Search Result 74, Processing Time 0.027 seconds

Establishment of Remote Monitoring System for Wind Turbine Test Sites Based on Hierarchical Architecture (계층적 구조를 갖는 풍력발전 실증단지 원격 풍황 모니터링 시스템 구축)

  • Cho, Byung-Ha;Lee, Jeong-Wan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.9
    • /
    • pp.81-87
    • /
    • 2009
  • In this paper, remote monitoring system for wind turbine site is developed. This system is a hierarchical reliable monitoring system connected by wireless communication channels between monitoring host computer and modular slave measuring subsystems. The design of this systems; the slave measuring subsystems is placed in meteorological tower and wind turbine, and the supervisory host computer is in the safety zone. The slave measuring subsystems signals are from a meteorological tower, wind turbine generator and tower. For monitoring and command function, the supervisory computer is implemented with a PC using graphic user interface. This system can be transferred the information among host computer and remote computers through the Ethernet. Consequently we can get reliability but economic system. The system has the concept of universality and modularity, so it is simple and easy to implement in wind turbine test sites.

A Development of Modular Monitoring System for Wind Turbine Test Site (풍력 실증단지를 위한 분산 형 모니터링 시스템 개발)

  • Lee Jeong Wan;Yoo Neung Soo;Nam Yoon Su;Cho Byung Ha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.9-12
    • /
    • 2005
  • In this paper. we offer a new monitoring system that controls all of the windfar. it can also apply use general wind turbine systems and real meteorological tower. We propose a hierarchical releiable monitoring system connected by wireless communication channels between monitoring host computer and modular slave measuring subsystems. Our system has two hierarchical subsystems: slave measuring systems, and supervisory host computer. We design and implement that the slave measuring subsystems is placed in meteorological tower and wind turbines, and the supervisory host computer in safety zone, The micro-controller in slave measuring system is duplicated using cold-standby method for reliability. The host computer and slave system constructs a feedback system, with wireless communication channel between them. For monitoring and command function, the supervisory computer is implemented with a Personal Computer using graphic user interface. Consequently. we can get a reliable but economic system.

  • PDF

A Technique for Alignment to True North Based on Camera in Meteorological Installation (풍황 계측 타워 설치시 카메라를 사용한 진북 맞추기 기법)

  • Yoo Neung Soo;Nam Yoo Su;Lee Jeong Wan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.2
    • /
    • pp.122-126
    • /
    • 2005
  • A technique for alignment to true north is presented based on synchronized measurements of vision image by a camera and output voltage of wind direction sensor. The true wind direction is evaluated by means of image processing techniques with least square sense, and then evaluated true value is compared with measured output voltage of the sensor. The uncertainty analysis about the component error for the proposed method in practical situation is performed. The proposed technique is applied to real meteorological tower (wind measuring tower) at the Daekwanryung test site. In addition, some uncertainty analysis of this method is presented.

Assessment of Outgoing Longwave Radiation using COMS : Cheongmi and Sulma Catchments (천리안 위성을 사용한 방출장파복사량 검증 : 청미천, 설마천)

  • Baek, Jong Jin;Sur, Chanyang;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.5
    • /
    • pp.465-476
    • /
    • 2013
  • The outgoing longwave radiation (Rlu) for estimation of evapotranspiration is essential to understand energy balance of earth. However, the ground measurement based Rlu has a limitation that the observation can just stand for the exact site, not for an area. In this study, remote sensing technique is adopted to compensate the limitation of ground observation using the geostationary satellite. We calculated Rlu using Communication, Ocean and Meteorological Satellite (COMS). We validated Rlu from COMS with Cheongmicheon (CFK) and Sulmacheon (SMK) flux tower observations controlled by Hydrological Survey Center. The results showed that Rlu from COMS represented reasonable correlation with ground based measurement. Based on the results in this study, COMS will be able to be used for estimation of evapotranspiration.

Characterization of the wind-induced response of a 356 m high guyed mast based on field measurements

  • Zhe Wang;Muguang Liu;Lei Qiao;Hongyan Luo;Chunsheng Zhang;Zhuangning Xie
    • Wind and Structures
    • /
    • v.38 no.3
    • /
    • pp.215-229
    • /
    • 2024
  • Guyed mast structures exhibit characteristics such as high flexibility, low mass, small damping ratio, and large aspect ratio, leading to a complex wind-induced vibration response mechanism. This study analyzed the time- and frequency-domain characteristics of the wind-induced response of a guyed mast structure using measured acceleration response data obtained from the Shenzhen Meteorological Gradient Tower (SZMGT). Firstly, 734 sets of 1-hour acceleration samples measured from 0:00 October 1, 2021, to 0:00 November 1, 2021, were selected to study the vibration shapes of the mast and the characteristics of the generalized extreme value (GEV) distribution. Secondly, six sets of typical samples with different vibration intensities were further selected to explore the Gaussian property and modal parameter characteristics of the mast. Finally, the modal parameters of the SZMGT are identified and the identification results are verified by finite element analysis. The findings revealed that the guyed mast vibration shape exhibits remarkable diversity, which increases nonlinearly along the height in most cases and reaches a maximum at the top of the tower. Moreover, the GEV distribution characteristics of the 734 sets of samples are closer to the Weibull distribution. The probability distribution of the structural wind vibration response under strong wind is in good agreement with the Gaussian distribution. The structural response of the mast under wind loading exhibits multiple modes. As the structural response escalates, the first three orders of modal energy in the tower display a gradual increase in proportion.

