• Title/Summary/Keyword: micro-array

Search Result 473, Processing Time 0.039 seconds

A Temperature-Controllable Microelectrode and Its Application to Protein Immobilization

  • Lee, Dae-Sik;Choi, Hyoung-Gil;Chung, Kwang-Hyo;Lee, Bun-Yeoul;Pyo, Hyeon-Bong;Yoon, Hyun-C.
    • ETRI Journal
    • /
    • v.29 no.5
    • /
    • pp.667-669
    • /
    • 2007
  • This letter presents a smart integrated microfluidic device which can be applied to actively immobilize proteins on demand. The active component in the device is a temperature-controllable microelectrode array with a smart polymer film, poly(N-isopropylacrylamide) (PNIPAAm) which can be thermally switched between hydrophilic and hydrophobic states. It is integrated into a micro hot diaphragm having an integrated micro heater and temperature sensors on a 2-micrometer-thick silicon oxide/silicon nitride/silicon oxide (O/N/O) template. Only 36 mW is required to heat the large template area of 2 mm${\times}$16 mm to $40^{\circ}C$ within 1 second. To relay the stimulus-response activity to the microelectrode surface, the interface is modified with a smart polymer. For a model biomolecular affinity test, an anti-6-(2, 4-dinitrophenyl) aminohexanoic acid (DNP) antibody protein immobilization on the microelectrodes is demonstrated by fluorescence patterns.

  • PDF

Analysis and Experiment of Ultrasonic Vibration Mechanism using PZT Actuator for Precision Laser Machining (압전구동기를 이용한 정밀 가공용 초음파 진동장치 해석 및 실험)

  • Kim, Woo-Jin;Jeon, Yong-Ho;Cho, Sung-Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1347-1352
    • /
    • 2011
  • Recently, as the aged population grows around the world, many medical instruments, devices, and their fabrication processes are developing. Among the devices, a drug delivery stent is a good example for precision machining. Conventional drug delivery stent has problem of the remaining polymer because the drug is coated on the surface with it. If the drug is impregnated into the micro hole array on the stent surface, the polymer can be perfectly eliminated. Micro sized holes are generally fabricated by laser machining however, the fabricated holes do not have an enough aspect ratio to contain the drug or a good surface finish to deliver the stend to blood vessel tissue. To overcome these problems, we propose a vibration-assisted machining mechanism with PZT (Piezoelectric Transducers) for abrication of micro sized holes better. The results indicated that the burr size can be significantly decreased with vibration assisted in nanosecond pulse laser drilling test.

Generation of Lens surface by moving mask lithography (가변 속도 이동식 마스크를 이용한 렌즈 곡면 형성)

  • Lee Joon-Sub;Park Woo-Jae;Song Seok-Ho;Oh Cha-Hwan;Kim Pill-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.508-515
    • /
    • 2005
  • We propose a fabrication method for refractive lens by variable velocity moving mask lithography and slit pattern. Distribution of exposure dose should be controlled for the curved photoresist surface that works as a refractive surface. We analyze theoretically the distribution of exposure dose by change of moving velocity, moving direction of mask and the shape of mask pattern, and confirm for the curved surface experimentally. The lens could have sag height of a few of hundreds ${\mu}m$, by using thick photoresist or Deep RIE process.

Simultaneous and Multi-frequency Driving System of Ultrasonic Sensor Array for Object Recognition

  • Park, S.C.;Choi, B.J.;Lee, Y.J.;Lee, S.R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.582-587
    • /
    • 2004
  • Ultrasonic sensors are widely used in mobile robot applications to recognize external environments, because they are cheap, easy to use, and robust under varying lighting conditions. However, the recognition of objects using a ultrasonic sensor is not so easy due to its characteristics such as narrow beam width and no reflected signal from a inclined object. As one of the alternatives to resolve these problems, use of multiple sensors has been studied. A sequential driving system needs a long measurement time and does not take advantage of multiple sensors. Simultaneous and pulse coding driving system of ultrasonic sensor array cannot measure short distance as the length of the code becomes long. This problem can be resolved by multi-frequency driving of ultrasonic sensors, which allows multi-sensors to be fired simultaneously and adjacent objects to be distinguished. Accordingly, this paper presents a simultaneous and multi-frequency driving system for an ultrasonic sensor array for object recognition. The proposed system is designed and implemented using a DSP and FPGA. A micro-controller board is made using a DSP, Polaroid 6500 ranging modules are modified for firing the multi-frequency signals, and a 5-channel frequency modulated signal generating board is made using a FPGA. To verify the proposed method, experiments were conducted in an environment with overlapping signals, and the flight distances for each sensor were obtained from filtering of the received overlapping signals and calculation of the time-of-flights.

