• 제목/요약/키워드: medium-resolution

검색결과 307건 처리시간 0.029초

Time Reversal Beam Focusing of Ultrasonic Array Transducer on a Defect in a Two Layer Medium

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Bae, Sung-Min
    • 비파괴검사학회지
    • /
    • 제29권3호
    • /
    • pp.242-247
    • /
    • 2009
  • The ability of time reversal techniques to focus ultrasonic beams on the source location is important in many aspects of ultrasonic nondestructive evaluation. In this paper, we investigate the time reversal beam focusing of ultrasonic array sensors on a defect in layered media. Numerical modeling is performed using the commercially available software which employs a time domain finite difference method. Two different time reversal approaches are considered - the through transmission and the pulse-echo. Linear array sensors composed of N elements of line sources are used for signal reception/excitation, time reversal, and reemission in time reversal processes associated with the scattering source of a side-drilled hole located in the second layer of two layer structure. The simulation results demonstrate the time reversal focusing even with multiple reflections from the interface of layered structure. We examine the focusing resolution that is related to the propagation distance, the size of array sensor and the wavelength.

THE ENVIRONMENT OF TYCHO: POSSIBLE INTERACTION WITH A MOLECULAR CLOUD

  • LEE J.-J.;KOO B.-C.;TATEMATSU K.
    • 천문학회지
    • /
    • 제37권4호
    • /
    • pp.223-224
    • /
    • 2004
  • The Tycho supernova remnant (SNR), as one of the few historical SNRs, has been widely studied in various wavebands and previous observations have shown evidence that Tycho is interacting with a dense ambient medium toward the northeast direction, In this paper, we report our high-resolution (16') $^{12}CO$ observation of the remnant using the Nobeyama 45m radio telescope. The Nobeyama data shows that a large molecular cloud surrounds the SNR along the northeastern boundary. We suggest that the Tycho SNR and the molecular cloud are both located in the Perseus arm and that the dense medium interacting with the SNR is possibly the molecular cloud. We also discuss the possible connection between the molecular cloud and the Balmer-dominated optical filaments, and suggest that the preshock gas may be accelerated within the cosmic ray and/or fast neutral precursor.

MOLECULAR GAS PROPERTIES UNDER ICM PRESSURE IN THE CLUSTER ENVIRONMENT

  • LEE, BUMHYUN;CHUNG, AEREE
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.491-494
    • /
    • 2015
  • We present 12CO (2-1) data for four spiral galaxies (NGC 4330, NGC 4402, NGC 4522, NGC 4569) in the Virgo cluster that are undergoing different ram pressure stages. The goal is to probe the detailed molecular gas properties under strong intra-cluster medium (ICM) pressure using high-resolution millimeter data taken with the Submillimeter Array (SMA). Combining this with Institut de RadioAstronomie $Millim{\acute{e}}trique$ (IRAM) data, we also study spatially resolved temperature and density distributions of the molecular gas. Comparing with multi-wavelength data (optical, $H\small{I}$, UV, $H{\alpha}$), we discuss how molecular gas properties and star formation activity change when a galaxy experiences $H\small{I}$ stripping. This study suggests that ICM pressure can modify the physical and chemical properties of the molecular gas significantly even if stripping does not take place. We discuss how this affects the star formation rate and galaxy evolution in the cluster environment.

Metallicity Distribution of the Galactic Halo from SDSS Photometry

  • 안덕근
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.144.1-144.1
    • /
    • 2011
  • We explore the metallicity distribution of the Galactic halo based on the SDSS ugriz photometry. We use empirically calibrated sets of stellar isochrones to determine distances and metallicities of individual main-sequence stars in the halo. At heliocentric distances greater than 5 kpc, we find that the in situ photometric metallicity distribution reveals chemically divided dual halo components, which supports arguments from earlier studies based on the medium resolution spectroscopy. Our finding provides an unbiased estimate of relative fractions of each of these stellar components in the Galactic halo.

  • PDF

조영제 혈관외유출 현상의 3D MDCT 재구성 영상 (3D MDCT Reformation Findings of the Radiographic Contrast Medium Extravasation)

  • 권대철;김정구
    • 한국콘텐츠학회논문지
    • /
    • 제6권5호
    • /
    • pp.145-152
    • /
    • 2006
  • 전산화단층촬영에서 자동주입기에 의한 방사선 조영제의 혈관외유출(140mL)이 우측 손등의 IV 카테터 부위에서 발생하였다. 혈관외유출은 부종 및 괴사를 동반하였고, 구획증후군으로 발전하였다. 혈관외유출 부위를 MDCT로 스캔하여, 3D 재구성 영상인 MPR, MIP, volume rendering으로 재구성하였다. 이러한 3D 재구성 영상은 조영제의 혈관외유출 부위를 침범 정도를 정확하게 확인하여 환자 예방의 필요성 및 사후 조치에 적절한 치료 및 수술 계획에 유용하게 이용될 수 있다.

