• Title/Summary/Keyword: meniscus

Search Result 327, Processing Time 0.019 seconds

DIAGNOSTIC RELIABILITY OF THE DYNAMIC MRI FOR THE INTERNAL DERANGEMENT OF TEMPORO-MANDIBULAR JOINTS (악관절내장증의 진단에 있어 Dynamic MRI의 효용)

  • Park, Chang-Hwan;Kim, Myung-Rae;Kim, Sun-Jong;Cheong, Eun-Chul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.3
    • /
    • pp.273-280
    • /
    • 1994
  • The Magnetic Resonance Imaging has been used widely to evaluate the disk position without any interruption of the TMJ structures, and the Dynamic MRI presenting computed serial imaging or the video-recorded simulation images is thought to be very effective to evaluate the disk position under function. This is to study the correlation between the clinical diagnosis and the findings of Dynamic MRI for the diagnosis of internal derangement of the temporomandibular joints. 30 joints(15 patients) were examined clinically, and the movement of TMJ meniscus was reviewed in the dynamic MRI. The comparative results are as follows : 1. All internal derangements of TMJ disk displacement without reduction were consistent with MRI findings. 2. 5 joints (50%) of disk displacements with reduction could not be confirmed by MRI findings. 3. The disk displacements in MRI were found in 55% of painful joints, 50% of clicking joints, and 70% of the joints with restricted movement. 4. The reliability of MRI for the diagnosis of TMD was evaluated as 77% ; 24 of 30 joints who presented with clinical diagnosis of TMD. 5. MRI is very reliable to diagnose the disk displacement without reduction, but it is rather not so effective to diagnose the early derangement or muscle disorders.

  • PDF

The synovial chondromatosis of the temporomandibular joints: review of the 4 cases (측두하악관절의 활액성 연골종증 4예)

  • Lee, Dong-Hyun;Shin, Jung-Sub;Kwak, Ju-Hee;Kim, Jin-Woo;Kim, Sun-Jong;Kim, Myung-Rae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.134-140
    • /
    • 2010
  • Synovial condromatosis of the temporomandibular joint (TMJ) is characterized by the presence of loose bodies (joint mices). It can be confused with temporomandibular disorder clinically, and be with chondrosarcoma histologically. The purpose of this clinical report was to review the clinical, radiological, arthroscopic findings, histological feature and the results of surgical treatment of TMJ synovial chondromatosis. Four patients presented with pain of TMJ and limited mouth opening. The dynamic magnetic resonance imaging (MRI) disclosed a characteristic morphologic changes and displacement of the meniscus with limited translation of the condyle head. Bone scans showed progressive resorptive changes with hot-uptake of the radioisotope. The synovial loose bodies in the joint spaces were removed and sent to pathology for diagnosis as the synovial chondromatosis. The follow-up examination with computed tomography (CT) and MRI revealed no evidence of recurrence and good in function until postoperative 18 months. Diagnostically, the distension of the lateral capsule and fluid findings in the joint on the MRI are very suggestive tool for this synovial chondromatosis, but they are not always detected on the preoperative MRI. Arthroscopic approaches are very useful to inspect the joint spaces and to remove the loose bodies without interruption of the whole synovial membranes.

Experimental and Numerical Study on the Capillary Performance of Non-Homogeneous Micro-Post Arrays (비 균일적 마이크로 원기둥 배열을 이용한 고성능 냉각 표면)

  • Byon, Chan;Kim, Sung Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1091-1097
    • /
    • 2013
  • In this article, an advanced cooling surface based on micro-post arrays with non-homogeneous configurations is investigated and compared with conventional micro-post arrays with homogeneous configuration. The capillary performance of micro-post arrays are characterized using the capillary rate of rise experiments and numerical simulations which take into account the meniscus curvature. The experimental and numerical results show that that the capillary performance of the micro-post wick can be significantly enhanced, compared with the homogeneous type wick, by employing non-homogeneous configurations. The capillary performance is shown to be primarily a function of the solid fraction and increases linearly with decreasing solid fraction, regardless of the wick configuration, when the solid fraction is larger than 0.25. However, the capillary performance is found to be significantly reduced when the solid fraction falls below approximately 0.25.

