• Title/Summary/Keyword: mechanical joint

Search Result 2,041, Processing Time 0.027 seconds

Biomechanical Analysis of Human Foot Joints by Using Computer Graphic-Based Model (컴퓨터 그래픽 모델을 이용한 족부 관절의 생체역학적 해석)

  • Seo Min Jwa;Kim Si Yeol;Cho Won Hak;Choi Hyeon-Chang;Choi Hyeonki
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.6 s.81
    • /
    • pp.495-500
    • /
    • 2003
  • The purpose of this investigation was to study the kinematics of joints between the foot segments based on computer graphic model during the stance? phase of walking. In the model, all joints were assumed to act as monocentric. single degree of freedom hinge joints. The motion of foot was captured by a video collection system using four cameras. The model fitted in an individual subject was simulated with this motion data. The range of motion of the first tarsometatarsal joint was $-8^{\circ}\;\~\;-13^{\circ}$, and the first metatarsophanlangeal joint was $-13^{\circ}\;\~\;-48^{\circ}$. The kinematic data of tarsometatarsal joint and metatarsophanlangeal joint were similar to the previous data. Therefore, our method based on the graphical computer model is considered useful.

Knee Joint Control of New KAFO for Polio Patients Gait Improvement (소아마비 환자의 보행개선을 위한 새로운 장하지 보조기의 무릎관절 제어)

  • 강성재;조강희;김영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.132-135
    • /
    • 2002
  • In the present study, an electro-mechanical KAFO (knee-ankle-foot orthosis) which satisfies both the stability in stance and the knee flexion in swing was developed and evacuated in eight polio patients. A knee joint control algorithm suitable for polio patients who are lack of the stability in pre-swing was also developed and various control systems and circuits were also designed. In addition, knee flexion angles and knee moments were measured and analyzed for polio patients who used the developed KAFO with the three-dimensional motion analysis system. Energy consumption was also evaluated for the developed KAFO by measuring the movement of the COG (center of gravity) during gait. From the present study, the designed foot switch system successfully determined the gait cycle of polio patients and controlled knee joint of the KAFO, resulting in the passive knee flexion or foot clearance during swing phase. From the three-dimensional gait analysis for polio patients, it was found that the controlled-knee gait with the developed electro-mechanical KAFO showed the knee flexion of 40$^{\circ}$∼45$^{\circ}$ at an appropriate time during swing. Vertical movements of COG in controlled-knee gait (gait with the developed electro-mechanical KAFO) were significantly smaller than those in looked knee gait(gait with the locked knee Joint). and correspondingly controlled-knee gait reduced approximately 40% less energy consumption during horizontal walking gait. More efficient gait patterns could be obtained when various rehabilitation training and therapeutic programs as well as the developed electro-mechanical KAFO were applied for polio patients.

  • PDF

Joint Stability and lateral behavior of composite piles (복합말뚝 연결부 안정성 평가 및 수평거동특성 분석)

  • Shin, Yun-Sup;Park, Jae-Hyun;Hwang, Ui-Seong;Cho, Sung-Han;Chung, Moon-Kyung;Boo, Kyo-Tag
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.553-558
    • /
    • 2010
  • The behavior of composite piles composed of steel pipe pile in the upper part and concrete pile in the lower part by a mechanical splicing joint was examined by field lateral load tests and bending tests. A total of 7 piles including two instrumented piles for bending test were installed. The soil profile consists of soft clay with weak silt with shallow groundwater level. Laboratory tests were carried out to determine the basic soil characteristics and the strength parameters. This paper presents the composite pile behavior with various portions of the upper steel pile: 0, 20, 30, and 45% of the pile embedded pile length. Three-point bending tests were performed to investigate the stress-strain relation at the mechanical joint. Based on these test results, the behavior of composite piles with various upper steel pile length are evaluated and the stability of mechanical joints are examined. Through comparisons with results of field load tests, it was found that lateral load carrying capacity of the composite piles increased and deflections of the composite piles decreased with increasing the upper steel piles. The mechanical joint was proved to retain its structural stability against the tested load conditions. Economical benefits of composite pile of this kind can be gained by setting adequately the length of the upper steel pipe piles.

