• Title/Summary/Keyword: medical radiation exposure

Search Result 610, Processing Time 0.023 seconds

Endonuclease G is Upregulated and Required in Testicular Germ Cell Apoptosis after Exposure to 60 Hz at 200 μT

  • Park, Sungman;Kim, Min-Woo;Kim, Ji-Hoon;Lee, Yena;Kim, Min Soo;Lee, Yong-Jun;Kim, Young-Jin;Kim, Hee-Sung;Kim, Yoon-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.142-150
    • /
    • 2015
  • Several reports supported that continuous exposure to 60 Hz magnetic field (MF) induces testicular germ cell apoptosis in vivo. We recently evaluated duration- and dose-dependent effects of continuous exposure to a 60 Hz MF on the testes in mice. BALB/c male mice were exposed to a 60 Hz MF at $100{\mu}T$ for 24 hours a day for 2, 4, 6, or 8 weeks, and at 2, 20 or $200{\mu}T$ for 24 hours a day for 8 weeks. To induce the apoptosis of testicular germ cell in mice, the minimum dose is $20{\mu}T$ at continuous exposure to a 60 Hz MF for 8 weeks, and the minimum duration is 6 weeks at continuous exposure of $100{\mu}T$. Continuous exposure to a 60 Hz MF might affect duration- and dose-dependent biological processes including apoptotic cell death and spermatogenesis in the male reproductive system of mice. The safety guideline of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) indicates that the permissible maximum magnetic flux density for general public exposure is $200{\mu}T$ at 60 Hz EMF (ICNIRP Guidelines, 2010). In the present study, we aimed to examine the expression of pro- and anti-apoptotic genes regulated by the continuous exposure to 60 Hz at $200{\mu}T$ in Sprague-Dawley rats for 20 weeks. The continuous exposure to 60 Hz at $200{\mu}T$ does not affect the body and testicular weight in rats. However, exposure to 60 Hz MF significantly affects testicular germ cell apoptosis and sperm count. Further, the apoptosis-related gene was scrutinized after exposure to 60 Hz at $200{\mu}T$ for 20 weeks. We found that the message level of endonuclease G (EndoG) was greatly increased following the exposure to 60 Hz at $200{\mu}T$ compared with sham control. These data suggested that 60 Hz magnetic field induced testicular germ cell apoptosis through mitochondrial protein Endo G.

Protection of Radiation induced Somatic Damage by the Reduction of Oxidative Stress at Critical Organs of Rat with Naringenin Administration

  • Park, Ji Eun;Kang, Seong Hee;Kim, Hyun Mi;Kim, Suk Hee;Kang, Bo Sun
    • The Korean Journal of Food And Nutrition
    • /
    • v.29 no.6
    • /
    • pp.829-834
    • /
    • 2016
  • Free radicals originate due to the radiolysis of cytoplasmic water with low "Linear Energy Transfer" (LET) radiations. Naringenin (Ng) is a natural antioxidative compound found in citrus fruits. This study revealed that Naringenin (Ng) reduced the radiation damage of critical organs by scavenging oxidative free radicals. In the study, Ng was orally administrated to rats daily for 7 consecutive days, prior to whole body exposure to gamma-rays. The scavenging efficacy was evaluated biochemically by measuring the concentration of cytotoxic byproducts and the activity of enzymes relevant to oxidative free radicals, after extracting the organs from the exposed rat. We observed increased levels of malondialdehyde (MDA) concentration, and decrease in the activities of superoxide dismutase (SOD) and catalase (CAT) in the exposed control group. However, pretreatment with Ng significantly reduced the MDA concentration, and increased the activities of SOD and CAT, as compared to the control group, due to the free radical scavenging by Ng. The results indicate that Ng administration prior to irradiation could protect critical organs from radiation damage.

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

How to Choose and Use the CBCT (임상가를 위한 특집 1 - CBCT의 선택과 처방)

  • An, Chang-Hyeon
    • The Journal of the Korean dental association
    • /
    • v.52 no.3
    • /
    • pp.132-138
    • /
    • 2014
  • The emergence of Cone Beam Computed Tomography(CBCT) in the late 1990s represented an innovative advancement in the field of dental and maxillofacial radiology because it greatly reduced the radiation exposure to patients and offered 3D images easily. The 3D information generated by this technique brings the potential of improved diagnosis and treatment planning for a wide range of clinical applications in dentistry. The use of CBCT includes diagnosis and surgical assessment of the orofacial hard tissue lesions, dental implant treatment planning and postoperative evaluation, TMJ assessment, diagnosis of craniofacial fracture, orthodontics, endodontics, and so on. All CBCT examinations should be justified on an individualized needs. The clinical benefits to the patient for each CBCT scan must outweigh the potential risks associated with exposure to ionizing radiation. CBCT scans should be taken with initially obtained medical and dental histories of patients and a close clinical examination. CBCT should be considered as an imaging alternative of other conventional radiography in cases where the anatomical structures of interest may not be seen. The smallest possible field of view(FOV) and the lowest setting of tube current and scan time should be chosen, and the entire images scanned should be interpreted by a qualified expert.

