• 제목/요약/키워드: membrane resistance

검색결과 859건 처리시간 0.025초

MBR 공정에서 수온에 따른 막오염 및 CEB 세정효율 특성 (Characterization of membrane fouling and CEB (Chemical enhanced backwashing) efficiency with temperature in SMBR Process)

  • 박기태;박정훈;최은혜;김형수;김지훈
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.389-395
    • /
    • 2017
  • In this paper, we investigate the characteristics of membrane fouling caused by water temperature in the Membrane bioreactor(MBR) process and try to derive the membrane fouling control by chemical enhanced backwashing(CEB). The extracellular polymeric substances(EPS) concentration was analyzed according to the water temperature in the MBR, and the membrane fouling characteristics were investigated according to the conditions, with sludge & without sludge, through a lab-scale reactor. As shown in the existing literature the fouling resistance rate was increased within sludge with the water temperature was lowered. However, in the lab-scale test using the synthetic wastewater, the fouling resistance increased with the water temperature. This is because that the protein of the EPS was more easily adsorbed on the membrane surface due to the increase of entropy due to the structural rearrangement of the protein inside the protein as the water temperature increases. In order to control membrane fouling, we tried to derive the cleaning characteristics of CEB by using sodium hypochlorite(NaOCl). We selected the condition with the chemicals and the retention time, and the higher the water temperature and the chemical concentration are the higher the efficiencies. It is considered that the increasing temperature accelerated the chemical reaction such as protein peptide binding and hydrolysis, so that the attached proteinaceous structure was dissolved and the frequency of the reaction collision with the protein with the chemical agent becomes higher. These results suggest that the MBRs operation focus on the fouling control of cake layer on membrane surface in low temperatures. On the other hand, the higher the water temperature is the more the operation strategies of fouling control by soluble EPS adsorption are needed.

실란 표면 개질된 나노복합막의 염료 분리 특성 (Surface Modification of Nanofiltration Membrane with Silane Coupling Agents for Separation of Dye)

  • 박희민;임지은;김성애;이용택
    • 멤브레인
    • /
    • 제28권6호
    • /
    • pp.414-423
    • /
    • 2018
  • 본 연구에서는 염색 염료 산업의 폐수 처리 및 재활용 공정에 분리막을 적용하고자 실란 커플링제를 이용하여 상용화된 나노복합막을 표면 개질하였다. 실란 커플링제는 말단 관능기가 다른 octyltrimethoxysilane (OcTMS)와 (3-aminopropyl) trimethoxysilane (APTMS)을 사용하였으며, 표면 개질을 통해 염료 분리 및 내오염성을 향상시키고자 하였다. XPS, FE-SEM, EDX 분석을 통하여 막 표면의 화학 구조 변화 및 실란 적층을 확인하였고, AFM 분석을 통해 개질막의 표면 모폴로지를 확인하였다. Zeta potential을 통해 실란 개질 막이 상용막 대비 표면 전하가 중성으로 변하는 것을 확인하였다. 그 결과, OcTMS와 APTMS로 개질한 막의 내오염성은 NE70에 비해 약 2배 이상 향상되었다. 또한, 실란으로 표면 개질한 나노복합막은 음이온 염료(Orange II) 용액에서 약 90% 이상, 양이온 염료(Safranin-O) 용액에서 약 98% 이상의 염료 제거율을 나타내어 양이온 염료 용액 처리에 적합한 것을 확인하였다.

고성능 역전기투석을 위한 세공충진 음이온교환막의 개발 (Development of Pore-Filled Anion-Exchange Membranes for High Performance Reverse Electrodialysis)

  • 김도형;송현비;윤경석;강문성
    • 멤브레인
    • /
    • 제32권5호
    • /
    • pp.336-347
    • /
    • 2022
  • 역전기투석(reverse electrodialysis, RED)은 이온교환막을 격막으로 이용하여 해수와 담수의 농도차로부터 발전하는 유망한 친환경 재생에너지 기술 중 하나이다. 이온교환막은 RED의 성능을 좌우하는 핵심 구성요소로 낮은 전기적 저항, 높은 이온선택투과도, 우수한 내구성 및 저렴한 제조 비용 등의 요구조건을 만족시켜야 한다. 본 연구에서는 다양한 두께 및 기공율을 갖는 다공성 고분자 지지체를 이용하여 세공충진 음이온교환막을 제조하고 이온교환 고분자의 조성과 막 두께가 RED의 발전 성능에 미치는 영향을 조사하였다. 이온교환막의 전기적 저항이 충분히 낮은 경우 RED 발전 성능은 주로 막의 apparent permselectivity에 의해 좌우됨을 확인할 수 있었다. 또한 막의 apparent permselectivity는 IEC, 가교도, 막 두께, 표면 개질 등을 통해 향상시킬 수 있으며 전기적 저항과의 trade off 관계를 고려하여 최적 조건을 찾아야 함을 확인하였다.

