Microstructural Change Through Input Gas Ratio)

  • 오정환;왕채현;최두진;송휴섭
    • 한국세라믹학회지
    • /
    • 제36권9호
    • /
    • pp.937-945
    • /
    • 1999
  • 반응결합 탄화규소(RBSC) 반응관을 보호하기 위하여, 반응결합 탄화규소 기판 위에 탄화규소를 1~10 범위의 입력기체비(${\alpha}=P_{H2}/P_{MTS}=Q_{H2}/Q_{MTS}$)와 1050~1300$^{\circ}C$범위의 증착온도에서 methyltrichlorosilane(MTS)로부터 수소분위기에서 저압화학기상법으로 증착하였다. 1250$^{\circ}C$의 증착온도에서 입력기체비가 감소함에 따라 증착속도는 증가하다가 감소하였다 입력기체비가 높을 때에는 (111) 우선배향성을 나타내고 과립형의 미세구조를 보이며, 입력기체비가 작을 경우에는 (220) 우선배향성을 가지는 마면주상의 미세구조가 관찰되었다. 증착온도가 증가함에 따라 입력기체비와 비슷하게 미세구조의 변화하는결과를 얻었으며, 이러한 결과는 증착기구의 변화와 밀접한 관련이 있다. 일정한 증착온도에서 입력기체비의 조정를 통하여 얻었으며, 이러한 결과는 증착기구의 변화와 밀접한 관련이 있다. 일정한 증착온도에서 입력기체비의 조절을 통하여 과립형과 미면주상의 미세구조를 함께 가지는 복층구조를 연속공정을 통하여 성공적으로 제조하였다.

  • PDF

열처리 조건에 따른 Ag-In-Sb-Te 상변화 기록 박막의 미세 조직과 반사도의 관계 (Dependence of Microstructure and Optical Properties of Ag-In-Sb-Te Phase-Change Recording Thin Firms on Annealing Heat-Treatments)

  • 서훈;박정우;최우석;김명룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.9-14
    • /
    • 1996
  • The dependence of microstructural and optical properties of Ag-In-Sb-Te thin films on annealing heat-treatments was studied. It was found from the present work that the increase of reflectance after annealing heat-treatment is related with phase change of Ag-In-Sb-Te thin film from amorphous state to crystalline phases which involve Sb crystalline phase and AgInTe$_2$ stoichiometric phase. On the other hand, the reflectance is decreased after high temperature annealing (above 450$^{\circ}C$), due to the morphology .mange of film surface. For the purpose of practical application(erasable optical disk), we fabricated quadrilayered Ag-In-Sb-Te alloy disk, and annealed it with continuous laser beam. As result of this laser\ulcorner annealing treatment, we found that the increment of reflectance is 9.3% at 780nm wavelength. It might be considered that Ag-In-Sb-Te alloy optical disk is the big promising candidate for the erasable optical memory medium.

  • PDF

Nitrogen Permeation Treatment of Duplex and Austenitic Stainless Steels

  • Yoo, D.K.;Joo, D.W.;Kim, Insoo;Kang, C.Y.;Sung, J.H.
    • 열처리공학회지
    • /
    • 제15권2호
    • /
    • pp.57-64
    • /
    • 2002
  • The 22%Cr-5%Ni-3%Mo duplex and 18%Cr-8%Ni austenitic stainless steels have been nitrogen permeated under the $1Kg/cm^2$ nitrogen gas atmosphere at the temperature range of $1050^{\circ}C{\sim}1150^{\circ}C$. The nitrogen-permeated duplex and austenitic stainless steels showed the gradual decrease in hardness with increasing depth below surface. The duplex stainless steel showed nitrogen pearlite at the outmost surface and austenite single phase in the center after nitrogen permeation treatment, while the obvious microstructural change was not observed for the nitrogen-permeated austenitic stainless steel. After solution annealing the nitrogen-permeated stainless steels(NPSA treatment) at $1200^{\circ}C$ for 10 hours, the hardness of the duplex and austenitic stainless steels was constant through the 2 mm thickness of the specimen, and the ${\alpha}+{\gamma}$ phase of duplex stainless steel changed to austenite single phase. Tensile strengths and elongations of the NPSA-treated duplex stainless steel remarkably increased compared to those of solution annealed (SA) duplex stainless steel due to the solution strengthening effect of nitrogen and the phase change from a mixture of ferrite and austenite to austenite single phase, while the NP-treated austenitic stainless steel displayed the lowest value in elongation due to inhomogeneous deformation by the hardness difference between surface and interior.

