시간에 따르는 CR장비의 영상의 질평가 (Measurement of Image Quality According to the Time of Computed Radiography System)

  • 손순룡;최관우;김정민;정회원;권경태;황선광;이익표;김기원;정재용;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.365-374
    • /
    • 2015
  • 진단의 높은 정확성을 유지하기 위하여 영상 품질의 정기적인 quality assurance (QA) 검사는 필수적이다. 이 연구의 목적은 2006년부터 2015년까지 시간에 따른 (2006, 2009, 2012, 2015) computed radiography (CR) system의 modulation transfer function (MTF: 변조전달함수), the noise power spectrum (NPS: 잡음전력스펙트럼) and the detective quantum efficiency (DQE: 양자검출효율)를 측정하여 평가 하는 것이다. 우리는 edge method를 이용하여 pre-sampled MTF를 구하였고 international electrotechnical commission standard IEC: 62220-1의 RQA5가 측정에 적용되었으며, X선관 초점으로부터 CR 표면까지의 거리는 150 cm이며, 부가필터 21 mmAl을 사용하였다. 관전압은 $72{\pm}2kVp$였으며 관전압을 1~2 kVp조절하여 HVL이 $7.1{\pm}1mmAl$되도록 하였다. 연구결과는 MTF의 공간주파수 50% ($mm^{-1}$)에서 사용 기간 별로 2006년은 1.54, 2009년은 1.14, 2012년은 1.12, 2015년은 1.38 이었고 공간주파수 10% ($mm^{-1}$)에서 사용 기간 별로 2006년은 2.68, 2009년은 2.44, 2012년은 2.44, 2015년은 2.46 이었다. 각각의 노이즈 분포는 2006년이 가장 낮은 노이즈 분포를 보였으며 2015, 2009, 2012 순으로 낮은 노이즈 분포를 나타내었다. Peak DQE와 $1mm^{-1}$에서도 2006년이 가장 우수한 DQE를 보였으며 2015년, 2009년, 2012년 순으로 DQE값을 나타내었다. 정확한 진단을 위하여 주기적인 CR 시스템의 유지보수가 필요하며 본 연구는 CR 시스템의 QA 및 수행성능 평가에 기초가 될 것으로 생각된다.

방사선학과 교육과정 개선을 위한 현 교육과정 평가 (Evaluation of Present Curriculum for Devlopment of Dept. of Radiological Science Curriculum)

  • 강세식;김창수;최석윤;고성진;김정훈
    • 한국콘텐츠학회논문지
    • /
    • 제11권5호
    • /
    • pp.242-251
    • /
    • 2011
  • 시대와 사회적인 변화에 따라서 교육과정은 변화의 요구를 받게 된다. 교육과정의 변화를 요구받는 현시점에서 교과과정을 개선하기 위한 선행단계인 현재의 교과과정을 분석, 평가하고자 한다. 교육전문가 집단의 설문과 현재 방사선학과가 개설되어 있는 21개 대학 중 19개 대학 방사선학과의 교육과정 및 참고문헌을 중심으로 연구하였으며, 연구내용은 방사선사 업무범위와 교과과정, 방사선과학 교육과 교과과정, 디지털과 국제화시대의 교과과정, 방사선과학에 대한 학문적인 발전과 교과과정 등의 내용을 중심으로 연구하였다. 업무범위에서는 혈관조영학 및 중재적검사학은 6 ~ 8개교, 투시영상학은 4개교, 초음파영상학 및 실습은 6개교, 자기공명영상학은 2개교 등에서 미개설된 것으로 나타났다. 기초의학 교과목인 인체생리학, 인체해부학 및 실습, 의학용어 등은 대부분의 대학에서 개설되어 있었으나, 병리학 5개교, 영상해부학 6개교, 임상의학 11개교 등에서 미개설 되어 있는 것으로 나타났다. 기초이공학 교과목 중에서 일반생물학 및 실습은 11개교, 일반물리학 및 실습은 14개교, 일반화학 및 실습은 8개교 등 약 절반정도의 대학에서 개설된 것으로 나타났다. 전공기초에서 디지털화 교과목인 보건전산학, 컴퓨터프로그램밍, PACS 등이 개설된 대학은 4 ~ 5개교에 불과하였다. 방사선과학 교육은 확대된 업무범위를 포함하여, 방사선과학의 학문적 발전과 디지털화 교육 및 국제화 그리고 방사선과학 분야의 미래지향적인 교육의 토대를 마련하기 위해서는 현재 각 대학에서 개설, 운영되고 있는 교과과정은 일정부분 표준화의 필요성을 인식하였으며, 이에 방사선학과 교육과정은 인증제 도입의 필요성을 제시한다.

