• Title/Summary/Keyword: method validation #5

Search Result 959, Processing Time 0.025 seconds

Validation on the Analytical Method of Ginsenosides in Red Ginseng

  • Cho B. G.;Nho K. B.;Shon H. J.;Choi K. J.;Lee S. K.;Kim S. C;Ko S. R.;Xie P. S.;Yan Y. Z.;Yang J. W.
    • Proceedings of the Ginseng society Conference
    • /
    • 2002.10a
    • /
    • pp.491-501
    • /
    • 2002
  • A cross-examination between KT&G Central Research Institute and Guangzhou Institute for Drug Control was carried out in order to select optimum conditions for extraction, separation and determination of ginsenosides in red ginseng and to propose a better method for the quantitative analysis of ginsenosides. The optimum extraction conditions of ginsenosides from red ginseng were as follows: the extraction solvent, $70\%$ methanol; the extraction temperature, $100^{\circ}C;$ the extraction time, 1 hour for once; and the repetition of extraction, twice. The optimum separation conditions of ginsenosides on the SepPak $C_{18}$ cartridge were as follows: the loaded amount, 0.4 g of methanol extract; the washing solvents, distilled water of 25 ml at first and then $30\%$ methanol of 25 ml; the elution solvent, $90\%$ methanol of 5 ml. The optimum HPLC conditions for the determination of ginsenosides were as follows: column, Lichrosorb $NH_2(25{\times}0.4cm,$ 5${\mu}m$, Merck Co.); mobile phase, a mixture of acetonitrile/water/isopropanol (80/5/15) and acetonitrile/water/isopropanol (80/20/15) with gradient system; and the detector, ELSD. On the basis of the optimum conditions a method for the quantitative analysis of ginsenosides were proposed and another cross-examination was carried out for the validation of the selected analytical method conditions. The coefficient of variances (CVs) on the contents of ginsenoside-$Rg_{1}$, -Re and $-Rb_1$ were lower than $3\%$ and the recovery rates of ginsenosides were $89.4\~95.7\%,$ which suggests that the above extraction and separation conditions may be reproducible and reasonable. For the selected HPLC/ELSD conditions, the CVs on the detector responses of ginsenoside-Rg, -Re and $-Rb_1$) were also lower than $3\%$, the regression coefficients for the calibration curves of ginsenosides were higher than 0.99 and two adjacent ginsenoside peaks were well separated, which suggests that the above HPLC/ELSD conditions may be good enough for the determination of ginsenosides.

  • PDF

Prediction of movie audience numbers using hybrid model combining GLS and Bass models (GLS와 Bass 모형을 결합한 하이브리드 모형을 이용한 영화 관객 수 예측)

  • Kim, Bokyung;Lim, Changwon
    • The Korean Journal of Applied Statistics
    • /
    • v.31 no.4
    • /
    • pp.447-461
    • /
    • 2018
  • Domestic film industry sales are increasing every year. Theaters are the primary sales channels for movies and the number of audiences using the theater affects additional selling rights. Therefore, the number of audiences using the theater is an important factor directly linked to movie industry sales. In this paper we consider a hybrid model that combines a multiple linear regression model and the Bass model to predict the audience numbers for a specific day. By combining the two models, the predictive value of the regression analysis was corrected to that of the Bass model. In the analysis, three films with different release dates were used. All subset regression method is used to generate all possible combinations and 5-fold cross validation to estimate the model 5 times. In this case, the predicted value is obtained from the model with the smallest root mean square error and then combined with the predicted value of the Bass model to obtain the final predicted value. With the existence of past data, it was confirmed that the weight of the Bass model increases and the compensation is added to the predicted value.

