• 제목/요약/키워드: medical imaging system

검색결과 936건 처리시간 0.033초

핵의학 영상기기의 감마선 검출기 (Gamma-ray Detectors for Nuclear Medical Imaging Instruments)

  • 조규성
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.88-97
    • /
    • 2008
  • In this review paper, basic configurations of gamma detectors in SPECT and PET systems were reviewed together with key performance parameters of the imaging system, such as the detection efficiency, the spatial resolution, the contrast resolution, and the data acquisition time for quick understanding of the system-component relationship and future design of advanced systems. Also key elements of SPECT and PET detectors, such as collimators, gamma detectors were discussed in conjunction with their current and future trend. Especially development trend of new scintillation crystals, innovative silicon-based photo-sensors and futuristic room-temperature semiconductor detectors were reviewed for researchers who are interested in the development of future nuclear medical imaging instruments.

Cerebellar maturation ratio of forebrain and brainstem at magnetic resonance imaging in the micropig

  • Yi, Kang-Jae;Kim, Jun-Young;Lee, Namsoon;Choi, Mihyun;Yoon, Jung-Hee;Choi, Min-Cheol
    • 대한수의학회지
    • /
    • 제52권2호
    • /
    • pp.83-87
    • /
    • 2012
  • The study of pigs as a human disease model has been conducted in neuroscience. But the morphological development of pig brain by using MRI is rare. The purpose of this study is to determine whether cerebellum maintains consistent proportion to other brain regions in aging. Clinically healthy sixteen micropigs, 1, 2, 4, and 8 months were studied. The micropigs were anesthetized with isoflorane. MRI was acquired using a 0.3T system. To figure out development of ratio that allowed identification of normal cerebellum size, we measured the area of the cerebellum, brainstem, and forebrain from the mid-sagittal brain images on T1W. Mid-sagittal cross-sectional area (CSA) of total brain, forebrain, brainstem, and cerebellum were expressed as absolute values and also as percentages which were compared between the four age groups of micropigs for the purpose to define the effect of age on brain morphometry. It was found that there was not a significant difference in the percentage of the brain occupied by an individual region between groups although the absolute CSA differed significantly among age groups. There was no effect of age on the ratio between the cerebellum and total brain in 4 age groups. The normal size of cerebellum changes during brain development maintained a consistent ratio to other brain regions in normal micropigs. The ratio of CSA quantified on the mid-sagittal MR images offers a suitable method to detect presence of cerebellar anomalies in micropigs.

Diagnostic Usefulness of High Resolution Cross Sectional MRI in Symptomatic Middle Cerabral Arterial Dissection

  • Lee, Hai-Ong;Kwak, Hyo-Sung;Chung, Gyung-Ho;Hwang, Seung-Bae
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권6호
    • /
    • pp.370-372
    • /
    • 2011
  • Dissection of the middle cerebral artery (MCA) is less frequent compared with dissection of the vertebrobasilar system or carotid artery. Recently, high-resolution cross sectional MR imaging (HRMRI) has emerged as a potential technique for atherosclerotic plaque imaging in MCA, We introduce the findings of HRMRI in a 56-year-old woman with traumatic MCA dissection, HRMRI showed an intimal flap and tapered pseudolumen with intra-luminal hemorrhage, We performed stent deployment about MCA dissection after failed medical treatment Three months later, there was no in-stent restenosis and no further neurological deficit were noted.

Applications of Optical Imaging System in Dentistry

  • Eom, Joo Beom;Park, Anjin
    • Medical Lasers
    • /
    • 제9권1호
    • /
    • pp.25-33
    • /
    • 2020
  • Optical-based imaging technology has high resolution and can assess images in real time. Numerous studies have been conducted for its application in the dental field. The current research introduces an oral camera that includes fluorescent imaging, a second study examining a 3D intraoral scanner applying a confocal method and a polarization structure that identifies the 3D image of a tooth, and finally, an optical coherence tomography technique. Using this technique, we introduce a new concept 3D oral scanner that simultaneously implements 3D structural imaging as well as images that diagnose the inside of teeth. With the development of light source technology and detector technology, various optical-based imaging technologies are expected to be applied in dentistry.

로봇 수술을 위한 3차원 구조계산의 필요성 조사 (Research of 3D Information processing for Robot Surgery)

  • 정재은;최석윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.43-50
    • /
    • 2009
  • Geometry calculation Using Abdominal internal organ image from traditional laparoscopy or robotic surgery system we can make depth informations through measured 3D structure informations is very helpful to doctors, depth information is mare useful then others that use traditional laparoscopy or robotic surgery system to many doctors. however, traditional method are incomplete. less experienced doctors make much mare prohability of mistake. Hence, 3D information of organ is very helpful to the less experienced doctors. it will be greate role of reducing medical accidents and surgical time. We can get 3D informations using geometrical calculation method in robotic surgical system. also suggested method is needed in traditional surgical method without the need to create a new system, finally, We can get 3D information from traditional system without any new system, it take advantage in cost and create high efficiency. mare information will provided to many doctors.

