• Title/Summary/Keyword: microscopic system

Search Result 539, Processing Time 0.027 seconds

A Case of Microscopic Polyangiitis with Diffuse Alveolar Hemorrhage (폐출혈을 동반한 현미경적 다발혈관염 1예)

  • Lee, Sang-Jin;Lee, Jae-Woung;Kim, Hye-Jin;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho;Park, Hye-Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.1
    • /
    • pp.101-107
    • /
    • 2004
  • Diffuse alveolar hemorrhage is a rare but serious and frequently life-threatening complication of a variety of conditions. The first goal in the management of patients with diffuse alveolar hemorrhage is to achieve or preserve stability of the respiratory status. Subsequently, the differential diagnosis is aimed at the identification of a remediable cause of the alveolar hemorrhage. The most common causes of diffuse alveolar hemorrhage with glomerulonephritis are microscopic polyangiitis and Wegener's granulomatosis, followed by Goodpasture syndrome and systemic lupus erythematosus. Microscopic polyangiitis (MPA) is a distinct systemic small vessle vasculitis affecting small sized vessels with few or no immune deposits and with no granulomatosus inflammation. The disease may involve multiple organs such as kidney, lung, skin, joint, muscle, gastrointestinal tract, eye, and nervous system. MPA is strongly associated with antineutrophil cytoplasmic autoantibody (ANCA) that is a useful serological diagnostic marker for the most common form of necrotizing vasculitis. Our report concerns a case of microscopic polyangiitis with diffuse alveolar hemorrhage in a 54-year-old man. He was admitted to our hospital due to dyspnea upon exertion and recurrent hemoptysis. Laboratory findings showed hematuria, proteinuria and deterioration of renal function. In the chest CT scan, diffuse ground glass appearance was seen in both lower lungs. A lung biopsy revealed small vessel vasculitis with intraalveolar hemorrhage and showed a positive reaction to against perinuclear ANCA. The patient was treated with prednisolone and cyclophosphamide. Chest infiltration decreased and hemoptysis and hypoxia improved. He is still being followed up in our hospital with a low dose of prednisolone.

  • PDF

THE ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE OF VARIOUS DENIAL MAGNETIC ATTACHMENTS (수종 치과용 자석유지장치의 부식저항성에 대한 전기화학적 연구)

  • Sohn Byoung-Sup;Chang Ik-Tae;Heo Seong-Joo;Keak Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.336-350
    • /
    • 2001
  • The purpose of this study was to investigate corrosion tendency and to compare corrosion resistance of three dental magnetic attachments and its keeper alloy by coercive, electrochemical method. By using petentiodynamic polarization technique, magnetic elements and its keeper alloy of Magfit EX600 system(MF, MFK), Dyna ES regular system(DN, DNK) and Shiner SR magnet system(SR, SRK) were corroded electrochemically in 0.9% NaCl electrolytic solution. Open-circuit potential and anodic polarization curve was measured with Potentiostat(model 273 EG&E) and polarization curve was created by current density per square area following scanning of increased series of voltage in the rate of 1.0mV per second. Before and after electrochemical corrosion, the surface roughness test was done. Thereafter the change of mean surface roughness value(Ra) and mean peak value(Rt) of surface roughness was compared one another. In order to observe the corroded surface of each specimen, metallurgical light microscopic(${\times}37.5$) and scanning electron microscopic view(SEM ${\times}100$) was taken and compared one another. Conclusion is followings. 1. All of six covering metal of dental magnetic attachments and its keeper alloy were corroded in various degree after electrochemical corrosion. 2. The corrosion resistance of which used in this experiment is the following in high order; DNK, MFK, DN, MF, SRK and SR. 3. Especially Shiner magnet system and its keeper alloy were more severely corroded after electrochemical corrosion and the change of Ra Rt value were more increased than others. 4 Metallurgical and scanning electron microscopic view showed the pitting corrosion tendency of all experimental alloy but DNK and SR. 5. Covering metal of magnet was more corroded than its keeper alloy.

  • PDF

Ultrasonic flushing 기법에 의한 유류오염토양의 복원에 관한 실험연구

  • Jeong, Ha-Ik;Oh, In-Gyu;Kim, Sang-Geun;Lee, Yong-Su;Yoo, Jun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.13-17
    • /
    • 2002
  • Ultrasonic waves have several mechanical, chemical, and biological effects on a saturated soil medium. Their mechanical effects, popularly known as cavitation. Cavitation is the rapid and repeated formation, and resulting implosion, of imcrobubbles in a liquid, resulting in the propagation of microscopic shock waves. In a soil-liquid system, their mechanical effects generate high differntial fluid-particle velocities and microscopic shock waves. The velocity perturbations are capable of dislodging oil in the system by overcoming the forces binding oil to sand particles. In this study, a series of laboratory experiments involving the simple flushing and ultrasonic flushing were carried out. An increase in permeability and oil removal rate were observed in ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of ultrasonics.