  • PDF

중형카메라의 항공삼각측량 정확도 분석 (Accuracy Analysis of Aerial Triangulation Using Medium Format CCD Camera RCD105)

  • 강준묵;원재호;소재경
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.251-252
    • /
    • 2010
  • 최근 항공측량분야에서 항공디지털카메라 및 항공레이저측량시스템은 DEM제작 및 지형분석 등의 지리정보 구축에 활용되고 있다. 본 연구에서는 ALS50II에 포함된 중형CCD카메라인 RCD105에 대한 3차원 위치정확도를 고해상도 항공디지털카메라인 DMC와 비교하였다. 이를 위해 촬영지역을 선정 및 항공사진촬영을 실시하였으며 1/1,000 수치지형도에서 지상기준점을 선점하였다. RCD105와 DMC에 대해 항공삼각측량 후 최소제곱오차(RMSE)를 비교하였다.

  • PDF

Research on the relationship between the thermal characteristics and the type of land cover in Beijing urban area by ASTER data

  • Zhu, QiJiang;Zhang, Xin;Bai, Xianghua
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.277-279
    • /
    • 2003
  • The study utilizes remote sensing as the main monitoring means. With different spatial high-resolution, multichannel ASTER remote sensing image as the main information in Beijing city zone; with regional border and statistical data as auxiliary factor a study between the thermal space distribution character and the underground medium is analyzed based on the GIS logical algorithm and synthetic analysis technology. Results show thermal forming mechanism and the rule of distribution is mainly related to the underground medium and the change of the city distribution. Different underground medium has different degree and intensity influence on the thermal space distribution. Furthermore, urban greenbelt and water areas can reduce the thermal effect and large-scale greenbelt creates green island effect. In addition, Road net, residential area, population density, heat resources and so on have some positive effect on the thermal distribution, which increase the local temperature and intensity on the other hand. It is important to study the thermal distribution and its related factors, which contributes to the plan, construction and development of the city.

  • PDF

인체등가형 흉부팬텀과 유리선량계를 이용한 고해상력 및 저선량 CT의 선량측정 (Measurement of Radiation Dose of HR CT and Low Dose CT by using Anthropomorphic Chest Phantom and Glass Dosimetry)

  • 권대철
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.933-939
    • /
    • 2019
  • MDCT에서 인체등가형 흉부팬텀과 유리선량계를 이용하여 고해상력 및 저선량 CT로 검사하여 영상의 평가 및 흡수선량 및 유효선량을 측정하여 임상 기초자료를 제공하는데 목표를 두고자한다. 인체등가형 흉부팬텀내부에 유리선량계를 삽입하여 조직선량을 측정하였다. 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany)과 CARE Dose 4D를 이용하였고, 고해상력 CT에서의 파라메터는 관전압 120 kVp, Eff. mAs 104, scan time 7.93 sec, slice 1.0 mm (Acq. 64×0.6 mm), convolution kernel (B60f sharp)의 스캔 파라메터가 사용되었고, 저선량 CT는 120 kVp, Eff. mAs 15, scan time 7.41 sec, slice 3.0 mm (Acq. 64×0.6 mm), convolution kernel B50f medium sharp의 스캔하였다. 인체등가형 흉부팬텀을 이용하여 스캔에 따른 CTDIvol은 고해상력 CT에서 8.01 mGy, 저선량 CT는 1.18 mGy로 측정되었다. 저선량 CT 검사는 고해상력 CT 검사에 비해 흡수선량이 85.49%가 감소하였고 영상의 차이는 없어 임상에서 유용하게 적용할 수 있다.

IEEE 802.11b 무선 LAN의 MAC 프로토콜을 위한 개선된 충돌 해결 알고리즘 (A Developed Collision Resolution Algorithm in MAC Protocol for IEEE 802.11b Wireless LANs)

  • 판체;박현;김변곤;정경택;전병실
    • 대한전자공학회논문지TC
    • /
    • 제41권6호
    • /
    • pp.33-39
    • /
    • 2004
  • 무선 LAN은 이동중인 사람들이 무선으로 LAN에 연결을 가능하게 해주는 기술이다. 무선 LAN은 고속의 연결과 케이블이나 전화선, 그리고 데스크탑에 종속되지 않고 편리하게 인터넷에 접속할 수 있다. 802.11은 IEEE에서 규정한 무선 LAN의 표준안이다. 이 표준안은 무선에서 LAN에 접속할 수 있도록, 매체접근제어(MAC)와 물리(PHY) 계층을 정의하고 있다. MAC 프로토콜은 PHY 계층에 의존적이며, 공중망을 통해서 사용자 데이터의 전송을 제어한다. 그리고 규모가 큰 네트워크 백본에서 코어 프레이밍 동작과 상호작용을 제공한다. 무선 LAN에서 송은 MAC 프로토콜은 제한된 스펙트럼 리소스를 효율적으로 공유할 수 있고, 동작의 간결성과, 높은 처리율 기능을 제공해야 한다. 높은 데이터 처리율을 갖는 효과적인 MAC 프로토콜을 설계하는 것이 본 논문의 주요 내용이다. 본 논문에서는 무선 LAN에서의 MAC 프로토콜에 적용시키기 위한 Developed Collision Resolution(DCR) 알고리즘을 제안한다. 이 알고리즘은 충돌 해결 속도를 증가시키기 위한 새로운 해법을 제공한다.

Intravenous contrast media application using cone-beam computed tomography in a rabbit model

  • Kim, Min-Sung;Kim, Bok-Yeol;Choi, Hwa-Young;Choi, Yoon-Joo;Oh, Song-Hee;Kang, Ju-Hee;Lee, Sae-Rom;Kang, Ju-Han;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.31-39
    • /
    • 2015
  • Purpose: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. Materials and Methods: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. Results: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Conclusion: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.