• 제목/요약/키워드: medical monitoring

검색결과 1,594건 처리시간 0.025초

Successful Motor Evoked Potential Monitoring in Cervical Myelopathy : Related Factors and the Effect of Increased Stimulation Intensity

  • Shim, Hyok Ki;Lee, Jae Meen;Kim, Dong Hwan;Nam, Kyoung Hyup;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.78-87
    • /
    • 2021
  • Objective : Intraoperative neurophysiological monitoring (IONM) has been widely used during spine surgery to reduce or prevent neurologic deficits, however, its application to the surgical management for cervical myelopathy remains controversial. This study aimed to assess the success rate of IONM in patients with cervical myelopathy and to investigate the factors associated with successful baseline monitoring and the effect of increasing the stimulation intensity by focusing on motor evoked potentials (MEPs). Methods : The data of 88 patients who underwent surgery for cervical myelopathy with IONM between January 2016 and June 2018 were retrospectively reviewed. The success rate of baseline MEP monitoring at the initial stimulation of 400 V was investigated. In unmonitorable cases, the stimulation intensity was increased to 999 V, and the success rate final MEP monitoring was reinvestigated. In addition, factors related to the success rate of baseline MEP monitoring were investigated using independent t-test, Wilcoxon rank-sum test, chi-squared test, and Fisher's exact probability test for statistical analysis. The factors included age, sex, body mass index, diabetes mellitus, smoking history, symptom duration, Torg-Pavlov ratio, space available for the cord (SAC), cord compression ratio (CCR), intramedullary increased signal intensity (SI) on magnetic resonance imaging, SI length, SI ratio, the Medical Research Council (MRC) grade, the preoperative modified Nurick grade and Japanese Orthopedic Association (JOA) score. Results : The overall success rate for reliable MEP response was 52.3% after increasing the stimulation intensity. No complications were observed to be associated with increased intensity. The factors related to the success rate of final MEP monitoring were found to be SAC (p<0.001), CCR (p<0.001), MRC grade (p<0.001), preoperative modified Nurick grade (p<0.001), and JOA score (p<0.001). The cut-off score for successful MEP monitoring was 5.67 mm for SAC, 47.33% for the CCR, 3 points for MRC grade, 2 points for the modified Nurick grade, and 12 points for the JOA score. Conclusion : Increasing the stimulation intensity could significantly improve the success rate of baseline MEP monitoring for unmonitorable cases at the initial stimulation in cervical myelopathy. In particular, the SAC, CCR, MRC grade, preoperative Nurick grade and JOA score may be considered as the more important related factors associated with the success rate of MEP monitoring. Therefore, the degree of preoperative neurological functional deficits and the presence of spinal cord compression on imaging could be used as new detailed criteria for the application of IONM in patients with cervical myelopathy.

고출력 레이저 치료를 통한 근강직 완화의 실시간 모니터링 연구 (Development of Real-time Monitoring System for Muscle Tension by High Intensity Laser Therapy)

  • 홍정선;윤종인
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권3호
    • /
    • pp.128-134
    • /
    • 2012
  • Currently, high-intensity laser therapy (HILT) is increasingly used in various muscle disorders like muscle tension. Our proposed study includes the development of the real-time monitoring system using a myotonometer for HILT. The developed system consists of a piezoelectric sensor and laser distance sensor for muscle stiffness monitoring during the treatments. The results demonstrated that the level of muscle tension was rapidly decreased after 3 minutes of the high-intensity laser treatment when compared to the control group. The combined HILT and realtime muscle tension monitoring system may help to evaluate the therapeutic procedure and efficient treatments for various muscle pains.

휴대용 심전도 측정기와 스마트 기기 기반의 심건강 모니터링 및 위험도 알림 시스템 (Portable Electrocardiograph and Smart Device-based Heart Health Monitoring and Risk Notification System)

  • 조진수
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.73-78
    • /
    • 2013
  • This paper proposes a portable electrocardiograph and smart device-based heart health monitoring and risk notification system. The proposed system consists of a portable electrocardiograph and a smart device for a system user, and a web-based monitoring system for observers. This system can improve the convenience and efficiency of measurement by using a light-weight portable electrocardiograph and a smart device. In addition, any authorized person such as caregiver or family member who is not related to medical institution can monitor users'heart health in real-time using the web-based monitoring system. Therefore, a user and authorized remote observers can efficiently monitor and manage user's heart health in daily-life even without any medical institution's help, and can preemptively deal with any possible dangerous situations, such as degeneration of a cardiac disorder and sudden cardiac death.