A study on performance test of water heat storage type heat-pump system using cooling tower heat source (냉각탑을 이용한 축열식 히트펌프시스템의 성능측정에 관한 연구)

  • Lee, Sang-Hoon;Park, Hyo-Sik;Han, Woo-Yong;Kim, Uk-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1099-1104
    • /
    • 2008
  • Recent year, mean energy consumptions of a people are higher than other country. And international oil price became over 120 dollar. This energy environment as well as energy war. Maybe, the Meteorological Administration is going to enforce scorching heatwave special report system from that come summer. Besides, 2008 summer, maximum demand power is expected by 64,240,000kW. The electric power equipment reserve rate appeared in to keep 12.5% level. Chilled water storage system witch is one of electric load administration system. Heat pump system used cooling tower heat recovery is advantage that use is possible to summer in small a public bath building. In this paper, we suggest that heat pump system by heat recovery using cooling tower when it is heating operation of ambient air temperature. To apply cooling tower heat recovery heat pump to chilled water heat storage type and achieved performance evaluation about operation. As a result, performance of heat pump system that about 121% in cooling mode, 138% in heating mode higher than KEPCO standard. And heating operation possible to ambient air temperature about $23^{\circ}C$, which of appear cooling tower outlet temperature about $13^{\circ}C$.

  • PDF

Observation on Structural Change of Low Level Atmosphere due to Effect of Sea Breeze (해풍 효과에 의한 저층대기구조 변화의 측정)

  • 전병일;김유근
    • Journal of Environmental Science International
    • /
    • v.5 no.4
    • /
    • pp.441-451
    • /
    • 1996
  • The surface meteorological and upper layer meteorological observation carried out to investigate influences of sea breeze effect on lower layer atmosphere at Gori nuclear power plant for 29∼30 July, 1996. According to surface meteorological data, the inflow of sea breeze was occurred 11:30 on 29 July, 10:30-on 30 July, respectively, at observation site. And the meteorological tower data showed that wind direction of sea breeze was identified as south-westerly, and wind speed of 58 m was 2 times stronger than that of 10 m. It is notworthy that surface inversion layer which built from the night time to daybreak of next day was not broken off by seab reeze's inflow for daytime, and strong inversion layer observed at 47∼243 m with moderately stable class (F) by URC. It was found that strong stable layer of potential temperature appeared at that layer, maximum relative humidity observed at the bottom of inversion layer and maximum mixing ratio observed in the low of inversion layer.

  • PDF

Dynamic Behavior Analysis of Floating Offshore Wind Turbine Including Flexible Effects of Tower and Blade (타워와 블레이드의 탄성효과를 고려한 부유식 해상풍력발전기의 동적거동해석)

  • Jung, Hye-Young;Sohn, Jeong-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.8
    • /
    • pp.905-911
    • /
    • 2012
  • To establish a floating offshore wind turbine simulation model, a tension leg platform is added to an onshore wind turbine. The wind load is calculated by using meteorological administration data and a power law that defines the wind velocity according to the height from the sea surface. The wind load is applied to the blade and wind tower at a regular distance. The relative Morison equation is employed to generate the wave load. The rated rotor speed (18 rpm) is applied to the hub as a motion. The dynamic behavior of a 2-MW floating offshore wind turbine subjected to the wave excitation and wind load is analyzed. The flexible effects of the wind tower and the blade are analyzed. The flexible model of the wind tower and blade is established to examine the natural frequency of the TLP-type offshore wind turbine. To study the effect of the flexible tower and blade on the floating offshore wind turbine, we modeled the flexible tower model and flexible tower-blade model and compared it with a rigid model.

The Development of the Monitoring System for Wind resource measurement in onshore wind energy experimental research complex (육상풍력실증연구단지 풍황계측 모니터링 시스템 개발)

  • Ko, Seok-Whan;Jang, Moon-Seok;Lee, Youn-Seop
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.277-280
    • /
    • 2009
  • Wind monitoring system is an absolutely-required system for assessing a performance and fatigue load of the wind energy generator in an on-shore wind energy experimental research complex. It was implemented for the purpose of monitoring the wind information measured from a meteorological tower at the monitoring house and of utilizing the measured data for the performance assessment, by using the LabVIEW program. Then, by adding the performance assessment-related data acquired from the wind energy generator during the performance assessment and the data recorder for synchronizing the data of meteorological tower, the system was implemented. Because it transmitted the data by converting the output 'RS-232' of data logger which measures the wind condition into CAN protocol, the data error rate was minimized, This paper is intended to explain the developed wind data monitoring system.

  • PDF

The Development of the Monitoring System for Power performance using the Lab View (LabView를 이용한 풍력발전 성능평가용 모니터링 시스템 개발)

  • Ko, Seok-Whan;Jang, Moon-Seok;Ju, Young-Chul;Lee, Yoon-Sub
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.69-74
    • /
    • 2009
  • Monitoring system is an absolutely-required system for assessing a performance and fatigue load of the wind turbine in an on-shore wind energy experimental research complex. It was implemented for the purpose of monitoring the wind information measured from a meteorological tower at the monitoring house, and of utilizing the measured data(fatigue data and electric analyzing data of wind turbine)for the performance assessment, by using the LabVIEW program. Then, by adding the performance assessment-related data acquired from the wind turbine during the performance assessment and the data recorder for synchronizing the data of meteorological tower, the system(BusDAQ) was implemented. Because it transmitted the data by converting the output 'RS-232' of data logger which measures the wind condition into CAN protocol, the data error rate was minimized. Also, This paper is introduced to make the best use of the developed monitoring system and to explain about construct of the system and detailed data communication of its system.