• 제목/요약/키워드: micro dust

검색결과 71건 처리시간 0.021초

A Study on Environmental Micro-Dust Level Detection and Remote Monitoring of Outdoor Facilities

  • Kim, Seung Kyun;Mariappan, Vinayagam;Cha, Jae Sang
    • International journal of advanced smart convergence
    • /
    • 제9권1호
    • /
    • pp.63-69
    • /
    • 2020
  • The rapid development in modern industrialization pollutant the water and atmospheric air across the globe that have a major impact on the human and livings health. In worldwide, every country government increasing the importance to improve the outdoor air pollution monitoring and control to provide quality of life and prevent the citizens and livings life from hazard disease. We proposed the environmental dust level detection method for outdoor facilities using sensor fusion technology to measure precise micro-dust level and monitor in realtime. In this proposed approach use the camera sensor and commercial dust level sensor data to predict the micro-dust level with data fusion method. The camera sensor based dust level detection uses the optical flow based machine learning method to detect the dust level and then fused with commercial dust level sensor data to predict the precise micro-dust level of the outdoor facilities and send the dust level informations to the outdoor air pollution monitoring system. The proposed method implemented on raspberry pi based open-source hardware with Internet-of-Things (IoT) framework and evaluated the performance of the system in realtime. The experimental results confirm that the proposed micro-dust level detection is precise and reliable in sensing the air dust and pollution, which helps to indicate the change in the air pollution more precisely than the commercial sensor based method in some extent.

18F-FDG PET를 이용한 미세먼지 노출에 따른 쥐(rat)의 뇌 활성도 변화 (Changes in Brain Activity of Rats due to Exposure to Fine Dust Using 18F-FDG PET)

  • 조윤호;조규상;이왕희;최재호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.225-232
    • /
    • 2022
  • Fine dust threatens human health in various forms, depending on the particle size, such as by causing respiratory, cardiovascular, and brain diseases, after entering the body via the lungs. The aim of this study was to correlate fine dust exposure with changes in brain blood flow in Sprague Dawley rats by using micro-positron emission tomography and elucidate the possibility of developing cerebrovascular diseases caused by fine dust. The subjects were exposured to an average fine dust (particulate matter 2.5) of 206.2 ± 7.74 to ten rats four times a day, twice a day for 90 min. Before the experiment, they were maintained at NPO to the maximize the intake of 18F-fluorodeoxy glucose(18F-FDG) and minimize changes in the 18F-FDG biomass depending on the ambient environment and body temperature of the rats. PET images were acquired in the list mode 40 min after injecting 18F-FDG 44.4 MBq into the rats tail vein using a micro-PET scanner pre and post exposure to fine dust. We found that the whole brain level of 18F-FDG standardized uptake value in rats averaged 5.21 ± 0.52 g/mL pre and 4.22 ± 0.48 g/mL post exposure to fine dust, resulting in a statistically significant difference. Fine dust was able to alter brain activity after entering the body via the lungs in various forms depending on the particle size.

미세먼지 자동측정장비의 정확도 향상 방안 연구 (A Study on How to Improve the Accuracy of Automatic Micro Dust Measurement Equipment)

  • 조민철;김승호;나혜윤;김난희;조광운;배석진;이세행
    • 한국환경과학회지
    • /
    • 제31권5호
    • /
    • pp.447-456
    • /
    • 2022
  • This study was conducted to propose a way to increase the accuracy and precision of 𝛽-ray measurement equipment. Statistical processing results of equivalent evaluation data from 2016 to 2021 confirmed that the concentration of micro dust measured by 𝛽-ray measurement equipment was higher than that of micro dust sampler. According to quarterly data, it was confirmed that the data from the third quarter (July to September) showed a different trend from other periods, which is assumed to be due to weather conditions. This study indicates that automatic micro-dust measurement equipment evaluation at air pollution measuring stations during the third quarter should be excluded. The evaluation cycle should be changed from once every two years to quarterly. In addition, when the criterion for determining equivalence evaluation falls within the range of the slope and intercept values of the existing trend line, it is necessary to evaluate the R2 value together and reduce the slope from 0.9-1.1 to 0.9-1.0.

