• Title/Summary/Keyword: medical monitoring

Search Result 1,606, Processing Time 0.039 seconds

The effects of circadian disturbances induced by night shifts on the mouse peripheral tissues

  • Seo, Dong-Hyun;Kim, Han-Sung;Ko, Chang-Yong;Schreiber, Jurgen;Jang, Yeong-Su;Bae, Kiho
    • Animal cells and systems
    • /
    • v.16 no.5
    • /
    • pp.357-365
    • /
    • 2012
  • We have examined the effect of circadian disturbances induced by night shifts (NSs) on the phenotypes of the tibiae and abdominal adipose tissues (ADTs) in a mouse model by using in vivo micro-computed tomography (micro-CT). We found that the volumes of total and visceral ADTs in the night-shifted group of mice were significantly larger (69 and 92%, respectively) than those in the control. The mean polar moment of inertia, cross-sectional thickness, and bone mineral density of the cortical bone in the night-shifted group of mice were less (13, 5, and 3%, respectively) than those in the control. Moreover, the volume and the thickness of growth plates (GPs) of the tibiae in the night-shifted mice were significantly smaller (22 and 20%, respectively) than those in the control. Taken together, our results indicate that disturbances in the mouse circadian rhythms induced by NSs affect the morphological characteristics of cortical bone, the volume and the thickness of GPs, and the volume of ADTs.

Implementation of A Hospital Information System in Ubiquitous and Mobile Environment

  • Jang, Jae-Hyuk;Sim, Gab-Sig
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.12
    • /
    • pp.53-59
    • /
    • 2015
  • In this paper, we developed a Hospital Information System in which the business process is formalized and a wire/wireless integrated solution is used. This system consists of the administration office program, the medical office program, the ward management program and the rounds management program. The administration office program can enroll and accept patients, issue and reissue the RFID card. The medical office program inputs a medical examination and treatment, outputs a diagnosis, requests a hospitalization, retrieves the record of a medical examination and treatment, assigns the corresponding examination room to the accepted patients, and updates the number of an waiting patient and a patient number according to the examination room on real time. The ward management program handles hospitalizations and leaving hospital, a nurse's note, and an isolation ward monitoring. The rounds management program handles a medical examination and treatment, and a leaving hospital using PDA. This developed system can be built at low cost and increase the quality of the medical services highly by making it automated the medical administration automation. Also the small number of the medical staffs can manage the inpatients efficiently by using the monitoring functions.

Geohashed Spatial Index Method for a Location-Aware WBAN Data Monitoring System Based on NoSQL

  • Li, Yan;Kim, Dongho;Shin, Byeong-Seok
    • Journal of Information Processing Systems
    • /
    • v.12 no.2
    • /
    • pp.263-274
    • /
    • 2016
  • The exceptional development of electronic device technology, the miniaturization of mobile devices, and the development of telecommunication technology has made it possible to monitor human biometric data anywhere and anytime by using different types of wearable or embedded sensors. In daily life, mobile devices can collect wireless body area network (WBAN) data, and the co-collected location data is also important for disease analysis. In order to efficiently analyze WBAN data, including location information and support medical analysis services, we propose a geohash-based spatial index method for a location-aware WBAN data monitoring system on the NoSQL database system, which uses an R-tree-based global tree to organize the real-time location data of a patient and a B-tree-based local tree to manage historical data. This type of spatial index method is a support cloud-based location-aware WBAN data monitoring system. In order to evaluate the proposed method, we built a system that can support a JavaScript Object Notation (JSON) and Binary JSON (BSON) document data on mobile gateway devices. The proposed spatial index method can efficiently process location-based queries for medical signal monitoring. In order to evaluate our index method, we simulated a small system on MongoDB with our proposed index method, which is a document-based NoSQL database system, and evaluated its performance.

