The effect of neutron irradiation on hydride reorientation and mechanical property degradation of zirconium alloy cladding

  • Jang, Ki-Nam;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1472-1482
    • /
    • 2017
  • Zirconium alloy cladding tube specimens were irradiated at $380^{\circ}C$ up to a fast neutron fluence of $7.5{\times}10^{24}n/m^2$ in a research reactor to investigate the effect of neutron irradiation on hydride reorientation and mechanical property degradation. Cool-down tests from $400^{\circ}C$ to $200^{\circ}C$ under 150 MPa tensile hoop stress were performed. These tests indicate that the irradiated specimens generated a smaller radial hydride fraction than did the unirradiated specimens and that higher hydrogen content generated a smaller radial hydride fraction. The irradiated specimens of 500 ppm-H showed smaller ultimate tensile strength and plastic strain than those characteristics of the 250 ppm-H specimens. This mechanical property degradation caused by neutron irradiation can be explained by tensile hoop stress-induced microcrack formation on the hydrides in the irradiation-damaged matrix and subsequent microcrack propagation along the hydrides and/or through the matrix.

Meso-Scale Approach for Prediction of Mechanical Property and Degradation of Concrete

  • Ueda, Tamon
    • Corrosion Science and Technology
    • /
    • 제3권3호
    • /
    • pp.87-97
    • /
    • 2004
  • This paper presents a new approach with meso scale structure models to express mechanical property, such as stress - strain relationships, of concrete. This approach is successful to represent both uniaxial tension and uniaxial compression stress - strain relationship, which is in macro scale. The meso scale approach is also applied to predict degraded mechanical properties of frost-damaged concrete. The degradation of mechanical properties with frost-damaged concrete was carefully observed. Strength and stiffness in both tension and compression decrease with freezing and thawing cycles (FTC), while stress-free crack opening in tension softening increases. First attempt shows that the numerical simulation can express the experimentally observed degradation by introducing changes in the meso scale structure in concrete, which are assumed based on observed damages in the concrete subjected to FTC. At the end applicability of the meso scale approach to prediction of the degradation by combined effects of salt attack and FTC is discussed. It is shown that clarification of effects of frost damage in concrete on corrosion progress and on crack development in the damaged cover concrete due to corrosion is one of the issues for which the meso scale approach is useful.

고온 재질 열화도를 반영한 CrMoV 터빈로터의 재료 위험도 및 잔여수명 평가 (Assessment of Material Risk and Residual Life of CrMoV Turbine Rotor Considering High Temperature Material Degradation)

  • 마영화;이진상;윤기봉
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.33-41
    • /
    • 2006
  • Material degradation should be considered to assess integrity and residual life of high temperature equipments. However, the property data reflecting degradation are not sufficient for practical use. In this study measuring properties for 1Cr-1Mo-0.25V forging steel generally used for turbine rotor was carried out. Degradation was simulated by isothermal ageing. heat treatment and variation of microstructure was observed. Mechanical properties such as tensile strength, impact energy, hardness and fracture toughness were measured. Assuming a semi-elliptical surface crack at the bore hole in a turbine rotor, material risk was estimated by using the aged material property data obtained in this study. Safety margin was decreased and life of the rotor was exhausted. This procedure can be used in assessing the residual life of a turbine rotor due to material degradation.

산불 피해목의 재질변화에 관한 연구(II) - 산불 피해 소나무의 경시적 재질변화 - (Variation of Material Properties of Fire-killed Timber - Impact of Time on Degradation of Mechanical Properties -)

  • 박정환;박병수;김광모;이도식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권1호
    • /
    • pp.30-35
    • /
    • 2008
  • 동해안 지역에서 산불로 고사된 소나무의 5년에 걸친 경시적 재질 변화를 역학성능을 중심으로 조사하였다. 고사에 따른 재질열화로 가장 크게 영향 받는 역학성능은 충격 휨 흡수에너지였다. 따라서 고사 초기의 재질변화를 예측하는 지표로 활용이 가능할 것으로 밝혀졌다. 고사 경과에 따라 변재의 재질열화가 심재에 비해 두드러지게 진행되었다. 열화의 정도는 충격 휨 흡수에너지가 가장 컸으며 압축강도가 가장 작았다. 고사 이후의 외관 변화와 역학성능의 열화진행 정도로 볼 때 산불피해 소나무의 유효한 활용을 위한 적정 벌채 시기는 산불발생 1년 이내가 바람직한 것으로 밝혀졌다.

등온열처리법에 의해 모의 열화된 1Cr-1Mo-0.25V 터빈케이싱 강의 재질열화 평가 (Evaluation of Material Degradation of 1Cr-1Mo-0.25V Turbine Casing Steel Aged Artificially by Isothermal Heat Treatment)

  • 마영화;김도형;윤기봉
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.22-26
    • /
    • 2010
  • Material degradation should be considered to assess integrity and residual life of high temperature equipments. However, the property data reflecting degradation are not sufficient for practical use. In this study, mechanical properties of 1Cr-1Mo-0.25V casting steel generally used for turbine casing were measured and variation of microstructure was observed. Degradation was simulated by isothermal heat treatment.