수면 무호흡 증후군에서 지속적 양압 치료시의 최적압 및 그 도달기간 (Nasal Continuous Positive Airway Pressure Titration and Time to Reach Optima1 Pressure in Sleep Apnea Syndrome)

  • 이관호;이현우
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권1호
    • /
    • pp.84-92
    • /
    • 1995
  • 연구배경: 수면무호흡증후군은 호흡정지로 인한 저산소혈증때문에 심 폐부전, 말초혈관 기능장애 혹은 중추신경질환을 유발할 수 있을 뿐만 아니라 갑작스런 사망을 일으킬 수 있는 질환으로 조기진단 및 적절한 치료가 요구된다. 현재까지는 지속적 기도양압 치료가 가장 효과적인 치료법으로 알려져 있으나, 최적양압을 구하기 위하여는 검사자나 환자의 시간과 노력 그리고 경제적 손실이 많은 실정이다. 저자들은 지속적 기도 양압 치료시의 최적양압에 도달하는 시간을 파악하여 전통적 수면다원화검사 및 양압처방에 소요되는 시간과 노력 그리고 경제적 손실을 줄여 보고자한다. 방법: 수면무호흡증후군 환자에서 진단 및 치료적 수면다원화검사를 실시하며 최적 지속적 기도양압은 2Cm $H_2O$부터 시작하여 무호흡이 정상화되고 최저산소포화도가 향상될 때까지 증가시켜 최적압 도달까지 걸린 시간을 측정 분석하였다. 결과: 1) 지속적 기도양압 치료시 치료전보다 총수면시간, 효과적인 수면시간은 유의한 차이가 없었으나, REM 수면, REM 수면에 도달하는 시간, 무호흡지수, 무호흡 저호흡지수, 최저산소포화도는 의의있게 호전되었다. 2) 평균 최적 지속적 기도양압은 $7.7{\pm}2.9Cm\;H_2O$였고, 이 최적압에 도달하는데 걸리는 시간은 $151.5{\pm}91.3$분이었다. 3) 대상환자들의 33%에서 최적압에 도달하는데 4시간 이상이 소요되었으며, 최적압 도달후 다시 압조정이 필요하였던 경우는 60(47%)예 였고, 나머지 67(53%)예에서는 더 이상의 압조정이 필요없이 처음의 최적압으로 효과가 있었다. 결론: 최적 지속적 기도양압치에 도달하는데 환자의 약 1/3에서 4시간 이상 걸리는 것으로 보아 split night CPAP titration 방법은 수정되어져야 할 것으로 생각되며, nap study시의 2~3시간은 적절한 CPAP titration을 하기에는 불충분할 것으로 생각된다.

  • PDF

보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究) (Survery on Business of the Departments of Radiology in Health Centers)