Electro-spray Micro-Thruster Using Nozzle with Pole-Type Electrode (기둥 구조 전극을 내재하는 노즐을 이용한 정전 분무 마이크로 추진기관)

  • Lee, Young-Jong;Yang, Ji-Hye;Lee, Suk-Han;Kim, Yong-Jae;Koh, Han-Seo;Byun, Do-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.12
    • /
    • pp.1115-1120
    • /
    • 2007
  • This paper presents a novel mechanism of electro-spray micro-thruster featured by a nozzle with a conductive pole inside, referred to here as a pole type nozzle. And the effects of the pole type nozzle on the efficiency of the jetting are numerically and experimentally investigated. The electric voltage signal applied to the upper electrode plate, against the pole as the ground, allows a ejection of spray to take place. It is verified experimentally that the use of the pole type nozzle allows a stable and sustainable jetting mode of ejection for a wider range of applied voltages because it can concentrate the electric field more on the centre of the meniscus. According to results about size effect, experiments indicates that the proposed mechanism allows that operation of micro thruster at less than 500 volts through nanoscale nozzle.

Numerical Simulation of Inkjet Drop Formation in Piezo Inkjet Head (피에조 잉크젯 헤드의 액적 토출 형상 전산해석)

  • Joo, Youngcheol;Park, Sangkug;Kwon, Key-Si
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.641-647
    • /
    • 2016
  • A drop-on-demand inkjet is used widely for various applications. Therefore, it is important to understand the jetting behavior of the drop from the piezo inkjet. In this study, to predict the jetting behavior, VOF (Volume-of-Fluid) simulation techniques were used and compared with the experimental results. The experimentally measured meniscus movement was used as the input data for the simulation. To verify the simulation, the measured jetting behavior of the mixture fluids of ethylene glycol and IPA (isopropyl alcohol), which has a mixing ratio of 50:50, was used. The numerical simulation of the drop formation using various mixture ratios and its comparison with the measured drop formation confirmed that the proposed method can predict the actual jetting. On the other hand, the satellite drop behavior showed slight differences because the small sized droplet is subject to a more aerodynamic effect during flight because the kinetic energy of the satellite droplet is far smaller than that of the main droplet.

Optical properties of $YVO_{4}$ and Nd:$YVO_{4}$ single crystals grown by developed EFG method (Developed EFG법으로 성장시킨 $YVO_{4}$ 및 Nd:$YVO_{4}$ 단결정의 광학적 특성)

  • ;;M.A. Ivanov;V.V. Kochurikhin
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.4
    • /
    • pp.180-183
    • /
    • 2001
  • $YVO_{4}$ and Nd:$YVO_{4}$ single crystals have been grown developed Edge-defined film-fed growth (EFG) method and the crystals were measured on optical properties. $YVO_{4}$ and Nd:$YVO_{4}$ single crystal were transparent, high quality due to homogeneity of surface temperature of the melt and stability of meniscus during crystal growth. In transmittance and absorption spectra, Nd:$YVO_{4}$ single crystals had absorption peaks at wavelengths of 532, 593, 753, 808, 888 though $YVO_{4}$ single crystal had a broad transmittance at wavelength ranging from 340 to 1000nm. Also, Nd:$YVO_{4}$ single crystals had emissions of energy at range of 800~900 nm in photoluminescence (PL) spectrum.

  • PDF

Testing of a Convex Aspheric Secondary Mirror for the Cassegrain Telescope (카세그레인 망원경의 볼록비구면 반사경 파면오차 측정)

  • Kim, Goeun;Rhee, Hyug-Gyo;Yang, Ho-Soon
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.290-294
    • /
    • 2017
  • The Cassegrain telescope consists of a primary concave mirror and a secondary convex mirror. In the case of a secondary mirror, it is more difficult to test wavefront error than for a primary mirror, because it reflects the entire testing beam, as it is convex in shape. In this paper we tested the wavefront error of a complex aspheric convex secondary mirror by using the Simpson-Oland-Meckel Hindle test. To separate the systematic errors, such as fabrication error and alignment error of a meniscus lens, we adopted the QN absolute test (pixel-based absolute test using the quasi-Newton method) as well. Finally, we compared the measured result with that of an ASI (Aspheric Stitching Interferometer) made by the QED company, which resulted in an rms difference of only 2.5 nm, showing a similar shape of astigmatism aberration.

