• Title/Summary/Keyword: micro fracture

Search Result 438, Processing Time 0.027 seconds

COMPARATIVE STUDY ON MORPHOLOGY OF CROSS-SECTION AND CYCLIC FATIGUE TEST WITH DIFFERENT ROTARY NITI FILES AND HANDLING METHODS (수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향)

  • Kim, Jae-Gwan;Kum, Kee-Yeon;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2006
  • There are various factors affecting the fracture of NiTi rotary files. This study was performed to evaluate the effect of cross sectional area, pecking motion and pecking distance on the cyclic fatigue fracture of different NiTi files. Five different NiTi $files-Profile^{(R)}$ (Maillefer, Ballaigue, Switzerland), $ProTaper^{TM}$(Maillefer, Ballaigue, Switzerland), $K3^{(R)}$ (SybronEndo. Orange, CA) , Hero $642^{(R)}$ (Micro-mega, Besancon, France), Hero $Shaper^{(R)}$ (Micro-mega, Besancon, France)-were used. Each file was embedded in temporary resin, sectioned horizontally and observed with scanning electron microscope. The ratio of cross-sectional area to the circumscribed circle was calculated. Special device was fabricated to simulate the cyclic fatigue fracture of NiTi file in the curved canal,. On this device, NiTi files were rotated (300rpm) with different pecking distances (3 mm or 6 mm) and with different motions (static motion or dynamic pecking motion) . Time until fracture occurs was measured. The results demonstrated that cross-sectional area didn't have any effect on the time of file fracture. Among the files, $Profile^{(R)}$ took the longest time to be fractured. Between the pecking motions, dynamic motion took the longer time to be fractured than static motion. There was no significant difference between the pecking distances with dynamic motion, however with static motion, the longer time was taken at 3mm distance. In this study, we could suggest that dynamic pecking motion would lengthen the time for NiTi file to be fractured from cyclic fatigue.

A COMPARATIVE STUDY OF BOND STRENGTH OF RECYCLED BRACKETS (재생 브라켓의 전단접착강도에 관한 비교 연구)

  • Shur, Cheong-Hoon;Choi, Eun-Ah
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.641-657
    • /
    • 1998
  • This study was undertaken to compare the bond strength and the fracture site of new and recycled brackets according to the base design. 252 sound premolars extracted for orthodontic treatment were collected and Type I, Type II, Type III brackets were divided into four groups by recycling method Each bracket was then bonded to an extracted premolar. Instron Universal Testing Machine(model W) was used to measure the shear bond strength, and the surface of the recycled brackets were viewed in SEM For the analysis of the results, one way ANOVA and Scheffe's multiple range test was executed using the SPSSWIN program. 1. The shear bond strength showed statistically significant difference according to the bracket base design(p<0.001). Type III bracket(round indentation base, micro-etched) showed the highest bond strength, Type I bracket(foil-mesh base) was second, and Type II bracket(grooved integral base, micro-etched) was last. 2. The effect of recycling on the bond strength was different according to bracket type. The shear bond strength of Type I, Type II brackets showed the smallist reduction when treated for 1 minute in Big Jane(p<0.05), but the shear bond strength of Type III brackets showed no statistically significant difference according to recycling method(p>0.05). 3. In Type I, Type II brackets, frequent fracture site was bracket-resin interface, but in Type III brackets, about half of the resin was retained on the tooth surface frequently. 4. The shear bond strength was highest when about half of the resin was retained on the tooth surface(p<0.05). 5. The resin remnant on the bracket base after recycling had no effect on the shear bond strength.

  • PDF

Fracture Analysis of Porous Titanium for Dental Implant Fabricated by Space Holder Process (Space holder 공정으로 제조된 치과 임플란트용 타이타늄 다공체의 파손 분석)

  • Lee, Seung-Mi;Jang, Jin-Man;Lee, Won-Sik;Byeon, Jai-Won
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.104-109
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze fracture behavior and failure mechanism of porous titanium for dental implant fabricated by space holder process. Method: Three porous titanium specimens with a specific volume fraction of open pore were test by 3 point bending and compression stress condition, respectively. Fracture appearance was observed by scanning electron microscope and discussed in relation with oxygen content. Results: For compression-tested specimens, two specimen showed brittle failure, while the other one showed normal failure after deformation. High oxygen content was detected in the brittle-fractured specimen. Several micro-cracks initiated at the struts propagated down to the bottom of the specimen resulting in normal failure. Conclusion: Oxygen contamination during the fabrication process can leads brittle premature failure, and hence quality problem of the porous titanium for dental implant.

