• 제목/요약/키워드: micro-channel Flow

검색결과 221건 처리시간 0.029초

스파이럴 채널을 가진 초소형 점성 펌프의 Navier-Stokes 해석 (NAVIER-STOKES SIMULATION OF A VISCOUS MICRO PUMP WITH A SPIRAL CHANNEL)

  • 서주형;강동진
    • 한국전산유체공학회지
    • /
    • 제16권1호
    • /
    • pp.90-95
    • /
    • 2011
  • The Navier-Stokes equations are solved to study the flow characteristics of a micro viscous pump. The viscous micropump is consisted of a stationary disk with a spiral shaped channel and a rotating disk. A simple geometrical model for the tip clearance is proposed and validated by comparing computed flow rate with corresponding experimental data. Present numerical solutions show satisfactory agreement with the corresponding experimental data. The tip clearance effect is found to become significant as the rotational speed increases. As the pressure load increases, a reversed flow region is seen to form near the stationary disk. The height of the channel is shown to be optimized in terms of the flow rate for a given rotational speed and pressure load. The optimal height of the channel becomes small as the rotational speed decreases or the pressure load increases. The flow rate of the pump is found to be in proportion to the width of channel.

PIV measurement of oscillatory flow in a micro-channel as a bronchiole model

  • LEE Won-je;KAWAHASHI Massaki;HIRAHARA Hiroyuki
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.125-134
    • /
    • 2004
  • The improvement of artificial respiration method has brought about the decrease in mortality of pulmonary diseases patients. Various respiratory curative methods, inclusive of HFOV (High Frequency Oscillatory Ventilation), have been developed for more effectual and less harmful management of acute respiratory failure. However, the mechanism of gas transfer and diffusion in a bronchiole has not yet been clarified in detail. As a first approach to the problem, we measured oscillatory flows in a Y-shaped micro-channels as bronchiole model by micro Particle Image Velocimetry(micro PIV). In order to establish the fundamental technique of PIV measurements on oscillatory air flow in a micro-channel, we used about 500-nm-diameter incense smoke particles, a diode laser, a high speed camera including an objective lens, and a HFOV, which is effective technique for medical care of pulmonary disease patients, especially, infants. The bronchiole model size is that parent tube is $500\{mu}m$ width and $500\{mu}m$ depth, and daughter tubes are $450\{mu}m$ width and $500\{mu}m$ depth. From this study made on the phenomenon of fluid in micro size bronchus branch of a lung, we succeeded to get time series velocity distribution in a micro scale bronchial mode. The experimental results of velocity distribution changing with time obtained by micro PIV can give fundamental knowledge on oscillatory airflow in micro-channel.

  • PDF

미소 유량 측정을 위한 마이크로 전자 유량 센서의 제작 (Fabrication of a Micro Electromagnetic Flow Sensor for Micro Flow Rate Measurement)

  • 윤현중;김순영;양상식
    • 센서학회지
    • /
    • 제9권5호
    • /
    • pp.334-340
    • /
    • 2000
  • 본 논문에서는 패러데이의 전자기 유도 법칙을 응용한 마이크로 전자 유량 센서를 제작하였다. 마이크로전자 유량 센서는 열 발생이 없고 빠른 응답 속도를 가지고 있고 압력 손실이 없는 장점을 가지고 있다. 전도성 유체가 영구 자석 자장 내의 유로를 통과할 때, 유속에 비례하는 유도 기 전력이 발생하게 되는데, 발생된 기 전력은 유로 벽에 제작된 전극으로 검출된다. 마이크로 전자 유량 센서는 유로를 가지고 있는 두 장의 실리콘 웨이퍼 기판과 전극, 그리고 두 개의 영구 자석으로 구성되어 있다. 두 장의 실리콘 웨이퍼 기판을 이방성 식각 공정으로 유로를 제작하고, Cr/Au를 증착하여 전극을 제작한다. 제작된 마이크로 전자 유량 센서에 유량을 변화시킬 때, 발생되는 기 전력을 측정한다.

  • PDF

마이크로 채널 내부 전기삼투 유동의 Zeta-potential 계측 (Measurement of Zeta-potential of Electro-osmotic Flow Inside a Micro-channel)

  • 한수동;이상준
    • 대한기계학회논문집B
    • /
    • 제30권10호
    • /
    • pp.935-941
    • /
    • 2006
  • Many important properties in colloidal systems are usually determined by surface charge $({\zeta}-potential)$ of the contacted solid surface. In this study, ${\zeta}-potential$ of glass ${\mu}-channel$ was evaluated from the electro-osmotic velocity distribution. The electro-osmotic velocity inside a glass f-channel was measured using a micro-PIV velocity field measurement technique. This evaluation method is more simple and easy to approach, compared with the traditional streaming potential technique. The ${\zeta}-potential$ in the glass ${\mu}-channel$ was measured fur two different mole NaCl solutions. The effect of an anion surfactant, sodium dodecyl sulphate (SDS), on the electro-osmotic velocity and f-potential in the glass surface was also studied. In the range of $0{\sim}6mM$, the surfactant SDS was added to NaCl solution in few different mole concentrations. As a result, the addition of SDS increases ${\zeta}-potential$ in the surface of the glass ${\mu}-channel$. The measured $\zeta-potential$ was found to vary from -260 to -70mV. When negatively charged particles were used, the flow direction was opposite compared with that of neutral particles. The ${\zeta}-potential$ has a positive sign for the negative particles.