  • PDF

Computer Vision System for Analysis of Geometrical Characteristics of Agricultural Products and Microscopic Particles(II) -Algorithms for Geometrical Feature Analysis- (농산물 및 미립자의 기하학적 특성 분석을 위한 컴퓨터 시각 시스템(II) -기하학적 특성 분석 알고리즘-)

  • Lee, J.W.;Noh, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.2
    • /
    • pp.143-155
    • /
    • 1992
  • The aim of this study is to develop a general purpose algorithm for analyzing geometrical features of agricultural products and microscopic particles regardless of their numbers, shapes and positions with a computer vision system. Primarily, boundary informations of an image were obtained by Scan Line Coding and Scan & Chain Coding methods and then with these informations, geometrical features such as area, perimeter, lengths, widths, centroid, major and minor axes, equivalent circle diameter, number of individual objects, etc, were analyzed. The algorithms developed in this study was evaluated with test images consisting of a number of randomly generated ellipsoids or a few synthesized diagrams having different features. The result was successful in terms of accuracy.

  • PDF

Study on the Estimation of Macroscopic Outage Cost using Reduction of Regional Added Value due to Power Outage (정전에 따른 지역 및 산업종별 부가가치 저감을 고려한 거시적 관점에서의 지역별 공급지장비 단가 산정에 관한 연구)

  • Lee, Jae-Gul;Choy, Young-Do;Jeon, Dong-Hoon;Seo, Chul-Soo;Choi, Jae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.726-732
    • /
    • 2011
  • To establish the transmission system expansion plan based on reliability, valuation of outage cost become more important. In previous studies about outage cost estimation, macroscopic, microscopic and analytic methods are proposed but they have some limit. For instance, microscopic method involves a complex field survey process and macroscopic method can not estimate regional outage cost. So in this paper, a new method to estimate regional macroscopic outage cost using the reduction of value added due to power outages is proposed. This method uses regional add value according to production activities called Gross Regional Domestic Product(GRDP) and regional electricity sales.

Remote Access and Data Acquisition System for High Voltage Electron Microscopy (초고전압 투과전자현미경의 원격제어 및 데이터 획득 시스템)

  • Ahn, Young-Heon;Kang, Ji-Seoun;Jung, Hyun-Joon;Kim, Hyeong-Seog;Jung, Hyung-Soo;Han, Hyuck;Jeong, Jong-Man;Gu, Jung-Eok;Lee, Sang-Dong;Lee, Jy-Soo;Cho, Kum-Won;Kim, Youn-Joong;Yeom, Heon-Young
    • Applied Microscopy
    • /
    • v.36 no.1
    • /
    • pp.7-16
    • /
    • 2006
  • A new remote access system for a 1.3 MV high voltage electron microscope has been developed. Almost all essential functions for HVEM operation, huck as stage control, specimen tilting, TV camera selection and image recording, are successfully embedded into this prototype of the remote system. Particularly, this system permits perfect and precise operation of the goniometer and also controls the high resolution digital camera via simple Web browsers. Transmission of control signals and communication with the microscope is accomplished via the global ring network for advanced applications development (GLORIAD). This fact makes it possible to realize virtual laboratory to carry out practical national and international HVEM collaboration by using the present system

Development of a general purpose molecular simulation system from microscopic to mesoscopic scales (미시영역에서 중간역역까지 적용 가능한 범용 분자 시뮬레이션 시스템의 개발)

  • Oh, Kwang-Jin
    • The KIPS Transactions:PartD
    • /
    • v.12D no.6 s.102
    • /
    • pp.921-930
    • /
    • 2005
  • In this paper, a general purpose molecular simulation system which has been developed by the author, are described. One of the most advantageous features is that the molecular simulation system can handle a coarse-grained model as well as an all-atom mode. Therefore, we can simulate mesoscopic phenomena as well as microscopic phenomena with the help of Langevin dynamics simulation and dissipative particle dynamics simulation techniques. Thus we could study anesthesia, protein folding, biopolymer flow in microchannel with single framework, which spans from microscopic to mesoscopic scales. We expect that we can also simulate many other bio/nano systems of technological importance which are not feasible by means of molecular dynamics simulation technique. Finally, performance data are shown and a bottleneck is identified for future optimization.