• 제목/요약/키워드: mechanical power

Search Result 7,593, Processing Time 0.038 seconds

Solvolysis of Substituted Benzyl Bromides (치환 브롬화벤질류의 가용매분해반응)

  • soo-Dong Yoh;Hye-Ryung Kim;Sung-Hong Kim;Byung-Soo Park
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.581-587
    • /
    • 1988
  • The solvolysis of substituted benzyl bromides was studied in binary solvent mixtures of acetone-water and ethanol-water at $25^{\circ}C$ and $45^{\circ}C$. The rate constants increase with electron-donating substituents in benzene ring and increasing of water contents in both of solvent mixtures. The sensitivity parameter (m) of the solvolysis of substituted benzyl bromides to solvent ionizing power (Y) was decreased in going from the electron-donating group to electron-withdrawing one, whereas their nucleophilic sensitivity increased continuously in going to above same substituents. It was shown that electron-donating (electron-withdrawing) groups make the transition state looser (tighter). The above results were consisted with the account for the potential energy surface model and the quantum mechanical approach.

  • PDF

Microstructure and Mechanical Properties of the Sintered Kaolin Block with Fly Ashes (Fly Ash를 이용한 고령토벽돌의 소결 특성)

  • Lee, Jin-Uk;Lee, Sung-Min;Kim, Hyung-Tae;Choi, Eui-Seok;Lee, Yong-Seok
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.12
    • /
    • pp.1164-1170
    • /
    • 2002
  • The effect of fly ash addition to the kaolin block has been investigated. The addition affected the firing temperature and physical properties such as water absorption and compressive strength. The starting materials were from korea natural resources and the fly ash were from the power plant using coal as fuel, containing free carbon of 8∼9 wt%. The starting natural materials were mixed with 5 different proportions of fly ash, pressed and then sintered at 1050, 1100, 1150 and 1200${\circ}C$. With sintering temperature, water absorption decreased and compressive strength increased. When specimens were sintered at the temperature lower than 1100${\circ}C$, water absorption increased and strength decreased with fly ash content. In contrast, when sintering was done at the temperature higher than 1150${\circ}C$, water absorption increased with fly ash content similarly but strength was improved.

Analysis of a damaged industrial hall subjected to the effects of fire

  • Kmet, Stanislav;Tomko, Michal;Demjan, Ivo;Pesek, Ladislav;Priganc, Sergej
    • Structural Engineering and Mechanics
    • /
    • v.58 no.5
    • /
    • pp.757-781
    • /
    • 2016
  • The results of diagnostics and analysis of an industrial hall located on the premises of a thermal power plant severely damaged by fire are presented in the paper. The comprehensive failure-related diagnostics, non-destructive and destructive tests of steel and concrete materials, geodetic surveying of selected structural members, numerical modelling, static analysis and reliability assessment were focused on two basic goals: The determination of the current technical condition of the load bearing structure and the assessment of its post fire resistance as well as assessing the degree of damage and subsequent design of reconstruction measures and arrangements which would enable the safe and reliable use of the building. The current mechanical properties of the steel material obtained from the tests and measured geometric characteristics of the structural members with imperfections were employed in finite element models to study the post-fire behaviour of the structure. In order to compare the behaviour of the numerically modelled steel roof truss, subjected to the effects of fire, with the real post-fire response of the damaged structure theoretically obtained resistance, critical temperature and the time at which the structure no longer meets the required reliability criteria under its given loading are compared with real values. A very good agreement between the simulated results and real characteristics of the structure after the fire was observed.