The tensile deformation and fracture behavior of a magnesium alloy nanocomposite reinforced with nickel

  • Srivatsan, T.S.;Manigandan, K.;Godbole, C.;Paramsothy, M.;Gupta, M.
    • Advances in materials Research
    • /
    • v.1 no.3
    • /
    • pp.169-182
    • /
    • 2012
  • In this paper the intrinsic influence of micron-sized nickel particle reinforcements on microstructure, micro-hardness tensile properties and tensile fracture behavior of nano-alumina particle reinforced magnesium alloy AZ31 composite is presented and discussed. The unreinforced magnesium alloy (AZ31) and the reinforced nanocomposite counterpart (AZ31/1.5 vol.% $Al_2O_3$/1.5 vol.% Ni] were manufactured by solidification processing followed by hot extrusion. The elastic modulus and yield strength of the nickel particle-reinforced magnesium alloy nano-composite was higher than both the unreinforced magnesium alloy and the unreinforced magnesium alloy nanocomposite (AZ31/1.5 vol.% $Al_2O_3$). The ultimate tensile strength of the nickel particle reinforced composite was noticeably lower than both the unreinforced nano-composite and the monolithic alloy (AZ31). The ductility, quantified by elongation-to-failure, of the reinforced nanocomposite was noticeably higher than both the unreinforced nano-composite and the monolithic alloy. Tensile fracture behavior of this novel material was essentially normal to the far-field stress axis and revealed microscopic features reminiscent of the occurrence of locally ductile failure mechanisms at the fine microscopic level.

Prediction of fracture toughness for turbine rotor steels from their mechanical test results (터어빈 로우터용 강에 대한 기계적 성질로부터 파괴인성치$K_IC$예측에 관한 연구)

  • 이학문;정순호;장윤석;이치우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.5
    • /
    • pp.717-724
    • /
    • 1987
  • Mechanical properties tests and fracture toughness tests of turbine rotors were performed in the wide range of temperatures, -150.deg.C-+150.deg.C, and fracture toughness values from above tests were compared with the estimated values from mechanical properties at lower and upper shelf temperatures and FATT. The relations between mechanical properties and $K_{IC}$ properties proposed by Rolfe and Begley were reviewed and confirmed through these experimental results. On the fracture surfaces of some specimens which were satisfied with the Ikeda's $K_{IC}$ criterion micro dimple zone was detected at the rear of fatigue crack zone and it was confirmed that these specimens were not satisfied with the thickness requirement of ASTM E 399.E 399.

A STUDY FOR THE BONDING STRENGTH OF COMPOSITE RESIN CORE TO GLASS FIBER POST (Glass Fiber Post와 Composite Resin Core의 전단결합강도)

  • Kim Tae-Hyoung;Shim June-Sung;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.415-425
    • /
    • 2005
  • Statement of problem : Fracture of composite resin core will be occulted by progress of crack. Bonding interface of different materials has large possibility of starting point of crack line. Therefore, the bond strength of glass fiber post to composite resin core is important for prevention of fracture. Purpose: This in vitro study tried to find out how to get the higher strength of glass fiber post to composite resin core through surveying the maximum load that fractures the post and cote complex. Materials and methods: 40 specimens made with glass fiber Posts(Style $post^{(R)}$, Metalor, Swiss) and composite resin core ($Z-100^{(R)}$, 3M, USA) were prepared and loaded to failure with push-out type shear-bond strength test in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with four different surface treatments. With the data. ANOVA test was used to validate the significance between the test groups, and Bonferroni method was used to check if there is any significant statistical difference between each test group. Evely analysis was approved with 95% reliance. Results: On measuring the maximum fracture load of specimens, both the treatments of sandblasted and acid-etched one statistically showed the strength increase rather than the control group (p<0.005). The scanning electric microscope revealed that sand blasting made more micro-retention form not only on the resin matrix but on the glass fiber, and acid-etching contributed to increase in surface retention form, eliminated the inorganic particles in resin matrix. Specimen fracture modes investigation represented that sand blasted groups showed lower bonding failure than no-sand blasted groups. Conclusion: Referring to the values of maximum fracture load of specimens, the bonding strength was increased by sand blasting and acid-etching.

Study of Optical Fiber Sensor Systems for the Simultaneous Monitoring of Fracture and Strain in Composite Laminates (복합적층판의 변형파손 동시감지를 위한 광섬유 센서 시스템에 관한 연구)

  • 방형준;강현규;홍창선;김천곤
    • Composites Research
    • /
    • v.16 no.3
    • /
    • pp.58-67
    • /
    • 2003
  • To perform the realtime strain and fracture monitoring of the smart composite structures, two optical fiber sensor systems are proposed. The two types of the coherent sources were used for fracture signal detection - EDFA with FBG and EDFA with Fabry-Perot filter. These sources were coupled to EFPI sensors imbedded in composite specimens. To understand the characteristics of matrix crack signals, at first, we performed tensile tests using surface attached PZT sensors by changing the thickness and width of the specimens. This paper describes the implementation of time-frequency analysis such as short time Fourier transform (STFT) and wavelet transform (WT) for the quantitative evaluation of fracture signals. The experimental result shows the distinctive signal features in frequency domain due to the different specimen shapes. And, from the test of tensile load monitoring using optical fiber sensor systems, measured strain agreed with the value of electric strain gage and the fracture detection system could detect the moment of damage with high sensitivity to recognize the onset of micro-crack fracture signal.

