• Title/Summary/Keyword: micro switch

Search Result 115, Processing Time 0.025 seconds

Analysis of Pull-in-Voltage and Figure-of-Merit of Capacitive MEMS Switch

  • Saha, Rajesh;Maity, Santanu;Devi, Ngasepam Monica;Bhunia, Chandan Tilak
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.3
    • /
    • pp.129-133
    • /
    • 2016
  • Theoretical and graphical analysis of pull-in-voltage and figure of merit for a fixed-fixed capacitive Micro Electromechanical Systems (MEMS) switch is presented in this paper. MEMS switch consists of a thin electrode called bridge suspended over a central line and both ends of the bridge are fixed at the ground planes of a coplanar waveguide (CPW) structure. A thin layer of dielectric material is deposited between the bridge and centre conductor to avoid stiction and provide low impedance path between the electrodes. When an actuation voltage is applied between the electrodes, the metal bridge acquires pull in effect as it crosses one third of distance between them. In this study, we describe behavior of pull-in voltage and figure of merit (or capacitance ratio) of capacitive MEMS switch for five different dielectric materials. The effects of dielectric thicknesses are also considered to calculate the values of pull-in-voltage and capacitance ratio. This work shows that a reduced pull-in-voltage with increase in capacitance ratio can be achieved by using dielectric material of high dielectric constant above the central line of CPW.

A Study on the Diagnostic System for Architectural Elements Using Radio Frequency (무선주파수를 응용한 건축부재의 손상자현 시스템에 관한 연구)

  • Kim, Dong Hyun;Choi, Young Wha
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.1-9
    • /
    • 2012
  • Reinforced concrete buildings will be deteriorated as passed time or effect of an earthquake, etc in main elements. In order to manage such cracks, time and efforts, expense, etc, are required. So micro lead switch sensors are embedding or bonding in flexible specimens, and these are smart elements for diagnostic crack damages by external force such as physical load, dynamic load, etc in this study. The monitoring to crack damages are studied using radio frequency system. If load is received on the center of flexible specimens, embedded and bonded lead switch sensors will be destroyed, and these become to send signals of damages at radio frequency system connected with lead switch sensors. This study is fundamental research of the diagnostic system for architectural elements using radio frequency.

A Study on the Design of Switch for High Speed Internet Communication Network (고속 인터넷 통신망을 위한 스위치 설계에 관한 연구)

  • 조삼호
    • Journal of Internet Computing and Services
    • /
    • v.3 no.3
    • /
    • pp.87-93
    • /
    • 2002
  • A complex network and a parallel computer are made up of interconnected switching units. The role of a switching unit is to set up a connection between an input port and an output port, according to the routing information. We proposed our switching network with a remodeled architecture is a newly modified Banyan network with eight input and output ports. We have analysed the maximum throughput of the revised switch. Our analyses have shown that under the uniform random traffic load, the FIFO discipline is limited to 70%, The switching system consists of an input control unit, a switch unit and an output control unit. Therefore the result of the analyses shows that the results of the networking simulation with the new switch are feasible and if we adopt the new architecture of the revised model of the Banyan switch, the hardware complexity can be reduced. The FIFO discipline has increased by about 11% when we compare the switching system with the input buffer system. We have designed and verified the switching system in VHDL using Max+plusII. We also designed our test environment including micro computers, the base station, and the proposed architecture. We proposed a new architecture of the Banyan switch for BISDN networks and parallel computers.

  • PDF

Evaluation of DNA Extraction Methods from Low Copy Number (LCN) DNA Samples for Forensic DNA Typing

