• 제목/요약/키워드: mercury intrusion

검색결과 69건 처리시간 0.043초

A simplified directly determination of soil-water retention curve from pore size distribution

  • Niu, Geng;Shao, Longtan;Sun, De'an;Guo, Xiaoxia
    • Geomechanics and Engineering
    • /
    • 제20권5호
    • /
    • pp.411-420
    • /
    • 2020
  • Numbers fitting-curve equations have been proposed to predict soil-water retention curve (SWRC) whose parameters have no definitude physical meaning. And these methods with precondition of measuring SWRC data is time-consuming. A simplified directly method to estimate SWRC without parameters obtained by fitting-curve is proposed. Firstly, the total SWRC can be discretized into linear segments respectively. Every segment can be represented by linear formulation and every turning point can be determined by the pore-size distribution (PSD) of Mercury Intrusion Porosimetry (MIP) tests. The pore diameters governing the air-entry condition (AEC) and residual condition (RC) can be determined by the PSDs of MIP test. The PSD changes significantly during drying in SWR test, so the determination of AEC and RC should use the PSD under corresponding suction conditions. Every parameter in proposed equations can be determined directly by PSD without curve-fitting procedure and has definitude physical meaning. The proposed equations give a good estimation of both unimodal and bimodal SWRCs.

Resistance of Cementitious Binders to Chloride Induced Corrosion of Embedded Steel by Electrochemical and Microstructural Studies

  • Song, Ha-Won;Ann, Ki-Yong;Kim, Tae-Sang
    • Corrosion Science and Technology
    • /
    • 제8권2호
    • /
    • pp.74-80
    • /
    • 2009
  • The high alkaline property in the concrete pore solution protects the embedded steel in concrete from corrosion due to aggressive ions attack. However, a continuous supply of those ions, in particular, chlorides altogether with a pH fall in electrochemical reaction on the steel surface eventually depassivate the steel to corrode. To mitigate chloride-induced corrosion in concrete structures, finely grained mineral admixtures, for example, pulverized fuel ash (PFA), ground granulated blast furnace slag (GGBS) and silica fume (SF) have been often advised to replace ordinary Portland cement (OPC) partially as binder. A consistent assessment of those partial replacements has been rarely performed with respect to the resistance of each binder to corrosion, although the studies for each binder were extensively looked into in a way of measuring the corrosion rate, influence of microstructure or chemistry of chlorides ions with cement hydrations. The paper studies the behavior of steel corrosion, chloride transport, pore structure and buffering capacity of those cementitious binders. The corrosion rate of steel in mortars of OPC, 30% PFA, 60% GGBS and 10% SF respectively, with chloride in cast ranging from 0.0 to 3.0% by weight of binder was measured at 7, 28 and 150 days to determine the chloride threshold level and the rate of corrosion propagation, using the anodic polarization technique. Mercury intrusion porosimetry was also applied to cement pastes of each binder at 7 and 28 days to ensure the development of pore structure. Finally, the release rate of bound chlorides (i.e. buffering capacity) was measured at 150 days. The chloride threshold level was determined assuming that the corrosion rate is beyond 1-2 mA/$m^3$ at corrosion and the order of the level was OPC > 10% SF > 60% GGBS > 30% PFA. Mercury intrusion porosimetry showed that 10% SF paste produced the most dense pore structure, followed by 60% GGBS, 30% PFA and OPC pastes, respectively. It was found that OPC itself is beneficial in resisting to corrosion initiation, but use of pozzolanic materials as binders shows more resistance to chloride transport into concrete, thus delay the onset of corrosion.

