• Title/Summary/Keyword: medium voltage

Search Result 425, Processing Time 0.034 seconds

New 60-Step Inverter System for Medium-to-Large Scale STATCOM (${\cdot}$대용량 STATCOM을 위한 새로운 60-스텝 인버터 시스템)

  • Kim Kiyong;Kim Taehoon;Bae Youngsang;Choi Sewan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.450-456
    • /
    • 2005
  • In this paper new 60-step inverter system for medium-to-large scale STATCOM is proposed and operating principle along with control method is detailed. A simple auxiliary circuit is employed to Improve output voltage waveform of 12-step into 60-step. The proposed scheme could be a cost effective approach in high power application such as 10Mvar to 30Mvar STATCOM. Experimental results from a 2KVA laboratory prototype show validity of the proposed method.

Design and Fabrication of a Seven Segment Decoder/Driver with PMOS Technology (PMOS 집적회로 제작기법을 사용한 Seven Segment Decoder/Driver의 설계와 제작)

  • 김충기;박형규
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.3
    • /
    • pp.11-17
    • /
    • 1978
  • A medium scale integrated circuit, BCD to seven segment decoder/driver is designed and fabricated by employing P-channel metal-oxide-semiconductor technology. The device configuration is specifically designed for a common cathode seven segment LED display unit. The decoder logic is composed of two serially connected read-only-memory matrices and the LED drivers are implemented with wide channel FET's. The fabricated integrated circuit performed successfully with a supply voltage between -7 Volt and -26 Volt and the non-uniformity of the LED segment current is about 10%.

  • PDF

The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable (배전케이블의 수트리 가속열화 후 와이블분포 해석)

  • Kim, Jin-Gook;Lim, Jang-Seob;Song, Il-Gun;Kim, Ju-Yong;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.7-11
    • /
    • 2003
  • for many years already, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented. Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. THTS paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Cable) cable.

  • PDF

Development of Fast Moving Ball Actuator Mode for Novel Electronic-Paper Displays

  • Park, Hyo-Joo;Choi, Hong;Lee, Dong-Hyuck;Kim, Dong-Woo;Bae, Byung-Sung;Kim, We-Yong;Kim, Byung-Uk;Hong, Mun-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.935-936
    • /
    • 2009
  • In this paper, we describe the basic operating mechanism of our novel reflective display, Fast Moving Ball Actuator (FMBA) mode[1], using micro-sized metal coated polymer ball in fluid medium. Metal surface of the ball can be charged up by contact electrode and their locations can be controlled by applied field to obtain optically on and off state. In the medium with high viscosity, the response speed of the moving ball might be reached into their terminal velocity and changed in proportion to the frequency of applied voltage on the electrodes.

  • PDF

The Salt Removal Efficiency Characteristics of Carbon Electrodes Using Fabric Current Collector with High Tensile Strength in a Capacitive Deionization Process (인장강도가 뛰어난 직물집전체를 이용한 탄소전극의 축전식 탈염공정에서의 제염효과)

  • Seong, Du-Ri;Kim, Dae Su
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.466-473
    • /
    • 2020
  • Fabric current collector can be a promising electrode material for Capacitive Deionization (CDI) system that can achieve energy-efficient desalination of water. The one of the most attractive feature of the fabric current collector is its high tensile strength, which can be an alternative to the low mechanical strength of the graphite foil electrode. Another advantage is that the textile properties can easily make shapes by simple cutting, and the porosity and inter-fiber space which can assist facile flow of the aqueous medium. The fibers used in this study were made of woven structures using a spinning yarn using conductive LM fiber and carbon fiber, with tensile strength of 319 MPa, about 60 times stronger than graphite foil. The results were analyzed by measuring the salt removal efficiency by changing the viscosity of electrode slurry, adsorption voltage, flow rate of the aqueous medium, and concentration of the aqueous medium. Under the conditions of NaCl 200 mg/L, 20ml/min and adsorption voltage 1.5 V, salt removal efficiency of 43.9% in unit cells and 59.8% in modules stacked with 100 cells were shown, respectively. In unit cells, salt removal efficiency increases as the adsorption voltage increase to 1.3, 1.4 and 1.5 V. However, increasing to 1.6 and 1.7 V reduced salt removal efficiency. However, the 100-cell-stacked module showed a moderate increase in salt removal efficiency even at voltages above 1.5 V. The salt removal rate decreased when the flow rate of the feed was increased, and the salt removal rate decreased when the concentration of the feed was increased. This work shows that fabric current collector can be an alternative of a graphite foil.

