• 제목/요약/키워드: micro-droplet cell

검색결과 17건 처리시간 0.022초

Micro to Nano-scale Electrohydrodynamic Nano-Inkjet Printing for Printed Electronics: Fundamentals and Solar Cell Applications

  • 변도영
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.3.2-3.2
    • /
    • 2011
  • In recent years, inkjet printing technology has received significant attention as a micro/nanofabrication technique for flexible printing of electronic circuits and solar cells, as well for biomaterial patterning. It eliminates the need for physical masks, causes fewer environment problems, lowers fabrication costs, and offers good layer-to-layer registration. To fulfill the requirements for use in the above applications, however, the inkjet system must meet certain criteria such as high frequency jetting, uniform droplet size, high density nozzle array, etc. Existing inkjet devices are either based on thermal bubbles or piezoelectric pumping; they have several drawbacks for flexible printing. For instance, thermal bubble jetting has limitations in terms of size and density of the nozzle array as well as the ejection frequency. Piezoelectric based devices suffer from poor pumping energy in addition to inadequate ejection frequency. Recently, an electrohydrodynamic (EHD) printing technique has been suggested and proposed as an alternative to thermal bubble or piezoelectric devices. In EHD jetting, a liquid (ink) is pumped through a nozzle and a strong electric field is applied between the nozzle and an extractor plate, which induce charges at the surfaces of the liquid meniscus. This electric field creates an electric stress that stretches the meniscus in the direction of the electric field. Once the electric field force is larger than the surface tension force, a liquid droplet is formed. An EHD inkjet head can produce droplets smaller than the size of the nozzle that produce them. Furthermore, the EHD nano-inkjet can eject high viscosity liquid through the nozzle forming tiny structures. These unique features distinguish EHD printing from conventional methods for sub-micron resolution printing. In this presentation, I will introduce the recent research results regarding the EHD nano-inkjet and the printing system, which has been applied to solar cell or thin film transistor applications.

  • PDF

스마트 폰 기반 3D 프린팅 칩을 이용한 적혈구 변형성 측정 (Measurement of RBC (red blood cell) deformability using 3D Printed Chip combined with Smartphone)

  • 이수환;홍현지;염은섭;송재민
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.103-108
    • /
    • 2020
  • RBC (red blood cell) deformability is one of factors inducing blood shear thinning effect. Reduction of RBC deformability increases blood viscosity in high shear region. In this study, 3D printed chip with proper distribution of wall shear rate (WSR) was proposed to measure RBC deformability of blood samples. To fabricate 3D printed chip, the design of 3D printed chip determined through numerical simulation was modified based on the resolution of the 3D printer. For the estimation of pressure drop in the 3D printed chip, two bypass outlets with low and high WSR are exposed to atmospheric pressure through the needles. By positioning the outlet of needles in the gravity direction, the formation of droplets at bypass outlets can be captured by smartphone. Through image processing and fast Fourier transform (FFT) analysis, the frequency of droplet formation was analyzed. Since the frequency of droplet formation is related with the pressure at bypass, high pressure drop caused by reduction of RBC deformability can be estimated by monitoring the formation of blood droplets using the smartphone.

Wnt/β-catenin 신호 활성화를 통한 미세전류 자극의 지방생성 억제 효과 (The Micro-Current Stimulation Inhibits Adipogenesis by Activating Wnt/β-Catenin Signaling)

  • 황동현;이한아;이민주;조승관;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권6호
    • /
    • pp.235-246
    • /
    • 2020
  • This study aimed to evaluate the inhibitory effect of micro-current stimulation(MCS) on adipogenesis regarding with Wnt/β-catenin pathway using the ob/ob mouse and 3T3-L1 cell line. 6-week old ob/ob male mice were equally assigned to four groups: obese group(ob), obese with MCS groups(50 μA, 200 μA, and 400 μA). 6-week old C57BL/6J male mice were assigned to the control group(CON). We analyzed abdominal adipose tissue volume by using in vivo micro-CT and measured the body weight, feed intake, liver weight and triglycerides in serum. All the MCS groups showed that significantly reduced body weight and triglycerides in serum. In the case of liver weight and abdominal adipose tissue volume, the inhibitory effect of adipogenesis was shown in the 200 μA and 400 μA groups. To elucidate the anti-obesity effect of MCS, β-catenin, C/EBPα and FAS protein expressions were analyzed by western blotting. β-catenin expression was upregulated, C/EBPα and FAS expression were down-regulated in the relatively high-intensity groups(200 μA and 400 μA). Thus, the 200 μA and 400 μA for the intensity of MCS were chosen for cell experiments. In the 3T3-L1 cell line, Wnt/β-catenin pathway including Wnt10b, Wnt3a, β-catenin and Cyclin D1 was activated in all MCS groups. Accordingly, the expression level of C/EBPα was decreased during the differentiation and lipid droplet was significantly reduced in Oil red O staining results. These results suggest that the Wnt/β-catenin signaling might be activated by MCS with current intensities between 200-400 μA and it may lead to anti-obesity effects.