  • Eom, Yong-Bin
    • Biomedical Science Letters
    • /
    • v.15 no.3
    • /
    • pp.229-232
    • /
    • 2009
  • DNA isolation for PCR-based short tandem repeat (STR) analysis is essential to recover high yields of amplifiable DNA from low copy number (LCN) DNA samples. There are different methods developed for DNA extraction from the small bloodstain and gloves, commonly found at crime scenes. In order to obtain STR profiles from LCN DNA samples, DNA extraction protocols, namely the automated $iPrep^{TM}$ $ChargeSwitch^{(R)}$ method, the automated $QIAcube^{TM}$ method, the automated $Maxwell^{(R)}$ 16 DNA $IQ^{TM}$ Resin method, and the manual $QIAamp^{(R)}$ DNA Micro Kit method, were evaluated. Extracted DNA was quantified by the $Quantifiler^{TM}$ Human DNA Quantification Kit and DNA profiled by $AmpFISTR^{(R)}$ $Identifiler^{(R)}$ Kit. Results were compared based on the amount of DNA obtained and the completeness of the STR profiles produced. The automated $iPrep^{TM}$ $ChargeSwitch^{(R)}$ and $QIAcube^{TM}$ methoas produced reproducible DNA of sufficient quantity and quality trom the dried blood spot. This two automated methods showed a quantity and quality comparable to those of the forensic manual standard protocols normally used in our laboratory. In our hands, the automated DNA extraction method is another obvious choice when the forensic case sample available is bloodstain. The findings of this study indicate that the manual simple modified $QIAamp^{(R)}$ DNA Micro Kit method is best method to recover high yields of amplifiable DNA from the numerous potential sources of LCN DNA samples.

  • PDF

Single-panel simulation on liquid crystal on silicon

  • Liao, Engle;Chiu, Jack;Peng, James
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.939-942
    • /
    • 2004
  • In this study, we report simulation results of single-panel LCOS (liquid crystal on silicon). Reflective LCOS microdisplays are widely used in various projection and near-eye application. For one panel system, liquid crystal response time is an important variable. The panel must switch fast enough to support the display of Field color sequential with high field rates. In order to have fast response and good contrast, a vertical alignment (VA) cell was used in this study. With suitable selection on LC parameters like temperature, viscosity, elastic constant and birefringence, it is possible to get response time of around 2ms from a 2.0 um-thick vertical alignment cell. This result also indicates an ease of production control on 2.0 um cells than 1.0 um cells.

  • PDF

A New Inter-group Handoff Scheme in Micro/Pico Cellular System using Optical Fiber Feeder

  • Chung Young uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.3A
    • /
    • pp.203-208
    • /
    • 2005
  • To solve the cost problem of micro/picocell system, the fiber-optic cellular system was proposed. In this system, all channel elements are managed in Central Station, not in each base station. Also, all channel elements in a system can be dynamically assigned when the Spectrum Delivery Switch (SDS) is used. In this paper, we propose and analyze a new intergroup handoff scheme in the fiber-optic cellular system. The proposed scheme supports handoff with keeping current channel. Performance is evaluated with respect to the blocking probability and the handoff refused probability in both systems with SDS and without SDS. The numerical results show that the proposed scheme provides better performance than conventional soft handoff scheme.

Optimum Design of a Micro-fluidic Oscillator (유체 진동자의 최적 설계)

  • 노유정;윤성기;김문언
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.1
    • /
    • pp.22-30
    • /
    • 2004
  • A micro-fluidic oscillator is used to control a linear actuator in a dynamic microsystem. The pressure difference at its two output ports causes the linear actuator to move, and it is a standard of judging the performance of the oscillator. The performance can be improved by optimizing the geometry of the oscillator, which has to enable fluid jet to switch at low inlet velocity. For this, in this study the relationship between the pressure coefficient (difference) and geometric parameters is obtained through the analysis using the software FLUENT. From the results the optimized model that maximize the output pressure difference is obtained by using a cyclic coordinate method that is one of optimization methods. As a result not only the performance is improved, but also the working range is more widen.

