• 제목/요약/키워드: meteorological instrument

검색결과 63건 처리시간 0.032초

시정과 습도 관측자료를 이용한 자동 현천 관측 정확도 향상 연구 (Improvement of Automatic Present Weather Observation with In Situ Visibility and Humidity Measurements)

  • 이윤상;최규용;김기훈;박성화;남호진;김승범
    • 대기
    • /
    • 제29권4호
    • /
    • pp.439-450
    • /
    • 2019
  • Present weather plays an important role not only for atmospheric sciences but also for public welfare and road safety. While the widely used state-of-the-art visibility and present weather sensor yields present weather, a single type of measurement is far from perfect to replace long history of human-eye based observation. Truly automatic present weather observation enables us to increase spatial resolution by an order of magnitude with existing facilities in Korea. 8 years of human-eyed present weather records in 19 sites over Korea are compared with visibility sensors and auxiliary measurements, such as humidity of AWS. As clear condition agrees with high probability, next best categories follow fog, rain, snow, mist, haze and drizzle in comparison with human-eyed observation. Fog, mist and haze are often confused due to nature of machine sensing visibility. Such ambiguous weather conditions are improved with empirically induced criteria in combination with visibility and humidity. Differences between instrument manufacturers are also found indicating nonstandard present weather decision. Analysis shows manufacturer dependent present weather differences are induced by manufacturer's own algorithms, not by visibility measurement. Accuracies of present weather for haze, mist, and fog are all improved by 61.5%, 44.9%, and 26.9% respectively. The result shows that automatic present weather sensing is feasible for operational purpose with minimal human interactions if appropriate algorithm is applied. Further study is ongoing for impact of different sensing types between manufacturers for both visibility and present weather data.

GPS 가강수량 산출을 위한 최소 관측세션 지속시간에 대한 분석 (An Analysis of the Least Observing-Session Duration of GPS for the Retrieval of Precipitable Water Vapor)

  • 김유준;한상옥;김기훈;김선정;김건태;김병곤
    • 대기
    • /
    • 제24권3호
    • /
    • pp.391-402
    • /
    • 2014
  • This study investigated the performances of precipitable water vapor (PWV) retrieval from the sets of ground global positioning system (GPS) signals, each of which had different length of observing-session duration, for the purpose of obtaining as short session duration as possible that is required at the least for appropriate retrieval of the PWV for meteorological usage. The shorter duration is highly desirable to make the most use of the GPS instrument on board the mobile observation vehicle making measurements place by place. First, using Bernese 5.0 software the PWV retrieval was conducted with the data sets of GPS signals archived continuously in 30 seconds interval during 2-month period of January and February, 2012 at Bukgangneung site. Each of the PWVs produced independently using different session durations was compared to that of radio-sonde launched at the same GPS location, a Bukgangneung site. Second, the same procedure was done using the data sets obtained from the mobile observation vehicle that was operating at Boseong area in Jeonnam province during Changma observation campaign in 2013, and the results were compared to that at Bukgangneung site. The results showed that as the observing-session duration increased the retrieval errors decreased with the dramatic change happening between 3 and 4 hours of the duration. On average, the root mean square error (RMSE) of the retrieved PWV was around 1 mm for the durations of greater than 4 hours. The results at both the Bukgangneung (fixed site) and Boseong (mobile vehicle) seemed to be fairly comparable with each other. From this study it is believed that at least 4 hours of observing-session duration is needed for the retrieval of PWV from the ground GPS for meteorological usage using Bernese 5.0 software.

Testing and Adjustment for Inhomogeneity Temperature Series Using the SNHT Method

  • Lee, Yung-Seop;Kim, Hee-Kyung;Lee, Jung-In;Lee, Jae-Won;Kim, Hee-Soo
    • 응용통계연구
    • /
    • 제25권6호
    • /
    • pp.977-985
    • /
    • 2012
  • Data quality and climate forecasting performance deteriorates because of long climate data contaminated by non-climatic factors such as the station relocation or new instrument replacement. For a trusted climate forecast, it is necessary to implement data quality control and test inhomogeneous data. Before the inhomogeneity test, a reference series was created by $d$ index to measure the temperature series relationship between the candidate and surrounding stations. In this study, a inhomogeneity test to each season and climatological station was performed on the daily mean temperatures, daily minimum temperatures and daily maximum temperatures. After comparing two inhomogeneity tests, the traditional and the adjusted SNHT method, we found the adjusted SNHT method was slightly superior to the traditional one.

