• 제목/요약/키워드: micro coil

검색결과 133건 처리시간 0.038초

선택적 유도가열을 사용한 사출금형의 국부가열기술 (Local Heating of an Injection Mold using Selective Induction Heating)

  • 도범석;박정민;엄혜주;박근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1119-1123
    • /
    • 2008
  • High-frequency induction is an efficient way to heat mold surface by electromagnetic induction in a noncontact procedure. It has been recently applied to the injection molding of thin-walled parts or micro/nano structures. Though the induction heating has an advantage in terms of its rapid-heating capacity on the mold surface, it still has difficulty in efficient mold temperature control due to the restriction of an induction coil design suitable for the given mold shape. The present study proposed a localized mold heating method by means of selective use of mold material. For localized induction heating, an injection mold composed of ferromagnetic material and paramagnetic material is used. The electromagnetic induction concentrates on the ferromagnetic material, from which we can selectively heat for the local mold elements. The feasibility of the proposed heating method is investigated through an experimental measurement in terms of the heating efficiency on the localized mold surface.

  • PDF

Electromagnetic Micro x-y Stage for Probe-Based Data Storage

  • Park, Jae-joon;Park, Hongsik;Kim, Kyu-Yong;Jeon, Jong-Up
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제1권1호
    • /
    • pp.84-93
    • /
    • 2001
  • An electromagnetic micro x-y stage for probe-based data storage (PDS) has been fabricated. The x-y stage consists of a silicon body inside which planar copper coils are embedded, a glass substrate bonded to the silicon body, and eight permanent magnets. The dimensions of flexures and copper coils were determined to yield $100{\;}\mu\textrm{m}$ in x and y directions under 50 mA of supplied current and to have 440 Hz of natural frequency. For the application to PDS devices, electromagnetic stage should have flat top surface for the prevention of its interference with multi-probe array, and have coils with low resistance for low power consumption. In order to satisfy these design criteria, conducting planar copper coils have been electroplated within silicon trenches which have high aspect ratio ($5{\;}\mu\textrm{m}$in width and $30{\;}\mu\textrm{m}$in depth). Silicon flexures with a height of $250{\;}\mu\textrm{m}$ were fabricated by using inductively coupled plasma reactive ion etching (ICP-RIE). The characteristics of a fabricated electromagnetic stage were measured by using laser doppler vibrometer (LDV) and dynamic signal analyzer (DSA). The DC gain was $0.16{\;}\mu\textrm{m}/mA$ and the maximum displacement was $42{\;}\mu\textrm{m}$ at a current of 180 mA. The measured natural frequency of the lowest mode was 325 Hz. Compared with the designed values, the lower natural frequency and DC gain of the fabricated device are due to the reverse-tapered ICP-RIE process and the incomplete assembly of the upper-sided permanent magnets for LDV measurements.

  • PDF

Comparison of the effects of horizontal and vertical micro-osteoperforations on the biological response and tooth movement in rabbits

  • Kim, Seok-gon;Kook, Yoon-Ah;Lim, Hee Jin;Park, Patrick;Lee, Won;Park, Jae Hyun;Bayome, Mohamed;Kim, Yoonji
    • 대한치과교정학회지
    • /
    • 제51권5호
    • /
    • pp.304-312
    • /
    • 2021
  • Objective: This study aimed to compare the amount of tooth movement after multiple horizontal (MH) and single vertical (SV) micro-osteoperforations (MOPs), and evaluate the histological changes after orthodontic force application in rabbits. Methods: The mandibles of 24 white rabbits were subjected to two experimental interventions: MH and SV MOPs. Defect volume of the MOPs between the two groups was kept similar. A force of 100 cN was applied via a coil spring between the incisor teeth and the first premolars. The amount of tooth movement was measured. Differences in the amount of tooth movement and bone variables at three time points and between the two groups were evaluated using repeated-measures analysis of variance. Results: The first premolar showed a mesial movement of 1.47 mm in the MH group and 1.84 mm in the SV group, which was significantly different at Week 3 (p < 0.05). No significant difference was observed in bone volume and bone fraction between the groups. Tartrate-resistant acidic phosphatase-positive cell count was also significantly greater at Week 3 than at Week 1 in both the SV and MH groups. Conclusions: The amount of tooth movement showed significant differences between Weeks 1 and 3 in the SV and MH MOP groups, but showed no differences between the two groups. Therefore, SV MOP could be considered an effective tool for enhancing tooth movement, especially for molar distalization, uprighting, and protraction to an edentulous area.

