• Title/Summary/Keyword: mechanical waveform

검색결과 163건 처리시간 0.154초

Research of Torque Ripple Reduction of BLDC Motor (BLDC 전동기의 토크리플 저감에 대한 연구)

  • Nam K.Y.;Hong J.P.;Lee C.M.;Chung W.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1455-1458
    • /
    • 2005
  • This paper presents the method of reducing torque ripple of Blushless Direct Current(BLDC) motor. In the BLDC motor, the torque is decided by the back-EMF and current waveform. If the back-EMF is constant, the torque ripple depends on the current ripple during commutation period. The current in commutation period is acquired by circuit analysis and then the torque ripple simply can be reduced by varying input voltage to flow the current continuously. And suggested method is confirmed by dynamic with parameters of 500W BLDC motor.

  • PDF

Biomaterials toward Future Medicine

  • Sakurai, Yasuhisa
    • Journal of Biomedical Engineering Research
    • /
    • 제7권2호
    • /
    • pp.117-118
    • /
    • 1986
  • It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization.

  • PDF

EVALUATION OF AUDITORY EVOKED POTENTIALS IN WHITE NEW ZEALAND RABBITS WITH SIMULATED SUBDURAL HEMATOMA AND INCREASED INTRACRANIAL PRESSURE (경막혈종 및 뇌내압 증가에 따른 청각 유발전위의 분석)

  • Im, Jae-Joong
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.171-174
    • /
    • 1992
  • Development of a noninvasive intensive care system calls for the use of evoked potentials (EPs), as a means of diagnosing traumatic head-injured patients. The experiment entails surgically plating two subarachnoid bolts and a subdural balloon through the skull to simulate a subdural hematoma. Using various levels of intracranial pressure (ICP) and/or different sizes of balloons, auditory evoked potentials (AEPs) were recorded from a rabbit. Six positive peat latencies ($P_1-P_6$) and five negative peak latencies ($N_1-N_5$) were extracted from an averaged AEP waveform. Multiple regression analyses were performed for determining a relationship between the ICP and AEP peak latencies. The results indicate that a major correlation of changes on AEP peak latencies is due to mechanical forcer of a mass (inflated balloon simulating a hematoma) in the distortion of the brain matter rather than increased ICP.

  • PDF

A Commutations Strategy for Torque Ripple Reduction of Sensorless Drive for Brushless DC Motors (BLDC 전동기용 센서리스 드라이브의 토크 리플 저감을 위한 전환 방법에 관한 연구)

  • 여형기;김태형;이광운;박정배;유지윤
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.199-205
    • /
    • 1998
  • Brushless DC motors have trapezoidal back-EMF waveform. Theoretically it should be fed with rectangular phase current in order to produce torque ripple free. Because it is drived by a voltage source inverter, perfect rectangular phase current can not available and therefore produce torque ripple. In this paper, the torque ripple due to commutation is analyzed and the practical method that can reduce the torque ripple is proposed. Experimental and simulation results show the effectiveness of the proposed method.

  • PDF

A Study on Real Time Automatic Diagnosis of Arrhythmias (실시간 부정맥 자동진단에 관한 연구)

  • Shin, Ho-Yong;Shin, Kun-Soo;Lee, Byung-Chae;Lee, Myoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1276-1279
    • /
    • 1987
  • Cardiac arrhythmias are associated with electrical Instability and, hence, with abnormal mechanical activity of the heart in many cases, arrhythmias can be treated with drugs or electric shock to control and/or stop them. Hence fast arrhythmia detection is very important. In this paper RR interval, QRS width, and morphology are used for diagnosis and QRS complex is detected by hardware system. hence diagnosing time is shorten. Moreover doctors or nurses who have little knowledge of computer manipulation can get the Information of Patient's ECG by showing characteristics of abnormal waveform and by mapping graphs of RR interval .vs. QRS width and RR interval .vs. morphology on screen.