A Performance Measurement and Evaluation of a 400RT Vertical type Geothermal System installed in a Complex Building Before Occupancy (복합용도 건물에 적용된 400RT급 수직형 지열시스템의 입주전 성능평가)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, Joong-Hun;Shin, Seung-Ho;Jung, Myoung-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.7-14
    • /
    • 2008
  • 400RT geothermal system which is the biggest capacity among on-operations at present in Korea is measured and evaluated on 23rd${\sim}$26th Jan. 2008 during those days building is not allowed owners and/or tenants to move in. The geothermal system is consist with vertical-typed 112 geothermal heat exchangers which are installed circle-like 1 row with 4m interval, and has 16 units of 25USRT geothermal-source heat pump(GSHP)s. And each 5 units of circulation pump are running for geothermal heat exchangers and hot water supplies. The followings are the results. The temperatures at G.L. -70m of 2 boreholes are varied quite similarly. The average temperature difference between inlet and outlet of geothermal pipes is $4.1^{\circ}C$, and that of hot water supply is $3.2^{\circ}C$, of Zone 3's each 4 GSHPs when being operated. Despite temperature fluctuations by heating loads, the average temperature difference between main pipes of inlet and outlet of geothermal heat exchangers is measured as $4.1^{\circ}C$. This study propose "Geothermal System COP" which includes not only consumed electric power by compressor but also circulation pumps and auxiliary utilities. By comparing the geothermal system COP with GSHP's performance specification, it is clear that the performances of GHSPs of this site are satisfied with the specification.

Reduction of the Flow Accelerated Corrosion within Low Pressure Evaporator Connection Pipe by Interception of Hydrazine for Water Treatment (탈산소제 차단 수처리에 의한 배열회수보일러 저압증기발생기 연결배관내의 유동가속부식 저감)

  • Son, Byung-Gwan;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.9 no.4
    • /
    • pp.26-30
    • /
    • 2013
  • Based on case that HRSG low pressure steam generator tube was damaged by FAC in 500 MW A CCPP. This case analyzed the effect of application about the block of hydrazine water treatment which is applied for increasing dissolved oxygen. And also try to deduce the major factor of FAC Which is caused by lacking of dissolved oxygen of boiler feed system. After 1 year of water treatment, the figure of dissolved oxygen in the boiler feed water has increased from 0.15 ppb to 3~5 ppb and the figure of oxidation reduction potential has increased from -245 mV to 170 mV. And Iron content, the corrosion products by FAC has decreased from 18.5 ppb to 5~7 ppb. According to the result of experiment, we could able to confirm that the interception of hydrazine of water treatment is effective to reduce FAC.

  • PDF

Tensile and impact toughness properties of various regions of dissimilar joints of nuclear grade steels

  • Karthick, K.;Malarvizhi, S.;Balasubramanian, V.;Krishnan, S.A.;Sasikala, G.;Albert, Shaju K.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.116-125
    • /
    • 2018
  • Modified 9Cr-1Mo ferritic steel is a preferred material for steam generators in nuclear power plants for their creep strength and good corrosion resistance. Austenitic stainless steels, such as type 316LN, are used in the high temperature segments such as reactor pressure vessels and primary piping systems. So, the dissimilar joints between these materials are inevitable. In this investigation, dissimilar joints were fabricated by the Shielded Metal Arc Welding (SMAW) process with Inconel 82/182 filler metals. The notch tensile properties and Charpy V-notch impact toughness properties of various regions of dissimilar metal weld joints (DMWJs) were evaluated as per the standards. The microhardness distribution across the DMWJs was recorded. Microstructural features of different regions were characterized by optical and scanning electron microscopy. Inhomogeneous notch tensile properties were observed across the DMWJs. Impact toughness values of various regions of the DMWJs were slightly higher than the prescribed value. Formation of a carbon-enriched hard zone at the interface between the ferritic steel and the buttering material enhanced the notch tensile properties of the heat-affected-zone (HAZ) of P91. The complex microstructure developed at the interfaces of the DMWJs was the reason for inhomogeneous mechanical properties.

Prediction of Failure for a Motor Stator by Monitoring Magnetic Flux Spectrum in High Frequency Region (고주파 영역 자속 스펙트럼 감시에 의한 전동기 고정자 고장예측)

  • Kim, Dae-Young;Yeo, Yeong-Koo;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.8 no.3
    • /
    • pp.49-54
    • /
    • 2012
  • In this study, the way how we can find the defects of motor windings in advance will be discussed. The magnetic flux spectrum in the high frequency region of the large motor was analyzed based on the actual fault practices related with motor windings. In case of defective motor relative amplitude ratio of the stator slot frequency to its sideband was very high compared to that of healthy motor. And the defective signal related with motor windings was indicated in advance in the magnetic flux spectrum prior to over 1 month before failure. Considering this aspect it can be estimated that magnetic flux spectrum in the high frequency region has the excellent predictive diagnostic capability.