$V_2O_5$를 도판트한 $TiO_2$의 미세구조와 감습에 미치는 알카리 옥사이드$ M_2O(M=Li,Na)$의 영향 (Effect of $Li_2O$ and $Na_2O$ addition on the microstructure and humidity sensitivity of $V_ 2O_5$-doped $TiO_2$)

  • 신용덕
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권6호
    • /
    • pp.605-615
    • /
    • 1996
  • In this paper, the effect of alkaline oxide addition such as Li$_{2}$O and Na$_{2}$O on the microstructure and humidity sensitivity of V$_{2}$O$_{5}$(2 mol%)-doped TiO$_{2}$(98 mol%) was investigated as a function of amount (0, 1, 2, 5, 10 mol%) of Li$_{2}$O and Na$_{2}$O additives. The pores in the alkaline free sample were distributed mostly in the range between 0.16 and 1.0.mu.m in diameter and its porosity was 23.29%. Li$_{2}$O caused grain overgrowth and reduced the porosity with a narrow distribution of the pore size, leading to poor humidity sensitivity. Na$_{2}$O helped to enlarge the distribution of the pore size through the formation of small soluble phases. The pore sizes of the sample containing Na$_{2}$O 2mol% were distributed mostly in the range between 1.0 and 2.5.mu.m in diameter and its porosity and intrusion volume of mercury were 31.13 % and 0.1155 mL/g respectively, which consequently improved the humidity sensing characteristics such as the sensitivity and temperature-stability. Especially, the addition of 2mol% of Na$_{2}$O improved the humidity-sensing characteristics such as sensitivity and linearity in the whole range between 30 and 90 %RH (Percentage Relative Humidity)y)

  • PDF

Optimal Use of MSWI Bottom Ash in Concrete

  • Zhang, Tao;Zhao, Zengzeng
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권2호
    • /
    • pp.173-182
    • /
    • 2014
  • An experimental investigation was carried out to evaluate the mechanical properties of concrete mixtures in which coarse aggregate was partially (30, 50 or 70 %) replaced with pre-washed municipal solid waste incineration (MSWI) bottom ash. Results indicated that bottom ash reduced the compressive strength, elastic modulus, and levels of heavy metals in leachate when used as a replacement for gravel, and that the maximum amount of MSWI bottom ash in concrete should not exceed 50 %. To analyze the effect mechanism of bottom ash in concrete, the degree of hydration and the following pozzolanic reaction characterized by the pozzolanic activity index, and the porosity distribution in cement mortar. The study indicates that improved properties of concrete are not solely later strength gain and reduced levels of heavy metals in leachate but also the progression of pozzolanic reactions, where a dense structure contains a higher proportion of fine pores that are related to durability.

고로슬래그미분말 혼합 콘크리트의 공극구조 및 염소이온 확산특성 (Characteristic of Pore Structure and Chloride ion Diffusion in Concrete Containing GGBF)

  • 문한영;김홍삼;최두선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.365-368
    • /
    • 2002
  • This paper considers transference number in calculating diffusion coefficient of chloride ions of concrete and mercury intrusion porosimetry to investigate the volume and distribution of pore size, respectively, analyzing and discussing the property of resistance to chloride ion of concrete with granulated blast furnace slag. The experimental results show that the diffusion coefficient of chloride ion decreases with the rise of quantity of granulated blast furnace slag and pore structure of concrete with granulated blast furnace slag is different from that of OPC concrete. And from the results of regression analysis, the result showed that the diffusion coefficient of chloride ions is affected by capillary pore above 50nm.

  • PDF

제지 슬러지 애쉬 고로슬래그 미분말로 혼합치환한 시멘트가 모르타르에 미치는 영향 (The Influences of Cement Mortar Replaced by Paper Sludge Ash and Blast Furnace Slag)

  • 소병현;이주나;박찬수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.3-9
    • /
    • 2002
  • Paper sludge ash was assured as material of a sort of pozzolan. For the reason of fluidity decrease caused by the strong absorption of paper stooge ash and the decrease of compressive strength in case of using over30% replacement by the weight of cement, paper sludge ash is not suitable for blending material. Therefore, it is necessary to find proper replacement ratios between paper sludge and blast furnace slag to insure compressive compensation and appropriate slump. Accordingly, as varied the blending ratios of paper sludge and blast furnace slag, testing mortar was made. This study was aimed to investigate the possibility of using blending replacement of paper sludge ash and blast furnace slag throughout compressive test, flow test, SEM(Scanning Eletron Microscope), MIP(Mercury Intrusion Porosity test), and TG-DTA(Thermal analysis).