  • PDF

Portable Amperometric Perchlorate Selective Sensors with Microhole Array-water/organic Gel Interfaces

  • Lee, Sang Hyuk;Kim, Hyungi;Girault, Hubert H.;Lee, Hye Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2577-2582
    • /
    • 2013
  • A novel stick-shaped portable sensing device featuring a microhole array interface between the polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel and water phase was developed for in-situ sensing of perchlorate ions in real water samples. Perchlorate sensitive sensing responses were obtained based on measuring the current changes with respect to the assisted transfer reaction of perchlorate ions by a perchlorate selective ligand namely, bis(dibenzoylmethanato)Ni(II) (Ni(DBM)2) across the polarized microhole array interface. Cyclic voltammetry was used to characterize the assisted transfer reaction of perchlorate ions by the $Ni(DBM)_2$ ligand when using the portable sensing device. The current response for the transfer of perchlorate anions by $Ni(DBM)_2$ across the micro-water/gel interface linearly increased as a function of the perchlorate ion concentration. The technique of differential pulse stripping voltammetry was also utilized to improve the sensitivity of the perchlorate anion detection down to 10 ppb. This was acquired by preconcentrating perchlorate anions in the gel layer by means of holding the ion transfer potential at 0 mV (vs. Ag/AgCl) for 30 s followed by stripping the complexed perchlorate ion with the ligand. The effect of various potential interfering anions on the perchlorate sensor was also investigated and showed an excellent selectivity over $Br^-$, $NO_2{^-}$, $NO_3{^-}$, $CO{_3}^{2^-}$, $CH_3COO^-$ and $SO{_4}^{2^-}$ ions. As a final demonstration, some regional water samples from the Sincheon river in Daegu city were analyzed and the data was verified with that of ion chromatography (IC) analysis from one of the Korean-certified water quality evaluation centers.

Recent Development of Protein Microarray and Proteogen Platform

  • Han, Moon-Hi;Kang, In-Cheol;Lee, Yoon-Suk;Cho, Yong-Wan;Lee, Eun-Kyoung
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.47-47
    • /
    • 2005
  • There are many different surface technologies currently applied for preparation of protein chips. However, it requires innovative surface chemistry for capture proteins to be immobilized on chip surface keeping their conformation and activity intact and their orientation right, while they bind tightly and densely in a given array spot. Proteogen has developed 'ProteoChip BP' coated with novel proprietary linker molecules $(ProLinker^{TM})$ for efficient and robust immobilizations of capture proteins by improving surface properties of molecular captures. It was demonstrated that $ProLinker^{TM}$ gave the best surface performance in preparation of protein microarray chip base plates among others currently available on the market. In particular, the $ProLinker^{TM}-based$ surface chemistry has demonstrated to provide excellent performance in preparation of 'Antibody Chip' for analysis of biomarkers as well as proteome expression profiles. The linker molecule has also shown to be well applicable for development of biosensors and micro-beads as well as protein microarray and nano-array. ProteoChip BP can be used either for preparation of high-density array by using a microarrayer or for preparation of 'Well-on-a-Chip' with low density array, which is better applicable for quantitative analysis of biomarkers or protein-protein interactions. The biomarker assay can be performed either by direct or sandwich methods of fluorescence immunoassay. Application of ProteoChip BP has been well demonstrated by the extensive studies of 1) tumor-marker assays, 2) new drug screening by using 'Integrin Chip' and 3) protein expression profile analysis. Some of experimental results will be presented.