콘칼로리미터를 이용한 건축용 막재의 내화 특성 연구 (A Fire Resistance Property Study of Architectural Fabric using Cone Calorimeter)

  • 김지현;신현욱;송훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.158-159
    • /
    • 2015
  • Architectural fabrics are now used in membrane structure with the merits of free shape, lightness and opened up new possibility for the design of new building structures. Recently PVC, PVF, PVDF, PTFE coated fabric for using the membrane structures. However, clear standards for the design and construction is not exist because of the lack of Architectural fabric research. In this paper, Flammable properties of PVDF, PTFE coated fabrics are obtained through the Flammability test using the Cone Calorimeter. Based on these results, identify the fire resistance property of the Architectural fabric.

  • PDF

생물학적 막분리 공정에서 수동흡착 상태에서의 유기물 유입 부하에 따른 소수성 막의 오염도 분석 (Analysis of Hydrophobic Membrane Fouling on the COD Loading Rates at the State of Passive Adsorption in Membrane Bioreactor)

  • 박태영;최창규
    • 대한환경공학회지
    • /
    • 제37권3호
    • /
    • pp.152-158
    • /
    • 2015
  • 본 연구는 소수성 막 재질에 대한 막오염도를 평가하고자 수동흡착의 개념을 도입하여 정상운전을 위한 막 모듈 이외에 수동흡착 시험용 막 모듈을 설치하여 유출을 시키지 않은 상태에서 막 표면에 부착되는 미생물에 의한 막오염 정도를 분석함으로써 소수성 막오염 잠재성을 평가하고자 하였으며, 이때 운전조건으로 유기물 유입부하를 변화시켜 평가하였다. 이와 더불어 오염된 멤브레인을 세 가지 세정방법(두가지 물리적 세정과 화학적 세정)을 통해 막 세정 전후의 막오염 회복률을 평가하였다. 막오염 평가인자로는 반응조 내 MLSS 농도와 EPS 농도를 조사하였으며, 여과저항 값을 산정하여 막오염 전과 후, 세정 3단계 전과 후를 비교 평가하였다. 실험 결과로서, COD 농도가 750 mg/L인 가장 높은 부하량 조건에서 반응조 내 EPS 농도와 수동흡착 시험용 멤브레인의 여과저항 값이 가장 높게 나타났다. 또한 여과저항 값이 초기 운전 시작 후 차이를 보였지만 60일 이후의 최종 여과저항은 거의 일정하게 나타났는데, 이는 막 표면에 부착된 미생물량이 임계점에 이르러 수동흡착만으로는 더 이상의 막오염은 진행되지 않은 것으로 판단된다. PAds 상태에서 유기물 유입부하에 따른 오염된 막의 세정 전후의 여과저항 측정 결과에서는 3단계 세정 후 평균 회복률이 각각 Run 1이 78%, Run 2가 72%, Run 2가 69%로 유기물 부하가 높을수록 회복률이 떨어지는 것으로 나타났으며, 반면에 물리적 세정에 의한 복원률이 40일 경부터 Run 2와 Run 3의 물리적 세정에 의한 회복률이 낮아지는 것으로 보아 높은 유기물 부하로 인한 막표면의 케이크 형성으로 막오염이 심화된 것으로 판단된다.

Transport Properties of Crosslinked Poly Vinyl Alcohol Membrane in Pervaporation

  • Lee, Chul-Haeng;Hong, Won-Hi
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 추계 총회 및 학술발표회
    • /
    • pp.92-93
    • /
    • 1996
  • PVA membrane was widely used in the dehydration pervaporation process. PVA membrane showed remakable selectivity towed water and an excellent film-forming polymer, with a good resistance to orgamic solvents but it has poor stability in aqueous mixtures. Generally the PVA is manufactured by the hydrolysis reaction from poly vinyl acetate(PVAc) and so the degree of PVA hydrolysis is a major parameter for properties of PVA membrane such as the crystallinity and polarity.