Analysis of an AC/DC Resonant Pulse Power Converter for Energy Harvesting Using a Micro Piezoelectric Device

  • Chung Gyo-Bum;Ngo Khai D.T.
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.247-256
    • /
    • 2005
  • In order to harvest power in an efficient manner from a micro piezoelectric (PZT) device for charging the battery of a remote system, a new AC/DC resonant pulse power converter is proposed. The proposed power converter has two stages in the power conversion process. The first stage includes N-type MOSFET full bridge rectifier. The second stage includes a boost converter having an N-type MOSFET and a P-type MOSFET. MOSFETs work in the $1^{st}$ or $3^{rd}$ quadrant region. A small inductor for the boost converter is assigned in order to make the size of the power converter as small as possible, which makes the on-interval of the MOSFET switch of the boost converter ultimately short. Due to this short on-interval, the parasitic junction capacitances of MOSFETs affect the performance of the power converter system. In this paper, the performance of the new converter is analytically and experimentally evaluated with consideration of the parasitic capacitance of switching devices.

Production of IFN-γ by TNF-α in Macrophages from Tumor Micro Environment; Significance in Angiogenic Switch Control (종양 미세 환경 내 대식세포에서 혈관 신생 조절 인자로서의 TNF-α에 의한 IFN-γ의 분비 조절)

  • Pyo, Suhk-Neung;Baek, Soyoung;Kwak, Jang-Dong;Park, Dae-Sub;Joe, Sung-Jun;Lee, Hyun Ah
    • IMMUNE NETWORK
    • /
    • v.3 no.1
    • /
    • pp.53-60
    • /
    • 2003
  • Background: The role of macrophages in tumor angiogenesis is known to be the production of angiogenic cytokines and growth factors including TNF-${\alpha}$. Recently, macrophage also can produce the INF-${\gamma}$ that is being studied to be involved in angiogenic inhibition. Thus, the importance of macrophages in tumor angiogenesis is might being an angiogenic switch. Thus, the hypothesis tested here is that TNF-${\alpha}$ can modulate the INF-${\gamma}$ production in the macrophages from tumor environment as a part of tumor angiogenic switch. Methods: Macrophages in tumor environment were obtained from the peritoneal cavity of C57BL/6 mice injected with B16F10 melanoma cell line for 6 or 11 days. $Mac1^+$-macrophages were purified using magnetic bead ($MACs^{TM}$; Milteny Biotech, Germany) and cultured with various concentrations of TNF-${\alpha}$ for various time points at $37^{\circ}C$. The supernatants were analyzed for IFN-${\gamma}$ or VEGF by ELISA kit (Endogen, Woburn, MA). Results: Residential macrophages from the peritoneal cavity did not respond to LPS or TNF-${\alpha}$ to produce INF-${\gamma}$. However, the cells from tumor environment produced IFN-${\gamma}$ as well as VEGF and upregulated by the addition of LPS or TNF-${\alpha}$. RT-PCR analysis revealed the external TNF-${\alpha}$-induced IFN-${\gamma}$ gene expression in the macrophages from tumor environment. Conclusion: The overall data suggest that the macrophages in tumor environment might have an important role not only in angiogenic signal but also in anti-angiogenic signal by producing related cytokines. And TNF-${\alpha}$ might be a key cytokine in tumor angiogenic switch.

Thermo-optic Characteristics of Micro-structured Optical Fiber Infiltrated with Mixture Liquids

  • Wang, Ran;Wang, Yuye;Miao, Yinping;Lu, Ying;Luan, Nannan;Hao, Congjing;Duan, Liangcheng;Yuan, Cai;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.231-236
    • /
    • 2013
  • We present both theoretically and experimentally the thermo-optic characteristics of micro-structured optical fiber (MOF) filled with mixed liquid. The performance of MOF depends on the efficient interaction between the fundamental mode of the transmitted light wave and the tunable thermo-optic materials in the cladding. The numerical simulation indicates that the confinement loss of MOF presents higher temperature dependence with higher air-filling ratios $d/{\Lambda}$, longer incident wavelength and fewer air holes in the cladding. For the 4cm liquid-filled grapefruit MOF, we demonstrate from experiments that different proportions of solutions lead to tunable temperature sensitive ranges. The insertion loss and the extinction ratio are 3~4 dB and approximate 20 dB, respectively. The proposed liquid-filling MOF will be developed as thermo-optic sensor, attenuator or optical switch with the advantages of simple structure, compact configuration and easy fabrication.