  • PDF

Performance of a Latent Heat Storage System Using Two-Phase Closed Thermosyphon(II) - The Case of Constant Temperature Heating Fluid (열싸이폰을 이용한 잠열축열시스템의 성능실험(II) - 일정한 온도의 가열유체를 사용한 경우 -)

  • Kim, Tae-Il;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.37-46
    • /
    • 1992
  • An experimental study was carried out to investigate the performance of a latent heat storage system using paraffin wax as the phase change material. A thermosyphon was employed to transfer heat from the hot ethylene glycol flowing across the evaporator section of the thermosyphon into the wax. In order to increase the effective thermal conductivity of wax, layers of copper wire mesh were immersed in the wax. Experiments were run for volume ratios of 2%, 3%, and 4%, varying mass flow rate of ethylene glycol in each case. Some of the important results are as follows : (1) The wire mesh enhanced the conductive hea transfer and thus, helped even out the temperature distribution in the wax : (2) The increase of the number of layers of wire mesh increased the conduction. However, it also resulted in increasing the resistance to the convective motion of liquefied wax : and (3) There is an optimal number of layers of wire mesh, maximizing the performance of the storage system, which occurred at a volume ratio of $3{\sim}4%$ in the present study.

  • PDF

Performance of a Latent Heat Storage System Using Two-Phase Closed Thermosyphon(I) - the Case of Constant Heat Input - (열싸이폰을 이용한 잠열축열시스템의 성능실험(I) - 열주입량이 일정한 경우 -)

  • Kim, Tae-Il;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.28-36
    • /
    • 1992
  • The performance of a latent heat storage system using a thermosyphon as the heat transfer device between the heat source and the phase change material was investigated experimentally. In order to increase the effective conductivity of the phase change material, layers of copper wire mesh were immersed in the paraffin wax(Sunoco P-116) in such a way that they also may be considered as fins of the thermosyphon. The important results are as follows : (1) The void space of the wire mesh allowed the convection to occur, thus enhanced the performance of the system : (2) The increase of the number of layer of wire mesh increased the conduction heat transfer. However, it also had adverse effect of subduing convective motion of liquid wax : and (3) Overall heat transfer coefficient and thermosyphon conductance increased with the increase of the number of layer of wire mesh, whereas the heat transfer coefficient between the thermosyphon and the wax decreased.

  • PDF

The Bonding Strength Characteristic of the Filler Metal Powder on the TLP Bonded Region of Superalloy GTD-111DS (일방향 초내열합금 GTD-111DS에서 삽입금속 분말에 따른 천이액상확산접합부의 접합강도 특성)

  • Oh, In-Seok;Kim, Gil-Moo;Moon, Byeong-Shik
    • Journal of Welding and Joining
    • /
    • v.25 no.5
    • /
    • pp.45-50
    • /
    • 2007
  • The Ni-base superalloy GTD111 DS is used in the first stage blade of high power land-based gas turbines. Advanced repair technologies of the blade have been introduced to the gas turbine industry over recent years. The effect of the filler metal powder on Transient Liquid Phase bonding phenomenon and tensile mechanical properties was investigated on the GTD111 DS superalloy. At the filler metal powder N series, the base metal powders fully melted at the initial time and a large amount of the base metal near the bonded interlayer was dissolved by liquid inter metal. Liquid filler metal powder was eliminated by isothermal solidification which was controlled by the diffusion of B into the base metal. The solids in the bonded interlayer grew from the base metal near the bonded interlayer inward the insert metal during the isothermal solidification. The bond strength of N series filler metal powder was over 1000 MPa. and ${\gamma}'$ phase size of N series TLP bonded region was similar with base metal by influence of Ti, Al elements. At the insert metal powder M series, the Si element fluidity of the filler metal was good but microstructure irregularity on bonded region because of excessive Si element. Nuclear of solids formed not only from the base metal near the bonded interlayer but also from the remained filler metal powder in the bonded interlayer. When the isothermal solidification was finished, the content of the elements in the boned interlayer was approximately equal to that of the base metal. But boride and silicide formed in the base metal near the bonded interlayer. And these boride decreased with the increasing of holding time. The bond strength of M series filler metal powder was about 400 MPa.