  • PDF

Development of POSTEC HAND-V Index Finger Module

  • Lee, Ju-Hyoung;Youm, Youn-Gil;Chung, Wan-Kyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2022-2026
    • /
    • 2003
  • We define that the end effector is the device which interact environment or objects with contact to execute tasks. Up to now, many researchers developed anthropomorphic robotic hands as end effectors. In this paper, we will discuss a problem on the development of a human-scale and motor-driven anthropomorphic robot hand. In this paper, design concept, actuator and transmission, kinematic design and sensing device are presented. By imitating the physiology of human hands, we devised new metacarpalphalangeal joint and interphalangeal joint suitable for human-size robot hands

  • PDF

An Experimental Study on the Strength Evaluation of Mechanical Press Joint (기계적 프레스 접합부의 강도 평가에 관한 실험적 연구)

  • Park, Yeong-Geun;Jeong, Jin-Seong;Kim, Ho-Gyeong;Lee, Yong-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.438-448
    • /
    • 2000
  • Mechanical press joining technique has been used in sheet metal joining processes because of its simple process and possibility of joining dissimiliar metals, such as steel and aluminum. The static and cyclic behavior of single overlap AI-alloy and steel(SPCC) joints has been investigate. Relationships were developed to estimate the strength of the joint taking into consideration base metal strength properties and the geometry of the joint. Fatigue test results have shown that fatigue resistance of the SPCC mechanical press joints is almost equal to that of the spot weld at the life of $10^6$ cycles. Also, the dissimilar material jointed specimen with upper SPCC plate and button diameter corresponding to the nugget diameter of the spot welded specimen has almost same strength as the same material jointed specimen and as the spot welded specimen.

An Experimental study on Improvement of Mechanical Press-Joining Strength of the Spin Drum Seaming Division in Washing Machine (스핀드럼 시밍부의 기계적 프레스 접합강도 향상에 관한 실험적 연구)

  • Kim, E.S.;Kim, B.M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.127-131
    • /
    • 2006
  • There are being a lot of studies for achievement of high speed Dehydration, high-strength and Lightweight of washing machine in the latest washing machine business. It is essential that Press-joining Strength of Spin Drum Seaming division is improved .to attain that target. Generally, we are using Mechanical press-joining by Seaming and T.I.G (Tungsten Inert Gas) welding among part joint method. Mechanical press-joining method that is mainly using for Stainless Steel (STS430) Drum have lots of merit that consumption of energy is low more than welding and production costs cut down and generation of the corrosion is solved by removing weld zone defect and materials having different properties are enable to join without special equipment. But, it is difficult to realize joint strength required at high speed operation because joint strength of mechanical press-joining method is low remarkably in comparison with welding. Also, there are a lot of analysis difficulties and very limited research is under way due to the dynamic factor such as multistage plastic working, elastic recovery, residual stress etc. The results of this study show optimal joining condition for mechanical press-joining by performing lots of tensile joining strength test with various specimen under multi-change of important design factor such as seaming width, bead area and bead depth etc.

  • PDF

Measurement of the Compressive Force on the Knee Joint Model fabricated by 3D Printing (3D 프린팅으로 제작된 무릎 관절모델의 압축력 측정)

  • Jeong, Hoon Jin;Jee, Min-Hee;Kim, So-Youn;Lee, Seung-Jae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2014
  • Recent experimental observations support the hypothesis that mechanical stimuli play a role in regulating the specialized molecular expression of articular cartilage in vitro and in vivo. Other studies have demonstrated that the continuous passive motion(CPM)bioreactor for whole joints can provide a platform for possible future in vitro studies and applications, including possible interactions of bio-mechanical and biochemical signals. In this study, we have developed acustom-made bioreactor capable of bending and stretching with circular type motion, and a biomimetic knee joint model, using a 3D printer. This system could be used to investigate the effects of rehabilitative joint motion of dynamic culture.