Vulnerability Assessment for Fine Particulate Matter (PM2.5) in the Schools of the Seoul Metropolitan Area, Korea: Part II - Vulnerability Assessment for PM2.5 in the Schools (인공지능을 이용한 수도권 학교 미세먼지 취약성 평가: Part II - 학교 미세먼지 범주화)

  • Son, Sanghun;Kim, Jinsoo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_2
    • /
    • pp.1891-1900
    • /
    • 2021
  • Fine particulate matter (FPM; diameter ≤ 2.5 ㎛) is frequently found in metropolitan areas due to activities associated with rapid urbanization and population growth. Many adolescents spend a substantial amount of time at school where, for various reasons, FPM generated outdoors may flow into indoor areas. The aims of this study were to estimate FPM concentrations and categorize types of FPM in schools. Meteorological and chemical variables as well as satellite-based aerosol optical depth were analyzed as input data in a random forest model, which applied 10-fold cross validation and a grid-search method, to estimate school FPM concentrations, with four statistical indicators used to evaluate accuracy. Loose and strict standards were established to categorize types of FPM in schools. Under the former classification scheme, FPM in most schools was classified as type 2 or 3, whereas under strict standards, school FPM was mostly classified as type 3 or 4.

Analytical Method Validation of Quercetin in Changnyeong Onion Extract as a Functional Ingredient for Functional Health Food (건강기능식품 기능성원료로서 창녕양파추출액의 지표성분 Quercetin 분석법)

  • Jeon, Seon-Young;Jeong, Eun-Jeong;Baek, Jeong-Hwa;Cha, Yong-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.4
    • /
    • pp.565-569
    • /
    • 2011
  • Validation of quercetin as a marker compound in the standardization of Changnyeong onion extract developed for functional health food was attempted by analytical method. The specificity was satisfied with retention time and photo diode array (PDA) spectrum by analysis of quercetin using HPLC and comparison with standard compound. It showed a high linearity in the calibration curve as coefficient of correlation ($R^2$) of 0.9986, and the limit of detection (LOD) and limit of quantitation (LOQ) were 0.2 mg/L and 0.5 mg/L, respectively. Recovery rate test with quercetin concentration of 0.05, 0.075 and 0.1 mg/mL was revealed in the high range of 82.36~95.26%, 82.70~98.24% and 87.91~95.11%, respectively. The intra-day and inter-day precision in quercetin for Changnyeong onion extracts was 0.10~3.28% and 0.96~5.79%, respectively. Therefore, application of quercetin was validated in analytical method as a marker compound in Changnyeong onion extracts.

Effective Diagnostic Method Of Breast Cancer Data Using Decision Tree (Decision Tree를 이용한 효과적인 유방암 진단)

  • Jung, Yong-Gyu;Lee, Seung-Ho;Sung, Ho-Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.57-62
    • /
    • 2010
  • Recently, decision tree techniques have been studied in terms of quick searching and extracting of massive data in medical fields. Although many different techniques have been developed such as CART, C4.5 and CHAID which are belong to a pie in Clermont decision tree classification algorithm, those methods can jeopardize remained data by the binary method during procedures. In brief, C4.5 method composes a decision tree by entropy levels. In contrast, CART method does by entropy matrix in categorical or continuous data. Therefore, we compared C4.5 and CART methods which were belong to a same pie using breast cancer data to evaluate their performance respectively. To convince data accuracy, we performed cross-validation of results in this paper.

Comparative study on cracked beam with different types of cracks carrying moving mass

  • Jena, Shakti P.;Parhi, Dayal R.;Mishra, Devasis
    • Structural Engineering and Mechanics
    • /
    • v.56 no.5
    • /
    • pp.797-811
    • /
    • 2015
  • An analytical-computational method along with finite element analysis (FEA) has been employed to analyse the dynamic behaviour of deteriorated structures excited by time- varying mass. The present analysis is focused on the comparative study of a double cracked beam with inclined edge cracks and transverse open cracks subjected to traversing mass. The assumed computational method applied is the fourth order Runge-Kutta method. The analysis of the structure has been carried out at constant transit mass and speed. The response of the structure is determined at different crack depth and crack inclination angles. The influence of the parameters like crack depth and crack inclination angles are investigated on the dynamic behaviour of the structure. The results obtained from the assumed computational method are compared with those of the FEA for validation and found good agreements with FEA.