Effect of nicotine on orthodontic tooth movement and bone remodeling in rats

  • Lee, Sung-Hee;Cha, Jung-Yul;Choi, Sung-Hwan;Kim, Baek-il;Cha, Jae-Kook;Hwang, Chung-Ju
    • 대한치과교정학회지
    • /
    • 제51권4호
    • /
    • pp.282-292
    • /
    • 2021
  • Objective: To quantitatively analyze the effect of nicotine on orthodontic tooth movement (OTM) and bone remodeling in rats using micro-computed tomography and tartrate-resistant acid phosphatase immunostaining. Methods: Thirty-nine adult male Sprague-Dawley rats were randomized into three groups: group A, 0.5 mL normal saline (n = 9, 3 per 3, 7, and 14 days); group B, 0.83 mg/kg nicotine (n = 15, 5 per 3, 7, and 14 days); and group C, 1.67 mg/kg nicotine (n = 15, 5 per 3, 7, and 14 days). Each animal received daily intraperitoneal injections of nicotine/saline from the day of insertion of identical 30-g orthodontic force delivery systems. A 5-mm nickel-titanium closed-coil spring was applied between the left maxillary first molar (M1) and the two splinted incisors. The rate of OTM and volumetric bone changes were measured using micro-computed tomography. Osteoclasts were counted on the mesial alveolar bone surface of the distobuccal root of M1. Six dependent outcome variables, including the intermolar distance, bone volume fraction, bone mineral density, trabecular thickness, trabecular volume, and osteoclast number, were summarized using simple descriptive statistics. Nonparametric Kruskal-Wallis tests were used to evaluate differences among groups at 3, 7, and 14 days of OTM. Results: All six dependent outcome variables showed no statistically significant among group-differences at 3, 7, and 14 days. Conclusions: The findings of this study suggest that nicotine does not affect OTM and bone remodeling, although fluctuations during the different stages of OTM in the nicotine groups should be elucidated in further prospective studies.

Design of Torsion-typed Smooth Picture Actuator for DLP Projection TV

  • Moon, Yang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.564-568
    • /
    • 2006
  • Smooth picture module is operated by vibration to tilt the light from the DMD (digital micro mirror device) of DLP projection TV, which makes the screen of the TV smoother and DMD chip cost lower. To satisfy the vibration characteristics of smooth picture module, it is designed by optimizing moment of inertia, spring constant and damping coefficient, using structural and fluid dynamic simulation that showed a good agreement with experimental data. To reduce the material cost and moment of inertia, engineering plastic is used and the reliability is estimated. A VCM (voice coil motor) type actuator for smooth picture has to satisfy performance requirements such as higher driving force, lower power consumption, and lower cost. The initial design and optimization for VCM was performed using FE analysis. It allowed us to optimize the design of magnetic circuit of the proposed actuator to obtain higher force while maintaining a lower cost.

  • PDF

1칩 마이크로 프로세서를 이용한 He-Ne 레이저의 주파수 안정화 (Frequency Stabilization of He-Ne laser using One Chip Micro-Processor)

  • 최현승;엄태봉;이선규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.102-105
    • /
    • 2000
  • A simple digital control system has been developed for the frequency stabilization of an internal mirror He-Ne laser. The system is based on one chip microprocessor with embedded Basic interpreter. To stabilize the laser output frequency, the signal such as power difference or beat frequency between two modes is supplied and processed by a microprocessor, and control signal is fed to the heating coil would round the laser tube for adjusting the spacing of the laser cavity mirror. Newly developed frequency stabilization system is totally digitized. The system and the frequency stability performance are briefly described.