  • PDF

The Feature Extraction of Welding Flaw for Shape Recognition (용접결함의 형상인식을 위한 특징추출)

  • Kim, Jae-Yeol;You, Sin;Kim, Chang-Hyun;Song, Kyung-Seok;Yang, Dong-Jo;Lee, Chang-Sun
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.304-309
    • /
    • 2003
  • In this study, natural flaws in welding parts are classified using the signal pattern classification method. The storage digital oscilloscope including FFT function and enveloped waveform generator is used and the signal pattern recognition procedure is made up the digital signal processing, feature extraction, feature selection and classifier design. It is composed with and discussed using the distance classifier that is based on euclidean distance the empirical Bayesian classifier. Feature extraction is performed using the class-mean scatter criteria. The signal pattern classification method is applied to the signal pattern recognition of natural flaws.

  • PDF

The Prediction of Fatigue Damage for Pressure Vessel Materials using SH Ultrasonic Wave (압력용기 고온 고압부의 피로손상 예측을 위한 SH 초음파 평가 기법 개발)

  • Kang, Yong-Ho;Chung, Yong-Keun;Park, Jong-Jin;Park, Ik-Min
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.678-683
    • /
    • 2003
  • Ultrasonic method using SH(shear horizontal) wave has been developed to determine the surface damage in fatigued material. Fatigue damages based on propagation energy were analyzed by multiregression analysis and phase measurement in interrupted fatigue test specimen including CrMoV and 12Cr alloy steel. From the test results, as the fatigue damage increased the propagation time of the launched waves increased and amplitude of wavelet decreased. Also, analysis for the waveform modulation showed a reliable estimation, with confidence limit of 97% for 12Cr steel and 95% for CrMoV steel, respectively. Therefore, It is thought that SH ultrasonic wave technique can be applied to determine fatigue damage of in-service component nondestructively.

  • PDF

The Prediction of Fatigue Damage for Pressure Vessel Materials using Shear Horizontal Ultrasonic Wave (SH(shear horizontal) 초음파를 이용한 압력용기용 재료의 피로손상 예측)

  • Kang, Yong-Ho;Chung, Yong-Keun;Song, Jung-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제26권6호
    • /
    • pp.90-96
    • /
    • 2009
  • Ultrasonic method using SH(shear horizontal) wave has been developed to determine the surface damage in fatigued material. Fatigue damages based on propagation energy were analyzed by multi-regression analysis in interrupted fatigue test specimen including CrMoV and 12Cr alloy steel. From the test results, as the fatigue damage increased the propagation time of the launched waves increased and amplitude of wavelet decreased. Also, analysis for the waveform modulation showed a reliable estimation, with confidence limit of 97% for 12Cr steel and 95% for CrMoV steel, respectively. Therefore, It is thought that SH ultrasonic wave technique can be applied to determine fatigue damage of in-service component nondestructively.

Reconstruction of Dispersive Lamb Waves in Time Plates Using a Time Reversal Method

  • Jeong, Hyun-Jo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제28권1호
    • /
    • pp.59-63
    • /
    • 2008
  • Time reversal (TR) of nondispersive body waves has been used in many applications including ultrasonic NDE. However, the study of the TR method for Lamb waves on thin structures is not well established. In this paper, the full reconstruction of the input signal is investigated for dispersive Lamb waves by introducing a time reversal operator based on the Mindlin plate theory. A broadband and a narrowband input waveform are employed to reconstruct the $A_0$ mode of Lamb wave propagations. Due to the frequency dependence of the TR process of Lamb waves, different frequency components of the broadband excitation are scaled differently during the time reversal process and the original input signal cannot be fully restored. This is the primary reason for using a narrowband excitation to enhance the flaw detectability.

Experimental research on blood sucking phenomena of a female mosquito (암모기 흡혈과정에 대한 실험적 연구)

  • Kim, Bo-Heum;Lee, Jung-Yeop;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1475-1478
    • /
    • 2008
  • We have investigated the blood sucking phenomena of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism and eventually to develop a bio-mimic technology that can be used to resolve the problem encountered in the transport of infinitesimal biological fluids in various bio-chips and microchips. At first, the consecutive velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) system employed with a high-speed camera. The velocity signals of the blood-sucking flow in the proboscis represent a periodic pulsatile flow pattern and spectral analysis on the velocity waveform shows a clear peak at 6.1 Hz.

  • PDF