Compositional Qualification of Radiation Protection in Neutron Radiotherapy Room with KCCH Cyclotron (원자력병원(原子力病院) 싸이클로트론 중성자선(中性子線) 치료실(治療室)의 방사선(放射線) 방어(防禦)에 관한 총합적(總合的) 평가(評價))

  • Yoo, Seong-Yul;Cho, Chul-Koo;Koh, Kyoung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.45-50
    • /
    • 1989
  • Radiation exposure of the personnel in the neutron therapy facility of KCCH cyclotron neutron system is discussed. In neutron therapy room, medical personnel is exposed to photons of the remanent induced radioactivity from the isocentric gantry in which targets and collimators are mounted. The radiation level of the neutron therapy room of KCCH cyclotron was acceptable and it decreased immediately after beam off. Personal exposure measured by individual monitor was far less than permissible level.

  • PDF

STUDY ON ENTRANCE SKIN DOSE AT PANORAMIC RADIOGRAPHY IN INCHEON, KOREA

  • Choi, Jung-Hyun;Kim, Sung-Chul;Han, Dong Kyoon
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.182-186
    • /
    • 2014
  • Recently, the use of panoramic radiography has shown a constant increase, and significant research is underway. However, radiation exposure attracts less attention in dental radiography than in other types of radiography. We used an OSLD for measurement of the entrance skin dose in eyeballs and the thyroid region, both of which are not covered by examinations but are included in radiographical regions and are sensitive to radiation, as well as orally in Incheon and reported the results. The entrance skin dose was 0.0282 mSv on average for the oral region, and 0.0259 mSv on average for the eyeball, and 0.0261mSv on average, for thyroid gland. While there is no proper shielding method for the eyeball, a thyroid protector is not used by most hospitals and most hospitals are equipped with an apron and a thyroid protector separately; thus, it is necessary to use an integration of an apron and a thyroid protector and medical device manufacturers need to develop a method for controlling the length of the slit in the slit-type area of radiation occurrence in order to reduce unnecessary exposure.

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

DR Responses to X-Ray: in Terms of Absorbed Energy

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Ho, Dong-Su;Suh, Tae-Suk;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.389-392
    • /
    • 2002
  • Digital radiography (DR) is being developed for numerous applications in medical imaging. For understanding DR image, it is necessary to comprehend DR responses to X-ray in terms of absorbed energy. This study reports on the relationship of absorbed energy in the scintillator vs. pixel value of detector. Pixel value and exposure were measured from 50 kVp to 120 kVp until the detector was saturated. For representing radiation produced at the X-ray tube, we used program Srs-78 and compared experimental exposure with calculated exposure. Absorbed energy was acquired using spectrum and we got the relation between the two values.

  • PDF

Projected lifetime cancer risk from cone-beam computed tomography for orthodontic treatment

  • Jha, Nayansi;Kim, Yoon-Ji;Lee, Youngjun;Lee, Ju Young;Lee, Won Jin;Sung, Sang-Jin
    • The korean journal of orthodontics
    • /
    • v.51 no.3
    • /
    • pp.189-198
    • /
    • 2021
  • Objective: To estimate the projected cancer risk attributable to diagnostic cone-beam computed tomography (CBCT) performed under different exposure settings for orthodontic purposes in children and adults. Methods: We collected a list of CBCT machines and their specifications from 38 orthodontists. Organ doses were estimated using median and maximum exposure settings of 105 kVp/156.8 mAs and 130 kVp/200 mAs, respectively. The projected cancer risk attributable to CBCT procedures performed 1-3 times within 2 years was calculated for children (aged 5 and 10 years) and adult (aged 20, 30, and 40 years) male and female patients. Results: For maximum exposure settings, the mean lifetime fractional ratio (LFR) was 14.28% for children and 0.91% for adults; this indicated that the risk to children was 16 times the risk to adults. For median exposure settings, the mean LFR was 5.25% and 0.58% for children and adults, respectively. The risk of cancer decreased with increasing age. For both median and maximum exposure settings, females showed a higher risk of cancer than did males in all age groups. Cancer risk increased with an increase in the frequency of CBCT procedures within a given period. Conclusions: The projected dental CBCT-associated cancer risk spans over a wide range depending on the machine parameters and image acquisition settings. Children and female patients are at a higher risk of developing cancer associated with diagnostic CBCT. Therefore, the use of diagnostic CBCT should be justified, and protective measures should be taken to minimize the harmful biological effects of radiation.

Automatic Exposure Control Performance Evaluation of Digital Radiographic Imaging System by Manufacturer Using Coins (동전을 이용한 제조사 별 디지털 방사선 영상 시스템의 자동노출제어 성능 평가)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, we proposed an image quality control for an automatic exposure control (AEC) of digital radiographic imaging system and tried to analyze the performance of the AEC by various manufacturer. The subjects of the experiment were analyzed for the AEC image quality evaluation using digital radiation generators from four manufacturer such as PHILIPS, GE Healthcare, SAMSUNG Healthcare, DK Medical Solution. We used as materials for the implementation of the image quality evaluation by coins (500 won, KOMSCO, Korea). This study evaluated the performance evaluation of the AEC as image quality and exposure dose (Milliampere-seconds; mAs). The image quality evaluation was tried visual assessment by two radiologic technologists and contrast to noise (CNR) by ImageJ. The exposure dose investigated mAs on digital radiation generators. The radiographic coin images acquired 360 images based on change in the control factors of the AEC, which were kVp, the consistency of field configuration and dominant zone, sensitivity and density. As a result, there was a significant difference in the AEC performance between manufacturer. The CNR by the AEC for each manufacturer showed a difference of up to about 1.9 times. The exposed tube current by the AEC for each manufacturer showed a difference of up to about 5.8 times. It is expected that our proposed evaluation method using coins could be applied as the AEC performance evaluation method in the future.