  • PDF

영구자석 이동형 선형 모터를 가진 초소형 공기베어링 스테이지 (A Miniature Air-Bearing Positioning Stage with a Magnet-Moving Linear Motor)

  • 노승국;박종권
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.89-96
    • /
    • 2007
  • In this paper, a new air bearing stage with magnetic preload and a linear motor has been developed for the small precision machine systems. The new air bearing stage is unique in the sense that permanent magnets attached bottom of the iron core of table are used not only for preloading air bearings in vertical direction but also for generating thrust force by current of the coil at base. The characteristics of air bearings using porous pads were analyzed with numerical method, and the magnetic circuit model was derived for linear motor for calculating required preload force and thrust force. A prototype of single axis miniature stage with size of $120(W){\times}120(L){\times}50(H)\;mm^3$ was designed and fabricated and examined its performances, vertical stiffness, load capacity, thrust force and positioning resolution.

단락 코일을 사용한 페아라이트 전자 지연선 (A Ferrite filled Electromagnetic Delay Line using Short-Circuited Coils)

  • 이병화;정선호
    • 대한전자공학회논문지
    • /
    • 제3권1호
    • /
    • pp.12-17
    • /
    • 1966
  • 전자 지연선에 대한 보다 깊은 이론적 해석이 본 논문 속에 제시되었고 n=0 mode 동작시 지연선의 특성을 개량하기 위하여 단락 coil을 사용하므로써 위상이 다른 전류가 상호 자속을 상살시키는 현상을 제거하고 결과적으로 단위 길이당 시간 지연을 증가시킬 수 있음을 이론적으로 입증하고 실험에 의하여 확인하였다. 직경이 3"/8이고 길이가 6"인 전자 지연선을 제작한 후 실험한 결과 10 micro sec/m의 시간 지연을 측정할 수 있었다. 이는 Onoda나 Katz가 얻은 결과보다 월등하게 우수하다고 생각한다. 또한 실제 설계자를 돕기 위하여 설계 공식을 집약하여 알기 쉽게 설명하였다.

  • PDF

지그재그 형태의 형상기억합금 스프링을 이용한 굽힘 액추에이터의 제작 (Fabrication of Bending Actuator using Zigzag-type Shape Memory Alloy Spring)

  • 임안수;이승기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.269-274
    • /
    • 1999
  • A bending actuator using zigzag type shape memory alloy springs has been fabricated and characterized. The fabricated millimeter-sized actuator has outer diameter of 3.0mm and inner diameter of 2.0mm. The zigzag type spring is more suitable for thin wall type actuator because the zigzag type spring has a planar structure comparing with the coil type spring which has a three-dimensional structure. The measured characteristics of the fabricated bending actuator show the possibility of practical application to micro active bending catheters.

  • PDF

Inter Landau Level Optical Absorption in Graphene Under Ultra-high Magnetic Field

  • Saito, H.;Nakamura, D.;Takeyama, S.;Kim, Yong-Min;An, K.S.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.360-360
    • /
    • 2012
  • Graphene shows diverse novel physical properties arising from its peculiar electronic states, so called Dirac electrons. Especially, effect of magnetic field is very unique, exhibiting exotic Landau level (LL) splitting. LLs are substantially modified by spins of Dirac electrons and pseudo-spins. The degeneracy of LLs is lifted to show splitting by electron-electron interaction and by the Zeeman effect. We investigated the magneto-optical absorption of graphene subjected to ultra-high magnetic field. Samples were prepared by the CVD method deposited on GaAs and Quart substrate. We have confirmed existence of graphene on each substrate by the micro-Raman spectroscopy. Next, we conducted magneto-absorption measurements in magnetic field up to 120 T by the single-turn coil (STC) method. We could observe absorption peak at 65 T and 100 T, respectively, probably arising from the LL inter-band transitions.

  • PDF