Development of Machine Vision System and Dimensional Analysis of the Automobile Front-Chassis-Module

  • Lee, Dong-Mok;Yang, Seung-Han;Lee, Sang-Ryong;Lee, Young-Moon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2209-2215
    • /
    • 2004
  • In the present research work, an automated machine vision system and a new algorithm to interpret the inspection data has been developed. In the past, the control of tolerance of front-chassis-module was done manually. In the present work a machine vision system and required algorithm was developed to carryout dimensional evaluation automatically. The present system is used to verify whether the automobile front-chassis-module is within the tolerance limit or not. The directional ability parameters related with front-chassis-module such as camber, caster, toe and king-pin angle are also determined using the present algorithm. The above mentioned parameters are evaluated by the pose of interlinks in the assembly of an automobile front-chassis-module. The location of ball-joint center is important factor to determine these parameters. A method to determine the location of ball-joint center using geometric features is also suggested in this paper. In the present work a 3-D best fitting method is used for determining the relationship between nominal design coordinate system and the corresponding feature coordinate system.

Structural Safety of Universal Joint using FEM Simulation (FEM 시뮬레이션을 이용한 유니버설 조인트의 구조안전성)

  • Jung, Jong Yun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.213-219
    • /
    • 2018
  • Mechanical components are to be produced with accurate dimensions in order to function properly in assemblies of a machine. Once designs of mechanical components are created, designers examine the designs by adopting many known experimental methods. A primary test method includes stress and strain evaluation of structural parts. In addition, fatigue test and vibration analysis are an important test method for mechanical components. Real experiments at a laboratory are established when products are manufactured. Since design changes should be done before producing the designs in factories, rapid modifications for new designs are required in production industries. FEM simulation is a proper choice for a design evaluation with speed at a detail stage in design process. This research focuses modeling and mechanical simulation of a mechanical component in order to ensure structural safety. In this paper, a universal joint, being used in driving axels of vehicles, is studied as a target component. A design model is created and tested in some ways by using commercial software of FEM. The designed component is being twisted to transmit heavy power and thus, torsional stress should be under strengths of the component's material. The next is fatigue analysis to convince fatigue cycles to be within the endurance limit of the material. Another test is a vibration analysis for rotational components. This research draws final conclusions from these test analyses and recommends whether the designed model is under safety condition in terms of mechanical structure.

Evaluation and Design for Joint Configurations Based on Kinematic Analysis (운동학에 기초한 로봇 손가락의 관절구조 평가 및 설계)

  • Hwang Chang-Soon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.2 s.233
    • /
    • pp.176-187
    • /
    • 2005
  • This paper presents an evaluation of joint configurations of a robotic finger based on kinematic analysis. The evaluation is based on an assumption that the current control methods for the fingers require that the contact state specified by the motion planner be maintained during manipulation. Various finger-joint configurations have been evaluated for different contact motions. In the kinematic analysis, the surface of the manipulated object was represented by B-spline surface and the surface of the finger was represented by cylinders and a half ellipsoid. Three types of contact motion, namely, 1) pure rolling, 2) twist-roiling, and 3) slide-twist-rolling are assumed in this analysis. The finger-joint configuration best suited for manipulative motion is determined by the dimension of manipulation workspace. The evaluation has shown that the human-like fingers are suitable for maintaining twist-rolling and slide-twist-rolling but not for pure rolling. A finger with roll joint at its fingertip link, which is different from human fingers, proved to be better for pure rolling motion because it can accommodate sideway motions of the object. Several kinds of useful finger-joint configurations suited for manipulating objects by fingertip surface are proposed.