Isolation of Constituents of Lihtospermum erythrorhizon and Development of an Analytical Method of its Constituents by HPLC-UV (자근의 성분 분리 및 이들 성분의 HPLC-UV 동시분석법 개발)

  • Hong, Eun-Young;Kyung, Min-Ji;Whang, Wan-Kyunn
    • YAKHAK HOEJI
    • /
    • v.59 no.5
    • /
    • pp.222-229
    • /
    • 2015
  • Lithospermi radix, the dried roots of Litospermum erythrorhizon Sieboid et Zuccarini (Boraginaceae), has long been used to treat detoxification and inflammation. In this study, we isolated two main quinoid compounds, ${\beta}$-hydroxyisovalerylshikonin (1) and acetylshikonin (2) from L. erythrorhizon. As acetylshikonin is considered as a marker compound of L. erythrorhizon, a rapid analysis method for the simultaneous determination of quinoid compounds including 2 was also developed by HPLC (High Performance Liquid Chromatography) and validation of this analytical method. By the developed method, two quinoid marker compounds (${\beta}$-hydroxyisovalerylshikonin and acetylshikonin) were successfully quantified in 31 commercial samples which were collected from different regions. The contents were 0.20% (${\beta}$-hydroxyisovalerylshikonin) and 0.22% (acetylshikonin), respectively.

Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

  • Yang, Jeong Soo;Cho, Eun Gi;Huh, Wooseong;Ko, Jae-Wook;Jung, Jin Ah;Lee, Soo-Youn
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2425-2430
    • /
    • 2013
  • A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water-5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL ($R^2$ > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

A Comparison Study on Statistical Modeling Methods (통계모델링 방법의 비교 연구)

  • Noh, Yoojeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.645-652
    • /
    • 2016
  • The statistical modeling of input random variables is necessary in reliability analysis, reliability-based design optimization, and statistical validation and calibration of analysis models of mechanical systems. In statistical modeling methods, there are the Akaike Information Criterion (AIC), AIC correction (AICc), Bayesian Information Criterion, Maximum Likelihood Estimation (MLE), and Bayesian method. Those methods basically select the best fitted distribution among candidate models by calculating their likelihood function values from a given data set. The number of data or parameters in some methods are considered to identify the distribution types. On the other hand, the engineers in a real field have difficulties in selecting the statistical modeling method to obtain a statistical model of the experimental data because of a lack of knowledge of those methods. In this study, commonly used statistical modeling methods were compared using statistical simulation tests. Their advantages and disadvantages were then analyzed. In the simulation tests, various types of distribution were assumed as populations and the samples were generated randomly from them with different sample sizes. Real engineering data were used to verify each statistical modeling method.

Optimization of Extraction Conditions for Swertiamarin in Swertia japonica Makino (당약의 swertiamarin 분석을 위한 추출조건 최적화)

  • Kim, Tae Hee;Jang, Seol;Lee, Ah Reum;Lee, A Young;Choi, Goya;Kim, Ho Kyoung
    • The Korea Journal of Herbology
    • /
    • v.29 no.1
    • /
    • pp.13-18
    • /
    • 2014
  • Objectives : Iridoid glycoside, swertiamarin is a well known bioactive component found in Swertia japonica Makino (SJ). In this study, we tried to optimize a suitable method which would extract swertiamarin effectively. Methods : Extraction of SJ was carried out by various conditions of time (5 - 60 min), temperature ($30-70^{\circ}C$), solvent (from non-polar to polar), and ratio of solvnet / sample (10 : 1 - 40 : 1) using ultrasonic extractor. Swertiamarin in SJ extracts was quantified by high performance liquid chromatography - Phtodiode array detector (HPLC-PDA) using C18 column and the analytical procedure was validated by evaluation of specificity, range, linearity, accuracy (recovery), precision (intra- and inter day variability), limit of detection (LOD), and limit of quantification (LOQ). Results : An efficient extraction condition for swertiamarin in SJ was optimized using sonicator extraction (temperature $40^{\circ}C$, solvent 20% methanol, solvent / sample (20 : 1), and time 10 min. Analytical procedure was optimized by HPLC-PDA using isocratic solvent system of acetonitrile and water (9 : 91), and the method was validated in regard to linearity (correlation coefficient, $R^2$ > 0.9999), range ($50-1000{\mu}g/mL$), intra- and inter-precision (RSD < 5.0 %), and recovery (99 -103 %). LOD and LOQ were 0.051 and $0.155{\mu}g/mL$, respectively. Conclusion : An optimized method of extraction for swertiamarin in SJ was established through conditions of diverse extraction and the validation result indicated that the method is suited for the determination of swertiamarin in SJ.