  • PDF

포졸란 함유 콘크리트의 공극구조와 투과특성 (Pore Structure and Permeability of Concrete Containing Pozzolanic Materials)

  • 김재신;소형석;소승영;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.159-162
    • /
    • 1999
  • The paper presents results of an investigation on the permeability characteristics and pore structure of concrete containing different levels of fly ash, silica fume, or blast furnace slag. The total cementitious content was 351kg/㎥, and the water/cementitious materials ratio was 0.55. The porosity and pore structure of representative pastes of the matrix were measured using mercury intrusion porosimetry, and the permeability characteristics of concrete were also determined by water and oxygen permeability, chloride ion penetration. The results show that significant reduction in permeability of concrete containing pozzolanic materials due to formation of a discontinuous macro-pore system which inhibits flow. And, the permeability of concrete and pore structure(capillary porosity or total porosity) shows linear relationship.

  • PDF

실리카 흄을 혼입한 콘크리트의 투과특성에 관한 연구 (A Study on the Permeabilities of Concretes Containing Silica Fume)

  • 형원길;장효식;소형석;소승영;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.443-448
    • /
    • 1999
  • Tests have been carried out on four concrete containing different levels of silica fume to measure their permeability coefficient using water and oxygen, chloride ion. The total cementitious content was 351kg/㎥, and the water/cementitious materials ratio was 0.55. The results show that a dramatic reduction in permeability of concrete containing silica fume occurs due to formation of a discontinuous macro-pore system which inhibits flow. Porosity estimates from mercury-intrusion porosimetry are used to develop an explanations for the water and air permeability reduction. And, results of the rapid permeability test showed that the resistance of concrete to the penetration of chloride ions increases significantly as a contents of silica-fume is increased. The current intensity passing through the concrete containing silica fume is presented from 664C to 2166C.

  • PDF

Composite 라이닝 공법의 배수공 재료인 경량기포모르타르의 공극구조와 배수성능에 대한 고찰 (A Study on the Drain Performance & Pore Structure of Cellular Mortar which Drain Material of the Composite Lining Method)

  • 최희섭;마상준;이흥수;서신석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.425-426
    • /
    • 2009
  • 본 연구는 새로운 터널 공법인 Composite 라이닝 공법의 터널 배수재로 적용될 최적경량기포모르타르 배합을 선정하고자, 기포율 변화에 따른 경량기포모르타르의 공극구조를 분석하였다. 그 결과, 3.0MPa이상의 소요강도 확보와 더불어 투수성에 우수한 연속기포의 형성 및 분포가 가장 잘 이루어진 것으로 예상되는 FCR배합이 적합할 것으로 판단된다.

  • PDF

Oil Adsorption of Exfoliated Graphite Prepared by Direct Reaction between $SO_3$ Gas and Graphite

  • Lee, Beom-Jae;Kwon, Young-Bae
    • Carbon letters
    • /
    • 제2권1호
    • /
    • pp.55-60
    • /
    • 2001
  • Graphite intercalation compounds (GIC) were prepared by direct reaction of $SO_3$ gas with flake graphite. The intercalated $SO_3$ molecules were ejected by rapid heating to $950^{\circ}C$ under an oxidizing atmosphere for about 1 minute, resulting in surprisingly high expansion in the direction of c-axis. The characteristics of the micro-structure and pore size distribution were examined with a SEM and mercury intrusion porosimetry. The XRD analysis and spectroscopic analysis were used for the identification of the graphite and surface chemistry state. The pore size distribution of the exfoliated graphite (EG) was a range of $1{\sim}170{\mu}m$. The higher expanding temperature the higher expanded volume, so oil sorption capacities were 58.8 g of bunker-C oil and 34.7 g of diesel oil per 1 g of the the EG. The sorption equilibrium was achieved very rapidly within several minutes. As the treatment temperature increases, bulk density decreases.

  • PDF