NaCl과 NaBr수용액에서 적층가공으로 제조된 Ti-6Al-4V 합금의 공식 저항성 비교 (Comparing Resistances to Pitting Corrosion of Additive Manufactured Ti-6Al-4V Alloys in NaCl and NaBr Aqueous Solutions)

  • 서동일;이재봉
    • Corrosion Science and Technology
    • /
    • 제18권3호
    • /
    • pp.110-116
    • /
    • 2019
  • Resistances to pitting corrosion of additive manufactured (AM) Ti-6Al-4V alloys in 0.6 M NaBr and 0.6 M NaCl aqueous solutions were compared using micro-droplet cell techniques. With respect to the pitting corrosion resistance, this study focused on two different types of halide anions in aqueous solutions, i.e. $Br^-$ and $Cl^-$. The differences between $Br^-$ and $Cl^-$ halide anions for breakdown on passive films of AM Ti-6Al-4V alloy were explained using Langmuir adsorption model with their equilibrium adsorption coefficients. The results of the analysis showed that the lower resistance to pitting potential of AM Ti-6Al-4V alloy in $Br^-$ aqueous solution was attributed to the higher equilibrium adsorption coefficient of Br-. In addition, micro-electrochemical test results showed that the pitting corrosion resistance of dark grains in additive manufactured Ti-6Al-4V alloy was lower as compared to that of bright grains due to the larger volume of ${\alpha}^{\prime}$ phase that caused the susceptibility to pit initiation.

올레산으로 유도된 비알코올성 지방간 세포 모델에서의 미세전류 자극의 지질 대사 조절 효능 평가 (Effects of Micro-current Stimulation on lipid metabolism in Oleic Acid-Induced Non-Alcoholic Fatty Liver disease in FL83B cells)

  • 이한아;이민주;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권1호
    • /
    • pp.1-10
    • /
    • 2022
  • Non-alcoholic fatty liver disease(NAFLD) is excessive hepatic lipid accumulation mainly caused by obesity. This study aimed to evaluate whether micro-current stimulation(MCS) could modulate lipid metabolism regarding the Sirt1/AMPK pathway, fatty acid β-oxidation pathway, and lipolysis and lipogenesis-related factors in FL83B cells. For the NAFLD cell model, FL83B cells were treated with oleic acid for lipid accumulation. MCS were stimulated for 1 hr and used frequency 10 Hz, duty cycle 50%, and biphasic rectangular current pulse. The intensity of MCS was divided into 50, 100, 200, and 400 ㎂. Through the results of Oil red O staining, it was confirmed that MCSs with the intensity of 200 ㎂ and 400 ㎂ significantly reduced the degree of lipid droplet formation. Thus, these MCS intensities were applied to western blot analysis. Western blot analysis was performed to analyze the effects of MCS on lipid metabolism. MCS with the intensity of 400 ㎂ showed that significantly activated the Sirt1/AMPK pathway, a key pathway for regulating lipid metabolism in hepatocytes, and fatty acid β-oxidation-related transcription factors. Moreover, it activated the lipolysis pathway and suppressed lipogenesis-related transcription factors such as SREBP-1c, FAS, and PPARγ. In the case of MCS with the intensity of 200 ㎂, only PGC1α and SREBP-1c showed significant differences compared to cells treated only with oleic acid. Taken together, these results suggested that MCS with the intensity of 400 ㎂ could alleviate hepatic lipid accumulation by modulating lipid metabolism in hepatocytes.

5052-O 알루미늄 합금의 워터 캐비테이션 피닝 시간에 따른 표면 경화와 부식 특성에 관한 연구 (Investigation on surface hardening and corrosion characteristic by water cavitation peening with time for Al 5052-O alloy)

  • 김성종;현광룡
    • Corrosion Science and Technology
    • /
    • 제11권4호
    • /
    • pp.151-156
    • /
    • 2012
  • The cavity formed by the ultrasonic generation in the fluid with the application of water cavitation peening collides into the metal surface. At this time, the surface modification effect such as the work hardening presents by the compressive residual stress formed due to the localized plastic deformation. In this investigation, the water cavitation peening technology in the distilled water with the lapse of time was applied to 5052-O aluminum alloy for aluminum ship of a high value. So, the optimum water cavitation peening time on the effect for surface hardening and anti-corrosion property was investigated. Consequently, the water cavitatin peening time on excellent hardness and corrosion resistance characteristic presented 3.5 min. and 5.0 min, respectively. The surface hardness in the optimum water cavitation peening time was improved approximately 45% compared to the non-WCPed condition. In addition, corrosion current density was decreased.

Flow Near the Meniscus of a Pressure-Driven Water Slug in Microchannels

  • Kim Sung-Wook;Jin Song-Wan;Yoo Jung-Yul
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.710-716
    • /
    • 2006
  • Micro-PIV system with a high speed CCD camera is used to measure the flow field near the advancing meniscus of a water slug in microchannels. Image shifting technique combined with meniscus detecting technique is proposed to measure the relative velocity of the liquid near the meniscus in a moving reference frame. The proposed method is applied to an advancing front of a slug in microchannels with rectangular cross section. In the case of hydrophilic channel, strong flow from the center to the side wall along the meniscus occurs, while in the case of the hydrophobic channel, the fluid flows in the opposite direction. Further, the velocity near the side wall is higher than the center region velocity, exhibiting the characteristics of a strong shear-driven flow. This phenomenon is explained to be due to the existence of small gaps between the slug and the channel wall at each capillary corner so that the gas flows through the gaps inducing high shear on the slug surface. Simulation of the shape of a static droplet inside a cubic cell obtained by using the Surface Evolver program is supportive of the existence of the gap at the rectangular capillary corners. The flow fields in the circular capillary, in which no such gap exists, are also measured. The results show that a similar flow pattern to that of the hydrophilic rectangular capillary (i.e., center-to-wall flow) is always exhibited regardless of the wettability of the channel wall, which is also indicative of the validity of the above-mentioned assertion.