  • PDF

동물병원 방사선 안전관리체계에 대한 연구 (Study of Radiation Safety Management of Veterinary Hospital in Korea)

  • 채수영;최호정;이영원
    • 한국임상수의학회지
    • /
    • 제37권1호
    • /
    • pp.15-22
    • /
    • 2020
  • This study investigated the effectiveness of radiation safety rules in animal hospital and the awareness and behavior of veterinary radiation workers. With the questionnaires, the data was collected from randomly selected veterinarians in animal hospitals and animal medical imaging centers. Collected data were about radiation device, shielding device, regulations, safety management, education, knowledge, behavior and awareness. Frequency, correlation and multiple regression analysis were performed. The medical devices related with radiation in animal hospital were X-ray (59%), CT (15%), fluoroscopy (12%), mobile X-ray (12%) and others (2%). The number of people using radiation shielding device is high. The answers were low on knowing radiation related regulation and receiving radiation protection education. The group with higher knowledge and awareness shows positive correlation with safety behavior. The increase of use of the radiation related medical devices in veterinary hospital causes the increase of radiation exposure risk. This study suggests that radiation safety management system and policies need to be developed to protect radiation workers and give them correct information and consciousness.

Research status for long term half-life PET radioisotopes in KIRAMS

  • Kim, Jung Young;Park, Hyun;Chun, Kwon Soo;An, Gwang Il
    • 대한방사성의약품학회지
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2015
  • It is essential use of long term half life radioisotopes for positron emission tomography (PET) imaging study of biopharmaceuticals because most of biopharmaceuticals have long biological half-life. Some representative isotopes are $^{124}I$, $^{64}Cu$, $^{89}Zr$ and so on. These PET radioisotopes and their radiopharmaceuticals have recently received growing interest because of long half life and good imaging properties. Furthermore, $^{64}Cu$ and $^{89}Zr$ can be used in a number of radiopharmaceuticals due to its ease of conjugation to peptides and antibodies using the proper chelator. In recent years, since $^{124}I$ was first developed in 2005, we have been studied to develop an efficient method and procedure for producing these radioisotopes, and we have made considerable progress in production of long term half life radioisotopes. This review introduces the general production system, purification procedure, and several advances on targeting method for $^{124}I$ and $^{64}Cu$ in KIRAMS.

원격응급시스템의 방사선 영상장치 구현 (An Implementation of Radiologic Imaging Device of Remote Emergency Medical System)

  • 조동헌
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.60-65
    • /
    • 2007
  • 구급차에 장착하거나 사고 현장에서 사용할 수 있는 방사선 영상장치를 구현하였다. DC 12[V] 입력 전원에서 X-ray 튜브를 통해서 X-ray를 발생하는 장치를 구성한 후 오실로스코프를 활용하여 특성 실험을 하였다. 그리고 발생된 X-ray에 대해 디지털 디텍터를 이용하여 파일 형태로 저장하는 실험을 하였다. X-ray를 발생시킨 후 디지털 디텍터로 검출한 결과, 파일 크기가 1.67[MB]이고, jpg 형태로 이루어진 방사선정보를 저장할 수 있었다. 구현된 방사선 영상장치는 환자가 의사로부터 공간적으로 멀리 떨어져 있어 시간적으로 진단과 치료가 동시에 이루어지기 어려운 상황에 효율적으로 대처할 수 있는 장점이 있다. 따라서 구현된 방사선 영상장치는 긴박한 상황이 발생한 사고 현장이나 이동 중인 구급차 내에서 X-ray 촬영을 함으로써, 환자의 X-선 정보를 응급의료 센터의 의사에게 전달하고 의사의 처방을 받을 수 있는 의료 선진화를 구현하는 데 기여할 수 있을 것으로 기대된다.

적외선 체열촬영시스템을 위한 고속 광주사기의 구현 (Realization of a High Speed Optic Scanner for Infrared Thermal Imaging)

  • 이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권1호
    • /
    • pp.43-48
    • /
    • 1995
  • A high speed optic scanner capable of 16 frames/sec imaging has been developed for the realization of the infrared thermal Imaging system with a single element infrared sensor. The high speed optic scanner is composed of a rotating polygon mirror for horizontal scanning, a flat mirror mounted on a galvanometer for vertical scanning, and a spherical mirror. It has been experimentally found that the optic scanner is capable of 16 framesllsec imaging with the frame matrix size of 256 x 64.

  • PDF