Chemical Transformation of Individual Asian Dust Particles Estimated by the Novel Double Detector System of Micro-PIXE

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권2호
    • /
    • pp.106-114
    • /
    • 2010
  • By the application of novel double detector system of micro-PIXE that can detect light elements (Z<14), we made an attempt to provide a thorough discussion on the aging processes of Asian dust (hereafter called "AD") particle by reaction with sea-slat. The elemental spectra and maps obtained from the microbeam radiation of micro-PIXE to individual AD particles were useful for fractionating AD particles into both internally and externally mixed particles. A spatial distribution of elements in a minute domain of single particle obtained by scanning the microbeam irradiation enabled us not only to estimate the chemical mixing state of individual AD particles but also to presume their aging processes in both ambient air and cloud. By calculating the normalized micro-PIXE net count of elements, it was possible to classify individual AD particles into three distinct groups (i.e., (1) Aging type 1: AD particle coated by the gaseous Cl evaporated by the reaction between artificial acids and sea salt; (2) Aging type 2: AD particle mixed with sea salt but no additional reaction with artificial acids; and (3) Non-aged type) A relatively high transformation rate (63.3-75.9%) was shown in large particles (greater than $5.1\;{\mu}m$ in diameter).

Physicochemical Characteristics of Single Asian Dust Storm Particles

  • Ma, Chang-Jin;Mikio kasahara;Hwang, kyung-Chul;Park, Kum-Chan;Park, Seong-Boo;Lee, Jeong-Joo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제16권E호
    • /
    • pp.29-38
    • /
    • 2000
  • For the detailed characterization of atmospheric aerosol, the analysis of single particle is highly valuable. In this study, to investigate the characteristics of single Asian dust storm particles, scanning electron microscope(SEM) coupled with and energy dispersive X-ray microanalyzer(EDX) and micro-PIXE were applied. Sampling was performed at Kyoto University located in Kyoto, Japan, in spring of 1999. Mass concentration during Asian dust storm events was higher roughly 3∼5 times than measured in the season of the highest concentration. Single particles were generally sharp-edged and irregular in shape and contained mostly crustal elements. Significant amount of S in coarse fraction was detected in individual particles. A large particles in coarse fraction existed as the mixture of soil components and S. A good agreement between the result of SEM-EDX analysis and that iof micro-PIXE analysis was obtained in this study.

  • PDF

다단입자채집기와 입자계수기 자료를 이용한 서울 에어러솔 밀도 계산 (Aerosol Density Determined Using Micro-orifice Uniform Deposit Impactor and Aerosol Dust Monitors Data at Seoul)

  • 김정은;이해영
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.298-304
    • /
    • 2010
  • In order to calculate the aerosol bulk densities of $PM_{1.0}$ and $PM_{10}$, aerosol mass and number concentrations were measured for the period of December 2008~April 2009. $PM_{1.0}$ and $PM_{10}$ mass concentrations were measured using a cascade impactor (Micro-Orifice Uniform Deposit Impactor, MOUDI) while their volume concentrations were calculated based on number concentrations from an environmental dust monitor (EDM). Normal aerosol size distribution fitting functions were retrieved for number size distribution since aerosols < $2.5{\mu}m$ were measured from the EDM. Strong correlation was found between $PM_{1.0}$ mass and volume concentrations obtained with a $R^2$ of 0.95. The calculated average bulk densities of $PM_{1.0}$ and $PM_{10}$ were $1.97{\pm}0.33g/cm^3$ and $2.15{\pm}0.18g/cm^3$, respectively.

Chemical Properties of the Individual Asian Dust Particles Clarified by Micro-PIXE Analytical System

  • Ma, Chang-Jin;Kang, Gong-Unn;Kasahara, Mikio;Tohno, Susumu
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권3호
    • /
    • pp.154-161
    • /
    • 2014
  • The present study was undertaken to evaluate the chemical characteristics of Asian dust (hereafter called "AD") particles with the aid of the most advanced micro-PIXE (Particle-induced X-ray emission) analytical technique. To this end, size-selected particles were sampled on a rural peninsula of Korea (Byunsan, 35.37N; 126.27E) during AD and non-AD periods in 2004. The coarse particle (> $2{\mu}m$) number density during an AD event were 170 times higher than those of the non-AD counterpart. The average net-count of silica in individual particles collected on AD event was roughly 11 times higher than that of non-AD counterpart. The X-ray net-counts of trace elements (Zn, Co, Mn, and V) were also considerably high in AD relative to the non-AD day. Particle classification based on the inter ratio analysis of elemental net-count suggests that a large portion of the coarse particles collected during AD event underwent chemical transformation to a certain degree. The visual interpretation of micro-PIXE elemental maps and elemental localization data in and/or on individual AD particles clarified the internal mixture of AD particles with sea-salt and artificial metallic particles.