Enhance of Migration and Proliferation of Cells from Tendon Biopsies by High Voltage Pulsed Current Stimulation (고전압맥동전류자극에 의한 생검 건의 세포 이동 및 증식 증진)

  • Lee Jae-Hyoung;Jekal Seung-Joo;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.162-171
    • /
    • 2002
  • The purpose of this study was to examined whether high voltage pulsed current stimulation(HVPCS) enhances the migration and proliferation of fibroblasts from tendon biopsies to provides evidence that the cellular activities of fibroblast are enhanced by HVPCS. Flexor digitorum profundus tendon of chickens were excised, biopsied and cultured in M199 medium for a day. The biopsies through which a cathodal HVPC with 100 pps, 50 V for 30 minutes was passed in medium. A day after treatment, the biopsies embedded in fibrin clot were covered by the addition of 1ml of M199 medium to the well, and placed in the $CO_2$ incubator for the duration of the experiment. The migration distance of cells from tendon biopsies were measured at 6 days after treatment, and proliferation of cells from tendon biopsies were measured at 7 days after treatment. The migration distance of cells from tendon biopsies in the HVPCS group demonstrated significantly greater than the shame treated control group (t=-2.675, p<0.05). Also HVPCS had significantly increased optical density of fibroblasts from tendon biopsies (t=-2.136, p<0.05). These results indicate that the HVPCS with 100pps, 50V for 30minutes enhanced either the migration and proliferation of fibroblast from tendon biopsies. These results supposed that the HVPCS activates cellular responses in fibroblasts from tendon biopsies. This suggests that enhanced the migration and proliferation of fibroblast by HVPCS may be one of the mechanism involved in tendon healing.

  • PDF

Investigation of the Supercritical Fluids as an Insulating Medium for High Speed Switching

  • Shon, Chae-Hwa;Song, Ki-Dong;Oh, Yeon-Ho;Oh, Ho-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1783-1786
    • /
    • 2016
  • The paper investigates the insulation properties of the supercritical $CO_2$ ($SCCO_2$) fluid as an insulating medium for electrical apparatuses. The insulating material is crucial for electrical apparatuses and $SF_6$ gas has been widely used for high power electrical apparatuses. There have been many research efforts to develop substituents for $SF_6$ gas because of high global warming potential. We obtained above 350 kV/mm insulation strength with 12.0 MPa $SCCO_2$. The positive and negative IEC standard pulses are applied between two 10 mm diameter spherical electrodes. The insulation strength of $SCCO_2$ is at least 2.5 times higher than that of $CO_2$ gas at 6.0MPa. The insulation strength of $SCCO_2$ fluid is about 10 times higher than that of $SF_6$ at 0.5MPa which is the ordinary operating pressure of electrical switchgears. Using the result, we expect that the time for switching and dielectric recovery could be reduced using $SCCO_2$ fluid as an insulating medium.

Enhanced fT and fMAX SiGe BiCMOS Process and Wideband Power Efficient Medium Power Amplifier

  • Bae, Hyun-Cheol;Oh, Seung-Hyeub
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.3
    • /
    • pp.232-238
    • /
    • 2008
  • In this paper, a wideband power efficient 2.2 GHz - 4.9 GHz Medium Power Amplifier (MPA), has been designed and fabricated using $0.8{\mu}m$ SiGe BiCMOS process technology. Passive elements such as parallel-branch spiral inductor, metal-insulator-metal (MIM) capacitor and three types of resistors are all integrated in this process. This MPA is a two stage amplifier with all matching components and bias circuits integrated on-chip. A P1dB of 17.7 dBm has been measured with a power gain of 8.7 dB at 3.4 GHz with a total current consumption of 30 mA from a 3 V supply voltage at $25^{\circ}C$. The measured 3 dB bandwidth is 2.7 GHz and the maximum Power Added Efficiency (PAE) is 41 %, which are very good results for a fully integrated Medium PA. The fabricated circuit occupies a die area of $1.7mm{\times}0.8mm$.

Study on of polarity effect on alignment film in transcription-aligned TN-LCD (전사배향 TN-LCD 에서의 배향막의 극성효과에 관한 연구)

  • Kim, Jin-Ho;Seo, Dae-Shik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1812-1814
    • /
    • 1999
  • The effects of polarity of the polymer on transcription-aligned twisted nematic (TN)-liquid crystal display (LCD) on various the polyimide (PI) surfaces were investigated. The monodomain alignment of nematic (N)LC is obtained in cells fabricated by transcription alignment method on PI surface with medium polarity. The LC alignment using transcription alignment method is attributed to polarity of the polymer. The threshold voltage of transcription-aligned TN-LCD decreases with increasing the polarity of the polymer on three kinds of the PI surfaces. The threshold voltage of transcription-aligned TN-LCD on PI surface with high polarity is almost the same compared to rubbing-aligned TN-LCD. The response time of transcription-aligned TN-LCD decreases with the increasing the polarity of the polymer on all PI surfaces. The decay time of transcription-aligned TN-LCD is slow compared with the rubbing-aligned TN-LCD.

  • PDF

Current Decoupling Control for the Three-level PWM Rectifier with a Low Switching Frequency

  • Yuan, Qing-Qing;Xia, Kun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.280-287
    • /
    • 2015
  • Three-level PWM rectifiers applied in medium voltage applications usually operate at low switching frequency to keep the dynamic losses under permitted level. However, low switching frequency brings a heavy cross-coupling between the current components $i_d$ and $i_q$ with a poor dynamic system performance and a harmonic distortion in the grid-connecting current. To overcome these problems, a mathematical model based on complex variables of the three-level voltage source PWM rectifier is firstly established, and the reasons of above issues resulted from low switching frequency have been analyzed using modern control theory. Then, a novel control strategy suitable for the current decoupling control based on the complex variables for $i_d$ and $i_q$ is designed here. The comparisons between this kind of control strategy and the normal PI method have been carried out. MATLAB and experimental results are given in detail.