초소형 점성 펌프의 Wavier-Stokes 해석 (NAVIER-STOKES SIMULATION OF A MICRO-VISCOUS PUMP)

  • 강동진
    • 한국전산유체공학회지
    • /
    • 제11권4호
    • /
    • pp.75-80
    • /
    • 2006
  • Navier-Stokes simulation of the flow in a micro viscous pump is carried out. The micro viscous pump consists of a rotating circular rotor placed in a two dimensional channel. All simulation is carried out by using a finite volume approach, at the Reynolds number of 0.5, to study the performance of the micro viscous pump. Length of channel of the pump is varied to simulate the effects of the pumping load. Numerical solutions show that the net flow of the pump is realized by two counter rotating vortices formed on both sides of the rotor. The volume flow rate of the pump is decreased as length of the channel is increased, while the static pressure difference across the rotor is increased. The static pressure difference across the rotor is observed to be inversely proportional to the volume flow rate as inertia effects are negligibly small. The efficiency of the pump is found to reach a maximum when two counter rotating vortices on both sides of the rotor becomes to merge forming an outer enveloping vortex.

압축성 마이크로 유동에 관한 기초 연구 (A Fundamental Study of Compressible Micro Flows)

  • 김재형;정미선;김희동;박경암
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.143-146
    • /
    • 2002
  • Recently the micro flows have been received much attention in the applications with regard to Micro Electro Mechanical Systems(MEMS). Such flows are governed by relatively large viscous forces, compared with inetia force, and frequently specified by slip wall boundary conditions. In the present study, computations are applied to investigate the compressible viscous flows through an extremely small channel, and theoretical analyses are conducted using the Fanno flow theory. The axisymmetic, compressible, Wavier-Stokes equations are numerically solved by a fully implicit finite implicit method. The predicted results are validated with previous experimental data available. The results obtained show that for small Reynolds numbers, the viscous frictional force significantly influences the compressible micro channel flows.

  • PDF

Slip flow 영역에서의 미소채널 내 열전달 및 유동에 관한 수치적 연구 (A Numerical Study of Heat transfer and Flow Analysis for a Micro-channel in The Slip Flow Regime)

  • 정수인;김귀순;강범수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.391-394
    • /
    • 2006
  • In this paper, the thermal lattice Boltzmann method(TLBM) proposed by Guo et al.(2002) is applied to analyze the forced convective flow and heat transfer of 2-D micro channel. Nonequilibrium extrapolation boundary condition is adopted to simulate the velocity and temperature behavior at wall boundaries. Numerical results obtained by the present study give a good prediction of the micro fluidic characteristics with thermal effects.

  • PDF

미소 유량 측정을 위한 마이크로 전 유량계의 제작 (Fabrication of a Micro Magnetic Flowmeter for Micro Flow Rate Measurement)

  • 윤현중;김근영;정옥찬;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3268-3270
    • /
    • 1999
  • This paper presents the fabrication of a micro electromagnetic flowmeter for liquid flow rate measurement. The flowmeter consists of a silicon flow channel with two electrodes and two permanent magnets. The micro flow channel and the detection electrodes are fabricated by the anisotropic etching of two silicon substrates and the metal evaporation process respectively. If conductive fluid passes through a magnet field, electromotive force is generated and detected by two electrodes. When the flow rate is 2.6 ml/sec, the measured output voltage is 7.4 mV.

  • PDF

미세유로채널의 새로운 제작공정 및 표면상태가 유동에 미치는 영향 (Novel Fabrication Process for Micro-Fluidic Channels and the Effect of the Surface States on the Fluid Flow)

  • 박미석;김진산;성인하;김대은;신보성
    • 한국정밀공학회지
    • /
    • 제21권1호
    • /
    • pp.87-93
    • /
    • 2004
  • Recently, with the development of bio-technology the interests in the micro-fluidic devices for analysis in the fields of biology and medical science have been steadily increasing. Although polymer is considered as one of the best materials for micro-fluidic devices. glass or silicon molds fabricated by photo-lithographic technique have been commonly used. However, it is generally perceived that the conventional photolithographic technique has the limitation for fabricating micro-channels for micro-fluidic devices. In this work, the possibility of fabrication of micro-fluidic channels on PDMS by using the mechano-chemical process and the effect of surface states on the fluid flow were investigated. Experimental results revealed that PDMS mold fabricated by the mechano-chemical process could be used effectively to replicate micro-fluidic channels with high reproducibility and dimensional accuracy. It was also found that the fluid flow generation and flow speed were largely affected by the hydrophilicity and the surface roughness of the micro-channel surfaces.

Particle Image Velocimetry of the Blood Flow in a Micro-channel Using the Confocal Laser Scanning Microscope

  • Kim, Wi-Han;Kim, Chan-Il;Lee, Sang-Won;Lim, Soo-Hee;Park, Cheol-Woo;Lee, Ho;Park, Min-Kyu
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.42-48
    • /
    • 2010
  • We used video-rate Confocal Laser Scanning Microscopy (CLSM) to observe the motion of blood cells in a micro-channel. Video-rate CLSM allowed us to acquire images at the rate of 30 frames per second. The acquired images were used to perform Particle Image Velocimetry (PIV), thus providing the velocity profile of the blood in a micro-channel. While previous confocal microscopy-assisted PIV required exogenous micro/nano particles as the tracing particles, we employed blood cells as tracing particles for the CLSM in the reflection mode, which uses light back-scattered from the sample. The blood flow at various depths of the micro-channel was observed by adjusting the image plane of the microscope. The velocity profile at different depths of the channel was measured. The confocal micro-PIV technique used in the study was able to measure blood velocity up to a few hundreds ${\mu}m/sec$, equivalent to the blood velocity in the capillaries of a live animal. It is expected that the technique presented can be applied for in vivo blood flow measurement in the capillaries of live animals.