  • PDF

A Study of 2D Micro-patterning of Biodegradable Polymers by MEA (Multi Electrode Array)-based Electrohydrodynamic (EHD) printing (다중 전극 어레이 기반 전기수력학 인쇄 기술을 이용한 생분해성 고분자의 2차원 마이크로 패터닝 연구)

  • Hwang, Tae Heon;Ryu, WonHyoung
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.111-118
    • /
    • 2017
  • Electrohydrodynamic (EHD) printing with the aid of strong electric fields can generate and pattern droplets that are smaller than droplets by other printing technologies. Conventional EHD printing has created two-dimensional (2D) patterns by moving its nozzle or a substrate in X and Y directions. In this study, we aimed to develop an EHD system that can create 2D patterns using a multielectrode array (MEA) without moving a nozzle or substrate. In particular, printing ink mixtures of biodegradable polymers and model dyes was patterned on a thin film made of another biodegradable polymer. Without movement of a nozzle and substrate, stable 2D patterning of minimum $6{\mu}m$ size over a range of about 1 mm away from the nozzle position was achieved by MEA control only. We also demonstrated the possibility of denser 2D pattering of the ink mixtures by moving a target substrate relative to MEA position.

A Cylindrical Hybrid Antenna for Shaping Complex Beam Patterns (복합 빔 패턴 형성을 위한 원통형 하이브리드 안테나)

  • Eom, Soon-Young;Jung, Young-Bae;Jeon, Soon-Ick;Kim, Chang-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1279-1290
    • /
    • 2007
  • In this paper, a cylindrical hybrid antenna which is spatially fed by an off-set linear feed array is described to form complex beam patterns. The linear feed array consists of twelve micro-strip patch elements and forms a flat-topped beam pattern with a beam-width of $90^{\circ}$ in the horizontal plane. The vertical curve on the cylindrical reflector with the linear feed array is shaped in order to form a cosecant beam pattern within the range of $-5^{\circ}$ to $-25^{\circ}$ in the vertical plane. To form complex beam patterns, the hybrid antenna with cylindrical reflector aperture of $140{\times}50\;cm$ was designed and fabricated to be operated within the IMT 2000 service band, and also electrical performances of the antenna were measured and analyzed.

Design of a Micro-strip Patch Array Antenna using CRLH Transmission Line Power Divider Supporting Infinite Wavelength (무한파장 전파특성을 갖는 CRLH 전송선로 전력 분배기를 이용한 마이크로스트립 패치 배열 안테나의 설계)

  • Kim, Jung-hyung;Lee, Hong-min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.2
    • /
    • pp.39-45
    • /
    • 2010
  • In this paper, an equally spaced $3{\times}2$ microstrip patch array antenna based on the fundamental infinite wavelength supported by the composite right/left-handed (CRLH) transmission line (TL) is proposed. The proposed CRLH TL unit cell consists of an inter-digit capacitor to realize left-handed (LH) series capacitance and non-symmetric shunt meander line with a shorted via to realize LH shunt inductance. At the infinite wavelength frequency of 2.09 GHz a 6-port series power divider consisting of a 19 unit cells shows a maximum magnitude difference of 0.73 dB and a $0.52^{\circ}$ maximum phase difference between output ports. The measured resonant frequency and maximum gain of the fabricated array antenna is 2.09 GHz and 10.98 dBi, respectively.

  • PDF

miR-205 in Situ Expression and Localization in Head and Neck Tumors - a Tissue Array Study

  • Ab Mutalib, Nurul-Syakima;Lee, Learn-Han;Cheah, Yoke-Kqueen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9071-9075
    • /
    • 2014
  • Background: microRNAs are small non-coding RNA that control gene expression by mRNA degradation or translational inhibition. These molecules are known to play essential roles in many biological and physiological processes. miR-205 may be differentially expressed in head and neck cancers; however, there are conflicting data and localization of expression has yet to be determined. Materials and Methods: miR-205 expression was investigated in 48 cases of inflammatory, benign and malignant tumor tissue array of the neck, oronasopharynx, larynx and salivary glands by Locked Nucleic Acid in situ hybridization (LNA-ISH) technology. Results: miR-205 expression was significantly differentially expressed across all of the inflammatory, benign and malignant tumor tissues of the neck. A significant increase in miR-205 staining intensity (p<0.05) was observed from inflammation to benign and malignant tumors in head and neck tissue array, suggesting that miR-205 could be a biomarker to differentiate between cancer and non-cancer tissues. Conclusions: LNA-ISH revealed that miR-205 exhibited significant differential cytoplasmic and nuclear staining among inflammation, benign and malignant tumors of head and neck. miR-205 was not only exclusively expressed in squamous epithelial malignancy. This study offers information and a basis for a comprehensive study of the role of miR-205 that may be useful as a biomarker and/or therapeutic target in head and neck tumors.