질산칼슘 처리농도에 따른 수축견사의 이화학적 특성 (Physical and Chemical Properties of Silk Fiber Treated with Calcium Nitrate)

  • 이광길;이용우
    • 한국잠사곤충학회지
    • /
    • 제40권1호
    • /
    • pp.70-77
    • /
    • 1998
  • This study was carried out in order to find out the relationship between physical and chemical properties of silk fiber treated by concentrated calcium nitrate solution. The tensile, thermal and dynamic mechanical properties are also examined on Ca(NO3)2 treated silk fibers. The tensile properties of silk fibers treated by calcium nitrate changed with a concentration. The thermal behavior were also affected by the concentration of calcium nitrate. The degradation temperature (endotherms) and glass transition temperature shifted to lower temperature as the treated concentration increased. It is thought that the physical properties are strongly related to the structure and morphology of Ca(NO3)2 treated silk fibers. As a result, these give property changes with a concentration dependence.

  • PDF

Bending Strain Dependence of the Transport Property in Jointed BSCCO Tapes

  • Dedicatoria, Marlon J.;Shin, Hyung-Seop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권2호
    • /
    • pp.5-8
    • /
    • 2010
  • In this study, the effect of bending strain on the transport property and critical current of lap and butt-jointed (non-laminated) BSCCO tapes has been investigated. The samples were joined using a mechanically controlled jointing procedure. To achieve a uniform thickness at the joint a single point loading contact has been devised. GFRP mandrels with different bending radii which support the sample during bending have been used. $I_c$ have been measured at 77 K and self field. In the case of easy bending test for jointed BSCCO tapes, sudden degradation of $I_c$ is caused by the local strain concentration due to non uniform deformation at the edge parts of the joint. In the case of hard bending test of jointed BSCCO tapes transverse macroscopic crack at specific subsection caused a large $I_c$ degradation. The transport property of jointed BSCCO tapes in each bending mode was discussed with the damage morphology occurred.

Hastelloy X의 고온열화에 따른 미세구조 및 고온압축특성 (Microstructural Analysis and High Temperature Compression Behavior of High Temperature Degradation on Hastelloy X)

  • 김길수;조태선;서영익;류우석;김영도
    • 한국재료학회지
    • /
    • 제16권5호
    • /
    • pp.318-322
    • /
    • 2006
  • Short-term high temperature degradation test was conducted on Hastelloy X, a candidate tube material for high temperature gas-cooled reactors (HTGR), to evaluate the variation of microstructure and mechanical property in air at $1050^{\circ}C$ during 2000 h. The dominant oxide layer was Cr-oxide and a very shallow Cr-depleted region was observed below the oxide layer. At the beginning of degradation, the island shape $M_6C$ precipitate (M=Mo-rich, Fe, Ni, Cr) was observed in matrix region. After 2000 h degradation, precipitate shape was changed to the chain shape and increased amount of precipitate. These results influenced mechanical property of the specimen which exposed in high temperature. Yield strength was decreased from 115MPa to 89 MPa after 24 h and 2000 h exposure, respectively.

단파장 자외선(254 nm)에 노출된 고밀도 폴리에틸렌 수지의 카르보닐 지수(CI)와 기계적 물성 변화의 관계에 관한 연구 (A Study on the Relationship of Change of Mechanical Properties and Carbonyl Index Induced through Short-wavelength Ultraviolet Radiation (254 nm) for High Density Polyethylene)

  • 김창환;신진용
    • 공업화학
    • /
    • 제24권2호
    • /
    • pp.138-143
    • /
    • 2013
  • 화학적 열화를 빠르게 유도할 수 있는 단파장의 자외선(254 nm)을 고밀도 폴리에틸렌의 표면에 조사하여, 생성된 carbonyl band의 변화로부터 기계적 물성 변화를 예측할 수 있는 지에 대한 가능성을 연구하였다. 오랜 시간이 요구되는 자연 태양광에 의한 옥외폭로시험이나, 제논-아크 광원에 의한 광 열화 대신에 광양자 에너지가 높은 UVC 램프를 사용함으로써, 유도되는 광열화의 화학적 특성이 동일한 기계적 물성 변화를 유발하는지를 확인하는 것에 본 연구의 의미가 있다. 인장시험과 크리프-파괴시험으로 진행된 고밀도 폴리에틸렌의 기계적 강도는 CI 변화에 유사한 양상을 보였으며, 특히 항복강도와 신장률은 자외선 노출시간과 밀접한 관계가 있음을 보여주었다. 따라서 빠른 표면 열화를 유발하는 UVC 램프를 활용한 카르보닐 지수와 기계적 물성 변화의 관계를 통하여 장시간이 요구되는 옥외에서의 기계적 물성변화를 보다 빠르게 파악할 수 있는 방법을 제시하였다.

Cr-Mo 강의 열화도 평가를 위한 Advanced Indentation System의 응용 (Application of Advanced Indentation System for Evaluati Tensile Property Degradation of Cr-Mo Steel)

  • 장재일;최열;이윤희;권동일;김정태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.231-236
    • /
    • 2001
  • A newly developed Advanced Indentation System (AIS), which is a portable and nondestructive system for evaluating tensile properties, was used to measure mechanical behavior of materials used under high temperature and pressure conditions. This test measures indentation load-depth curve during indentation and analyzes the mechanical properties related to deformation and fracture. Aging effects of Cr-Mo and Cr-Mo-V steel at high temperature were simulated. Tensile properties including yield strength and tensile strength at various temperature are obtained from the test. For all test materials and conditions, the AIS-derived results were in good agreement with those from conventional standard test method. Examples of the test results ate given and potential applications of the AIS to assess the integrity of aging structures are briefly discussed.

  • PDF