MRI Diagnosis of the Tear Pattern of Menisci (반월상 연골판 파열 양상의 자기공명영상 진단)

  • Ahn, Jin Hwan;Ha, Chul Won;Ahn, Joong Mo;Kim, Sang Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.151-154
    • /
    • 1998
  • In the diagnosis of the meniscal tear of the knee, the high accuracy of the MRI diagnosis is well-known, but the accuracy of the MRI in the diagnosis of the very pattern of the tear of menisci is not well-established. The purpose of this study is to give some informations to consider in the diagnosis and therapeutic planning of torn menisci. The authors performed a retrospective study comparing the MRI and arthroscopic findings of 141 knees which had undergone arthroscopic surgery from Mar. 1997 to Mar. 1998. The results are as follows. In the diagnosis of tear of the menisci, MRI had sensitivity of 91%, specificity of 96%, accuracy of 95%. The mismatch of the tear patterns of the menisci between MRI and arthroscopic findings was identified in 59%, especially high in flap tear(100%), complex tear(84%), peripheral tear(55%). In conclusion, MRI is very accurate in the diagnosis of the tear of menisci, but the tear patterns of the menisci cannot be accurately determined by MRI. In the cases of flap tears, complex tears and peripheral tears, it is more difficult to determine the tear patterns of the menisci by MRI. False-negative rate of MRI was especially high(44%) in the peripheral tear type. So, other clinical correlations should be made in determination of the presence of the tear in the diagnosis of peripheral tear of the menisci.

  • PDF

Treatment of Osteochondroma of the Mandibular Condyle with Inferior Adhesion of Meniscus: A Case Report (관절원판의 유착을 동반한 하악과두의 골연골종의 치료: 증례보고)

  • Seol, Dong-Ju;Choi, Byung-Joon;Kim, Yeo-Gab;Lee, Baek-Soo;Ohe, Joo-Young;Lim, Ji-Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.3
    • /
    • pp.189-194
    • /
    • 2013
  • Osteochondroma is a benign neoplasm, osseous projection surrounded with cartilage, 35.8% of benign osseous tumor, 8.5% of whole osseous tumor and usually arises from the skeletal bone. Osteochondroma is a cartilaginous derivation and relatively uncommon in the craniofacial bone. Osteochondroma of the mandible has slow growth rates which mainly affect women around forty years of age and it can appear through the coronoid process and mandibular condyle, especially in the medial half. Clinical finding associated with osteochondroma of condyle are primarily a palpable, painless temporomandibular area mass with facial asymmetry, malocclusion and midline deviations. Sometimes pain and dysfunction like trismus often accompany the anatomic derangement. Other features include malocclusion with open-bite on the affected side and cross-bite on the contralateral side. In this study, a 45-years old female patient exhibits pain on the left temporo-mandibular joint area and malocclusion due to loss of the molar region with osteochondroma on the top left of her mandibular condyle head. The patient is able to recover gradually from the symptom through treatments on manipulation, stabilization splint, arthroscopic lavage and surgical excision, thus, this is reported as a clinical case.

Effect of Processing Parameters on the Formation of Large Area Self-Assembled Monolayer of Polystyrene Beads by a Convective Self-Assembly Method (대류성 자기조립법을 통한 폴리스티렌 비드 대면적 단일층 형성에 미치는 공정 변수 효과)

  • Seo, Ahn-na;Choi, Ji-Hwan;Pyun, Jae-chul;Kim, Won Mok;Kim, Inho;Lee, Kyeong-Seok
    • Korean Journal of Materials Research
    • /
    • v.25 no.12
    • /
    • pp.647-654
    • /
    • 2015
  • Self-assembled monolayers(SAM) of microspheres such as silica and polystyrene(PS) beads have found widespread application in photonic crystals, sensors, and lithographic masks or templates. From a practical viewpoint, setting up a high-throughput process to form a SAM over large areas in a controllable manner is a key challenging issue. Various methods have been suggested including drop casting, spin coating, Langmuir Blodgett, and convective self-assembly(CSA) techniques. Among these, the CSA method has recently attracted attention due to its potential scalability to an automated high-throughput process. By controlling various parameters, this process can be precisely tuned to achieve well-ordered arrays of microspheres. In this study, using a restricted meniscus CSA method, we systematically investigate the effect of the processing parameters on the formation of large area self-assembled monolayers of PS beads. A way to provide hydrophilicity, a prerequisite for a CSA, to the surface of a hydrophobic photoresist layer, is presented in order to apply the SAM of the PS beads as a mask for photonic nanojet lithography.