달 관측 영상을 이용한 천리안위성 기상탑재체 가시채널 검출기의 성능감쇄 분석 (Degradation Monitoring of Visible Channel Detectors on COMS MI Using Moon Observation Images)

  • 서석배;진경욱
    • 대한원격탐사학회지
    • /
    • 제29권1호
    • /
    • pp.115-121
    • /
    • 2013
  • 천리안위성은 대한민국에서 개발한 최초의 정지궤도위성으로 궤도상 시험을 완료하고 통신, 해양, 기상임무에 대한 정상운영을 수행하고 있으며, 천리안위성의 기상탑재체는 지구 및 주변의 가시채널 및 적외채널 영상을 취득하고 있다. 본 논문에서는 천리안위성 가시채널 검출기의 성능 분석방법을 설명하고, 2년의 운영기간동안 성능 분석결과를 설명한다. 가시채널 검출기의 성능은 검출기에서 취득한 결과 및 ROLO 모델 기반의 결과를 이용해서 계산할 수 있으며, 분석을 통해서 검출기의 성능은 정상임을 확인하였다.

항공기를 이용한 온실가스 CO2와 CH4의 연속관측: 안면도 겨울철 연직분포사례 분석 (Airborne In-situ Measurement of CO2 and CH4 in Korea: Case Study of Vertical Distribution Measured at Anmyeon-do in Winter)

  • 이선란;구태영;문혜진;;;오영석;이해영;변영화
    • 대기
    • /
    • 제29권5호
    • /
    • pp.511-523
    • /
    • 2019
  • A new Korean Meteorological Administration (KMA) airborne measurement platform has been established for regular observations for scientific purpose over South Korea since late 2017. CRDS G-2401m analyzer mounted on the King Air 350HW was used to continuous measurement of CO2, CH4 and CO mole fraction. The total uncertainty of measurements was estimated to be 0.07 ppm for CO2, 0.5 ppb for CH4, and 4.2 ppb for CO by combination of instrument precision, repeatability test simulated in-flight condition and water vapor correction uncertainty. The airborne vertical profile measurements were performed at a regional Global Atmosphere Watch (GAW) Anmyeon-do (AMY) station that belongs to the Total Carbon Column Observing Network (TCCON) and provides concurrent observations to the Greenhouse Gases Observing Satellite (GOSAT) overpasses. The vertical profile of CO2 shows clear altitude gradient, while the CH4 shows non-homogenous pattern in the free troposphere over Anmyeon-do. Vertically averaged CO2 at the altitude between 1.5 and 8.0km are lower than AMY surface background value about 7 ppm but higher than that observed in free troposphere of western pacific region about 4 ppm, respectively. CH4 shows lower level than those from ground GAW stations, comparable with flask airborne data that was taken in the western pacific region. Furthermore, this study shows that the combination of CH4 distribution in free troposphere and trajectory analysis, taking account of convective mixing, is a useful tool in investigating CH4 transport processes from tropical region to Korean region in winter season.

자동배수형 무게식 강수량계 개발 및 강우량 측정 성능검사 (Development of Auto-Empting Type Weighing Precipitation Gauge and Performance Test on Rainfall Measurement)

  • 김상조;손탑
    • 대기
    • /
    • 제22권2호
    • /
    • pp.279-285
    • /
    • 2012
  • The weighing precipitation gauge with auto-empting capability was developed in the R&D project organized by the Research Agency for Climate Science (RACS) and supported by the Korea Meteorological Administration (KMA). This project was initiated in line with the KMA's plan executed since 2010 to introduce the weighing precipitation gauges partly into of their Automatic Weather Station (AWS) network in order to upgrade the quality of precipitation data. The innovative feature of this research is that the auto-empting in weighing precipitation gauge is realized by abrupt rotation of receiving container. The prototype was tested in compliance with the relevant standards of KMA. The results of performance test on rainfall measurement in laboratory verified that the accuracies for 20 mm and 100 mm reference rainfall amount were 0.1 mm and 0.4 mm, respectively in both conditions of auto-empting and no-empting. During the rotation of container for auto-empting, the data was extrapolated smoothly by applying the same precipitation intensity of the previous 10 sec. Consequently, it was found that the auto-empting precipitation gauge developed in this research is quite enough to be used for the operational purpose of accurate measurement with 0.1 mm resolution, regardless of the precipitation intensity.

