• Title/Summary/Keyword: medical imaging system

Search Result 936, Processing Time 0.033 seconds

A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography (유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.201-208
    • /
    • 2018
  • The purpose of this study was to investigate the optimal flip angle by measuring the SNR and CNR according to the angle of changes of the MRI technique using the Image J program. A total of 30 normal volunteers were assessed by using a 1.5T magnetic resonance imaging system (Philips, Medical System, Achieva). For the MRI angiography, we set the region of interest in four regions and evaluated the SNR and CNR. The statistical significance of SNR and CNR was calculated by one-way ANOVA using quantitative analysis at five different positions. The Bonferroni method was used for post-hoc analyzes. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis. The results of this study, the measurement values of ACA(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), PCA(SNR:$863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR:$1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$) and MCA(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$) were obtained with the high signal intensity at $25^{\circ}$(p<0.05). The values of a1, a2, a3, p1, p2, p3, m1, m2 and m3 were also the same (p<0.05). Post-hoc analysis results, There was a statistically significant difference (p=0.000) between $10^{\circ}$, $15^{\circ}$, $20^{\circ}$ on the $25^{\circ}$ reference for the flip angle, but no significant results were obtained with $30^{\circ}$(p<0.05). In concision, because the signal intensity decreased at $30^{\circ}$, this study revealed that the optimal flip angles were $25^{\circ}$ in cerebrovascular MR angiography.

Comparison of the Legislation Applicable to Compare the use of Diagnostic Radiation Devices (진단용 방사선발생장치 이용에 적용되는 법제의 비교)

  • Ko, Jong-Kyung;Jeon, Yeo-Ryeong;Han, Eun-Ok;Cho, Pyong-Kon;Kim, Yong-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.277-286
    • /
    • 2015
  • Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subject to the Nuclear Safety Act. Even the same radiation devices varies the legislation that is applied depending on the intended use and object. Diversified been p rovisions a re necessary compared to t he analysis o f l egal content in o rder t o prevent confusion of the legislation is a matter to be applied. It is a qualitative study that Nuclear Safety Act, Medical Service Act and Veterinarians Act administrative procedures for the introduction of the applied diagnostic radiation devices, safety inspection, human resources management, area management and the content related to administrative punishment. The Nuclear Safety Act sub-provisions, the introduction of diagnostic radiation generating devices, there are many complex and complete requirements administrative procedures on the concept of a permit. Inspection of safety associated with the use, would be subject to periodic inspection auditing characteristics over the entire field of radiation safety management. It must receive court regular education for the safety administrator and workers. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Quantitative difference of administrative punishment that is imposed when legislation violation has reached up to 10 times, over the entire field, the largest burden of radiation safety management at the time of application of the Nuclear Safety Act sub provisions. And it is applied differently depending on the purpose and the imaging target using the same diagnostic radiation devices. Depending on the use mainly under the current legal system, radiation can be lacking in fairness of the contents of the legislation for safety management, there is a risk of confusion. Alternatives such as centralized and standardization of legislation by diagnostic radiation devices use is expected to be necessary.

A Study on Exposure to radiation of the patient who visited an emergency room at a University Hospital (한 대학병원 응급실에 방문한 환자의 방사선 피폭에 관한 연구)

  • Ahn, Buyung-Ju;Lee, Sang-Bock;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • To find how much radiation was exposed the patients who visit emergency room, a measurement study was made for radiation amount toward 200 patients selected randomly among visitors to an emergency room in a university hospital from March 16 to 31st, 2006. The results are as follows ; 1. Among the subjects 50 person(25.0%) were transferred from other hospitals, 24 persons(8.3) come after traffic accident, 50 persons for other accident and 76 persons for general medical care. 2. The average frequency of X-ray taking was calculated as 6.4 time per person among transferred patients, 14.5 times per person among patients with traffic accident and 2.6 times per person among general medical care. 3. The radiation exposure amount by kind of X-ray showed 28.9mGyfor general X-ray diagnosis, 84.2mGy for CT scanning and 1.02mGy for other special radiation study. 4. Average radiation exposure amount was calculated as 24.6mGy by transferred patients, 55.2mGy by patients with traffic accident, 17.1mGy by patients with other accidents and 17.0mGy by general patients. 5. Through the comparison of radiation exposure amount among to subject with maximum allowance threshold by International Commission on X-ray Radium Protection, transferred patients exceeded 6 times than allowance in whole body except extremities and joints, blood forming organ, reproductive system, vitreous body of eye, bone, thyroid gland, skin and etc, Patient suffered from traffic accidents were exposed 10 times more than allowance. In conclusion, the radiation exposure amount during X-rat diagnosis re too much and exceeded allowance standard by International Commission on X-ray Radium Protection. So further study and preventive measure to decrease radiation exposure by patients who visit emergency room.