A Study on the Microscopic Fracture Characteristics of A533B-1 Nuclear Pressure Vessel Steels (A533B-1 원자로 압력용기 강의 미시적 파괴특성에 관한 연구)

  • Jang, Chang-Heui;Kim, In-Sup;Park, Soon-Pil
    • Nuclear Engineering and Technology
    • /
    • v.21 no.3
    • /
    • pp.165-170
    • /
    • 1989
  • The strain rate effects on fracture toughness and fracture resistance characteristics of A533B-1 nuclear pressure vessel steels were examined in the quasi-dynamic test conditions through the microscopic investigation of the intense strain region around crack tip and the microroughness of fracture surface. J-value calculated from the recrystallization etch technique was the same as calculated from the modified-J when the crack extension is less than 1.5mm in a 1/2T-CT specimen. Local fracture strain was calculated from the fracture surface micro-roughness. The local strains were calculated to be the values of 1.8 and 2.0 and were much higher than the macroscopically measured values. It was nearly independent on strain rate and was regarded as a material constant in ductile dimpled rupture. The fracture toughness increased with increase in strain rate while the tearing modulus showed little variation.

  • PDF

Effect of thermal-induced microcracks on the failure mechanism of rock specimens

  • Khodayar, Amin;Nejati, Hamid Reza
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.93-100
    • /
    • 2018
  • It is seldom possible that geotechnical materials like rocks and concretes found without joints, cracks, or discontinuities. Thereby, the impact of micro-cracks on the mechanical properties of them is to be considered. In the present study, the effect of micro-crack on the failure mechanism of rock specimens under uniaxial compression was investigated experimentally. For this purpose, thermal stress was used to induce micro-cracks in the specimens. Several cylindrical and disk shape specimens were drilled from granite collected from Zanjan granite mine, Iran. Some of the prepared specimens were kept in room temperature and the others were heated by a laboratory furnace to different temperature levels (200, 400, 600, 800 and 1000 degree Celsius). During the experimental tests, Acoustic Emission (AE) sensors were used to monitor specimen failure at the different loading sequences. Also, Scanning Electron Microscope (SEM) was used to distinguish the induced micro-crack by heating in the specimens. The fractographic analysis revealed that the thin sections heated to $800^{\circ}C$ and $1000^{\circ}C$ contain some induced micro-fractures, but in the thin sections heated to $200^{\circ}C$, $400^{\circ}C$ and $600^{\circ}C$ have not been observed any micro-fracture. In the next, a comprehensive experimental investigation was made to evaluate mechanical properties of heated and unheated specimens. Results of experimental tests showed that induced micro-cracks significantly influence on the failure mode of specimens. The specimens kept at room temperature failed in the splitting mode, while the failure mode of specimens heated to $800^{\circ}C$ are shearing and the specimens heated to $1000^{\circ}C$ failed in the spalling mode. On the basis of AE monitoring, it is found that with increasing of the micro-crack density, the ratio of the number of shear cracks to the number of tensile cracks increases, under loading sequences.

Effects of Crack Velocity on Fracture Resistance of Concrete (콘크리트의 파괴저항에 대한 균열속도의 영향)

  • Yon, Jung-Heum
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.52-59
    • /
    • 2003
  • Tests of concrete CLWL-DCB specimens had been conducted with displacement-controlled dynamic loading. The crack velocities for 381mm crack extension were 0.80 mm/sec ~ 215m/sec. The external work and the kinetic and strain energies were derived from the measured external load and load-point displacement. The fracture resistance of a running crack was calculated from the fitted curves of the fracture energy required for the tests. The standard error of the fracture energy was less than 3.2%. The increasing rate of the fracture resistance for 28 mm initial crack extension or micro-cracking was relatively small, and then the slope of the fracture resistance increased to the maximum value at 90∼145 mm crack extension depending on crack velocity. The maximum fracture resistance remained for 185 mm crack extension, and then the faster crack velocity showed the faster decreasing rate of the maximum fracture resistance. The maximum fracture resistance increased proportionally to the logarithm of the crack velocity from 142 N/m to 217 N/m when the crack velocity was faster than 0.273 m/sec. The maximum fracture resistance of the fastest tests was similar to the average fracture energy density of 215 N/m. To measure the fracture resistance of concrete, the stable crack extension should be larger than 90∼145 mm depending on crack velocity.