Monitoring system technology of patients' lifestyles

  • Hahn, James
    • 한국인공지능학회지
    • /
    • 제2권1호
    • /
    • pp.4-6
    • /
    • 2014
  • These days, aging, the aged and patients rapidly increased to produce problems, for instance, rapid increase of demand on medical service, higher medical expenses, low quality of the elderly's lives, shortage of physicians and nurses, and others [1]. These days, not only IT technology but also medical technology has taken the lead in settlement of the problems. Patients see a doctor to be given medical treatment and service when they are sick to have difficulty. The study investigated lifestyle monitoring system of chronic disease patients to indicate variation depending upon time. The health care is likely to solve problems of the elderly and chronic disease patients and to satisfy desire of better life quality by living healthy life and to diagnose diseases and give medical treatment and to give solutions in accordance with changes of paradigm of medical services.

Intra-operative Neurological Monitoring and Anesthesia

  • Park, Sang-Ku;Lim, Sung-Hyuk;Park, Chan-Woo;Park, Jin-Woo;Kim, Dong-Jun;Kang, Ji-Hyuk;Jee, Hyo-Geun;Kim, Gi-Bong
    • 대한임상검사과학회지
    • /
    • 제44권4호
    • /
    • pp.184-198
    • /
    • 2012
  • The purpose of intra-operative neurological monitoring (INM) is to minimize surgically induced nerve damage, sensory nerves and motor neurons without affecting the operations to proceed during surgery such as evoked potentials (EP), electromyography (EMG), electroencephalography (EEG), transcranial doppler (TCD), etc. During the course of checking a patient's condition, surveillance of ambulatory patients is a very different thing to check if the test is done under general anesthesia. INM can be possible or impossible depending on the type of drugs used and their concentrations because the monitoring is performed under anesthesia. Therefore, it is emphasized on the necessity of reviewing anesthesia which influences on INM.

  • PDF

자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발 (A Simulator for the Validation of Non-invasive Blood Pressure (NIBP) Monitoring Devices)

  • 도일;임현균;안봉영;지영준;이종실;오재훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권3호
    • /
    • pp.111-115
    • /
    • 2017
  • Blood pressure is one of the important vital signs for monitoring the medical condition of a patient. Automated NIBP(non-invasive blood pressure) monitoring devices calculate systolic and diastolic blood pressures from the oscillation in cuff pressure caused by a pulsation of an artery. To validate the NIBP devices, we developed a simulator to supply the oscillometric waveforms obtained from human subjects. The simulator provided pressure pulses to device-under-test and device readings were compared to the auscultatory references. Fully automated simulation system including OCR(optical character recognition) were developed and used for NIBP monitoring devices. The validation results using the simulator agreed well with previous clinical validation. More validation studies using the standardized oscillometric waveforms would be required for the replacement of clinical trials to validate a new automated NIBP monitoring device.

A Development of Healthcare Monitoring System Based on Internet of Things Effective

  • KIM, Song-Eun;MUN, Ji-Hui;KIM, Kyoung-Sook;KANG, Min-Soo
    • 한국인공지능학회지
    • /
    • 제8권1호
    • /
    • pp.1-6
    • /
    • 2020
  • The Recently there has been a growing interest in health care due to the COVID-19 situation. In this paper, we intend to develop a healthcare monitoring system to provide users with smart healthcare systems in line with the healthcare 3.0 era. The system consists of a wireless network between various sensors, Android smartphones, and OLEDs using Bluetooth, and through this, a health care monitoring system capable of collecting user's biometric information and managing health by receiving data values of sensors connected to Arduino. In conclusion, the user's BPM value was calculated using the heart rate sensor, and the exercise intensity can be adjusted through this. In addition, a step derivation algorithm is implemented using an acceleration sensor, and calorie consumption can be measured using the step and weight values. As such, the heart rate, step count, calorie consumption data can be transmitted to a smartphone application through a Bluetooth module and output, and can be output to an OLED for users who are not easy to access the smartphone. This healthcare monitoring system can be applied to various groups and technologies.

