• Title/Summary/Keyword: microcomputer control system

Search Result 167, Processing Time 0.026 seconds

Microcomputer-aided design for a digital control system (디지탈 제어시스템을 위한 마이크로컴퓨터 지원설계)

  • 주해호;조덕현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.282-287
    • /
    • 1987
  • This paper presents the development of a microcomputer-aided design program for a digital control system. The program has been written in GWBASIC language which is suitable for Intel 8086II CPU with 640KB memory. By utilizing this program, sampling time, the number of bits A/D and D/A converter, and the stability for the digital control system carl be determined, To demonstrate the utility of this program, a microcomputer controlled precision temperature control system has been employed as an example.

  • PDF

Microcomputer-Aided Design For a SISO Control System (SISO 제어시스템을 위한 마이크로 컴퓨터 지원설계)

  • Joo, Hae-Ho;Cho, Deok-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.5 no.3
    • /
    • pp.63-70
    • /
    • 1988
  • This paper presents the development of a microcomputer-aided design program for a SISO control system. The program has been written in GWBASIC language which is suitable for Intel 80861 CPU with 640KB memory. By utilizing this program, sampling time, the number of bits for the A/D and D/A converter, and the stability for the digital control system can be determined. To demonstrate the utility of this program, a microcomputer controlled precision temperature control system has been employed as an example.

  • PDF

Control of Elevator System Model Using Microcomputer (Microcomputer를 이용한 엘리베이터 시스템 모델의 제어)

  • 송현빈;변증남
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.16 no.2
    • /
    • pp.35-42
    • /
    • 1979
  • A conventional elevator system, which requires simultaneous control of the speed and the position, contains complicated analog hardwares as the control system. Recent advances in LSI technology, however, suggest that the control of such ane levator system may be realized by Incorporating digital device and microcomputer. In this paper, such a possibility is investigated. In this paper, the digital controller, witch is implemented around an IMSAl 8080 microcomputer is designed for the control of model elevator system. Experiments show that this contra .system tracks the given velocity curve as well as it brings the elevator to the enact point.

  • PDF

Development of Automatic Nutrient-Solution Controller Using Single-chip Microcomputer (원칩 마이크로 컴퓨터를 이용한 양액 자동 조제 장치의 개발)

  • 오길근;류관희;홍순호;김효중
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.383-389
    • /
    • 1995
  • This study was conducted to develop an automatic nutrient control system for trickle application of nutrient solution. Temperature, electric conductivity(EC). pH and dissolved oxygen(DO) were selected as control variables. A controller using single-chip microcomputer was constructed. An automatic control system for nutrient solution and a controller using single-chip microcomputer with control algorithm were developed. The control system was tested, and could control temperature, EC and pH within the error ranges of $pm 0.2^{circ} pm 0.2mS/cm, pm 0.1pH$, respectively.

  • PDF

A Microcomputer-Based Control System for Green House (I) -Water Management- (시설원예(施設園藝)에 있어서 재배관리(栽培管理)의 자동화(自動化) 시스템에 관(關)한 연구(硏究) (I) -물관리 자동화(自動化)-)

  • Lee, K.M.;Park, K.S.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.1
    • /
    • pp.31-36
    • /
    • 1986
  • As a part of study on automatic control system for green houses, an automatic irrigation system was developed by using microcomputer. For the study, gypsum block was used as a sensing device of soil moisture and its data was designed to transfer to microcomputer through A/D converter. Also, software which be able to control the irrigation time and flow rate by the solenoid valve was developed. This system was tested by using practical data and the following results were summarized. 1. Since the gypsum was very accurate in addition with chiep and easy to manufacture, it turned out to be a very good device to detect the soil moisture in this system. 2. Also, solenoid valve was very excellent device for controlling the water flow rate since its control error is less then 1% when the irrigation time is over 100 seconds.

  • PDF

Design of a microprocessor control system for an one-through tube boiler using RTE (RTE(Real Time Executive)를 이용한 수관식 관류 보일러 제어 시스템의 설계)

  • 김정호;한동원;조삼현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.225-231
    • /
    • 1986
  • A design of an industrial microcomputer control system for an one-through tube boiler using oil is presented. The microcomputer system is based on standard iSBC 88/40 board. The software consist of a RTE(real time executive) and application tasks. The designed control system saves fuel and gives a more reliable over-all operation.

  • PDF

Microcomputer에 의한 3상유도전동기의 속도제어에 관한 연구

  • 정연택;이사영
    • 전기의세계
    • /
    • v.31 no.4
    • /
    • pp.303-307
    • /
    • 1982
  • This paper describes how to improve a induction moter efficiency by a slip frequency control. Digital filter controlled by microcomputer is introduced in control system of a constant speed-drive and it has prove that the moter can be drived with a high efficiency at a constant slip frequency. The constant slip frequency control method has a merit of simplness.

  • PDF

The Triple Current Source Inverter System for Induction Motor Drive Using a One Chip Microcomputer (One Chip Microcomputer를 이용한 유도전동기 구동용 3동 전류형 인버어터시스템)

  • Chung, Yon-Tack;Jang, Seong-Chil;Hwang, Lak-Hoon;Lee, Hoon-Goo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.2
    • /
    • pp.162-172
    • /
    • 1991
  • In proportion to the capacity enlargement of the induction motor system controlled by current source inverter, the capacitance of the commutating capacitor is enlarged and then the spike value of output voltage is increased at the moment of charge and discharge. Moreover, the output currnet includes a number of harmonic components. Such voltage spike and harmonics generate the torque ripple and lead to bad effects on the performance of the induction motor. In this study, all the harmonics excluding 17th and 19th harmonics were mostly elimunated by adopting 18-phase Triple High Frequency Current Source Inverter(HFCSI), and the spike component of output voltage was reduced by adding the Voltage Clamping Circuit(VCC). As a result, the torque ripple and the commutation loss were reduced and the performance of the system was improved. Experiments for speed control were carried out in the tripple current source inverter system for induction motor drive. Overall system was controlled by ONE CHIP MICROCOMPUTER(INTEL 8751). Control circuits were simplified and good experimental results in the constant V/F control were obtained due to the flexibility of the microcomputer.

  • PDF

A Study on the Microcomputer Based Infusion Pump (의료용 Infusion Pump 개발에 관한 연구)

  • 이경중;이윤선
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.63-68
    • /
    • 1984
  • The Infusion pump that is widely used in hospital has been designed. This system consists of microcomputer system, stepping motor control part and mechanical part for syringe driving. It has 450mmHg maximum pressure and $\pm$0.5% accuracy, and and especially keep the accent on the electrical and functional safety.

  • PDF

Operation of microcomputer aided convective drying system (마이크로컴퓨터 제어 열풍건조장치의 제작운영)

  • Jeong, Sin-Gyo;Gang, Jun-Su;Choe, Jong-Uk
    • Food Science and Preservation
    • /
    • v.1 no.2
    • /
    • pp.99-105
    • /
    • 1994
  • To convert the analog signal from the drying process into the digital signal, the interface circuit was designed and built. To measure the weight and temperature during drying process, strain gauge type load cell and temperature transducer composed of pt 100 $\Omega$ thermometers and wheatstone bridge circuits were built and used. The temperature control device was composed of photocoupler and triac. Microcomputer aided experimental convective drying system was built with above cricuits and devices. Drying characteristics of onions can be estimated using this system.

  • PDF