  • 최종학;전만진;허준;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교 (Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 손순룡;최관우;정회원;권경태;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.99-105
    • /
    • 2016
  • 잡음전력스펙트럼 (noise power spectrum, NPS)는 noise 진폭의 측정과 균일한 방사선 영역으로부터 획득된 영상의 품질에 가장 일반적인 방법 중 하나이다. 이 연구의 목적은 megavoltage X-ray 에너지를 사용하여 다른 잡음 전력스펙트럼 방법론들을 비교하는 것이다. 진단 영역에서의 잡음전력스펙트럼 평가 방법들은 국제 전기 규격 international electro-technical commission(IEC 62220-1) 기준을 사용하여 치료 영역에 적용되었다. 우리가 사용한 전자포털영상장치(electronic portal imaging device, EPID)는 Varian TrueBeam$^{TM}$, Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT 그리고 Varian Clinac$^R$ iX aS1000이었다. 잡음전력스펙트럼의 관심영역을 측정하기 위해, 우리는 겹침 (overlapping), 비겹침 (non-overlapping), 평탄도 (flatness), 반음영 (penumbra) 4가지 인자를 사용하였다. 결과적으로는 Siemens BEAMVIEW$^{PLUS}$, Varian TrueBeam$^{TM}$ flattening filter, Varian Clinac$^R$ iX aS1000, Varian TrueBeam$^{TM}$ flattening filter free에서의 잡음 (noise) 분포는 기존의 첫번째, 두번째, 세번째 실험방법보다는 Elekta iViewGT보다 현격하게 높은 noise 분포가 나타남을 알 수 있다. 이번 연구는 다양한 인자들이 잡음전력스펙트럼의 megavoltage imaging (MVI)영상에서 MVI영역에서 잡음전력 스펙트럼의 기준의 방법론으로 사용되어질 수 있다는 것을 보여주었다.

PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구 (A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT)

  • 김빛나;조석원;이주영;유광열;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.23-30
    • /
    • 2015
  • 양전자 방출핵종은 511 keV의 감마선을 방출하기 때문에 기존 140 keV의 99mTc에 비해 종사자의 방사선 피폭의 증가로 피폭선량 저감을 위한 노력이 요구된다. 본 연구는 환자에게로부터 일정거리에 따른 선량률 변화를 확인하고 차폐를 이용하여 외부선량률의 변화를 알아보았으며 환자 주변의 외부선량 분포에 대한 영 향을 분석하여 방사선 종사자의 피폭 관리에 도움이 되고자 하였다. 10 명의 환자를 대상으로 하였으며 평균연령은 $47.7{\pm}6.6$ 세였다. 환자의 키는 평균 $165.5{\pm}3.8cm$, 몸 무게 평균은 $65.9{\pm}1.4kg$으로 비슷한 몸무게의 환자를 대상으로 하였다. 머리, 가슴, 복부, 무릎, 발끝 쪽의 위치에서 10 cm, 50 cm, 100 cm, 150 cm, 200 cm 위치에서 측정하였고 측정 후에 즉시 이동형 방사선 차폐체을 설치한 후 머리와 가슴, 복부 부분에서 100 cm, 150 cm, 200 cm 거리에서 선량률을 측정하였다. 거리에 따른 선량률 변화와 차폐 전, 후의 투과율을 구하였다. 평균 10 cm 거리에서는 머리 부분이 $105.40{\mu}Sv/h$로 가장 높게 나타났으며 발 부분에서 $15.85{\mu}Sv/h$로 가장 낮게 나타났다. 200 cm 거리에서는 머리, 가슴, 복부 부분에서 비슷한 선량률이 나타났다. 머리 부분에 서 차폐 전 100 cm에서 $9.56{\mu}Sv/h$, 150 cm에서 $5.23{\mu}Sv/h$, 200 cm에서 $3.40{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, $1.27{\mu}Sv/h$로 측정되었다. 가슴 부분에 서 차폐 전 100 cm에서 $8.54{\mu}Sv/h$, 150 cm에서 $4.90{\mu}Sv/h$, 200 cm에서 $3.44{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, $1.13{\mu}Sv/h$로 측정되었다. 복부 부분에 서 차폐 전 100 cm에서 $9.83{\mu}Sv/h$, 150 cm에서 $5.15{\mu}Sv/h$, 200 cm에서 $3.18{\mu}Sv/h$로 나타났으며 차폐 후에는 100 cm, 150 cm, 200 cm 에서 각각 $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, $1.23{\mu}Sv/h$로 측정되었다. 투과율은 거리에 따라 증가함을 알 수 있었다. 거리가 멀어질수록 선량율이 낮아지는 것을 확인할 수 있었으며 차폐를 하였을 경우 차폐를 하지 않았을 때보다 1 / 4 정도 더 낮아지는 것을 확인할 수 있었다. 검사를 진행하는 근무자는 환자와의 거리를 멀리 할 수 없기 때문에 방사선 피폭이 증가할 수밖에 없다. 따라서 적절한 차폐를 한다면 방사선 종사자의 방사선 피폭을 줄 일 수 있을 것이다.