  • PDF

Optimization and Stabilization of Automated Synthesis Systems for Reduced 68Ga-PSMA-11 Synthesis Time (68Ga-PSMA-11 합성 시간 단축을 위한 자동합성장치의 최적화 및 안정성 연구)

  • Ji hoon KANG;Sang Min SHIN;Young Si PARK;Hea Ji KIM;Hwa Youn JANG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.2
    • /
    • pp.147-155
    • /
    • 2024
  • Gallium-68-prostate-specific membrane antigen-11 (68Ga-PSMA-11) is a positron emission tomography radiopharmaceutical that labels a Glu-urea-Lys-based ligand with 68Ga, binding specifically to the PSMA. It is used widely for imaging recurrent prostate cancer and metastases. On the other hand, the preparation and quality control testing of 68Ga-PSMA-11 in medical institutions takes over 60 minutes, limiting the daily capacity of 68Ge/68Ga generators. While the generator provides 1,110 MBq (30 mCi) nominally, its activity decreases over time, and the labeling yield declines irregularly. Consequently, additional preparations are needed, increasing radiation exposure for medical technicians, prolonging patient wait times, and necessitating production schedule adjustments. This study aimed to reduce the 68Ga-PSMA-11 preparation time and optimize the automated synthesis system. By shortening the reaction time between 68Ga and the PSMA-11 precursor and adjusting the number of purification steps, a faster and more cost-effective method was tested while maintaining quality. The final synthesis time was reduced from 30 to 20 minutes, meeting the standards for the HEPES content, residual solvent EtOH content, and radiochemical purity. This optimized procedure minimizes radiation exposure for medical technicians, reduces patient wait times, and maintains consistent production schedules, making it suitable for clinical application.

Utility of FDG PET-CT Scans on Nodal Staging of Squamous Cell Carcinoma in the Oral Cavity and Oropharynx (구강 및 구인두 편평상피암종의 림프절 전이에 대한 PET-CT 영상의 유용성)

  • Joo, Young-Hoon;Sun, Dong-Il;Park, Jun-Ook;Yoo, Ie-Ryung;Kim, Min-Sik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.1
    • /
    • pp.14-18
    • /
    • 2010
  • Objectives : We evaluated the use of FDG PET/CT for the identification of cervical nodal metastases of SCC of the oral cavity and oropharynx with histological correlation. Material and Methods : We reviewed 46 medical records, from January 2004 to July 2007, of patients who underwent FDG PET/CT and CT/MRI for SCC of the oral cavity and oropharynx before surgery. We recorded the lymph node metastases according to the neck level affected and the system used for the imaging-based nodal classification. Results : The FDG PET/CT had a sensitivity of 75.6% and a specificity of 96.7% ; it had a higher sensitivity than the CT/MRI for identification of cervical metastases on the side of the neck(26/28 vs. 20/28, p=0.031) and at each of the cervical levels(34/45 vs. 26/45, p=0.008). There was a significant difference in the $SUV_{max}$ between the benign and malignant cervical lymph nodes($3.31{\pm}3.23$ vs. $4.22{\pm}2.57$, p=0.028). The receiver-operating-characteristic (ROC) curve analysis for differentiating the benign from the malignant cervical lymph nodes, showed that the area under the curve(AUC) of the FDG PET/CT was 0.775. The cut-off value for the $SUV_{max}$ was 2.23 based on the ROC curve. There was a significant correlation between the $SUV_{max}$ and the size of the cervical lymph nodes(Spearman r=0.353, p=0.048). Conclusion : FDG PET/CT images were more accurate than the CT/MRI images. In addition, the $SUV_{max}$ cut-off values were important for evaluating cervical the cervical nodes in the patients with SCC of the oral cavity and oropharynx.

Implementation of KV Cone Beam CT for Image Guided Radiation Therapy (영상유도 방사선치료에서의 KV 콘빔CT 이용)

  • Yoo, Young-Seung;Lee, Hwa-Jung;Kim, Dae-Young;Yu, Ri
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.43-49
    • /
    • 2007
  • Purpose: The aim of this study was the clinical implementation of IGRT using KV CBCT for setup correction in radiation therapy. Materials and Methods: We selected 9 patients (3 patient for each region; head, body, pelvis)and acquired 135 CBCT images with CLINAC iX (Varian medical system, USA). During the scan, the required time was measured. We analyzed the result in 3 direction; vertical, longitudinal, lateral. Results: The mean setup errors at the couch position of vertical, lateral, and longitudinal direction were 0.07, 0.12, and 0.1 cm in the head region, 0.3, 0.26, and 0.22 cm in the body region, 0.21, 0.18, and 0.15 cm in the pelvis region respectively. The mean time required for CBCT was $6{\sim}7$ minute. Conclusion: The CBCT on the LINAC provides the capacity for soft tissue imaging in the treatment position and real time monitoring during treatment delivery. With presented workflow, the setup correction within reasonable time for more accurate radiation therapy is possible. And it's image can be very useful for adaptive radiation therapy(ART) in the future with improved image quality.