Microstructure and Mechanical Property of Irradiated Zr-2.5Nb Pressure Tube in Wolsong Unit-1

  • 김영숙;안상복;오동준;김성수;정용무
    • 소성∙가공
    • /
    • 제8권3호
    • /
    • pp.241-241
    • /
    • 1999
  • With the aim of assessing the degradation of Zr-2.5Nb pressure tubes operating in the Wolsong unit-1 nuclear power plant, characterization tests are being conducted on irradiated Zr-2.5Nb tubes removed after 10-year operation. The examined tube had been exposed to temperatures ranging from 264 to 306℃ and a neutron fluence of 8.9×$10^{21}$ n/cm²(E>1 MeV) at the maximum. Tensile tests were carried out at temperatures ranging from RT to 300℃. The density of a-type and c-type dislocations was examined on the irradiated Zr-2.5Nb tube using a transmission electron microscope. Neutron irradiation up to 8.9×$10^{21}$ n/cm²(E>1 MeV) yielded an increase in a-type dislocation density of the Zr-2.5Nb pressure tube to 7.5×$10^{14} m^{-2}$, which was highest at the inlet of the tube exposed to the low temperature of 275℃. In contrast, the c-component dislocation density did not change with irradiation, keeping an initial dislocation density of 0.8×$10^{14} m^{-2}$ over the whole length of the tube. As expected, the neutron irradiation increased mechanical strength by about 17-26% in the transverse direction and by 34-39% in the longitudinal direction compared to that of the unirradiated tube at 300℃. The change in the mechanical properties with irradiation is discussed in association with the microstructural change as a function of temperature and neutron fluence.

Iron Aluminide-$SiC_p$ 혼합 예비성형체를 사용한 Al합금기 복합재료의 내마모 특성 (Wear Resistance of Al Alloy Matrix Composites Using Porous Iron Aluminide-$SiC_p$ Preforms)

  • 차재상;오선훈;최답천
    • 한국주조공학회지
    • /
    • 제23권1호
    • /
    • pp.30-39
    • /
    • 2003
  • Porous hybrid preforms were fabricated by reactive sintering using the compacts consisting of SiC particles, Fe and Al powders. Squeeze casting processing was employed to produce the composite in which the matrix phase is Al-Si7Mg. The microstructural change and wear resistance of the composites were investigated in terms of an amount of SiC particles. The wear loss was increased with increasing the contact pressure in the alloy containing SiC particles coated with Cu. The most drastic change was found to the specimen tested at 2.5 MPa of contact pressure. Concerning the alloys containing SiC particles coated with Ni-P, a drastic increase in the wear loss exhibited at 2 MPa of contact pressure in those alloys containing 4 and 8 wt. % of SiC particles coated with Ni-P. In the alloy containing 16 wt. % a proportional increase in wear loss was observed to the change of contact pressure. With respecting to the sliding velocity, the wear loss of the alloy containing SiC particles coated with Cu increased at the initial stage of wear process and then decreased. Similar result was found in the alloys containing SiC particles coated with Ni-P. On the basis of the present results obtained, it was found that wear resistance of the alloys tested was improved to show in the order of the alloy reinforced by coated SiC particles > by uncoated SiC particles > by intermetallic compound without SiC particles.

시멘트 클링커 원료로서 적용한 석탄재의 고온 미세구조 변화 고찰 (A Study on Changes in High-Temperature Microstructure of Coal Ash Applied as Cement Clinker Raw Material)

  • 유동우;임영진;권성구;이석제
    • 한국건설순환자원학회논문집
    • /
    • 제10권3호
    • /
    • pp.211-218
    • /
    • 2022
  • 석탄재는 시멘트 클링커의 실리카와 알루미나질 공급원으로서 활용이 고려되고 있다. 이러한 석탄재의 시멘트 클링커 소성과정에서 소성온도에 따른 고온 미세구조변화를 검토하여, 시멘트 클링커 소성에서 미치는 영향을 파악하고자 하였다. 시멘트 클링커의 원료로서 사용된 석탄재는 소성온도 950 ℃부터 입자 표면의 형상변화가 관찰되었으며, 1250 ℃ 이상의 소성온도에서 부터는 석탄재의 형상이 소멸되었다. 석탄재의 Al, Fe 성분은 1350 ℃ 이상의 온도에서는 시멘트 간극상으로 전환되는 되는 것을 확인하였다. 또한, 다량의 석탄재를 원료로 적용한 클링커는 1150~1200 ℃의 소성온도 구간에서 Lime의 함량이 낮고, Belite의 함량이 높게 나타나, 석탄재의 적용으로 초기 소성온도에서 칼슘실리케트 광물의 형성이 더 원활하게 진행되는 것을 확인하였다.

연속주조한 구상흑연주철의 미세조직과 기계적 성질 (Microstructure and Mechanical Properties of Continuous Cast Ductile Iron)

  • 최경환;조규섭;이경환;김기영
    • 한국주조공학회지
    • /
    • 제24권1호
    • /
    • pp.52-59
    • /
    • 2004
  • Microstructure and mechanical properties of ductile cast iron were investigated in terms of diameter change of samples that gives rise to modify the microstructure due to different cooling rate in the continuous casting process. The chemical composition used in this study was GCD 400 grade. From the microstructural observation, we have found a large number of graphite with small size in diameter which is comparable to the microstructure of the sample produced by conventional sand casting. The major reason of this would he due to high cooling rate. In the sample with 26 mm in diameter, the microstructure was composed of pearlite, iron carbide, and graphite. In the samples with 60 and 100 mm in diameter, however, we have observed a dissimilar microstructure that consisting of ferrite and graphite. Concerning the mechanical property, the sample with 26 mm in diameter showed higher hardness and strength compared to those samples with 60 and 100 mm in diameter. The result obtained for ductility appeared a reversal. Much more works such as inoculation, process design and chemical composition would be required in order to have a sound product even in a small diameter of samples.