A study on WSN based ECG and body temperature measuring system for ubiquitous healthcare: 2. Vital signal monitoring software system (유비쿼터스 헬스케어를 위한 센서 네트워크 기반의 심전도 및 체온 측정 시스템: 2. 생체신호 모니터링 소프트웨어 시스템)

  • Lee, Dae-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.417-424
    • /
    • 2006
  • An ubiquitous healthcare monitoring system for elderly person at home was designed for continuous healthy monitoring of elderly person or patients. Human vital signals, such as ECG and body temperature, were monitored by terminal PC or PDA via ECG and temperature sensor nodes on the patient's body. From the ECG data, the heart rate, tachycardia, bradycardia and arrhythmia were diagnosed on the terminal PC or PDA to assist doctor's or nurse's aid or patient itself to monitor the patient's condition and give medical examination. Artificial judgement support system was designed in server computer and the system support a doctor or nurser for management or treatment of the patient. This system can be applied to vital signal monitoring system for solitude elderly person at self house or home health care service part. And this ubiquitous healthcare system can reduce the medical expenses in coming aging or aged society.

Clinical Significance of Urinalysis with Test Strips (복합시험지법(複合試驗紙法)에 의한 이상뇨(異常尿) 검사(檢査)의 임상적(臨床的) 의의(意義))

  • Sohn, Tai-Hyu
    • The Journal of the Korean life insurance medical association
    • /
    • v.2 no.1
    • /
    • pp.75-81
    • /
    • 1985
  • Urine contains protein and nucleic acid(urea, uric acid, creatinine, ammonia, amino acids), various organic and inorganic materials, vitamin, hormone, enzyme etc. The examination of gualitative or quantitative change of the above mentioned materials and picking up the abnormal materials are useful to diagnose diseases. The test strip for examination of urine is applied to the routine test, monitoring of medical therapy and recurrence, self monitoring, and screeing in preventive medicine. We have been using multitest strip for checking the bacterial infection(nitrite), PH, protein, glucose, ketone body, urobilinogen, bilirubin and occult blood. So it is possible to diagnose three groups of diseases as follows, abnormal metabolism of the carbohydrate, diseases of kidney and other urogenital system, diseases of hepatobiliary system and hemolytic disease causing abnormal metabolism of bile juice.

  • PDF

Tentative diagnosis and monitoring using ultrasound in a cat with pansteatitis: a case report

  • Kang, Hyesun;Noh, Daji;Lee, Sang-Kwon;Lee, Kija
    • Korean Journal of Veterinary Research
    • /
    • v.62 no.1
    • /
    • pp.7.1-7.4
    • /
    • 2022
  • A 7-year-old Scottish Straight cat presented with hypersalivation and generalized hyperesthesia. The cat was provided tuna-based food for 2 to 3 weeks before clinical symptoms appeared. Abdominal ultrasonography showed a heterogeneous, hyperechoic mesentery with hypoechoic foci. Pansteatitis was tentatively diagnosed and the cat was treated with vitamin E, anti-inflammatory drugs, and dietary changes. The clinical signs and changes in mesenteric fat on serial ultrasonography resolved. After feeding tuna-based food again, the same clinical signs and mesenteric changes on ultrasound recurred, which recovered through the same treatment. This study suggests that ultrasonography can be useful for diagnosis and monitoring of feline pansteatitis.

The Experience in Dose Measurement of IVR with Glass Dosimeter System

  • Nishizawa, Kanae;Moritake, Takashi;Iwai, Kazuo;Matsumaru, Yuji;Tsuboi, Koji;Maruyama, Takashi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.269-271
    • /
    • 2002
  • It is reported that exposure for the patient and the medical staff from IVR is large. Direct measurement of patient exposure is difficult, since the measurement disturbs reading of images. The fluorescence glass-dosimeter system consisting of small-size glass chips is developed in recent years. Owing to its small size and physical characteristics, direct monitoring of surface dose may be feasible. The dose measurement for patient and medical staff during head interventional radiology (IVR) examinations was tried by using the fluorescence glass-dosimeter system. A dose response of the glass dosimeter is almost linear in large dose range but its energy dependency is high. About 20% variation of sensitivity was observed in the effective energy of 45-60keV which was used in IVR. In spite of this shortcoming, the fluorescence glass-dosimeter system is a convenient means for a dose monitoring during IVR performance.

  • PDF

Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device (생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Kim, Seong-Hoo;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.