  • PDF

산성용액 노출 시 폴리아마이드 분리막의 표면성질 및 투과성능 변화에 관한 총설 (Review on Changes in Surface Properties and Performance of Polyamide Membranes when Exposed to Acidic Solutions)

  • 이형개;후엔티탄다오;강우석;권영남
    • 멤브레인
    • /
    • 제30권5호
    • /
    • pp.283-292
    • /
    • 2020
  • 산업분야에서는 다양한 용액을 대상으로 분리, 정제, 농축 등의 공정이 필요하며, 분리막이 그 역할을 잘 수행해 오고 있다. 반면, 처리 대상 용액이 강산을 함유하고 있는 경우, 대부분의 분리막은 산에 취약하기 때문에 사용이 제한적일 수밖에 없다. 현재 내산성 분리막으로 상용화 되고 있는 분리막은 투과속도가 낮은 문제점을 갖고 있다. 이에, 투과속도가 높은 폴리아마이드 분리막에 내산성을 부여하기 위한 접근 방법을 모색하기 위한 기초 자료로 본 총설에서는 폴리아마이드 분리막이 산성 용액 노출 시 표면성질 및 투과특성이 변화하는 원인과 기작에 대해 살펴보고자 한다.

우레탄 도막방수재의 시공조건에 따른 물성변화 (A Study on the Physical Property by Construction Condition of Urethane Waterproofing Membrane)

  • 김영삼;한천구
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권6호
    • /
    • pp.138-144
    • /
    • 2013
  • 비노출형 도막방수재 도포 후 누름콘크리트 타설 시기에 따른 도막방수재의 물리적 특성과 바탕면 조건, 도막두께 및 보강포 사용유무에 따른 내피로성을 검토하였는데, 누름콘크리트 타설 시기가 짧을수록 변색이 심하였고, 도막두께가 두꺼운 반면 인장성능이 낮았다. 내피로 성능은 3 mm의 도막두께에서는 파단되지 않았으나 1, 2 mm는 모두 파단 되었고 부직포로 보강한 경우의 내피로성능이 상대적으로 우수한 것으로 나타났다.

Silicone Rubber Membrane의 제조 및 기공특성 (Preparation of Silicone Rubber Membrane and its Porosity)

  • 이승범;김형진;홍인권
    • Elastomers and Composites
    • /
    • 제30권3호
    • /
    • pp.185-194
    • /
    • 1995
  • Membrane process has been employed to separate a specific substance from gas or liquid mixture, and treat wastewater. This is due to the fact that the substance of mixture can be permeated and separated selectively by membrane. Since Initial equipment and operation costs are not expensive, membrane process has been adopted in various fields such as petroleum Industry, chemistry, polymer, electronics, foods, biochemical industry and wastewater treatment. In this study, $CaCO_3$ particles impregnated in silicone rubber network were extracted by using supercritical carbon dioxide and pore distribution of silicone $rubber-CaCO_3$ was investigated with varying amount of extract. Silicone rubber has excellent mechanical properties such as heat-resistance, cold-resistance etc. and $CaCO_3$ has microporous structure. It is possible to make silicone $rubber-CaCO_3$ composite sheets via work-intensive kneading processes. In so doing $CaCO_3$ particles become distributed and impregnated in silicone rubber network. Supercritical carbon dioxide diffuse through composite sample, then sample is swollen. $CaCO_3$ in silicone rubber network Is dissolved in supercritical carbon dioxide, and its sites become pores. Pore distribution, pore shape and surface area are observed by SEM(scanning electron microscope) micrograph and BET surface area analyzer examination respectively. Pore characteristics of membrane suggest the possibilities that the membrane can be used for process of mixture separation and wastewater treatment.

  • PDF

Generalized load cycles for dynamic wind uplift evaluation of rigid membrane roofing systems

  • Baskaran, A.;Murty, B.;Tanaka, H.
    • Wind and Structures
    • /
    • 제14권5호
    • /
    • pp.383-411
    • /
    • 2011
  • Roof is an integral part of building envelope. It protects occupants from environmental forces such as wind, rain, snow and others. Among those environmental forces, wind is a major factor that can cause structural roof damages. Roof due to wind actions can exhibit either flexible or rigid system responses. At present, a dynamic test procedure available is CSA A123.21-04 for the wind uplift resistance evaluation of flexible membrane-roofing systems and there is no dynamic test procedure available in North America for wind uplift resistance evaluation of rigid membrane-roofing system. In order to incorporate rigid membrane-roofing systems into the CSA A123.21-04 testing procedure, this paper presents the development of a load cycle. For this process, the present study compared the wind performance of rigid systems with the flexible systems. Analysis of the pressure time histories data using probability distribution function and power spectral density verified that these two roofs types exhibit different system responses under wind forces. Rain flow counting method was applied on the wind tunnel time histories data. Calculated wind load cycles were compared with the existing load cycle of CSA A123.21-04. With the input from the roof manufacturers and roofing associations, the developed load cycles had been generalized and extended to evaluate the ultimate wind uplift resistance capacity of rigid roofs. This new knowledge is integrated into the new edition of CSA A123.21-10 so that the standard can be used to evaluate wind uplift resistance capacity of membrane roofing systems.