Purpose: This study is to analyze the clinical and radiological results after arthroscopic reduction and internal fixation of intra-articular fractures of lateral tibial plateau. Materials and Methods: The subject of the study are the 13 cases of the patients visited orthopedics surgery during March year 2000 to August year 2004 because of intra-articular fractures of lateral tibial plateau and were treated with arthroscopic reduction and internal fixation. X-rays and CT or MRI were both carried out to identify the precise pattern of fracture and the degree of depression which showed out to be all type 2 by Schatzker fracture classification. And in 9 of the cases, autogenous and allogenous bone grafts were given as bone loss were severe. The average age was 48, age group between 31 and 66, and average follow up period of about 38 months ($13{\sim}65months$). Radiological ratings were given by comparing the X-rays of degree of joint congruency before and after the operation, functional ratings by analyzing IKDC score and Lysholm score. Combined injuries observed after arthroscopy were posterior cruciate ligament injury in 1 case, meniscus injury in 4 cases and medial collateral ligament in 2 cases. Results: During follow up, X-rays showed well-maintained reduction of articular surface in all cases and no complications such as joint depression, fracture reduction loss, angular deformity or malunion were found. Average Lysholm score at last follow up was 87 points ranging from 65 to 97, in 8 of the cases excellent, 3 good, 1 fair and 1 poor according to Lynsholm classification. Average IKDC score was 92 (from 82 to 99). Conclusion: Not only does arthroscopic reduction of lateral tibial plateau fracture bring exact reduction of articular surface, but also, is considered to be a good way of operation to diagnose and treat combined injuries of knee joint using arthroscopy.
Purpose: This article describes a double-bundle ACL reconstruction technique using a five-strand hamstring tendon autograft with conventional anteromedial bundle reconstruction and additional posterolateral bundle reconstruction. Operative technique: For the tibial tunnel, the conventional single tunnel technique is performed and for the femoral tunnel, the double tunnel technique is performed with the anteromedial and posterolateral bundle. After minimal notchplasty, the anteromedial femoral tunnel is prepared with leaving one milimeter of posterior femoral cortex within the over-the-top, which if positioned at the 11-o'clock orientation for the right knee or at the 1-o'clock position for the left knee. The posterolateral femoral tunnel that is located 5 to 7 mm superior to the inner margin of the lateral meniscus anterior horn at $90^{\circ}$ of flexion is prepared with tile outside-in technique using a 4.5 cannulated reamer. The graft material for the double bundle reconstruction is made of the conventional four-strand hamstring autograft in the anteromedial bundle and of a single-strand semitendinosus tendon in the posterolateral bundle. The anteromedial bundle is fixed with using a rigid fix system on the femoral side and the posterolateral bundle is fixed to tie with the miniplate from the outside femur. Then, with the knee in $10^{\circ}\;to\;20^{\circ}$ of flexion, a bioabsorbable screw is simultaneously applied to achieve tibial fixation with tensioning of both bundles. Conclusion: A double bundle reconstruction with five-strand hamstring autograft, which is designed with a favorable conventional anteromedial bundle and an additional posterolateral bundle to restore rotation stability, seems to be a very effective method for the treatment for ACL instabilities.
Seo, Jae-Seong;Min, Hak-Jin;Yoon, Ui-Seong;Kim, Hee-Seon;Kim, Yoon-Jong;Kim, Yoo-Mih
Journal of the Korean Arthroscopy Society
/
v.9
no.2
/
pp.174-179
/
2005
Purpose: To study the long-term outcome of arthroscopic meniscectomy with regard to clinical symptoms and radiographic signs of osteoarthritic change. Materials and Methods: The materials for the investigation consisted of 79 individuals among 144 patients who underwent knee arthroscopy due to an isolated meniscal tear from October 1990 to September 1992 in our hospital. Those 79 individuals were followed up for $10{\sim}15$ years after the knee arthroscopy and were took clinical examination through the review of knee radiographies obtained with weight bearing. 52 of the 79 patients were men, and the mean age of the total materials was 34.6 years old (in the range $17{\sim}48$). Results: At follow-up, radiographic changes including Fairbank changes and joint space narrowing were seen from 45 of the 79 patients (56.2%). In other calculation, radiographic changes were seen in 23 out of 54 patients (42.6%) who had a partial meniscectomy, but were presented in 22 out of 25 patients (88.0%) who had a total meniscectomy. As a result, more radiographic changes were seen after total meniscectomy (p=0.03). In clinical results, 39 out of 54 patients (72.2%) after partial meniscectomy were satisfactory, and 14 out of 25 patients (56.0%) after total meniscectomy were satisfactory, therefore, more percentage of patients were satisfactory in partial meniscectomy group than in total meniscectomy group, but the statistical differences were absent (p=0.24). Conclusion: The frequency of radiographic changes in $10{\sim}15$ years after meniscectomy was related to the quantity of the meniscus removed, but the differences of these changes were low and had little influence on activity and knee function.