강릉 지역에서 자동 전운량 장비와 GWNU 태양 복사 모델을 이용한 지표면 일사량 분석 (An Analysis of Global Solar Radiation using the GWNU Solar Radiation Model and Automated Total Cloud Cover Instrument in Gangneung Region)

  • 박혜인;조일성;김부요;지준범;이규태
    • 한국지구과학회지
    • /
    • 제38권2호
    • /
    • pp.129-140
    • /
    • 2017
  • 이 연구에서는 지표 관측 자료와 위성 자료 그리고 GWNU 단층 복사 모델을 이용하여 맑은 상태의 전천 일사량을 계산하였으며, 전운량에 따라 관측 및 모델의 일사량 값을 비교 분석하였다. 연구 자료는 2012년 강릉원주대학교 복사 관측소의 전천 일사량, 기온, 기압, 습도, 에어로졸 등의 관측 자료와 OMI 센서의 오존전량 자료 그리고 구름의 유무 및 전운량을 판단하기 위하여 자동 전운량 장비인 Skyview 자료를 이용하였다. 전운량이 0 할인 맑은 날의 경우 관측 값과 모델 값이 0.98로 높은 상관계수를 나타내었으나 RMSE가 $36.62Wm^{-2}$로 비교적 높게 나타났다. 이는 Skyview 장비가 얇은 구름이나 박무 및 연무 등의 기상상태를 판단하지 못하였기 때문이다. 흐린 날의 경우 구름의 영향을 보정하기 위해 전운량과 두 값의 차에 대한 비율을 이용한 회귀식을 복사 모델에 적용하였으며, 장비의 오탐지를 제외한 경우 상관계수가 0.92로 높은 상관성을 보였으나 RMSE가 $99.50Wm^{-2}$으로 높은 값을 보였다. 더 정확한 분석을 위해서는 직달 성분의 차폐 유무 및 구름 광학 두께를 포함한 다양한 구름 요소의 추가적인 분석이 요구된다. 이 연구결과는 분 또는 시간에 따른 일사량을 산출하여 일사량이 관측되지 않는 지역에서 유용하게 사용될 수 있다.

TRMM/PR 자료와 지상 레이더와의 비교 (Comparison between TRMM/PR and Ground-Based Radar)

  • 하경자;오현미;서애숙;김정희
    • 한국지리정보학회지
    • /
    • 제5권4호
    • /
    • pp.1-8
    • /
    • 2002
  • TRMM/PR (Tropical Rainfall Measuring Mission/Precipitation Radar)과 기상청의 C-band 도플러 레이더(제주, 군산, 부산)의 비교는 지상 레이더의 검증을 위해서 이루어졌다. 검증에 사용된 사례는 2000년 하계에 TRMM이 한반도 남부, 약 $36^{\circ}N$ 이남을 지나갈 때 강한 강수가 있는 날을 선택하였다. 서로 view angle, bandwidths와 주파수가 다른 두 개의 레이더를 정량적으로 비교하는 것은 어려운 문제이다. 본 연구에서는 이를 해결하기 위해서 지상 레이더와 TRMM/PR을 동일한 격자로 만들어 동일 영역에서 비교하였다. 지상 레이더로부터 관측된 반사도는 PR에 의해 관측된 반사도에 비해 4-9dBZ정도 낮은 것으로 밝혀졌으며 이는 기계적인 성능이나 지형과 같은 많은 이유에 의해서 발생할 수 있다. 세 개의 지상 레이더 사이트 모두에서 TRMM과 비교하여 30dBZ 이상에서 RMSE가 가장 높게 나타나서 강한 에코를 지상레이더가 잘 관측하지 못하는 것을 알 수 있었다.

  • PDF

기상계측시스템을 위한 풍향.풍속모듈 및 DSP 센서 인터페이스시스템 설계 (The Design of a Wind Speed & Direction Module and a DSP Sensor Interface System for the Meteorological System)

  • 송도호;주재훈;옥기태;김상갑;최중경
    • 한국정보통신학회논문지
    • /
    • 제11권8호
    • /
    • pp.1478-1485
    • /
    • 2007
  • 본 논문에서는 풍향 풍속 계측모듈 및 DSP 센서인터페이스 회로 보드를 포함하는 기상계측 시스템을 제안한다. 이 DSP 시스템은 풍향풍속모듈, 대기압센서, 대기 온도 센서의 정보를 받아들이고, 빠르게 처리하여 PC 모니터링 시스템에 전달한다. 특히 풍향 풍속 모듈과 DSP 하드웨어는 직접 설계하여 적용한다. 풍향 풍속 모듈은 바람에 관한 벡터적 정보를 얻기 위해 4개의 박막형 RTD(Resistive Temperature Detectors) 저항센서를 히팅 코일에 의해 일정하게 가열된 원기둥 모양의 지지 표면에 벡터적으로 배치하는 구조를 채택한다. 이 구조를 채택한 계측 모듈은 진동, 습기, 부식 등에 강인하면서 정확한 계측을 가능케 한다. 센서 신호처리 회로는 TI사의 고속 DSP인 TMS320F2812 사용한다. 적용된 풍향 풍속 모듈을 통해 얻어진 데이터와 DSP 인터페이스 회로보드의 빠른 데이터 처리를 통해 저렴한 기상계측시스템을 구성 할 수 있었다.