자전거 이용자를 위한 일회용 미세먼지 마스크 디자인 연구 (A study of disposable micro dust-mask design for bicycle users)

  • 권준호
    • 디지털융복합연구
    • /
    • 제16권12호
    • /
    • pp.571-577
    • /
    • 2018
  • 자전거 이용자가 안경 및 선글라스를 쓴 상태에서 마스크를 착용 할 때 여러 가지 불편함을 호소한다. 본 논문은 이러한 불편함을 보완하여 자전거 라이더들에게 필요한 일회용 미세먼지 마스크를 개발하는데 그 목적이 있다. 미세먼지 마스크의 특성상 일회성 정전기 발생 섬유와 마스크의 형태적 문제로 연구범위를 제한하고 기존 미세먼지 마스크를 간결한 제작공정으로 디자인한다. 이렇게 개발된 일회용 미세먼지 마스크는 세로방향 접힘으로 입 앞 마스크 내 공간을 충분히 확보하였고 거친 숨에도 입에 닿지 않게 접힘 부위형태가 유지 되게 하여 답답함을 최소화 하였다. 코지지대에 유선형 스폰지를 부착하고 안면 볼 부위를 일반마스크 보다 2.5cm 정도의 확장하여 측면 밀착성을 높였다. 또한 기존에 없던 일회용 미세먼지 스카프 마스크를 제작하여 안면과 목 부위 자외선을 차단하고 밀착성 높은 미세먼지 마스크를 개발하였다.

부유 및 퇴적의 분체 조건이 화재폭발 특성에 미치는 영향 (Effect of Powder Condition on the Fire and Explosion Characteristics of Suspended and Deposited Dusts)

  • 한우섭;서동현;최이락;임진호
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.229-236
    • /
    • 2022
  • 동일 분체특성의 분진이 평균입경, 농도, 분진조건(부유 또는 퇴적) 변화에 따른 화재폭발 위험성을 조사하였다. 이를 위해 20L분진폭발시험장치, 열중량분석장치, 연소속도시험장치(UN시험법)를 사용하였다. 4종 분진(Sugar, Mg, Al, Zr)의 입경이 서로 다른 8개 분진 시료에 대하여 부유 분진의 폭발특성과 화염전파속도(FPV), 그리고 퇴적분진의 화염확산속도(FSV)를 조사하였다. 부유 분진 조건에서 Mg 및 Al 분진은 입경이 감소하면 폭발 위험성이 증가하였지만, Sugar는 입경 변화에 따른 폭발 위험성의 영향이 거의 나타나지 않았다. 부유 분진의 화염전파속도(FPV)는 마이크로 범위에서의 입경 변화보다 마이크로에서 나노로 입경이 감소하면 크게 증가하였다. 퇴적층의 화염확산속도(FSV)는 수평면(기울기 0°)보다 경사면(기울기 30°)에서 증가하는 경향을 나타냈으며, 경사면(기울기 30°) 퇴적층 조건에서는 상방 전파가 하방 전파보다 높게 나타났다.

Chemically Aged Asian Dust Particles Proven by Traditional Spot Test and the Most Advanced micro-PIXE

  • Ma, Chang-Jin;Tohno, Susumu;Kang, Gong-Unn
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권2호
    • /
    • pp.114-123
    • /
    • 2016
  • A change in chemical compositions of Asian dust (AD) particles can dramatically alter their optical properties, cloud-forming properties, and health effects. The present study was undertaken to evaluate this aging of AD particles by means of two complementary methods (i.e., the traditional spot test and the most advanced micro-PIXE analytical technique) for single particle analysis. Size-classified particles were sampled at the rural peninsula of Korea (Byunsan, 35.37N; 126.27E) during AD event and non-AD period in 2004. Sulfate was principally enriched on the particles in the size range of $7.65-10.85{\mu}m$ collected during AD event. The average number fraction of coarse particles ($>2.05{\mu}m$) containing chloride was 16.2% during AD event. Relatively low particles containing nitrate compared to those containing sulfate and chloride were found in AD event. Micro-PIXE elemental maps indicated that a large number of AD particles were internally mixed with man-made zinc. The highest peaks of EC and OC concentrations were appeared at $0.01-0.43{\mu}m$ particle aerodynamic diameter. High EC concentration in $PM_1$ was might be caused by the Saemangeum Seawall Project that was being conducted during our field measurement.