Purpose: To evaluate the effects of total or subtotal meniscectomy on anterior cruciate ligament reconstruction. Materials and Methods: We reviewed the 455 cases of arthroscopic ACLR (anterior cruciate ligament reconstruction) from February, 2003 to February, 2007 and followed-up more than 1 year. The 93 cases were enrolled. The 45 cases who underwent only ACLR were included and the 48 cases who underwent ACLR with total or subtotal meniscectomy were included in this study except grade 3 or 4 chondral lesion, partial meniscetomy or meniscal repair. We divided the patient into 4 groups which were isolated ACLR group (group I, 45cases), ACLR with lateral meniscectomy group (group II, 10cases), ACLR with medial meniscectomy group (group III, 28cases) and ACLR with both medial and lateral meniscectomy group (group IV, 10cases). The clinical evaluation was done by range of motion (ROM), IKDC subjective score, Lysholm score, anterior drawer test, Lachman test, Pivot shift test and KT-1000 arthrometer. Results: At final follow up, group IV was inferior than group I in IKDC subjective score and Lysholm score, and inferior than group II in IKDC subjective score. In KT-1000 arhtometric test, group I had better results than group III and group IV. Also in anterior drawer test and Lachman test, group 1 had better result than group III and group IV. In pivot shift test, there was no significant difference among four groups. Conclusion: Medial or both medial and lateral meniscectomy had greater laxity in anterior drawer test, Lachman test and KT-1000 arthrometric test and both medial and lateral meniscectomy had a lower subjective score than both meniscus intact group.
The peroxo-polytungstic acid was formed by the direct reaction of tungsten powder with the hydrogen peroxide solution. Peroxo-polytungstic powder were prepared by rotary evaporator using the fabricated on to ITO coated glass as substrate by dip-coating method using $2g/10mL(W-IPA/H_2O)$ sol solution. A substrate was dipped into the sol solution and after a meniscus had settled, the substrate was withdrawn at a constant rate of the 3mm/sec. Thicker layer could be built up by repeated dipping/post-treatment 15 times cycles. The layers dried at the temperature of $65{\sim}70^{\circ}C$ during the withdrawn process, and then tungsten oxides thin film was formed by final heating treatment at the temperature of $230{\sim}240^{\circ}C$ for 30min. A linear rotation between the thickness of thin film and the number of dipping/post-treatment cycles for tungsten oxides thin films made by dip-coating was found. The thickness of thin film had $60{\AA}$ after one dipping. From the patterns of XRD, the structure of tungsten oxides thin film identified as amorphous one and from the photographs of SEM, the defects and the moderate cracks were observed on the tungsten oxides thin film, but the homogeneous surface of thin films were mostly appeared. The electrochemical characteristic of the $ITO/WO_3$ thin film electrode were confirmed by the cyclic voltammetry and the cathodic Tafel polaization method. The coloring bleaching processes were clearly repeated up to several hundreds cycles by multiple cyclic voltammetry, but the dissolved phenomenon of thin film revealed in $H_2SO_4$ solution was observed due to the decrease of the current densities. The diffusion coefficient was calculated from irreversible Randles-Sevick equation from the data obtained by the cyclic voltammetry with various scan rates.
Kim, Ki-Up;Gil, Hyo-Wook;Lee, Suk-Ho;Kim, Do-Jin;Na, Moon-Jun;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik
Tuberculosis and Respiratory Diseases
/
v.52
no.1
/
pp.46-53
/
2002
Background: Pulmonary aspergilloma is relatively common in korea. It arises from the colonization and proliferation of Aspergillus in preexisting lung parenchymal cavities, in particular tuberculosis. The most common symptom in this disorder is hemoptysis, which mayor may not be massive and life threatening. A routine chest radiography and computed tomography (CT) are the most important diagnostic procedures. A surgical resection of the aspergilloma has recently been recommended, because of the relatively low incidence of postoperative complications than in the past. A more concentrated sample of patients with aspergilloma, who either underwent a thoracotomy or tested positive for aspergillus antibodies, were reviewed. Method : The medical records of twenty-two patients with aspergilloma, who had a proven thoracotomy (9 cases), or who tested positive for the diagnostic procedure and/or aspergillus antibodies (13 cases) from January 1995 to December 2000, were reviewed retrospectively. Results : The most common underlying lung disease was a current or old healed tuberculosis, and 3 patients had cultures of mycobacterium other than tuberculosis (MOTT). The mean time until the aspergilloma was detected 5.91 years in the healed tuberculosis cases. The others cases involved a lung abscess, bronchiectasis and without lung disease. The extrapulmonary disease was alcoholism and diabetes. Hemoptysis was most common in 72.7%. A computed tomography (CT) is useful for diagnosis. The right upper lobe, especially the posterior segment, is the most common location. Bronchial artery embolization is ineffective for a long term follow-up. A lobectomy is most common in a thoracotomy, and intra-operative and post-operative complications are rare. During follow-up, the mortality rate, not from the aspergilloma but from respiratory failure, was 13.6%. Conclusion : Aspergilloma is a common cavitary lung disease, It mainly arises from tuberculosis, either current or healed, but extra-pulmonary disease including alcoholism or diabetes are other possible risk factors. Their most common problem in aspergilloma is hemoptysis. Surgery has a low risk of post-operative complications and is recommended in relatively preserved lung function or healthy patients. Medical maneuvers including embolization, and the local insertion of certain materials needs to be studied more closely.
Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
Journal of the Korean Arthroscopy Society
/
v.12
no.3
/
pp.191-197
/
2008
Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.