  • PDF

Magnetic Resonance Angiographic Evaluation as a Screening Test for Patients who are Scheduled for Cardiac Surgery (심장수술 대상자에서 선별 검사로서 두경부 MRA)

  • Suh, Jong-Hui;Choi, Si-Young;Kim, Yong-Hwan
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.718-723
    • /
    • 2008
  • Background: The advances in surgical techniques, anesthesia management, perfusion methodology and postoperative intensive care have markedly decreased the mortality and cardiac morbidity of patients who undergo heart surgery over the past 2 decades. Nevertheless, it is well recognized that cardiac surgery carries a substantial risk for central nervous system complications. This study was conducted to evaluate the prevalence of subclinical cerebrovascular lesions in the head and neck by performing magnetic resonance angiography (MRA), and we investigated the clinical course of patients who had abnormal lesion seen on head and neck MRA. Material and Method: The subjects were 107 patients (71 men and 36 women ranging in age from 21 to 83 years) who were scheduled for cardiac surgery under nonemergency conditions between October 2005 and June 2008. Informed consent was obtained before the MRA. The carotid arteries, intracranial arteries and brain parenchyme were examined for subclinical cerebrovascular lesions by performing MRA. We reviewed the patients' medical records and MR findings to evaluate the prevalence of neurologically high risk patients and their clinical course. Result: The overall prevalence of neurologically high risk patients was 15.7% (17 patients). Among these patients, 11 patients had ischemic heart disease and 6 patients had valvular heart disease. Only 2 patients had a history of cerebrovascular disease. The clinical courses of 14 patients (13.1%) were changed according to their MRI findings. Conclusion: The prevalence of subclinical cerebrovascular disease in patients who were scheduled for cardiac surgery was higher than was expected. MR angiography was of value to identify these patients.

The Fabrication and Evaluation of HgI2 Semiconductor Detector as High Energy X-ray Dosimeter Application (고에너지 X선 선량계 적용을 위한 TiO2 첨가된 요오드화수은 반도체 검출기 제작 및 평가)

  • Choi, Il Hong;Noh, Sung Jin;Park, Jung Eun;Park, Ji Koon;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.383-387
    • /
    • 2014
  • In this paper, for a new detection system development with the better accurate dose evaluation and beam distribution imaging using the small field irradiation of linear accelerator, the compound semiconductor based detection sensors were fabricated and the performance evaluation was investigated. The special particle-in-binder sedimentation was used for a large area film sensor fabrication. The detection properties for high energy x-rays were investigated from a dark current, an output current, a rising time, a falling time, and response delay measurement. The experimental results, the $TiO_2$ mixed $HgI_2$ sensor showed the best electrical characteristics than $PbI_2$, PbO, pure $HgI_2$. Linearity, repeatability, and accuracy tests from LINAC were tested, the $TiO_2$ mixed $HgI_2$ sensor showed the better performance than the commercially available dosimetry devices.

The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom (N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과)

  • Kim, Yon-Min;Shim, Jae-Goo;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.221-225
    • /
    • 2017
  • To evaluate the performance of ultrasound imaging system, we investigated the change of spatial resolution according to changing sonic velocity change parameter provided by ultrasound equipment. Ultrasound phantom images were obtained using a 3.0 ~ 5.0 MHz convex transducer in an ultrasound diagnostic device used at a medical institution located at Iksan. N-365 multi-purpose ultrasound phantom was used to measure longitudinal distance measurement accuracy and longitudinal and transverse resolution. In the same manner, the sonic velocity of the ultrasound equipment was changed from 1580 m/sec to 1400 m/sec in six steps, and the full width at half maximum(FWHM) was measured using the image J program to determine whether the measured values were different. As a result, lateral resolution was measured from 1.91 mm to 5.3 mm according to the speed change, and the smallest FWHM was 1.91 mm at 1420 m/sec. The axial resolution was measured from 1.03 mm to 1.14 mm according to the speed change, and the smallest FWHM was 1.03 mm at 1400 m/sec. The slower the sound velocity of the ultrasound equipment, the shorter the length of longitudinal measurement.

Comparison of Image Quality in Magnetic Resonance Imaging of the Abdominal Organ at 1.5T and 3.0T before the Gadolinium Injection (조영제 주입 전 1.5T 와 3.0T를 이용한 복부장기 자기공명영상에서 영상의 질 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.619-625
    • /
    • 2017
  • The sudy was intended to evaluate the optimal equipment selection by quantitatively assessing the SNR(signal to noise ratio) and CNR(contrast to noise ratio) on the abdominal organ. This study performed on 1.5 T and 3.0 T MRI units focusing on HASTE, HASTE(f/s) and FFE(in of phase), FFE(out of phase) without using the contrast medium(Gadolinium). The data analysis was performed by randomly selecting on 1.5 T and 3.0 T abdominal MRI images. As a results, SNR and CNR values of 3.0 T is higher than 1.5 T at liver, kidney and spleen(p<0.05). Stomach, abdominal fat and pancreas was obtained a higher value at 1.5 T(p<0.05). On conclusion, the organs of outer part in the body showed generally a high value at 3.0 T, and the organs of inner part in the body including the gas showed a high value at 3.0 T because of a large difference on magnetic susceptibility.