• Title/Summary/Keyword: medium-power

Search Result 1,357, Processing Time 0.032 seconds

Dynamic Characteristic of Permanent Magnetic Actuator (영구자석형 액추에이터의 동작 특성)

  • Seo, J.H.;Kim, H.K.;Joo, S.W.;Hahn, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.24-26
    • /
    • 2004
  • For past decade, medium voltage circuit breakers have used the spring-driven mechanical system for interrupting of electric power. However, these mechanisms have many disadvantages of high power consumption, mechanical control components and electrical switching ones for the coil current. Recently, the vacuum interrupter operated by permanent magnet actuator gives outlook on improved characteristic, higher reliability and cost price reduction as well as the feature of simple structure and few components. This paper deals with the dynamic characteristics of permanent magnet actuator used in the medium voltage distribution systems. Coupled finite element method is used to analysis the dynamic characteristics of permanent magnetic actuator and we compared with those of conventional ones.

  • PDF

Insulation Aging Diagnostics of Submarine Medium Voltage Power Cables (배전급 해저케이블의 절연열화진단)

  • Mo, Jong-Myung;Yi, Dong-Young;Song, Kwang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.149-152
    • /
    • 2001
  • In this work, we have conducted insulation aging assessment and maintenance for submarine medium voltage power cable systems to discriminate and maintain bad cables economically. We have found that aging status of submarine cable systems are very poor and in progress. We have found that insulation status were improved with the replacement of cable terminations. We have confirmed with the electrical and structural analysis of terminations, that the poor aging status of cables are mainly caused not by the cable insulations but by the aging of cable terminations. From the above results, we have also confirmed that the domestic diagnostic system is successful and convenient for the discrimination and maintenance of the damaged cables economically.

  • PDF

Chararcteristics of Water Vapor Transmission in Base Resin for Underground Residential Distribution Power Cable (지중배전케이블 기저수지의 수증기 투과 전달특성)

  • Song, Jae-Joo;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.149-153
    • /
    • 2003
  • In URD(Underground Residential Distribution) power cable, experiments of WVT(Water Vapor Transmission) test on the Base Resin accomplished to specimens which contained CB(Carbon Black), anti-oxidant to base resin and made by pressing to resin of pellet or lump form. a kind of specimens was HDPE(High Density Polyethylene), MDPE(Medium Density Polyethylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). as a results of WVT test, we saw that WVT ratio was HDPE < LLDPE < MDPE≒LDPE${\ll}$ PVC. WVT properties of PVC using for jacket showed properties 15-20 times more than MDPE or LLDPE. Therefore, to development of watertightness cable, our works present need of Changing in insulating materials.

  • PDF

Long-Term Evolution of Decaying MHD Turbulence in the Multiphase ISM

  • Kim, Chang-Goo;Basu, Shantanu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.47.1-47.1
    • /
    • 2013
  • Supersonic turbulence is believed to decay rapidly within a flow crossing time irrespective of the degree of magnetization. However, this consensus of decaying magnetohydrodynamic (MHD) turbulence relies on local isothermal simulations, which are unable to investigate the role of global magnetic fields and structures. Utilizing three-dimensional MHD simulations including interstellar cooling and heating, we investigate decaying MHD turbulence within cold neutral medium sheets embedded in warm neutral medium. Early evolution is consistent with previous studies characterized rapid decay of turbulence with the decaying time shorter than a flow crossing time and power-law temporal decay of turbulent kinetic energy with slope of -1. If initial magnetic fields are strong and perpendicular to the sheet, however long term evolutions of kinetic energy shows that a significant amount of turbulent energy still remains even after ten flow crossing times, and decaying rate is reduced as field strengths increase. We analyse power spectra of remaining turbulence to show that incompressible, in-plane motions dominate.

  • PDF

The Development of a Distribution Automation System with an Wireless Network (무선통신망을 이용한 배전자동화시스템 개발 연구)

  • Kim, Myong-Soo;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2747-2749
    • /
    • 2000
  • The KEPRI has been developing the medium/small scale Distribution Automation System(DAS) that adopts wireless transmission media for exchanging information between master and remote terminals. It was concluded that Short Message Service(SMS) of Personal Communication Service(PCS) was the best wireless transmission media for the medium/small scale DAS in the last year. However. we had problem that PCS had long transmission delay. Therefore. SMS phones will be substituted with Radio Link Protocol(RLP) modems having transmission delay less than 5 seconds. This paper describes wireless networks for DAS, practical experience.