Development of a diverging collimator for environmental radiation monitoring in the industrial fields

  • Dong-Hee Han;Seung-Jae Lee;Jang-Oh Kim ;Da-Eun Kwon;Hak-Jae Lee ;Cheol-Ha Baek
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4679-4683
    • /
    • 2022
  • Environmental radiation monitoring is required to protect from the effects of radiation in industrial fields such as nuclear power plant (NPP) monitoring, and various gamma camera systems are being developed. The purpose of this study is to optimize parameters of a diverging collimator composed of pure tungsten for compactness and lightness through Monte Carlo simulation. We conducted the performance evaluation based on spatial resolution and signal-to-noise ratio for point source and obtained gamma images and profiles. As a result, optimization was determined at a collimator height of 60.0 mm, a hole size of 1.5 mm, and a septal thickness of 1.0 mm. Also, the full-width-at-half-maximum was 3.5 mm and the signal-to-noise ratio was 53.5. This study proposes a compact 45° diverging collimator structure that can quickly and accurately identify the location of the source for radiation monitoring.

Smart Health Monitoring System (SHMS) An Enabling Technology for patient Care

  • Irfan Ali Kandhro;Asif Ali Wagan;Muhammad Abdul Aleem;Rasheeda Ali Hassan;Ali Abbas
    • International Journal of Computer Science & Network Security
    • /
    • 제24권3호
    • /
    • pp.43-52
    • /
    • 2024
  • Health Monitoring System is a sophisticating technology and another way to the normal/regular management of the health of the patient. This Health Monitoring Mobile Application is a contribution from our side to the public and to the overall health industry in Pakistan. With the help of Health mobile application, the users will be able to store their medical records, prescriptions and retrieve them later. The users can store and keep track of their vital readings (heart rate, blood pressure, fasting glucose, random glucose). The mobile application also shows hospitals that are nearby in case the user wants to avail of any medical help. An important feature of the application is the symptoms-based disease prediction, the user selects the symptoms which he has and then the application will name certain diseases that match those symptoms based on relevant algorithms. The major advances and issues have been discussed, and as well as potential tasks to health monitoring will be identified and evaluated.

삼성서울병원에서 보고된 의약품 부작용의 현황 조사 (The Surveillance of Adverse Drug Reactions (ADR) Reported in Samsung Medical Center)

  • 조정아;이후경;손기호;최경업
    • 한국임상약학회지
    • /
    • 제10권1호
    • /
    • pp.30-37
    • /
    • 2000
  • Adverse drug reactions (ADR) may result in increased hospital admissions, morbidity and mortality, adding extra cost to healthcare expenditures. Thus, it is critical to activate ADR monitoring and reporting program in tertiary hospitals in developing countries such as Korea. This study was performed to identify the types of ADR being reported in a tertiary hospital, Samsung Medical Center, and to find out the ways to improve current ADR monitoring system. Of 464 ADR reports submitted to the pharmacy department during the 6-month survey period, $97.8\%$ of the reports were from out patient and $48.5\%$ were from patients aged between 50 and 60. The medical department with the highest frequency in ADR reporting was Internal Medicines $(35.6\%)$. The most common ADR manifestations were gastrointestinal complaints $(43.4\%)\;and\;75\%$ of the reported cases were mild in their severity. The most common drugs suspected of causing ADR were CNS drugs which accounted for $32.8\%$. In terms of causality assessment, $85.1\%$ of the reports were probable cases by WHO causality assessment criteria. In regards to sources of report, $75.6\%$ of ADR were reported by physicians and $24.4\%$ by nurses. There were no ADR reported by pharmacists. In conclusion, there is an urgent need to improve ADR monitoring system for inpatient and to motivate pharmacist involvement in ADR monitoring and reporting in Korea.

  • PDF