  • PDF

A Study on Simulator for Computing Demand Rate Considering a Transformer Capacity (변압기 용량을 고려한 수용률 산출 시뮬레이터 개발에 관한 연구)

  • Kim, Young-Il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.179-185
    • /
    • 2007
  • In this paper, the method of computing demand rate with respect to a transformer capacity is proposed and addressed to predict a future demand rate. The simulation data are taken from switchgears of a real medium voltage transformer. Data taken from the electrical instrument at 22.9 kVY power receiving panels are employed to evaluate the correlation between demand rate and power usage of transformer. It is verified a usefulness with respect to an proposed index of demand rate for transformer by using a least square error of regressive modeling, As a result of investigation and simulation on the spot to a few buildings, it is considered that there is necessity to make a partial amendment of demand rate being applicable currently for electrical energy saving in domestic.

Overmodulation Characteristics of Carrier Based MVPWM for Eliminating the Leakage Currents in Three-Level Inverter (3-레벨 인버터의 누설전류 제거를 위한 캐리어 기반 MVPWM의 과변조 특성)

  • Lee, Eun-Chul;Choi, Nam-Sup;Ahn, Kang-Soon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.509-516
    • /
    • 2015
  • The overmodulation characteristics of a carrier-based medium vector pulse width modulation (CBMVPWM) are examined in this study. CBMVPWM can completely eliminate leakage currents in a three-phase, three-level inverter using only the switching states with the same common mode voltage even in an overmodulation operation. The analytic equations for the magnitude of the output voltage and the switching frequency are derived for overmodulation operation, and the effect of dead time on the leakage current is demonstrated. This study presents the operating principle of CBMVPWM, basic overmodulation features, and simulations and experiments for operating verification.

Comparison of Characteristics of XLPE for Distribution Power Cables (배전케이블용 XLPE의 특성 비교)

  • 서광석;김종은;이건주;김영호;정진수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.9
    • /
    • pp.671-682
    • /
    • 1998
  • Chemical structure and electrical characteristics of 5 commercial crosslinked polyethylenes (XLPE) used as insulating materials for medium voltage distribution power cables in Korea were investigated. It was found that each XLPE shows different properties depending on the type of XLPE. Chemical structural irregularities of pellets change considerably by crossliking reaction, with some irregularities being disappeared after crosslikeng reaction. It was also found through a solvent extraction study that additives such as crosslinking agent and antioxidants act as major source retarding water tree growth. Low molecular weight polyethylene chains plays a different role in water tree growth of XLPE.

  • PDF

Analysis of Dynamic characteristic and design of permanent magnetic actuator (영구자석형 차단기의 특성해석 및 설계)

  • Seo J. H.;Kim H. K.;Joo S. W.;Hahn S. C.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1040-1042
    • /
    • 2004
  • For past decade, medium voltage circuit breakers have used the spring-driven mechanical system for interrupting of electric power. However, these mechanisms have many disadvantages of high power consumption, mechanical control components and electrical switching ones for the coil current. Recently, the vacuum interrupter operated by permanent magnet actuator gives outlook on improved characteristic, higher reliability and cost price reduction as well as the feature of simple structure and few components. This paper deals with the dynamic characteristics of permanent magnet actuator used in the medium voltage distribution systems. Coupled finite element method is used to analysis the dynamic characteristics of permanent magnetic actuator and we compared with those of conventional ones

  • PDF

Smokeless Starting for 4 Cycle Medium Speed Diesel Engine (4행정 중속 디젤기관의 스모크리스 시동)

  • Jung, Suk-Ho
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.11-16
    • /
    • 2014
  • Although smoke emitted from ships is not included in IMO(International Maritime Organiztion) regulation yet, it is one of the substance what is polluting mainly the air. Especially, its concentration is very high when an engine is started and a load is rapidly changed. This is caused by unburned fuel what is injected more than necessary quantity after combustion period. It is possible to decrease smoke concentration emitted at starting engine by controlling fuel injection quantity, but it is concerned that time to rated speed must be spent. Then a governor what can reduce the smoke concentration without a loss of time to rated speed is needed. We adopted a electro-hydraulic governor what can control dual fuel start limit function and achieved very low level of smoke concentration without greater the loss of time to rated speed.